Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    HUMIDIFIERS Search Results

    HUMIDIFIERS Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    LR3902

    Abstract: BE2G
    Text: Energy Limiting CLASS 2 ENERGY LIMITING TRANSFORMERS • Used in chimes, door bells, security systems, decorative lighting, furnaces, humidifiers, appliances, vending machines, intercom system type applications. • Rugged, low noise, cool running design, indoor use only.


    Original
    PDF

    transformer 240v

    Abstract: humidifiers LR3902
    Text: Energy Limiting BF Series 75 VA - CLASS 2 ENERGY LIMITING TRANSFORMERS • Used in chimes, door bells, security systems, decorative lighting, furnaces, humidifiers, appliances, vending machines, intercom system type applications. • Rugged, low noise design, indoor use only.


    Original
    PDF

    BD 222 ST

    Abstract: No abstract text available
    Text: CLASS 2 - ENERGY LIMITING TRANSFORMERS CLASS 2 ENERGY LIMITING TRANSFORMERS • Used in chimes, door bells, security systems, decorative lighting, furnaces, humidifiers, appliances, vending machines, intercom system type applications. • Rugged, low noise, cool running design, indoor use only.


    Original
    PDF

    BF2G

    Abstract: transformer 240v LR3902
    Text: Energy Limiting 75 VA - CLASS 2 ENERGY LIMITING TRANSFORMERS • Used in chimes, door bells, security systems, decorative lighting, furnaces, humidifiers, appliances, vending machines, intercom system type applications. • Rugged, low noise design, indoor use only.


    Original
    PDF

    2381 691

    Abstract: "Humidity Sensor"
    Text: 2381 691 90001/HUMIDITY-SENS-E Vishay BCcomponents Humidity Sensor APPLICATIONS • Humidity measurements in electronic hygrometers for domestic use • Self-regulating air humidifiers, etc. DESCRIPTION QUICK REFERENCE DATA PARAMETER Humidity range RH Capacitance at + 25 °C; 43 % RH;


    Original
    PDF 90001/HUMIDITY-SENS-E 18-Jul-08 2381 691 "Humidity Sensor"

    sensor acetone

    Abstract: 2322 691 90001 Foil "Humidity Sensor" HUMIDITY sensor resistance hygrometers
    Text: 2322 691 90001 Vishay BCcomponents Humidity Sensor APPLICATIONS • Humidity measurements in electronic hygrometers for domestic use • Self-regulating air humidifiers, etc. DESCRIPTION QUICK REFERENCE DATA PARAMETER VALUE Humidity range RH 10 to 90 Capacitance at +25 °C; 43% RH; 100 kHz 122 ±15%


    Original
    PDF MEA832 MBD125 10-Oct-03 sensor acetone 2322 691 90001 Foil "Humidity Sensor" HUMIDITY sensor resistance hygrometers

    Untitled

    Abstract: No abstract text available
    Text: 2381 691 90001/HUMIDITY-SENS-E Vishay BCcomponents Humidity Sensor APPLICATIONS • Humidity measurements in electronic hygrometers for domestic use • Self-regulating air humidifiers, etc. DESCRIPTION QUICK REFERENCE DATA PARAMETER Humidity range RH Capacitance at + 25 °C; 43 % RH;


    Original
    PDF 90001/HUMIDITY-SENS-E 2011/65/EU 2002/95/EC. 2002/95/EC 2011/65/EU. 12-Mar-12

    Untitled

    Abstract: No abstract text available
    Text: 2381 691 90001/HUMIDITY-SENS-E Vishay BCcomponents Humidity Sensor APPLICATIONS • Humidity measurements in electronic hygrometers for domestic use • Self-regulating air humidifiers, etc. DESCRIPTION QUICK REFERENCE DATA PARAMETER Humidity range RH Capacitance at + 25 °C; 43 % RH;


    Original
    PDF 90001/HUMIDITY-SENS-E 11-Mar-11

    Untitled

    Abstract: No abstract text available
    Text: HSM-20G HUMIDITY SENSOR MODULE The module of HSM-20G is essential for those applications where the relative humidity can be converted to standard voltage output. 1. Applications Humidifiers & humidifiers Air-conditioner Humidity data loggers Automotive climate control


    Original
    PDF HSM-20G HSM-20G HSM-20Sï HSM-20Gï HSM-20S

    Untitled

    Abstract: No abstract text available
    Text: 2322 691 90001 Vishay BCcomponents Humidity Sensor APPLICATIONS • Humidity measurements in electronic hygrometers for domestic use • Self-regulating air humidifiers, etc. DESCRIPTION QUICK REFERENCE DATA PARAMETER VALUE Humidity range RH Capacitance at +25 °C; 43% RH; 100 kHz


    Original
    PDF MEA832 MBD125 11-May-04

    water level switch

    Abstract: Humidifier humidifiers MK2 relay datasheet MK22 water level sensors WATER TEMP SENSOR liquid float temperature sensor sensors used in water tank to detect water level liquid float level sensor
    Text: Air Conditioners and Humidifiers Use Reed Sensors to Sense the Upper Upper Limit of Their Reservoirs REED RELAYS REED SENSORS REED SWITCHES Introduction In the summer months, warm and humid air invades the area. This is the case in most regions of the world. Depending how close one is to the equator this


    Original
    PDF MK20/1 water level switch Humidifier humidifiers MK2 relay datasheet MK22 water level sensors WATER TEMP SENSOR liquid float temperature sensor sensors used in water tank to detect water level liquid float level sensor

    E184371

    Abstract: LR3902
    Text: Energy Limiting BA-BE Series CLASS 2 ENERGY LIMITING TRANSFORMERS • Used in chimes, door bells, security systems, decorative lighting, furnaces, humidifiers, appliances, vending machines, intercom system type applications. • Rugged, low noise, cool running design, indoor use only.


    Original
    PDF E184371 LR3902

    "Humidity Sensor"

    Abstract: humidity sensor sensor acetone
    Text: 2381 691 90001/HUMIDITY-SENS-E Vishay BCcomponents Humidity Sensor APPLICATIONS • Humidity measurements in electronic hygrometers for domestic use • Self-regulating air humidifiers, etc. DESCRIPTION QUICK REFERENCE DATA PARAMETER VALUE UNIT Humidity range RH


    Original
    PDF 90001/HUMIDITY-SENS-E 18-Jul-08 "Humidity Sensor" humidity sensor sensor acetone

    humidity sensor philips H1

    Abstract: philips H1 2322 691 90001 sensor acetone 2322 691 90001 philips h1 Philips humidity sensor 90001 humidity sensor Humidity Sensors
    Text: BC Components Product specification Humidity sensor APPLICATIONS • Humidity measurements in electronic hygrometers for domestic use • Self-regulating air humidifiers, etc. DESCRIPTION This capacitive atmospheric humidity sensor consists of a non-conductive


    Original
    PDF MEA832 humidity sensor philips H1 philips H1 2322 691 90001 sensor acetone 2322 691 90001 philips h1 Philips humidity sensor 90001 humidity sensor Humidity Sensors

    humidity sensor philips H1

    Abstract: philips H1 2322 691 90001 philips h1 H1 humidity sensor Philips 2322 691 90001 "Humidity Sensor" marking 691 Philips humidity sensor humidity sensor
    Text: Philips Components Product specification Humidity sensor APPLICATIONS • Humidity measurements in electronic hygrometers for domestic use • Self-regulating air humidifiers, etc. DESCRIPTION This capacitive atmospheric humidity sensor consists of a non-conductive


    Original
    PDF MEA832 humidity sensor philips H1 philips H1 2322 691 90001 philips h1 H1 humidity sensor Philips 2322 691 90001 "Humidity Sensor" marking 691 Philips humidity sensor humidity sensor

    "Humidity Sensor"

    Abstract: 2381 691 90001
    Text: 2381 691 90001/HUMIDITY-SENS-E Vishay BCcomponents Humidity Sensor APPLICATIONS • Humidity measurements in electronic hygrometers for domestic use • Self-regulating air humidifiers, etc. DESCRIPTION QUICK REFERENCE DATA PARAMETER VALUE UNIT Humidity range RH


    Original
    PDF 90001/HUMIDITY-SENS-E 08-Apr-05 "Humidity Sensor" 2381 691 90001

    Untitled

    Abstract: No abstract text available
    Text: 2381 691 90001/HUMIDITY-SENS-E Vishay BCcomponents Humidity Sensor APPLICATIONS • Humidity measurements in electronic hygrometers for domestic use • Self-regulating air humidifiers, etc. DESCRIPTION QUICK REFERENCE DATA PARAMETER Humidity range RH Capacitance at + 25 °C; 43 % RH;


    Original
    PDF 90001/HUMIDITY-SENS-E 2002/95/EC. 2002/95/EC 2011/65/EU. JS709A 02-Oct-12

    E84592

    Abstract: 40VA LR33322 20VA bells humidifiers intercom system
    Text: Energy Limiting CLASS 2 - PLUG IN ENERGY LIMITING TRANSFORMERS • Used in chimes, door bells, security systems, decorative lighting, furnaces, humidifiers, appliances, vending machines, intercom system type applications. • Enclosed in an attractive plug in black plastic case.


    Original
    PDF 120VAC LR33322) E84592) E84592 40VA LR33322 20VA bells humidifiers intercom system

    C7089R1013

    Abstract: brick game HZ322, honeywell HM506 YTH5320R1000 YTH5320R1017 TH6220 YTH6320R1015 YTHX9321R1000 YTHX9321R5003
    Text: Wireless Solutions Application Selection Guide THERMOSTATS ZONING AIR CLEANERS HUMIDIFIERS HUMIDIFIERS UV SYSTEMS VENTILATION WATER SOLUTIONS COMBUSTION RedLINK Wireless Systems TrueZONE Panel Return Air Sensor Wireless FocusPRO ® Portable Comfort Control


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Datasheet AC/DC Drivers PWM type DC/DC converter IC Included 650V MOSFET BM2PXX3 Series ●General The PWM type DC/DC converter BM2PXX3 for AC/DC provide an optimum system for all products that include an electrical outlet. BM2PXX3 supports both isolated and non-isolated


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Datasheet AC/DC Drivers PWM type DC/DC converter IC Included 650V MOSFET BM2PXX2 Series ●General The PWM type DC/DC converter BM2PXX2 for AC/DC provide an optimum system for all products that include an electrical outlet. BM2PXX2 supports both isolated and non-isolated


    Original
    PDF

    AN037

    Abstract: simco touch sensitive saran ionizer HSMS-8101 HSMS-8202 simco electrostatic Desco Industries 3M Touch Systems
    Text: DESIGN APPLICATION NOTE - AN037 An ESD Overview, and Suggested Handling Precautions What is static electricity, and why are we concerned about it? Static electricity is the charge that builds up on dissimilar materials when they are brought together then separated. We’ve all experienced static electricity


    Original
    PDF AN037 EAN-102030 AN037 simco touch sensitive saran ionizer HSMS-8101 HSMS-8202 simco electrostatic Desco Industries 3M Touch Systems

    RHU-217-AT

    Abstract: Mercator RHU217-AT RHU217 dehumidifier Mercator RHU217-AT resistor Humidity humidifiers
    Text: Temperature & Humidity Module RHU217-AT 51+0 991 A p p lic a tio n s • Air Conditioners • Room Humidifiers / humidifiers • Ventilation Systems The RHU-217-AT is able to measure humidity and temperature without the need for any external electronics. A linear 0 to 3.3VDC output corresponds to 0 to 100% full scale


    OCR Scan
    PDF RHU217-AT RHU-217-AT 50Kii Mercator RHU217-AT RHU217 dehumidifier Mercator RHU217-AT resistor Humidity humidifiers

    philips H1 2322 691 90001

    Abstract: humidity sensor philips H1 Philips H1 H1 humidity sensor
    Text: Product specification Philips Components Humidity sensor APPLICATIONS • Humidity measurements in electronic hygrometers for domestic use • Self-regulating air humidifiers, etc. DESCRIPTION This capacitive atmospheric humidity sensor consists of a non-conductive


    OCR Scan
    PDF MEA832 philips H1 2322 691 90001 humidity sensor philips H1 Philips H1 H1 humidity sensor