Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    KVP 0.7 A M Search Results

    KVP 0.7 A M Result Highlights (6)

    Part ECAD Model Manufacturer Description Download Buy
    EVAL-ADN4650EB1Z Analog Devices ADN4650 Evaluation Board Visit Analog Devices Buy
    ADN4651BRSZ-RL7 Analog Devices 3.75kVrms LVDS Iso 600Mbps Dua Visit Analog Devices Buy
    ADN4692EBRZ-RL7 Analog Devices MLVDS Xcvr,FD,100M Type 1 Rx,E Visit Analog Devices Buy
    ADN4695EBRZ Analog Devices MLVDS Xcvr,FD,100M Type 2 Rx,E Visit Analog Devices Buy
    EVAL-ADN4652EB1Z Analog Devices ADN4652 SOIC-W Eval Board Visit Analog Devices Buy
    ADN4651BRSZ Analog Devices 3.75kVrms LVDS Iso 600Mbps Dua Visit Analog Devices Buy

    KVP 0.7 A M Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Untitled

    Abstract: No abstract text available
    Text: T. 050120, T. 050200 www.vishay.com Vishay Draloric RF Power Pot Capacitors with Mounting Tags, Class 1 Ceramic FEATURES • High reliability • Multiple terminals • High capacitance values APPLICATIONS • Induction and dielectric heating • Antenna units


    Original
    PDF 2002/95/EC. 2002/95/EC 2011/65/EU. JS709A 02-Oct-12

    kvp 03

    Abstract: feedthrough capacitors DWA 045150 030090 KVP18 DF 045120 DF 030070
    Text: DF 030., DWA 045. Vishay Draloric Feed-Through Capacitors, Tag Mounting DF 030070 7 KVP DF 030090 7 KVP DF 030110 7 KVP DWA 045120 8 KVP to 16 KVP DWA 045150 8 KVP to 16 KVP 18 + 1 0.709 + 0.04 ø 5.2 + 0.2 Holes (0.205 + 0.008) 20 - 1 (0.787 12 x 0.7


    Original
    PDF 18-Jul-08 kvp 03 feedthrough capacitors DWA 045150 030090 KVP18 DF 045120 DF 030070

    DWA45

    Abstract: No abstract text available
    Text: DWA 045120, DWA 045150 www.vishay.com Vishay Draloric RF Power Feed-Through Capacitors with Mounting Tags, Class 1 Ceramic FEATURES • Geometry minimizes inductance • Wide range of capacitance values • High feed-through currents APPLICATIONS Filtering purposes in industrial and medical RF power


    Original
    PDF 2002/95/EC. 2002/95/EC 2011/65/EU. JS709A 02-Oct-12 DWA45

    Untitled

    Abstract: No abstract text available
    Text: DF 045120, DF 045155 www.vishay.com Vishay Draloric RF Power Feed-Through Capacitors with Mounting Tags, Class 1 Ceramic FEATURES • Geometry minimizes inductance • Wide range of capacitance values • High voltage ratings APPLICATIONS Filtering purposes in industrial and medical RF power


    Original
    PDF 2002/95/EC. 2002/95/EC 2011/65/EU. JS709A 02-Oct-12

    16KVp

    Abstract: DF 045120 DF 030070 DWA 045150
    Text: DF 030., DWA 045. Vishay Draloric Feed-Through Capacitors, Tag Mounting DF 030070 DF 030090 DF 030110 7KVp 7KVp 7KVp DWA 045120 DWA 045150 18 + 1 0.709 + 0.04 ø 5.2 + 0.2 Holes (0.205 + 0.008) 8KVp to 16KVp 8KVp to 16KVp 20 - 1 (0.787 12 x 0.7 (0.472 x 0.028)


    Original
    PDF 16KVp 08-Apr-05 16KVp DF 045120 DF 030070 DWA 045150

    power supply for magnetron

    Abstract: magnetron tube data sheet magnetron* -coaxial
    Text: NATIONAL NL10251-4LOW Description: Continuous wave magnetron, fixed frequency. ABSOLUTE MAXIMUM RATINGS: ITEM SYMBOL Filament Surge Current Filament Voltage,Stand-by Filament Voltage,Operation Pre-heating Time Peak Anode Voltage Peak Anode Current Average Anode Current


    Original
    PDF NL10251-4LOW 120secMin power supply for magnetron magnetron tube data sheet magnetron* -coaxial

    T. 050120

    Abstract: No abstract text available
    Text: T. 050120, T. 050200 Vishay Draloric Pot Capacitors, Tag & Flange Mounting 6.2 + 0.4 0.244 + 0.016 Ø 73 (2.874 DIA) Ø 50 (1.969 DIA) L1 (0.031) 20 x 0.7 (0.787 x 0.028) Ø 73 (2.874 DIA) L2 Ø 50 (1.969 DIA) 1 (0.04) 32 + 3 (1.260 + 0.118) 0.8 35 ± 2


    Original
    PDF 12KVp 05020ed 08-Apr-05 T. 050120

    sensor x-ray

    Abstract: mosfet ssd
    Text: IMAGE SENSOR CCD area image sensor S7199-01 Front-illuminated FFT-CCDs for X-ray imaging S7199-01 is a family of FFT-CCD image sensors specifically designed for X-ray imaging. FOS Fiber Optic plate with Scintillator that converts X-ray into visible-light is mounted on a CCD chip, which enables S7199-01 to acquire the X-ray imaging. Two CCD


    Original
    PDF S7199-01 S7199-01 SE-171 KMPD1077E08 sensor x-ray mosfet ssd

    S1533

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S7199-01 Front-illuminated FFT-CCDs for X-ray imaging S7199-01 is a family of FFT-CCD image sensors specifically designed for X-ray imaging. FOS Fiber Optic plate with Scintillator that converts X-ray into visible-light is mounted on a CCD chip, which enables S7199-01 to acquire the X-ray imaging. Two CCD


    Original
    PDF S7199-01 S7199-01 SE-171 KMPD1077E06 S1533

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S7199-01 Front-illuminated FFT-CCDs for X-ray imaging S7199-01 is a family of FFT-CCD image sensors specifically designed for X-ray imaging. FOS Fiber Optic plate with Scintillator that converts X-ray into visible-light is mounted on a CCD chip, which enables S7199-01 to acquire the X-ray imaging. Two CCD


    Original
    PDF S7199-01 S7199-01 SE-171 KMPD1077E05

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S7199-01 Front-illuminated FFT-CCDs for X-ray imaging S7199-01 is a family of FFT-CCD image sensors specifically designed for X-ray imaging. FOS Fiber Optic plate with Scintillator that converts X-ray into visible-light is mounted on a CCD chip, which enables S7199-01 to acquire the X-ray imaging. Two CCD


    Original
    PDF S7199-01 S7199-01 SE-171 KMPD1077E07

    sensor x-ray

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8658-01 Front-illuminated FFT-CCD for X-ray imaging S8658-01 is a FFT-CCD area image sensor specifically developed for X-ray imaging. Since a FOS Fiber Optic plate with Scintillator to convert Xrays into visible light is mounted on the CCD chip, X-ray images can be captured in fine detail. Three CCD chips are linearly arranged in close


    Original
    PDF S8658-01 S8658-01 SE-171 KMPD1078E05 sensor x-ray

    sp511401a

    Abstract: No abstract text available
    Text: 05426 SP511401A Only One Name Means ProTek’Tion smart power protector for ac ports Description The SP511401A is a unique multi-function resettable protective module, specifically designed for the small power AC port overall safety protection. FUSE Features


    Original
    PDF SP511401A SP511401A

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8658-01 Front-illuminated FFT-CCD for X-ray imaging S8658-01 is a FFT-CCD area image sensor specifically developed for X-ray imaging. Since a FOS Fiber Optic plate with Scintillator to convert Xrays into visible light is mounted on the CCD chip, X-ray images can be captured in fine detail. Three CCD chips are linearly arranged in close


    Original
    PDF S8658-01 S8658-01 KMPD1078E09

    Untitled

    Abstract: No abstract text available
    Text: CCD area image sensors S8980 S10810-11 Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5


    Original
    PDF S8980 S10810-11 S8980 S10810-11 S8980, incorporate53 B1201, KMPD1123E06

    Untitled

    Abstract: No abstract text available
    Text: CCD area image sensors S10814 S10811-11 Front-illuminated FFT-CCD for X-ray imaging The S10814 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S10814 has about 2 mega 1700 x 1200 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as


    Original
    PDF S10814 S10811-11 S10814 S10811-11 S10814, KMPD1124E05

    pin out mdr 50 pin CONNECTOR

    Abstract: No abstract text available
    Text: CCD area image sensors S8980 S10810-11 Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5


    Original
    PDF S8980 S10810-11 S10810-11 S8980, KMPD1123E05 pin out mdr 50 pin CONNECTOR

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S7199-01 Front-illuminated FFT-CCDs for X-ray imaging S7199-01 is a family of FFT-CCD image sensors specifically designed for X-ray imaging. A FOS Fiber Optic plate with Scintillator that converts X-ray into visible-light is mounted on the CCD chip, which enables S7199-01 to acquire the X-ray


    Original
    PDF S7199-01 S7199-01 SE-171 KMPD1077E11

    draloric

    Abstract: T. 085120
    Text: T. 085120 Vishay Draloric Pot Capacitors, Tag & Flange Mounting TA TB 10KVp to 15KVp 10KVp to 15KVp TE 10KVp to 15KVp 12 x 0.7 0.472 x 0.028 5.2 ± 0.2 (0.205 ± 0.008) 123 ± 2 (4.843 ± 0.08) 60 ± 2 (2.362 ± 0.08) 1.0 (0.04) 1.0 (0.04) 120 (4.724) 60 ± 2


    Original
    PDF 10KVp 15KVp 08-Apr-05 draloric T. 085120

    S1503

    Abstract: 5343
    Text: CCD area image sensors S8980 S10810-11 Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5


    Original
    PDF S8980 S10810-11 S10810-11 S8980, KMPD1123E04 S1503 5343

    TDI ccd sensor

    Abstract: ccd tdi binning
    Text: TDI-CCD area image sensor S7199-01/-01F Image sensor with a long, narrow photosensitive area for X-ray imaging The S7199-01 is a front-illuminated FFT-CCD image sensor developed for X-ray imaging. An FOS Fiber Optic plate with Scintillator sensitive to X-rays is directly coupled to the CCD chips, allowing X-ray imaging with high sensitivity. Two CCD


    Original
    PDF S7199-01/-01F S7199-01 S7199-01F) KMPD0177E12 TDI ccd sensor ccd tdi binning

    S10811-11

    Abstract: S10811
    Text: CCD area image sensors S10814 S10811-11 Front-illuminated FFT-CCD for X-ray imaging The S10814 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S10814 has about 2 mega 1700 x 1200 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as


    Original
    PDF S10814 S10811-11 S10811-11 S10814, SE-171 KMPD1124E04 S10811

    Untitled

    Abstract: No abstract text available
    Text: CCD area image sensors S8980 S10810-11 Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5


    Original
    PDF S8980 S10810-11 S10810-11 S8980, SE-171 KMPD1123E03

    Untitled

    Abstract: No abstract text available
    Text: CCD area image sensors S8980 S10810-11 Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5


    Original
    PDF S8980 S10810-11 S10810-11 S8980, KMPD1123E04