DN40 PN16
Abstract: ISO2852 hart communicator AISI316L din 16288
Text: FlexBar 3501 Pressure Transmitter 4.20 mA, 2-wire transmitter, HART communication Optional Stainless steel heavy duty housing with LC-Display (Optional) Configurable span, unit, damping and linearisation Turn down 25:1 Accuracy better than 0.1% Zero point adjustment
|
Original
|
PDF
|
UK/2009-02-20
DN40 PN16
ISO2852
hart communicator
AISI316L
din 16288
|
FMCW
Abstract: No abstract text available
Text: m o c . o c l e v i n . w w 2012/2 w PRODUCT CATALOGUE PRODUCT CATALOGUE 2012/2 SUBSIDIARY AND DISTRIBUTION NETWORK To find a local NIVELCO representation, please check distribution page on NIVELCO website! CONTACT NIVELCO To contact NIVELCO, please use contact page on NIVELCO website!
|
Original
|
PDF
|
H-1043
NIVIS01
nikat11a0604d
FMCW
|
ETP08
Abstract: water BALL VALVE ABB pressure transmitter etp08 ABB sensor absolute pressure ETP08-XXXX "Pressure transmitter" type 501 ISO2852 Varivent P1093 DIN11851
Text: ETP08 Electronic Transmitter for Pressure and Level The ETP08 is a series of pressure transmitters with a wide range of connections to suit most applications. The transmitters can measure liquids, gases, vapours and can be used for hydrostatic level measurements in open
|
Original
|
PDF
|
ETP08
ETP08
0945en0209
water BALL VALVE
ABB pressure transmitter etp08
ABB sensor absolute pressure
ETP08-XXXX
"Pressure transmitter" type 501
ISO2852
Varivent
P1093
DIN11851
|
Untitled
Abstract: No abstract text available
Text: PBMH Fully autoclavable pressure transmitter for hygienic applications Main benefits Fully autoclavable pressure Excellent active temperature sensor for common sterilization processes High temperature resistance for SIP and CIP processes
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Operators instructions CleverLevel switch, LFFS CleverLevel switch, type LFFS is an universal level switch, which can be used for all applications in liquids and solids with a DK-value above 1,5 Safety instructions This instrument is constructed and tested according to the current EUdirectives and packed in technically safe condition. In order to maintain
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Siemens AG 2014 Level measurement Continuous level measurement — Guided wave radar transmitters SITRANS LG series • Overview ■ Benefits • • • • • • • • • 4 • The Siemens SITRANS LG series are guided wave radar transmitters for level, level/interface, and volume measurement of
|
Original
|
PDF
|
|
antena microondas
Abstract: circuito sensor capacitivo Denso radar sensores capacitivos R2N P1F transistor A5E024 bocina transistor J1F LUT400 SENSORES INDUCTIVOS
Text: 4 Siemens AG 2014 Medida de nivel 4/2 Sinopsis de productos 4/9 Detección de nivel Sensores capacitivos Medición continua continuación Accesorios para sistemas ultrasónicos 4/185 – Bridas de fijación EA 4/187 – Soportes de montaje FMS 4/189 – Sensor de temperatura TS-3
|
Original
|
PDF
|
LR200
CLS300
LR250
7ML1830-1HA
7ML1830-1MC
7ML1830-1MM
antena microondas
circuito sensor capacitivo
Denso radar
sensores capacitivos
R2N P1F transistor
A5E024
bocina
transistor J1F
LUT400
SENSORES INDUCTIVOS
|
abb magmaster
Abstract: 9pin rs232 D-connector to 25 pin rs422 ISO2852 material safety for nitrile rubber magmaster Clover Display 220R HART 375 abb temperature Transmitter abb magmaster transmitter
Text: MagMaster Electromagnetic Flowmeter – Hygienic/Sanitary Specification DataFile • Unrivalled, fully traceable flow performance, ±0.2% accuracy. Operable flow range: 1000 : 1 – ensures precise revenue measurement; superior process control ■ Approved hygienic/sanitary design with
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Membran-Druckmittler mit Nahrungsmittelanschluss Baureihe DAxx Druckmittler ganz aus Edelstahl mit frontbündiger Membrane Schneller Anbau und Abbau Mess-Stoff-Temperatur bis 150°C je nach Druck, Gerätetyp und Befestigung 3-A N°1118 Zulassung - DANC, sterilization in place SIP , cleaning in place (CIP)
|
Original
|
PDF
|
C276/2
DE/02-2015
|
ISO2852
Abstract: MX35/37/51/257 MX35/51
Text: Chemical seals for hygienic pressure applications DAxx series All stainless steel, flush diaphragm Rapid assembly and disassembly Fluid temperature up to 150°C depending on pressure, measuring device or mounting. 3-A authorization N°1118 : - DANC, sterilization in place (SIP), cleaning in place (CIP)
|
Original
|
PDF
|
C276/2
UK/12-2014
ISO2852
MX35/37/51/257
MX35/51
|
ISO2852
Abstract: No abstract text available
Text: PBMH Fully welded pressure transmitter for hygienic applications Main benefits High temperature resistance for SIP and CIP processes Surface roughness of flush process connection Ra ≤ 0.8 for highest hygienic requirements Fully welded and compact
|
Original
|
PDF
|
|
ABB pressure transmitter etp80
Abstract: ETP80 ISO2852 4435 B 4435 "Pressure transmitter" type 501 HART 375 DIN11851 DIN2656 BALL VALVE
Text: ETP80 Electronic Transmitter for Pressure, Differential Pressure and Level The ETP80 is a series of pressure transmitters with a wide range of connections to suit most applications. The transmitters can measure liquids, gases and vapour. The ETP80 is durable against
|
Original
|
PDF
|
ETP80
ETP80
0996en0209
ABB pressure transmitter etp80
ISO2852
4435 B
4435
"Pressure transmitter" type 501
HART 375
DIN11851
DIN2656
BALL VALVE
|