Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    PTC OVERLOAD PROTECTION FOR TELECOMMUNICATION Search Results

    PTC OVERLOAD PROTECTION FOR TELECOMMUNICATION Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TCKE712BNL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 13.2 V, 3.65 A, Latch, Adjustable Over Voltage Protection, WSON10 Visit Toshiba Electronic Devices & Storage Corporation
    DF2B5PCT Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-3.6 V, SOD-882 (CST2) Visit Toshiba Electronic Devices & Storage Corporation
    DF2B7PCT Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-5.5 V, SOD-882 (CST2) Visit Toshiba Electronic Devices & Storage Corporation
    DF2B5M4ASL Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-3.6 V, SOD-962 (SL2) Visit Toshiba Electronic Devices & Storage Corporation
    DF2B6M4ASL Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-5.5 V, SOD-962 (SL2) Visit Toshiba Electronic Devices & Storage Corporation

    PTC OVERLOAD PROTECTION FOR TELECOMMUNICATION Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    ptc 2322 662 93131

    Abstract: PTC THERMISTOR thermistor 2322 662 98 ptc thermistor for overcurrent protection XGPU2 main distribution frame PTC lead disc thermistor 661 93139 thermistor ptc 18 telephone main distribution frame
    Text: BCcomponents DATA SHEET Overload protection for telecommunication PTC thermistors 2000 Oct 10 Supersedes data of 17th May 1999 File under BCcomponents, BC02 BCcomponents Overload protection for telecommunication PTC thermistors FEATURES • Wide resistance range in telecom


    Original
    UL1434 XGPU23 K20/21 UL1459/GR1089 ptc 2322 662 93131 PTC THERMISTOR thermistor 2322 662 98 ptc thermistor for overcurrent protection XGPU2 main distribution frame PTC lead disc thermistor 661 93139 thermistor ptc 18 telephone main distribution frame PDF

    IEC60286-2

    Abstract: 93146
    Text: 2381 66. 9. Vishay BCcomponents PTC Thermistors, Overload Protection For Telecommunication FEATURES PRIMARY PROTECTION OPTIONAL • • • • SECONDARY PROTECTION +θ PTC subscriber lines +θ PTC SUBSCRIBER LOOP INTERFACE CIRCUIT (SLIC) OR TRANSFORMER


    Original
    CCB913 UL1434 CCB614 11-Apr-05 IEC60286-2 93146 PDF

    thermistor 2322 662 98

    Abstract: IEC60286-2 telephone main distribution frame
    Text: 2381 66. 9. Vishay BCcomponents PTC Thermistors, Overload Protection For Telecommunication FEATURES PRIMARY PROTECTION OPTIONAL • • • • SECONDARY PROTECTION +θ PTC subscriber lines +θ PTC SUBSCRIBER LOOP INTERFACE CIRCUIT (SLIC) OR TRANSFORMER


    Original
    CCB913 UL1434 CCB614 15-Jun-05 thermistor 2322 662 98 IEC60286-2 telephone main distribution frame PDF

    main distribution frame

    Abstract: XGPU2 PTCTL7 PTC 09 ptc application note PTCTL4MR500SBE IEC60286-2 PTCTL6MR250STE ptc resistor 300 to 500 e ptc thermistor for overcurrent protection
    Text: 2381 66. 9./PTCTL.R.E Vishay BCcomponents PTC Thermistors, Overload Protection For Telecommunication FEATURES PRIMARY PROTECTION OPTIONAL +θ PTC subscriber lines SECONDARY PROTECTION +θ PTC voltage clamp +θ +θ SUBSCRIBER LOOP INTERFACE CIRCUIT


    Original
    18-Jul-08 main distribution frame XGPU2 PTCTL7 PTC 09 ptc application note PTCTL4MR500SBE IEC60286-2 PTCTL6MR250STE ptc resistor 300 to 500 e ptc thermistor for overcurrent protection PDF

    XGPU2

    Abstract: main distribution frame PTCTL6MR250STE Telephone EXchange mdf
    Text: 2381 66. 9./PTCTL.R.E Vishay BCcomponents PTC Thermistors, Overload Protection For Telecommunication FEATURES PRIMARY PROTECTION OPTIONAL +θ PTC subscriber lines SECONDARY PROTECTION +θ PTC voltage clamp +θ +θ SUBSCRIBER LOOP INTERFACE CIRCUIT


    Original
    2011/65/EU 2002/95/EC. 2002/95/EC 2011/65/EU. 12-Mar-12 XGPU2 main distribution frame PTCTL6MR250STE Telephone EXchange mdf PDF

    IEC60286-2

    Abstract: XGPU2 93118 thermistor 662 ptc application note RESISTOR 2322 VISHAY thermistor 2322 662 98 93037 ptc ptc 93081 ptc 2322 662 93131
    Text: 2322 66. 9. Vishay BCcomponents PTC Thermistors, Overload Protection For Telecommunication FEATURES PRIMARY PROTECTION OPTIONAL • • • • SECONDARY PROTECTION +θ PTC subscriber lines +θ PTC SUBSCRIBER LOOP INTERFACE CIRCUIT (SLIC) OR TRANSFORMER


    Original
    CCB913 UL1434 CCB614 15-Oct-04 IEC60286-2 XGPU2 93118 thermistor 662 ptc application note RESISTOR 2322 VISHAY thermistor 2322 662 98 93037 ptc ptc 93081 ptc 2322 662 93131 PDF

    Untitled

    Abstract: No abstract text available
    Text: 2381 66. 9./PTCTL.R.E Vishay BCcomponents PTC Thermistors, Overload Protection For Telecommunication FEATURES PRIMARY PROTECTION OPTIONAL +θ PTC subscriber lines SECONDARY PROTECTION +θ PTC voltage clamp +θ +θ SUBSCRIBER LOOP INTERFACE CIRCUIT


    Original
    2002/95/EC. 2002/95/EC 2011/65/EU. JS709A 02-Oct-12 PDF

    Untitled

    Abstract: No abstract text available
    Text: 2381 66. 9./PTCTL.R.E Vishay BCcomponents PTC Thermistors, Overload Protection For Telecommunication FEATURES PRIMARY PROTECTION OPTIONAL +θ PTC subscriber lines SECONDARY PROTECTION +θ PTC voltage clamp +θ +θ SUBSCRIBER LOOP INTERFACE CIRCUIT


    Original
    11-Mar-11 PDF

    h2181

    Abstract: No abstract text available
    Text: 2381 66. 9./PTCTL.R.E Vishay BCcomponents PTC Thermistors, Overload Protection For Telecommunication FEATURES PRIMARY PROTECTION OPTIONAL • • • • SECONDARY PROTECTION +θ +θ PTC PTC subscriber lines SUBSCRIBER LOOP INTERFACE CIRCUIT (SLIC)


    Original
    18-Jul-08 h2181 PDF

    93146

    Abstract: main distribution frame telephone main distribution frame
    Text: 2381 66. 9. / PTCTL.R.E Vishay BCcomponents PTC Thermistors, Overload Protection For Telecommunication FEATURES PRIMARY PROTECTION OPTIONAL • • • • SECONDARY PROTECTION +θ +θ PTC PTC subscriber lines SUBSCRIBER LOOP INTERFACE CIRCUIT (SLIC)


    Original
    CCB913 UL1434 08-Apr-05 93146 main distribution frame telephone main distribution frame PDF

    main distribution frame

    Abstract: telephone main distribution frame ptc thermistor for overcurrent protection ptc application note ptc resistor 300 to 500 e 93135 marking r25 Telephone EXchange mdf XGPU2 PTCTL4MR500SBE1
    Text: 2381 66. 9./PTCTL.R.E Vishay BCcomponents PTC Thermistors, Overload Protection For Telecommunication FEATURES PRIMARY PROTECTION OPTIONAL • • • • SECONDARY PROTECTION +θ +θ PTC PTC subscriber lines SUBSCRIBER LOOP INTERFACE CIRCUIT (SLIC)


    Original
    08-Apr-05 main distribution frame telephone main distribution frame ptc thermistor for overcurrent protection ptc application note ptc resistor 300 to 500 e 93135 marking r25 Telephone EXchange mdf XGPU2 PTCTL4MR500SBE1 PDF

    main distribution frame

    Abstract: No abstract text available
    Text: 2381 66. 9./PTCTL.R.E Vishay BCcomponents PTC Thermistors, Overload Protection For Telecommunication FEATURES PRIMARY PROTECTION OPTIONAL +θ PTC subscriber lines +θ PTC voltage clamp +θ • • • • SECONDARY PROTECTION +θ SUBSCRIBER LOOP


    Original
    18-Jul-08 main distribution frame PDF

    Untitled

    Abstract: No abstract text available
    Text: 2381 66. 9./PTCTL.R.E Vishay BCcomponents PTC Thermistors, Overload Protection For Telecommunication FEATURES PRIMARY PROTECTION OPTIONAL • • • • SECONDARY PROTECTION +θ +θ PTC PTC subscriber lines SUBSCRIBER LOOP INTERFACE CIRCUIT (SLIC)


    Original
    08-Apr-05 PDF

    thermistor ptc 18

    Abstract: thermistor 2322 662 98 ptc application note UL1434 main distribution frame 93074
    Text: 2322 66. 9. Vishay BCcomponents PTC Thermistors, Overload Protection For Telecommunication FEATURES PRIMARY PROTECTION OPTIONAL +θ • • • • SECONDARY PROTECTION +θ PTC subscriber lines PTC voltage clamp +θ +θ SUBSCRIBER LOOP INTERFACE CIRCUIT


    Original
    CCB913 UL14RNING CCB614 10-Oct-03 thermistor ptc 18 thermistor 2322 662 98 ptc application note UL1434 main distribution frame 93074 PDF

    ptc Ni 1000

    Abstract: 2322 661
    Text: BCcomponents DATA SHEET 2322 661 97. Surface mount PTC thermistors for overload protection Product specification Supersedes data of 17th May 1999 File under BCcomponents, BC02 2001 Feb 14 BCcomponents Product specification Surface mount PTC thermistors for overload protection


    Original
    CCB833 MSA284 ptc Ni 1000 2322 661 PDF

    PTC SMD

    Abstract: No abstract text available
    Text: BCcomponents DATA SHEET 2322 661 97. Surface mount PTC thermistors for overload protection Product specification Supersedes data of 17th May 1999 File under BCcomponents, BC02 2000 Oct 13 BCcomponents Product specification Surface mount PTC thermistors for overload protection


    Original
    CCB833 MSA284 PTC SMD PDF

    2322 661 16893

    Abstract: ccb61 T 1829-1 CMA110
    Text: BCcomponents DATA SHEET 56 V and 265 V Ts = 120 °C PTC thermistors for overload protection Maintenance type Supersedes data of November 1996 File under BCcomponents, BC02 1999 May 17 BCcomponents Maintenance type PTC thermistors for overload protection


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: 2381 66.9./RTCTL.R.E Vishay BCcomponents 适用于电信应用的 PTC 过载保护热敏电阻 PTC Thermistors, Overload Protection For Telecommunication 特性 SECONDARY PROTECTION PRIMARY PROTECTION OPTIONAL +θ +θ PTC PTC subscriber lines voltage


    Original
    UL1434 2011/65/EU 2002/95/ECã 2002/95/EC 2011/65/EUã JS709A 02-Oct-12 PDF

    NTC THERMISTORS disc nk 0609

    Abstract: NK 0609 thermistor NTC 0609 nF20 IMO Industrial Control ntc 06 0250 ntc 33 0609 ptc 0221 55
    Text: PTC Disc Thermistors Overload Protection: PE – PG Maximum Voltage: 30V / Switching Temperature: 130°C Well suited for overload protection and delayed switching, the PTC thermistors of the 30 V / 130°C series will be of particular interest in automotive and consumer applications.


    Original
    PDF

    philips ptc thermistors

    Abstract: PTC Thermistor MBD132 PTC thermistor PHILIPS PTC PHILIPS ptc relay MBC427 ptc overload protection for telecommunication Electronic Hobby Circuits PHILIPs mains electronic transformers
    Text: Philips Components Introduction to PTC overload protection PTC thermistors FEATURES Domestic appliances • Fast-acting for reliable protection time and time again • Boilers • Well-defined protection trip levels • Shaver socket transformers • Low, medium and high voltage ratings


    Original
    MBD137 MBD136 MBD138 philips ptc thermistors PTC Thermistor MBD132 PTC thermistor PHILIPS PTC PHILIPS ptc relay MBC427 ptc overload protection for telecommunication Electronic Hobby Circuits PHILIPs mains electronic transformers PDF

    main distribution frame

    Abstract: telephone main distribution frame GAS ARRESTOR MDF fire rated
    Text: PTC thermistors for overload protection in telecommunications S+M ceramic PTC thermistors are used world-wide in high quantities in the following telecom applications: – Line card LC to central exchange – Private branch exchanges (PABX) When high currents flow, the electrically loaded PTC is heated up


    Original
    PDF

    PTC thermistor PHILIPS

    Abstract: philips ptc thermistors PTC Thermistor PHILIPs mains electronic transformers Electronic Hobby Circuits
    Text: Philips Components Introduction to PTC overload protection PTC thermistors FEATURES Domestic appliances • Fast-acting for reliable protection time and time again • Boilers • Well-defined protection trip levels • Shaver socket transformers • Low, medium and high voltage ratings


    OCR Scan
    PDF

    philips thermistor 2322 661

    Abstract: philips thermistor 2322 662 philips ptc thermistors 93056 2322 662 93037 PTC PHILIPS 2322 661 PTC thermistor PHILIPS philips thermistor 2322 662 9 thermistor ptc 284 93037 ptc
    Text: Product specification Philips Components PTC overload protection for telecommunication GENERAL Advanced developments in telephony equipment in recent years have radically altered the protection requirements for both exchange and subscriber equipment. The Philips


    OCR Scan
    PDF

    93-0430

    Abstract: philips ptc thermistors ptc overload protection for telecommunication PTC thermistor overcurrent protection philips thermistor 2322 661 thermistor ptc 18 PTC 2322
    Text: Philips Components PTC overload protection for telecommunication GENERAL Advanced developments in telephony equipment in recent years have radically altered the protection requirements for both exchange and subscriber equipment. The Philips Components range of Positive


    OCR Scan
    PDF