Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    LIVE NEUTRAL SHORT Search Results

    LIVE NEUTRAL SHORT Result Highlights (2)

    Part ECAD Model Manufacturer Description Download Buy
    SF-XP85B102DX-000 Amphenol Cables on Demand Amphenol SF-XP85B102DX-000 SFP28 25GBASE-SR Short-Range 850nm Multi-Mode Optical Transceiver Module (Duplex LC Connector) by Amphenol XGIGA [XP85B102DX] Datasheet
    SF-QXP85B402D-000 Amphenol Cables on Demand Amphenol SF-QXP85B402D-000 QSFP28 100GBASE-SR Short-Range 850nm Multi-Mode Optical Transceiver Module (MTP/MPO Connector) by Amphenol XGIGA [QXP85B402D] Datasheet

    LIVE NEUTRAL SHORT Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    230v 9v step down transformer

    Abstract: led 230v application
    Text: Single Phase Power/Energy Metering IC with Tamper Detection sames SA9607M FEATURES + + + + + + Provides direct interface to mechanical counters Monitors Live and Neutral for tamper detection Performs bidirectional energy measurement Various setup modes selectable


    Original
    PDF SA9607M SA9607M 230v 9v step down transformer led 230v application

    230v to 9v step down transformer

    Abstract: 230v 9v step down transformer TRIM POT 10K 230v to 16v step down transformer ,230v to 9v step down transformer VOLTAGE REGULATOR 230V circuit diagram kwh meter circuit diagram resistor 1k ct kwh meter 3 phase analog CHARACTERISTICS DIODE 1N4007
    Text: Single Phase Power/Energy Metering IC with Tamper Detection sames SA2007M FEATURES + Provides direct interface to mechanical counters + Monitors Live and Neutral for tamper detection + Performs bidirectional energy measurement + Various setup modes selectable


    Original
    PDF SA2007M SA2007M 230v to 9v step down transformer 230v 9v step down transformer TRIM POT 10K 230v to 16v step down transformer ,230v to 9v step down transformer VOLTAGE REGULATOR 230V circuit diagram kwh meter circuit diagram resistor 1k ct kwh meter 3 phase analog CHARACTERISTICS DIODE 1N4007

    230v to 9v step down transformer

    Abstract: led 230v application
    Text: Single Phase Power/Energy Metering IC with Tamper Detection sames SA2007M FEATURES + + + + + + Provides direct interface to mechanical counters Monitors Live and Neutral for tamper detection Performs bidirectional energy measurement Various setup modes selectable


    Original
    PDF SA2007M SA2007M 230v to 9v step down transformer led 230v application

    TRIM POT 10K

    Abstract: 230v to 9v step down transformer 78LC05 230v 9v step down transformer 5k trimpot kwh meter IC led light 230v circuit diagram resistor 1K kwh meter analog transformer 230v to 9v
    Text: Single Phase Power/Energy Metering IC with Tamper Detection sames SA2007M FEATURES + Provides direct interface to mechanical counters + Monitors Live and Neutral for tamper detection + Performs bidirectional energy measurement + Various setup modes selectable


    Original
    PDF SA2007M SA2007M TRIM POT 10K 230v to 9v step down transformer 78LC05 230v 9v step down transformer 5k trimpot kwh meter IC led light 230v circuit diagram resistor 1K kwh meter analog transformer 230v to 9v

    Untitled

    Abstract: No abstract text available
    Text: Programmable Single Phase Energy Metering IC with Tamper Detection SA2007P FEATURES + Provides direct interface to mechanical counters + Calibration and setup stored on external EEPROM - no + + + + + + + + trimpots required Monitors both Live and Neutral for tamper detection


    Original
    PDF SA2007P SA2007P

    Wiring Diagram Kwh meter digital

    Abstract: energy meter ic 0038 78LC05 capacitor 2200uf 25v KC113 230v 9v step down transformer earth leakage diagram DIP-20 0038 energy meter SA2007PPA
    Text: Programmable Single Phase Energy Metering IC with Tamper Detection sames SA2007P FEATURES + Provides direct interface to mechanical counters + Calibration and setup stored on external EEPROM - no + + + + + + + + trimpots required Monitors both Live and Neutral for tamper detection


    Original
    PDF SA2007P SA2007P Wiring Diagram Kwh meter digital energy meter ic 0038 78LC05 capacitor 2200uf 25v KC113 230v 9v step down transformer earth leakage diagram DIP-20 0038 energy meter SA2007PPA

    mrc412

    Abstract: NGR8
    Text: NGR www.vishay.com Vishay Milwaukee Reliable Neutral Grounding Resistors, High Current Grid Resistors FEATURES • Tied live design so that there are no floating voltages in the assembly • Rugged shock resistant IP23 rated enclosures available environmental protection


    Original
    PDF 2002/95/EC. 2002/95/EC 2011/65/EU. JS709A 02-Oct-12 mrc412 NGR8

    Untitled

    Abstract: No abstract text available
    Text: Programmable Single Phase Energy Metering IC with Tamper Detection sames SA9607P FEATURES + Provides direct interface to mechanical counters + Calibration and setup stored on external EEPROM - no + + + + trimpots required Monitors both Live and Neutral for tamper detection


    Original
    PDF SA9607P SA9607P

    Wiring Diagram Kwh meter digital

    Abstract: 230v to 9v step down transformer energy meter ic 0038 Wiring Diagram Kwh meter analog capacitor 2200uf 25v energy meters ic 0038 kwh meter circuit diagram 0038 energy meter ct kwh meter 3 phase LED LEVEL METER DRIVER
    Text: Programmable Single Phase Energy Metering IC with Tamper Detection sames SA2007P FEATURES + Provides direct interface to mechanical counters + Calibration and setup stored on external EEPROM - no + + + + + + + + trimpots required Monitors both Live and Neutral for tamper detection


    Original
    PDF SA2007P SA2007P Wiring Diagram Kwh meter digital 230v to 9v step down transformer energy meter ic 0038 Wiring Diagram Kwh meter analog capacitor 2200uf 25v energy meters ic 0038 kwh meter circuit diagram 0038 energy meter ct kwh meter 3 phase LED LEVEL METER DRIVER

    transformer 220V to 24V

    Abstract: three phase bidirectional energy meter capacitor 220nf capacitor 2200uF 16V P10 led module 150KW 1N4007 PM2002DP SA2002 TRANSFORMER 9 to 220V
    Text: Application Note: Energy Meter Evaluation Module sames PM2002DP INTRODUCTION CONNECTORS ON MODULE This application note describes the functionality of the SA2002D metering integrated circuit using the PM2002DP evaluation module. The PM2002DP module connects directly to live and neutral


    Original
    PDF PM2002DP SA2002D PM2002DP SA2002 transformer 220V to 24V three phase bidirectional energy meter capacitor 220nf capacitor 2200uF 16V P10 led module 150KW 1N4007 TRANSFORMER 9 to 220V

    transformer 220V to 24V

    Abstract: capacitor 220nf capacitor 2200uF 16V 220v phase shift circuit diagram power LED 4W 220v diagram bidirectional energy meter 3 phase energy meter circuit diagram with CT power LED 4W 220v shunt resistor current motor 220v to 24V transformer
    Text: Application Note: Energy Meter Evaluation Module sames PM2002DP INTRODUCTION CONNECTORS ON MODULE This application note describes the functionality of the SA2002D metering integrated circuit using the PM2002DP evaluation module. The PM2002DP module connects directly to live and neutral


    Original
    PDF PM2002DP SA2002D PM2002DP SA2002 transformer 220V to 24V capacitor 220nf capacitor 2200uF 16V 220v phase shift circuit diagram power LED 4W 220v diagram bidirectional energy meter 3 phase energy meter circuit diagram with CT power LED 4W 220v shunt resistor current motor 220v to 24V transformer

    78LC05

    Abstract: 230v to 9v step down transformer 230v ac motor drive circuit diagram 100uF 16V Electrolytic Capacitor 1n4007 diode 230v 9v step down transformer kwh meter circuit diagram SA9607MPA capacitor 220nf pin configuration diode 1N4007
    Text: Single Phase Power/Energy Metering IC with Tamper Detection SA9607M FEATURES • Provides direct interface to mechanical counters ■ Total power consumption rating below 25mW ■ Monitors Live and Neutral for tamper detection ■ Adaptable to different types of sensors


    Original
    PDF SA9607M SA9607M 78LC05 230v to 9v step down transformer 230v ac motor drive circuit diagram 100uF 16V Electrolytic Capacitor 1n4007 diode 230v 9v step down transformer kwh meter circuit diagram SA9607MPA capacitor 220nf pin configuration diode 1N4007

    Untitled

    Abstract: No abstract text available
    Text: STPM01 Programmable single phase energy metering IC with tamper detection Features • Active, reactive, apparent energies and RMS values ■ Ripple free active energy pulsed output ■ Live and neutral monitoring for tamper detection ■ Easy and fast digital calibration in only one


    Original
    PDF STPM01 IEC62052-11, IEC620532x TSSOP20 STPM01

    STPM01FTR

    Abstract: energy meter ic 0038 AN2317 Rogowski Coil design STPM01 zero crossing detector 50Hz 230v STPM01 crossing IEC62052-11 AN2299 mb1060
    Text: STPM01 Programmable single phase energy metering IC with tamper detection Features • Active, reactive, apparent energies and RMS values ■ Ripple free active energy pulsed output ■ Live and neutral monitoring for tamper detection ■ Easy and fast digital calibration in only one


    Original
    PDF STPM01 IEC62052-11, IEC620532x STPM01 STPM01FTR energy meter ic 0038 AN2317 Rogowski Coil design zero crossing detector 50Hz 230v STPM01 crossing IEC62052-11 AN2299 mb1060

    STPM01FTR

    Abstract: 06-Feb-2006 STPM01 crossing
    Text: STPM01 Programmable single phase energy metering IC with tamper detection Features • Active, reactive, apparent energies and RMS values ■ Ripple free active energy pulsed output ■ Live and neutral monitoring for tamper detection ■ Easy and fast digital calibration in only one


    Original
    PDF STPM01 IEC62052-11, IEC620532x STPM01FTR 06-Feb-2006 STPM01 crossing

    STPM01

    Abstract: energy meter ic 0038 ci DT 8211 Rogowski Coil design STPM01 crossing IEC62052-11 STPM01FTR 230v ac emi filter
    Text: STPM01 Programmable single phase energy metering IC with tamper detection Features • Active, reactive, apparent energies and RMS values ■ Ripple free active energy pulsed output ■ Live and neutral monitoring for tamper detection ■ Easy and fast digital calibration in only one


    Original
    PDF STPM01 IEC62052-11, IEC620532x STPM01 energy meter ic 0038 ci DT 8211 Rogowski Coil design STPM01 crossing IEC62052-11 STPM01FTR 230v ac emi filter

    schematic diagram of energy saving device

    Abstract: ci DT 8211 zero crossing detector 50Hz 230v STPM01FTR zero crossing detector ic with 230v Rogowski 110v to 5v dc schematic step down transformer to convert 230v to 20v 230v dc motor drive circuit diagram Rogowski Coil design
    Text: STPM01 Programmable single phase energy metering IC with tamper detection Feature summary • Active, reactive, apparent energies and RMS values ■ Ripple free active energy pulsed output ■ Live and neutral monitoring for tamper detection ■ Easy and fast digital calibration in only one


    Original
    PDF STPM01 TSSOP20 IEC62052-11, IEC620532x STPM01 schematic diagram of energy saving device ci DT 8211 zero crossing detector 50Hz 230v STPM01FTR zero crossing detector ic with 230v Rogowski 110v to 5v dc schematic step down transformer to convert 230v to 20v 230v dc motor drive circuit diagram Rogowski Coil design

    STPM01FTR

    Abstract: transformer pst 39
    Text: STPM01 Programmable single phase energy metering IC with tamper detection Feature summary • Active, reactive, apparent energies and RMS values ■ Ripple free active energy pulsed output ■ Live and neutral monitoring for tamper detection ■ Easy and fast digital calibration in only one


    Original
    PDF STPM01 IEC62052-11, IEC620532x STPM01FTR transformer pst 39

    energy meter ic 0038

    Abstract: STPM01FTR STPM01 crossing kwh meter pln convert 230v adc to 5v dc without using transform rogowski coil integrator pst 39 transformer zero crossing detector ic with 230v
    Text: STPM01 PROGRAMMABLE SINGLE PHASE ENERGY METERING IC WITH TAMPER DETECTION • ■ ■ ■ ■ ■ ■ ■ ■ ■ ACTIVE, REACTIVE, APPARENT ENERGIES AND RMS VALUES RIPPLE FREE ACTIVE ENERGY PULSED OUTPUT LIVE AND NEUTRAL MONITORING FOR TAMPER DETECTION EASY AND FAST DIGITAL CALIBRATION IN


    Original
    PDF STPM01 IEC62052-11, IEC62053-2X STPM01 energy meter ic 0038 STPM01FTR STPM01 crossing kwh meter pln convert 230v adc to 5v dc without using transform rogowski coil integrator pst 39 transformer zero crossing detector ic with 230v

    CSA-1402C

    Abstract: UL-1950 1-480426-0 1402c
    Text: 50 Watt Fully Enclosed 90-130 VAC or 180-260 VAC Input-Jumper Selectable Short Circuit Protection Isolated Outputs Features 90-130 VAC or 180-260 VAC input Meets FCC/VDE, EMI requirements 100% burn-in testing Meets or exceeds UL-CSA requirements Hi reliability


    Original
    PDF -12VDC -15VDC 12VDC 15VDC CSA-1402C UL-1950 1-480426-0 1402c

    Untitled

    Abstract: No abstract text available
    Text: Appendix C Glossary A sym m etric Com m on M o d e In te rfe re n ce Common mode noise manifests itself as a current, which is in phase and magnitude, in the live and neutral wires of a circuit and returns via ground. This produces a noise voltage between live/neutral and ground.


    OCR Scan
    PDF 900MHz 333mm 250mm

    Untitled

    Abstract: No abstract text available
    Text: SERIES OFB Fully Enclosed AC-DC Sw itchers 50-130 Watt Fully Enclosed 90-130 VAC or 180-260 VAC Input-Jumper Selectable Short Circuit Protection Isolated Outputs FEATURES: • 90-130 VAC or 180-260 VAC Input • Meets FCC/VDE, EMI requirement* • 100% bum-in testing


    OCR Scan
    PDF 0FB13-6M OFB13-7M

    Untitled

    Abstract: No abstract text available
    Text: SER IES OFJ AC-DC Sw itchers 100-200 W att PCB-L-Bracket Construction 90-130 VAC or 180-260 VAC Input-Jum per Selectable Short C ircuit Protection Isolated Outputs FEATURES: • 90-130 VAC or 180-260 VAC input • Meets FCC/VDE, EMI requirements • 100% bum-in testing


    OCR Scan
    PDF 10-Input FJ10-1D HLSC73A

    pico electronics transformers

    Abstract: No abstract text available
    Text: SER IES OFJ AC-DC S w itch ers 100-200 W att PCB-L-Bracket Construction 90-130 VAC or 180-260 VAC Input-Jum per S electable Short C ircuit Protection Isolated Outputs FEATURES: • 90-130 VAC or 180-260 VAC input • Meets FCC/VDE, EMI requirements • 100% burn-in testing


    OCR Scan
    PDF 10-Input pico electronics transformers