Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    DOSIMETER Search Results

    DOSIMETER Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    DOSIMETER

    Abstract: sound level meter
    Text: 897 Sound Dosimeter Measuring System The 897 Dosimeter Sound Measuring System conducts personal noise surveys to meet IEC and OSHA requirements. Used as a sound level meter, the 897 provides a quick survey of targeted areas and suspect locations. The 897 is also ideal for industrial and environmental


    Original
    760mm RS-232 DOSIMETER sound level meter PDF

    dosimeter

    Abstract: UDOS001 radiation ionizing dose TID detector UDOS001-C DOS001 UDOS001-H Dose UDOS001-K hybrid teledyne teledyne Microelectronics
    Text: DOS001 Micro Dosimeter PART NUMBER DESCRIPTION UDOS001-C UDOS001-H UDOS001-K Micro Dosimeter - Commercial Micro Dosimeter - Class H Micro Dosimeter - Class K DESCRIPTION The Micro Dosimeter P/N UDOS001 is a compact hybrid microcircuit which directly measures total ionizing dose (TID) absorbed by an internal silicon test


    Original
    DOS001 UDOS001-C UDOS001-H UDOS001-K UDOS001) dosimeter UDOS001 radiation ionizing dose TID detector UDOS001-C DOS001 UDOS001-H Dose UDOS001-K hybrid teledyne teledyne Microelectronics PDF

    UV diode 320 nm

    Abstract: uv photodiode PDU-G102B uv photodiode wavelength 250 to 260 320nm
    Text: UV Enhanced GaN Detectors PDU-G102B PACKAGE DIMENSIONS INCH [mm] Ø.210 [5.35] QUARTZ WINDOW FILTER CAP WELDED Ø.118 [3.00] .055 [1.40] VIEWING ANGLE 61° CHIP ANODE 2X Ø.017 [0.43] .100 [2.54] .500 [12.70] Ø.181 [4.60] .112 [2.84] CATHODE CHIP DIMENSIONS INCH [mm]


    Original
    PDU-G102B 320nm PDU-G102B 200nm 350nm UV diode 320 nm uv photodiode uv photodiode wavelength 250 to 260 PDF

    Untitled

    Abstract: No abstract text available
    Text: narda/erf PERSONAL MONITORS • • • • • • • • • • 100 kHz to 100 GHz Detection Patented Design* Rugged, Highly Visible Housing High Power Overload Audible Alarm Varies with Emission Level Visual Alarm Latching Circuit All Dielectric Earphone Assembly


    OCR Scan
    PDF

    8 pin LM328 ic

    Abstract: LINEAR VOLTAGE REGULATOR LM328 8 PIN IC pin out of lm328 lm328 datasheet LM328 "Linear Voltage Regulator" ISL72991 HS9-139RH HS9S-117RH ISL72991RH
    Text: Low dose rate testing of the Intersil HS9S-117RH positive linear voltage regulator July 2006 Nick van Vonno Intersil Corporation Abstract: This document provides a brief introduction to low dose rate effects including discussion of Intersil’s approach to testing and qualification issues. We then report


    Original
    HS9S-117RH 100krad Cobalt-60 8 pin LM328 ic LINEAR VOLTAGE REGULATOR LM328 8 PIN IC pin out of lm328 lm328 datasheet LM328 "Linear Voltage Regulator" ISL72991 HS9-139RH ISL72991RH PDF

    Untitled

    Abstract: No abstract text available
    Text: Total dose testing of the ISL7124SRH Radiation Hardened Quad operational amplifier Nick van Vonno Intersil Corporation Revision 0 18 August 2010 Table of Contents 1. 2. 3. 4. 5 6 7 8 9 Introduction Reference Documents Part Description Test Description 4.1 Irradiation facility


    Original
    ISL7124SRH ISL7124SRH PDF

    Untitled

    Abstract: No abstract text available
    Text: Total dose testing of the IS-1009RH Voltage Reference Nick van Vonno Intersil Corporation Revision 0 January 2011 Table of Contents 1. 2. 3. 4. 5 6 7 8 9 Introduction Reference Documents Part Description Test Description 4.1 Irradiation facility 4.2 Test fixturing


    Original
    IS-1009RH IS1009RH 150krad PDF

    LM119

    Abstract: 8906HR
    Text: Military/Aerospace Analog Engineering N TOTAL DOSE RADIATION TEST I. INTRODUCTION Total dose radiation tests are designed to characterize changes in device performance due to total dose radiation. These tests are not intended to classify maximum radiation


    Original
    MIL-STD-883 LM119 8906HR PDF

    MIL-C-19978

    Abstract: CYR-Series glass capacitor CY10
    Text: Performance Characteristics of Multilayer Glass Dielectric Capacitors A B S T R A C T : Glass dielectric capacitors exhibit several key performance parameters critical to high performance circuitry. This technical paper is a summary of specialized tests performed on AVX


    Original
    S-PGDC00M806-C MIL-C-19978 CYR-Series glass capacitor CY10 PDF

    teradyne A360

    Abstract: 1N4747 A360 LM6161 QR6161ENG ST K 3567
    Text: Total-Dose Radiation Effects Characterization Engineering Evaluation Report for LM6161J/883 Final Rehan A. Zakai October 31, 1995 N TABLE OF CONTENTS I. INTRODUCTION. 1


    Original
    LM6161J/883 LM6161J/883 teradyne A360 1N4747 A360 LM6161 QR6161ENG ST K 3567 PDF

    mds 2658

    Abstract: LM139AW-QMLV
    Text: Military/Aerospace Analog Engineering N TOTAL DOSE RADIATION TEST I. INTRODUCTION Total dose radiation tests are designed to characterize changes in device performance due to total dose radiation. These tests are not intended to classify maximum radiation


    Original
    MIL-STD-883 mds 2658 LM139AW-QMLV PDF

    LP2953

    Abstract: No abstract text available
    Text: Military/Aerospace Analog Engineering N TOTAL DOSE RADIATION TEST I. INTRODUCTION Total dose radiation tests are designed to characterize changes in device performance due to total dose radiation. These tests are not intended to classify maximum radiation


    Original
    MIL-STD-883 LP2953 PDF

    "x-ray machine"

    Abstract: RAD-60 luggage security system RADOS dosimeter "x-ray detector" X-RAY INSPECTION ISL21009-50 AN01 ISL21007
    Text: Application Note 1533 X-Ray Effects on Intersil FGA References Introduction and Background The Intersil Floating Gate Analog FGA technology utilizes a robust stored charge technology borrowed from a standard EEPROM process to produce a precise reference voltage. The stored voltage is the heart of a


    Original
    AN1533 "x-ray machine" RAD-60 luggage security system RADOS dosimeter "x-ray detector" X-RAY INSPECTION ISL21009-50 AN01 ISL21007 PDF

    eel 19 2005 transformer

    Abstract: eel 19 2005 transformer spellman igbt gate driver circuit schematic schematic diagram igbt inverter welding machine
    Text: HIGH VOLTAGE REFERENCE MANUAL 4/2014 REV. 4 Copyright 2014 Spellman High Voltage Electronics Corp. T E C H N I C A L R E S O U R C E S M A N U A L TABLE OF CONTENTS Spellman USA and Corporate HQ 475 Wireless Blvd. Hauppauge, NY 11788 United States tel: +1-631-630-3000


    Original
    B-720, eel 19 2005 transformer eel 19 2005 transformer spellman igbt gate driver circuit schematic schematic diagram igbt inverter welding machine PDF

    RCM3110

    Abstract: dosimeter RCM3000 RCM3100
    Text: RabbitCore RCM3100 Microprocessor Core Module The RabbitCore RCM3100 is a cost-effective solution that allows embedded engineers to add intelligence and I/O control to a wide variety of peripheral devices. Overview Powered by the Rabbit® 3000 microprocessor, the compact


    Original
    RCM3100 RCM3100 RCM3000 RCM3110 dosimeter PDF

    K250 capacitor

    Abstract: 07 K250 GALVANOMETER AVX quality dielectric capacitor capacitors coefficient of thermal expansion
    Text: TECHNICAL INFORMATION PERFORMANCE CHARACTERISTICS OF MULTILAYER GLASS DIELECTRIC CAPACITORS by Ron Demcko AVX Corporation Raleigh, NC Abstract: Glass dielectric capacitors exhibit several key performance parameters critical to high performance circuitry. This technical paper is a summary of


    Original
    i0-539-1501 S-PGDC00M0401-R K250 capacitor 07 K250 GALVANOMETER AVX quality dielectric capacitor capacitors coefficient of thermal expansion PDF

    pellistor

    Abstract: blood gas detector coshh cleaning products gas detector co2 detector flash point how to measure carbon dioxide sot-23 mark 50ML
    Text: Data Pack A Issued March 2001 240-0143 Gas tube specifications Data Sheet Why gas detection? Exposure of employees to substances hazardous to health, should be prevented or adequately controlled. This is a fundamental requirement of the Control of Substances


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Military/Aerospace Analog Engineering N TOTAL DOSE RADIATION TEST I. INTRODUCTION Total dose radiation tests are designed to characterize changes in device performance due to total dose radiation. These tests are not intended to classify maximum radiation tolerance of any


    Original
    MIL-STD-883 PDF

    uv photodiode

    Abstract: PDU-G102B 320nm
    Text: UV Enhanced GaN Detectors PDU-G102B Advanced Photonix, Inc. PACKAGE DIMENSIONS INCH [mm] Ø.210 [5.35] .055 [1.40] 2X Ø.017 [0.43] Ø .118 [3.00] CATHODE VIEWING ANGLE 61° ANODE .100 [2.54] .500 [12.70] Ø.181 [4.60] .087 [2.21] CHIP CHIP DIMENSIONS INCH [mm]


    Original
    PDU-G102B 320nm PDU-G102B 200nm 350nm uv photodiode PDF

    dosimeter

    Abstract: Dosimeter radiation space Advanced Packaging Technology Of America Flip Chip on flex
    Text: Microelectronics and Packaging Over 45 Years of Proven Performance in Microelectronics Packaging Over 45 Years of Proven Performance Teledyne Microelectronic Technologies provides multichip modules and microelectronics for today’s most demanding applications. Designing, fabricating and testing high reliability


    Original
    PDF

    Thruster

    Abstract: Dosimeter radiation space microwave dosimeter milstar teledyne Microelectronics GIOTTO Flip Chip on flex titan camera
    Text: Microelectronics in Space Over 45 Years of Proven Performance in Microelectronics Packaging Over 45 Years of Proven Performance Teledyne Microelectronic Technologies provides multichip modules and microelectronics for today’s most demanding applications. Designing, fabricating and testing high


    Original
    PDF

    CLC505AJ-QML

    Abstract: MNCLC505A-X 300Krads SI11-0
    Text: N I. INTRODUCTION Total dose radiation tests are designed to characterize changes in device performance due to total dose radiation. These tests are not intended to classify maximum radiation tolerance of any particular device, rather, they simply show trends in the critical parameters as a function of total dose.


    Original
    MIL-STD-883 100pF, CLC505AJ-QML MNCLC505A-X 300Krads SI11-0 PDF

    PDU-G101A

    Abstract: UV 310 nm
    Text: UV Enhanced GaN Detectors PDU-G101A PACKAGE DIMENSIONS INCH [mm] Ø.210 [5.35] .055 [1.40] 2X Ø.017 [0.43] Ø .118 [3.00] CATHODE VIEWING ANGLE 61° ANODE .100 [2.54] .500 [12.70] Ø.181 [4.60] .087 [2.21] CHIP CHIP DIMENSIONS INCH [mm] .016 [0.40] SQ TO-46 PACKAGE


    Original
    PDU-G101A 365nm PDU-G101A 200nm 350nm UV 310 nm PDF

    LM2595J-ADJ-QML

    Abstract: 143715 74594
    Text: Military/Aerospace Analog Engineering N TOTAL DOSE RADIATION TEST I. INTRODUCTION Total dose radiation tests are designed to characterize changes in device performance due to total dose radiation. These tests are not intended to classify maximum radiation


    Original
    MIL-STD-883 LM2595J-ADJ-QML 143715 74594 PDF