VDE 0551 EN 60 742
Abstract: block VDE 0551 EN 60 742
Text: Block Transformers Visit Block TransformerÕs Website at www.blockusa.com FL Range Dual Primary 115 V + 115 V Low Profile Ñ NEW Ñ Features c Design: Safety Isolating Transformer to VDE 0551, EN 60 742, IEC 742, IEC 61 558 c Test Voltage: Between Input and Output Circuits 5000 V, 50 Hz
|
Original
|
AVC10/2/18
AVC10/2/24
AVC16/2/6
AVC16/2/8
AVC16/2/9
AVC16/2/12
AVC16/2/15
AVC16/2/18
AVC16/2/24
c1033
VDE 0551 EN 60 742
block VDE 0551 EN 60 742
|
PDF
|
VDE 0551 EN 60 742
Abstract: block transformers block VDE 0551 EN 60 742 IEC-742 TRANSFORMER 1034.txt vde 0551
Text: Block Transformers Visit Block TransformerÕs Website at www.blockusa.com Ñ NEW Ñ AVCM Range Dual Primary 115 V + 115 V Non Short Circuit Proof Features c Design: Safety Isolating Transformer to VDE 0551, EN 60 742, IEC 742 c Test Voltage: Between Input and Output Circuit 5000 V, 50 Hz
|
Original
|
100-Up
AVCM25/2/6
AVCM25/2/2
VDE 0551 EN 60 742
block transformers
block VDE 0551 EN 60 742
IEC-742 TRANSFORMER
1034.txt
vde 0551
|
PDF
|
block VDE 0551 EN 60742
Abstract: transformer vde 0551 IEC-742 TRANSFORMER block VDE 0551 EN 60 742 VDE 0551 EN 60 742 24v transformer windings EN 60 742 transformer
Text: Data sheet: Stabilized DC Power Supply Type GLS - Description . : Compact stabilized dc power supply with integrated safety isolating transformer to VDE 0551, DIN EN 60742, IEC 742 in accordance with
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Module no:2700010 LabelId:2700010 Operator:Phoenix 17:10:19, Donnerstag, 28. Juni 2001 TRK 1,5 Terminal width 16 rigid IEC solid 2 [mm ] EN 60 742 flexible stranded AWG I U [A] [V] 6 1) 0.5-1.5 0.75-1.5 20-16 H CAEF LR/BV/NV/NKK Description Assembly Transformer terminal
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Module no:3002775 LabelId:3002775 Operator:Phoenix 18:44:19, Donnerstag, 28. Juni 2001 VTRKZ 4-SI Fuse terminal block with strain relief Terminal width 12.4 IEC rigid 2 [mm ] solid EN 60 742 0.2-6 flexible stranded AWG 0.2-4 Potting fuse terminal block,
|
Original
|
10-section,
|
PDF
|
IEC-742 TRANSFORMER
Abstract: EN 60 742 transformer iec 742 EN60742
Text: Module no:2702351 LabelId:2702351 Operator:Phoenix 17:11:36, Donnerstag, 28. Juni 2001 TRK 4-PE Terminal width 7.6 IEC rigid 2 [mm ] solid EN 60 742 0.2-6 flexible stranded AWG 0.2-4 24-12 Description Transformer PE terminal block, is directly welded on the laminated core of the
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Module no:3001996 LabelId:3001996 Operator:Phoenix 18:43:11, Donnerstag, 28. Juni 2001 VTRK 4-SI Fuse terminal block Terminal width 12.4 IEC rigid 2 [mm ] solid EN 60 742 0.2-6 flexible stranded AWG 0.2-4 24-10 Potting fuse terminal block, as above, however, with
|
Original
|
10-section,
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Module no:2702092 LabelId:2702092 Operator:Phoenix 17:10:56, Donnerstag, 28. Juni 2001 TRK 4-SL Green-yellow ground terminal block Terminal width 12 IEC rigid solid 2 [mm ] EN 60 742 HE 0.75-4 flexible stranded AWG 1-4 18-12 BV/NV Description Housing color
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Module no:3004980 LabelId:3004980 Operator:Phoenix 18:50:21, Donnerstag, 28. Juni 2001 VTRK 4 Terminal width 12.4 IEC rigid [mm ] solid 2 EN 60 742 flexible stranded AWG 0.2-6 0.2-4 24-10 I U [A] [V] 25 1) 1 ) Voltage data can only be quoted in connection with transformer.
|
Original
|
10-section,
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Module no:2702018 LabelId:2702018 Operator:Phoenix 17:10:50, Donnerstag, 28. Juni 2001 TRK 4/TRK 4-FS Terminal width 13 rigid IEC solid 2 [mm ] EN 60 742 0.75-4 H CAEF flexible stranded AWG 1-4 18-12 I U [A] [V] 16 1) LR/BV/NV/MRS/NKK Description Transformer terminal block,
|
Original
|
Su47-1
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Module no:3001967 LabelId:3001967 Operator:Phoenix 18:42:53, Donnerstag, 28. Juni 2001 VTRKZ 4 Terminal block with strain relief Terminal width 12.4 IEC rigid [mm ] solid 2 EN 60 742 flexible stranded AWG 0.2-6 0.2-4 24-10 I U [A] [V] 25 1) 1 ) Voltage data can only be quoted in connection with transformer.
|
Original
|
10-section,
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Module no:2703525 LabelId:2703525 Operator:Phoenix 17:12:00, Donnerstag, 28. Juni 2001 TRKS 10 with internal screw connection Terminal width 10.2 IEC 2 [mm ] EN 60 742 H CA rigid solid flexible stranded AWG 0.5-16 0.5-10 20-6 I U [A] [V] 40 1) LR/MRS Type
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Module no:2703017 LabelId:2703017 Operator:Phoenix 17:11:48, Donnerstag, 28. Juni 2001 TRK 10 Terminal width 18.5 IEC rigid solid 2 [mm ] EN 60 742 2.5-10 H CAEF flexible stranded AWG 4-10 14-8 I U [A] [V] 32 1) LR/BV/NV/MRS/NKK Description Housing color
|
Original
|
|
PDF
|
IEC-742 TRANSFORMER
Abstract: No abstract text available
Text: Module no:2702254 LabelId:2702254 Operator:Phoenix 17:11:23, Donnerstag, 28. Juni 2001 TRKS 4/TRKSD 4 TRKS 4: Terminal width 7.5 TRKSD 4: Terminal width 15 TRKS 4/3: Terminal width 22.5 IEC rigid [mm ] solid 2 EN 60 742 0.2-6 H CAE flexible stranded AWG
|
Original
|
|
PDF
|
|
IEC-742 TRANSFORMER
Abstract: No abstract text available
Text: Module no:2701019 LabelId:2701019 Operator:Phoenix 17:10:31, Donnerstag, 28. Juni 2001 TRK 2,5/TRK 2,5-FS Terminal width 20 IEC rigid solid 2 [mm ] EN 60 742 flexible stranded AWG 0.75-2.5 H CAEF 1-2.5 18-14 I U [A] [V] 10 1) LR/BV/NV/NKK Description Assembly
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Module no:2700023 LabelId:2700023 Operator:Phoenix 17:10:25, Donnerstag, 28. Juni 2001 TRK 1,5-FS with 2.8 mm tab connection Terminal width 16 IEC rigid solid 2 [mm ] EN 60 742 flexible stranded AWG 0.5-1.5 0.75-1.5 20-16 H CAF I U [A] [V] 6 1) LR/BV/NV/NKK
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Module no:3001983 LabelId:3001983 Operator:Phoenix 18:43:04, Donnerstag, 28. Juni 2001 VTRK 4-SI/C for flat-type fuse cartridges Terminal width 12.4 IEC rigid flexible 2 [mm ] solid EN 60 742 stranded AWG 0.2-6 0.2-4 24-10 I U [A] [V] 1 10 ) 2 250 ) CA Order No.
|
Original
|
10-section,
|
PDF
|
IEC-742 TRANSFORMER
Abstract: 05511
Text: Module no:2702199 LabelId:2702199 Operator:Phoenix 17:11:10, Donnerstag, 28. Juni 2001 TRKS 4-PE Terminal width 12.5 IEC rigid 2 [mm ] solid EN 60 742 0.2-6 H CAG flexible stranded AWG 0.2-4 24-12 LR/MRS Color Type Order No. Pcs. Pkt. green-yellow TRKS 4-PE
|
Original
|
|
PDF
|
block VDE 0551 EN 60 742
Abstract: X-1875 VDE 0551 EN 60 742
Text: BLOCK Flachtransformator FL Low profile transformer FL 1,4 VA bis 52 VA, PRI: 2 x 115 V 1,4 VA to 52 VA, PRI: 2 x 115 V Prinzipschaltbild C ircuit diagram Sicherheits-Transformator nach DIN EN 60 742, VDE0551, EN 60 742, IEC 742, IEC 61 558 Prüfzeichen nach Tabelle
|
OCR Scan
|
VDE0551,
2x115V
block VDE 0551 EN 60 742
X-1875
VDE 0551 EN 60 742
|
PDF
|
bs 3535
Abstract: AVEL G101000252
Text: EURORANGE TRANSFORMERS 230/240Vac PRIMARY TOROIDAL CONSTRUCTION HORIZONTAL OR VERTICAL FIXING OPTION THERMALLY PROTECTED PRIMARY FULLY ENCAPSULATED TO UL 94VO DUAL SECONDARIES LOW MAGNETIC FIELD LOW SURFACE TEMPERATURE CONFORMS TO EN 60/742 BS 3535 IEC 742 VDE 0551 UL 506
|
OCR Scan
|
230/240Vac
bs 3535
AVEL
G101000252
|
PDF
|
vde 0550
Abstract: VDE 0551 EN 60 742 VDE 0551 t 60 e transformer vde 0551 EE20 bobbin 10 pin RH1034-1.2
Text: Printtransformatoren PCB transformers kurzschlußfester Printtransformator VB 0,35 VA bis 3,2 VA, PRI 230 V short circuit proof PCB transformer VB 0,35 VA to 3,2 VA, PRI230 V Ausführung Sicherheitstransformator nach VDE 0551, EN 60 742, IEC 742 Design Prüfzeichen
|
OCR Scan
|
PRI230
vde 0550
VDE 0551 EN 60 742
VDE 0551 t 60 e
transformer vde 0551
EE20 bobbin 10 pin
RH1034-1.2
|
PDF
|
vde 0551 en60742
Abstract: transformer vde 0551 en60742 VDE 0551 t 60 e vde 0550 transformer vde 0551 A0833 Transformer EN60742 230 v nach VDE 0551 VDE0550 Transformer 42 v EN60742
Text: Printtransformatoren 40 Printtransformator VCM montierbar 5 VA bis 50 VA, PRI: 230 V PCB transformers PCB transformer VCM with mounting brackets 5 VA to 50 VA, PRI: 230 V Ausführung Sicherheitstransformator nach VDE 05S1, EN 60 742, IEC 742 Design Prüfzeichen
|
OCR Scan
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: INTERNATIONAL STYLE TRANSFORMERS MCl’s new American manufactured 4-50 Series transformers meet the require ments of UL506, CSA22.2 #6, EN 60742, and IEC 742. These transformers are 100% tested, including a 4000 VRMS Hipot. Rugged or fast on screw type shock
|
OCR Scan
|
UL506,
CSA22
250VA
|
PDF
|
IRF 810
Abstract: No abstract text available
Text: TRANSFORMERS File #LR69222 File 810/89 File #LR69223 811/89 VDE 0551,0806 For PC Board, Solid-State Power, Control, and Instrumentation Applications. "tamura File TUV Fite 810/89 #E79781 n iu n n n T n n . . 811/89 UL506 IEC 742 EN60950 File #138028 UL1411
|
OCR Scan
|
LR69222
LR69223
E79781
UL506
EN60950
UL1411
15V/230V
115/230V
-320K
PLT30-32
IRF 810
|
PDF
|