Untitled
Abstract: No abstract text available
Text: MA785A Trigger Transformer for Spark Gaps DESCRIPTION The MA785A is a compact trigger transformer designed for triggering spark gaps. FEATURES * Trigger voltage up to 40 kV * Fast rise time – pulses up to 30 kV/ms * Flame retardant – approved to UL94 V-2
|
Original
|
MA785A
MA785A
NY10523-1482
A1A-MA785A
|
PDF
|
FSR630
Abstract: FSR660 pc817 fairchild FAN480X FCP20N60 FAN6210MY JESD22-A114 zd 5.6v uf1007 DIODE pc817 dual
Text: FAN6210 Primary-Side Synchronous Rectifier SR Trigger Controller for Dual Forward Converter Features Description Primary-Side Trigger Controller for Dual Forward Converters with Synchronous Rectifier (SR) FAN6210 is a primary-side trigger Integrated Circuit (IC)
|
Original
|
FAN6210
FAN6210
FSR660/630.
FSR630
FSR660
pc817 fairchild
FAN480X
FCP20N60
FAN6210MY
JESD22-A114
zd 5.6v
uf1007 DIODE
pc817 dual
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Solid State ReIays ISOLATING TRANSFORMER CONTROL DC-AC CONVERTER TRIAC LOAD TRIGGER CIRCUIT Figure 1. Hybrid SSR Figure 2. Transformer-Coupled SSR AC POWER PHOTO-TRANSISTOR REED RELAY TRIAC CONTROL SIGNAL OPTIONAL PREAMPLIFIER LED LOAD CONTROL SIGNAL TRIGGER
|
Original
|
60-Hz
Z-127
|
PDF
|
trigger transformer
Abstract: No abstract text available
Text: FETCO TYPE FTT ELECTRa TUCHNIK Trigger Transformer Schematic 1 Pri. 2 Features: • • 3 Sec. 4 Variations: • Applications include Laser firing circuits • choice of terminals and terminal location • Designed for low cost trigger source isolation in
|
Original
|
1500Dimensions
trigger transformer
|
PDF
|
Untitled
Abstract: No abstract text available
Text: PT-50 Vishay Dale Through Hole Transformers Trigger, SCR Isolation FEATURES • Designed for low-cost trigger source isolation in SCR power control circuits • Small physical size and low profile provide packaging advantages • Designed to transfer high amplitude or long duration
|
Original
|
PT-50
PT-20
2002/95/EC
2002/95/EC.
2002/95/EC
2011/65/EU.
JS709A
02-Oct-12
|
PDF
|
transformer dash 2 b-5
Abstract: No abstract text available
Text: MODELS PT-10 and PT-20 Transformers Pulse, Trigger Type FEATURES • Choice of printed circuit or bobbin-type configurations • Designed to transfer high amplitude or long duration pulses without saturation • Designed for low-cost trigger source isolation in half and
|
OCR Scan
|
PT-10
PT-20
transformer dash 2 b-5
|
PDF
|
Trigger Units
Abstract: OPTOCOUPLER for thyristor gate OPTOCOUPLER thyristor thyristor using zero crossing circuit 690VRMS Optocoupler with thyristor thyristor using zero crossing thyristor k2 k2 VDE0884 3 phase thyristor dc drive
Text: PSTT PC / PSTT SC / PSTT ZC Active Trigger Units for Thyristors The Active Trigger is an economic replacement of pulse transformers including all associated circuitry in phase controlled thyristor equipment. Due to the small control current it becomes the ideal link between any
|
Original
|
690Vrms.
Trigger Units
OPTOCOUPLER for thyristor gate
OPTOCOUPLER thyristor
thyristor using zero crossing circuit
690VRMS
Optocoupler with thyristor
thyristor using zero crossing
thyristor k2 k2
VDE0884
3 phase thyristor dc drive
|
PDF
|
Untitled
Abstract: No abstract text available
Text: PT-50 Vishay Dale Through Hole Transformers Trigger, SCR Isolation FEATURES • Designed for low-cost trigger source isolation in SCR power control circuits • Small physical size and low profile provide packaging advantages • Designed to transfer high amplitude or long duration
|
Original
|
PT-50
11-Mar-11
|
PDF
|
trigger transformer
Abstract: Design Considerations for Triggering of Flashlamp tr-180b TR-2298 PerkinElmer spark gap spark gap trigger transformer PerkinElmer 1795 40kv transformer PerkinElmer Optoelectronics tr-1855 TR-132C
Text: Imaging D A T A S H E E T Lighting Telecom Trigger Transformers and Chokes Trigger Transformers and Chokes Description Features PerkinElmer has been manufacturing high voltage transformers since 1956. • Peak output voltage up to 40kV Standard and custom designs
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: r-N SCR ISOLATION TRIGGER TRANSFORMER MODEL PT50 FEATURES • Designed for low-cost trigger source isolation in SCR Power Control Circuits • Small physical size and low profile provide packaging advantages Designed to transfer high amplitude or long duration pulses without saturation.
|
OCR Scan
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MODEL PT-50 Transformers Trigger, SCR Isolation FEATURES • Designed for low-cost trigger source isolation in SCR Power Control Circuits • Small physical size and low profile provide packaging advantages • Designed to transfer high amplitude or long duration pulses without saturation
|
OCR Scan
|
PT-50
PT-20
|
PDF
|
PT50110
Abstract: DALE PT 30 PT50101
Text: PT-50 Vishay Dale Through Hole Transformers Trigger, SCR Isolation FEATURES • Designed for low-cost trigger source isolation in SCR power control circuits • Small physical size and low profile provide packaging advantages • Designed to transfer high amplitude or long duration
|
Original
|
PT-50
2011/65/EU
2002/95/EC.
2002/95/EC
2011/65/EU.
12-Mar-12
PT50110
DALE PT 30
PT50101
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MODEL PT-50 Transformers Trigger, SCR Isolation FEATURES • Designed for low-cost trigger source isolation in SCR power control circuits • Small physical size and low profile provide packaging advantages • Designed to transfer high amplitude or long duration pulses without saturation
|
OCR Scan
|
PT-50
PT-20
|
PDF
|
VISHAY diode MARKING EB
Abstract: transformer dash 2 b-5 PT-10 PT-20 motor speed ratio polyurethane
Text: Models PT-10 and PT-20 Vishay Dale Transformers Pulse, Trigger Type FEATURES • Choice of printed circuit or bobbin-type configurations. • Designed to transfer high amplitude or long duration pulses without saturation. RoHS COMPLIANT • Designed for low-cost trigger source isolation in
|
Original
|
PT-10
PT-20
11-Mar-11
VISHAY diode MARKING EB
transformer dash 2 b-5
PT-20
motor speed ratio polyurethane
|
PDF
|
|
SCR POWER CONTROL
Abstract: "scr power control" scr 106 DALE transformers PT-20 PT-50 dash transformer
Text: Model PT-50 Vishay Dale Transformers Trigger, SCR Isolation FEATURES • Designed for low-cost trigger source isolation in SCR power control circuits. • Small physical size and low profile provide packaging advantages. • Designed to transfer high amplitude or long duration pulses without saturation.
|
Original
|
PT-50
PT-20
29-Apr-99
SCR POWER CONTROL
"scr power control"
scr 106
DALE transformers
PT-50
dash transformer
|
PDF
|
SCR TRIGGER PULSE TRANSFORMER
Abstract: ac motor speed control with scr DALE PULSE TRANSFORMER PT-10 PT-20
Text: Models PT-10 and PT-20 Vishay Dale Transformers Pulse, Trigger Type FEATURES • Choice of printed circuit or bobbin-type configurations. • Designed to transfer high amplitude or long duration pulses without saturation. • Designed for low-cost trigger source isolation in half and
|
Original
|
PT-10
PT-20
11-Dec-02
SCR TRIGGER PULSE TRANSFORMER
ac motor speed control with scr
DALE PULSE TRANSFORMER
PT-20
|
PDF
|
transformer dash 2 b-5
Abstract: 0/transformer dash 2 b-5 PT-10 PT-20
Text: Models PT-10 and PT-20 Vishay Dale Transformers Pulse, Trigger Type FEATURES • Choice of printed circuit or bobbin-type configurations. • Designed to transfer high amplitude or long duration RoHS pulses without saturation. COMPLIANT • Designed for low-cost trigger source isolation in
|
Original
|
PT-10
PT-20
08-Apr-05
transformer dash 2 b-5
0/transformer dash 2 b-5
PT-20
|
PDF
|
DALE transformers
Abstract: No abstract text available
Text: PT-50 Vishay Dale Transformers Trigger, SCR Isolation FEATURES • Designed for low-cost trigger source isolation in SCR power control circuits. • Small physical size and low profile provide packaging advantages. • Designed to transfer high amplitude or long duration pulses without saturation.
|
Original
|
PT-50
PT-20
08-Apr-05
DALE transformers
|
PDF
|
0/transformer dash 2 b-5
Abstract: No abstract text available
Text: PT-50 Vishay Dale Transformers Trigger, SCR Isolation FEATURES • Designed for low-cost trigger source isolation in SCR power control circuits. • Small physical size and low profile provide packaging advantages. RoHS • Designed to transfer high amplitude or long duration pulses without saturation.
|
Original
|
PT-50
PT-20
08-Apr-05
0/transformer dash 2 b-5
|
PDF
|
transformer dash 2 b-5
Abstract: No abstract text available
Text: Models PT-10 and PT-20 Vishay Dale Transformers Pulse, Trigger Type FEATURES • Choice of printed circuit or bobbin-type configurations. • Designed to transfer high amplitude or long duration pulses without saturation. RoHS COMPLIANT • Designed for low-cost trigger source isolation in
|
Original
|
PT-10
PT-20
08-Apr-05
transformer dash 2 b-5
|
PDF
|
trigger transformer
Abstract: No abstract text available
Text: High Voltage Trigger Transformer ELECTRONICS INC. EPC3215G-X • Used as Trigger Transformer in Photoflash Circuits • Operating Temperature : -40°C to +85°C • UL 94V-0 Recognized Components Actual Size • UL 1446 Class B Insulation System Electrical Parameters @ 25° C
|
Original
|
EPC3215G-X
EPC3215G-1
EPC3215G-2
CSC3215G-X
trigger transformer
|
PDF
|
trigger transformer
Abstract: trigger transformer layout EPC3215G-3 EPC3215G-X EPC3215G-1 EPC3215G-2 94v0 schematic
Text: High Voltage Trigger Transformer ELECTRONICS INC. EPC3215G-X • Used as Trigger Transformer in Photoflash Circuits • Operating Temperature : -40°C to +85°C • UL 94V-0 Recognized Components Actual Size • UL 1446 Class B Insulation System Electrical Parameters @ 25° C
|
Original
|
EPC3215G-X
EPC3215G-1
EPC3215G-2
EPC3215G-3
CSC3215G-X
trigger transformer
trigger transformer layout
EPC3215G-3
EPC3215G-X
EPC3215G-1
EPC3215G-2
94v0 schematic
|
PDF
|
PT10
Abstract: transformer dash 2 b-5 PT-10 PT-20
Text: Models PT-10 and PT-20 Vishay Dale Transformers Pulse, Trigger Type FEATURES • Choice of printed circuit or bobbin-type configurations. • Designed to transfer high amplitude or long duration pulses without saturation. RoHS COMPLIANT • Designed for low-cost trigger source isolation in
|
Original
|
PT-10
PT-20
18-Jul-08
PT10
transformer dash 2 b-5
PT-20
|
PDF
|
scr 106
Abstract: scr power controls schematic diagram for heater schematic diagram for SCR controls heater SCR POWER CONTROL PT-20 PT-50
Text: PT-50 Vishay Dale Transformers Trigger, SCR Isolation FEATURES • Designed for low-cost trigger source isolation in SCR power control circuits. • Small physical size and low profile provide packaging advantages. • Designed to transfer high amplitude or long duration pulses without saturation.
|
Original
|
PT-50
PT-20
11-Dec-02
scr 106
scr power controls schematic diagram for heater
schematic diagram for SCR controls heater
SCR POWER CONTROL
PT-50
|
PDF
|