Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    FIRE RESISTANCE PERIOD Search Results

    FIRE RESISTANCE PERIOD Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    PS7804-1A-A Renesas Electronics Corporation Low On-state Resistance, , / Visit Renesas Electronics Corporation
    PS7804-1A-F3-A Renesas Electronics Corporation Low On-state Resistance, , / Visit Renesas Electronics Corporation
    PS710BL-1A-E3-A Renesas Electronics Corporation Low On-state Resistance, , / Visit Renesas Electronics Corporation
    PS710BL-1A-A Renesas Electronics Corporation Low On-state Resistance, , / Visit Renesas Electronics Corporation
    278-25-336SA2I8 Renesas Electronics Corporation Resistance Weld SMD Crystal Visit Renesas Electronics Corporation

    FIRE RESISTANCE PERIOD Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    BS4066

    Abstract: 3g230 tyco MOST FLT0111 Raychem MIL-W-16878 MIL-W-22759 pvc wires IEC332
    Text: FLT dual-wall wire combines flexibility with tough thin wall insulation to enable bundles to be routed through areas in which conventional wires cannot be used. • • • • • • Highly flame retarded/non melting Limited fire hazard 600V rated Excellent fluid resistance


    Original
    WC0027 BS4066 3g230 tyco MOST FLT0111 Raychem MIL-W-16878 MIL-W-22759 pvc wires IEC332 PDF

    60947-2 MAX EARTH LOOP IMPEDANCE

    Abstract: S2C-H10 ABB STOTZ - S 212 M 59371 s201h S2C-A1 stotz s 212 transistor r1009 IEC 60947-2 ABB S200M
    Text: Technical Data System pro M System pro M compact Miniature Circuit-Breakers for Railway Applications Railway application prEN 45545-1 Level HL4 220/440 V DC 230/400 V AC 60 V DC 230/400 V AC 1. Fire Resistance Miniature circuit-breakers of the S 200 P and S 280 UC series,


    Original
    F16-101/-102, 50155/EN D0201 60947-2 MAX EARTH LOOP IMPEDANCE S2C-H10 ABB STOTZ - S 212 M 59371 s201h S2C-A1 stotz s 212 transistor r1009 IEC 60947-2 ABB S200M PDF

    AMP 9-927742-2

    Abstract: 284985-1 5-1241967-8 Tab 6.3x0.8 293008 293009-1 293043-1 284986 7-927742-6 FTEC174
    Text: 501-20122 Qualification Test Report Rev. B1 2-12 Position, FASTIN-FASTON* TAB Housing, RAST 5 1. INTRODUCTION Purpose This document summarizes testing activity performed on the subject TE Product and establishes its resistance to heat and fire. Scope This report covers the performance to the Glow wire test of the subject product as per IEC 60695-2-11


    Original
    FTEC174 AMP 9-927742-2 284985-1 5-1241967-8 Tab 6.3x0.8 293008 293009-1 293043-1 284986 7-927742-6 PDF

    8-32VDC

    Abstract: burst fire controller scr phase angle controller P42010
    Text: series MCBC 25-90Amp - 120/480 Vac - AC OUTPUT > Burst Fire Controller / SSR in One Package > Low Voltage, Current, or Potentiometer Control > Output Status Indicator Load Open, No Voltage > 0-100% Control Range > 2 Time Base Periods Available > Separate Output Enable / Disable Control


    Original
    25-90Amp 50/60Hz, J2705 8-32VDC burst fire controller scr phase angle controller P42010 PDF

    Untitled

    Abstract: No abstract text available
    Text: series MCBC 25-90Amp - 120/480 Vac - AC OUTPUT > Burst Fire Controller / SSR in One Package > Low Voltage, Current, or Potentiometer Control > Output Status Indicator Load Open, No Voltage > 0-100% Control Range > 2 Time Base Periods Available > Separate Output Enable / Disable Control


    Original
    25-90Amp 50/60Hz, SJ/T11364 SJ/T11364 PDF

    burst fire controller

    Abstract: BH17
    Text: series MCBC 25-90Amp - 120/480 Vac - AC OUTPUT > Burst Fire Controller / SSR in One Package > Low Voltage, Current, or Potentiometer Control > Output Status Indicator Load Open, No Voltage > 0-100% Control Range > 2 Time Base Periods Available > Separate Output Enable / Disable Control


    Original
    25-90Amp 50/60Hz, SJ/T11364 SJ/T11364 burst fire controller BH17 PDF

    Untitled

    Abstract: No abstract text available
    Text: series MCBC 25-90Amp - 120/480 Vac - AC OUTPUT > Burst Fire Controller / SSR in One Package > Low Voltage, Current, or Potentiometer Control > Output Status Indicator Load Open, No Voltage > 0-100% Control Range > 2 Time Base Periods Available > Separate Output Enable / Disable Control


    Original
    25-90Amp 50/60Hz, SJ/T11364 SJ/T11364 PDF

    S82Y-bat01

    Abstract: LC-R123R4PG LCR122R2PG S82Y-BAT02 LC-R122R2 S82Y-TS01 S8T-DCBU-01 S8TS-06024 S82YTS01 LCR123R4PG
    Text: DC Backup Block for S8TS S8T-DCBU-01 CSM_S8T-DCBU-01_DS_E_4_1 DC Backup Block for S8TS Prevents 24-VDC Outages Due to Power Interruptions or Failures • Supplies 24 VDC for a fixed period of time even during AC input outages to considerably improve system reliability.


    Original
    S8T-DCBU-01 S8T-DCBU-01 24-VDC S82Y-bat01 LC-R123R4PG LCR122R2PG S82Y-BAT02 LC-R122R2 S82Y-TS01 S8TS-06024 S82YTS01 LCR123R4PG PDF

    block diagram for fire alarm system

    Abstract: automatic heat detector report AIR FLOW DETECTOR FULL REPORT BS5445 block fire alarm system block diagram AIR FLOW DETECTOR FULL REPORT using led fire alarm system block diagram fire alarm using thermistor BS6007 rate of rise heat detectors
    Text: Issued March 1994 C17171 Multizonefirealarmsystems There are two main reasons for installing fire alarm systems, the protection of life and the protection of property. Fire can kill or maim in many ways eg. by asphyxiation, irradiation, poisoning or burning and legislation has


    Original
    C17171 block diagram for fire alarm system automatic heat detector report AIR FLOW DETECTOR FULL REPORT BS5445 block fire alarm system block diagram AIR FLOW DETECTOR FULL REPORT using led fire alarm system block diagram fire alarm using thermistor BS6007 rate of rise heat detectors PDF

    magnetic reed switch

    Abstract: MK22 reed sensor pressure sensitive alarm fire sensor
    Text: Reed Sensors Monitor Pressure in Fire Extinguishers REED RELAYS REED SENSORS REED SWITCHES Introduction Fire extinguishers are usually under high pressure. When called upon in an emergency situation they must expel their contents rapidly and over as long a


    Original
    MK17-X-3 MK06-4 MK06- MK06MK06-5 MK06MK06-6 MK06MK06-7 magnetic reed switch MK22 reed sensor pressure sensitive alarm fire sensor PDF

    Untitled

    Abstract: No abstract text available
    Text: CTS Thick Film Surge Resistors Surges are described as large current or voltage peaks for short periods of time. Surge requirements are defined by the telecommunication industry and are intended to simulate either lightning strikes or power cross conditions on external


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: 1 Scope This specification applies to the lithium-ion rechargeable battery. 2 Based on written a: GB/T 18287—2000《General specifications of cellular phone lithium-ion battery》; b: GB/T 3873-1983《General technical specifications of communication equipment product


    Original
    GB6388â GB5296 --------------------------------SKT603450 ----------------------603450P 3000mAh PDF

    Untitled

    Abstract: No abstract text available
    Text: 1 Scope This specification applies to the lithium-ion rechargeable battery. 2 Based on written a: GB/T 18287—2000《General specifications of cellular phone lithium-ion battery》; b: GB/T 3873-1983《General technical specifications of communication equipment product


    Original
    GB6388â GB5296 -------------------------------SKT603450P ----------------------603450P 1000mAh PDF

    FIRE ALARM SYSTEMS: Fighting Fire with Technology

    Abstract: No abstract text available
    Text: Advertisement Fire Alarm Systems: Fighting Fire With Technology BY ALBEN ROL AND, MANAGER, PRODUCT ENGINEERING, CAROL BRAND ELECTRONIC PRODUCTS – GENERAL CABLE “Safety” is a buzzword that affects every aspect of our lives. From the seat belt you wear during your daily commute to the “caution”


    Original
    PDF

    fire suppression system

    Abstract: Sealed Thermostat fire resistance period
    Text: TRANSPORTATION APPLICATIONS Application Note 3000 Series Thermostats in Vehicle Fire Suppression Applications BACKGROUND A fire resulting from a vehicle collision may lead to death because it becomes impossible to escape the burning vehicle. An effective fire suppression system helps to reduce fatalities


    Original
    008096-1-EN fire suppression system Sealed Thermostat fire resistance period PDF

    trimmer 1k

    Abstract: PCB layout Potentiometers 1K TRIMMER PCB Potentiometers potentiometer 104 Potentiometer trimmer 103 TRIMMER 100k trimmer potentiometer bottom adjust Potentiometer trimmer 103 or 10k Potentiometer trimmer 104 or 10k
    Text: Economy Trimmers Type CT6 Series Type CT6 Series Characteristics Electrical Resistance Range: Resistance Values: Resistance Tolerance: End Resistance: Maximum Wiper Current: Power Rating: Limiting Element Voltage: 100R to 1M 1, 2, and 5 in each decade ± 30%


    Original
    PDF

    SEIKO MS621

    Abstract: RB414 ms614s XH414H IV01E SEIKO INSTRUMENTS ms920 XH414H MS920S FL27E MS621 battery ms920 xh414
    Text: Network Components Business Unit Micro Batteries Product Catalogue CMOS IC Quartz Crystals Micro Batteries Materials Liquid Crystal Display Custom LCD Module October 2002 Precautions for Your Safety SII Lithium-ion rechargeable batteries MS, RB, HB, TS contain flammable organic solvents. For your


    Original
    CAB0210EJ0055-10/C SEIKO MS621 RB414 ms614s XH414H IV01E SEIKO INSTRUMENTS ms920 XH414H MS920S FL27E MS621 battery ms920 xh414 PDF

    Untitled

    Abstract: No abstract text available
    Text: Philips Components Product specification Fusible chip resistor size 1206 FEATURES • Overload protection without the risk of fire • Grey coating for ease of recognition • Reduced size of final equipment FRC01 5% QUICK REFERENCE DATA DESCRIPTION Resistance range


    OCR Scan
    10-6/K FRC01 E24/E96 PDF

    Andrew Rxl5-1RNT

    Abstract: Andrew RADIAx Andrew Rxl4 RXL5 - 1RNT RXL4 - 1RNT RXL4 RXL4-2RNT Andrew RXL2-2RNT RXL6 LDF4RN-50A
    Text: HELIAX Coaxial Cables Fire Retardant Cables and Waveguides Fire R etardance Requirem ents Cable and waveguide installed inside a building usually must meet fire retardance requirements. In the United States, the National Electrical Code NEC ’ sets the standard for coaxial cable used within buildings and


    OCR Scan
    PDF

    Untitled

    Abstract: No abstract text available
    Text: SPECIF ICATI ON Li t h i u m B a t t e r y CR2 0 2 5 MATSUSHITA BATTERY INDUSTRIAL CO.,LTD. LITHIUM & MICRO BATTERY DIVISION I Lithium I Battery TT I O 1ST L i / M n 0 C R 2 0 2 5 % 1 Model 2 Nominal 3. Nominal Capacity : 1 6 5 mAh 4. Nominal 2. 5. Dimension


    OCR Scan
    PDF

    panasonic CR 2032

    Abstract: cr2 lithium
    Text: S P E C I F I CAT I 0 N L i t h i um Ba t t e r y CR2 0 3 2 MATSUSHITA BATTERY INDUSTRIAL CO.,LTD. LITHIUM & MICRO BATTERY DIVISION S P E C Lithium * 1. F' Battery f Model I * I O P CR 2 0 3 2 * Nominal Capacity 2 2 OmAh 4. Nominal 3. 5. Dimension 6. Terminal


    OCR Scan
    PDF

    Untitled

    Abstract: No abstract text available
    Text: CTS T F hick ilm S ii r i; mal imaging plots to optimize the design. Refer to the IT curve figure 2 for typical fuse operation characteristics. Surges are described as large current or voltage peaks for short periods of time. Surge requirements are defined


    OCR Scan
    PDF

    MH12210

    Abstract: panasonic date code for batteries
    Text: Control number N2009-1E-002 Established date : Feb,2,2009 PT. Panasonic Gobei Energy Indonesia Revision history No. Revision Date Established 1 Feb,2,2009 2 Production site change ; [New] PT. Panasonic Gobel Energy Indonesia Indonesia [Previous] Pansonic Corporation Energy Company (Japan)


    OCR Scan
    N2009-1E-002 CR1220 2-10N 1000gf) MH12210 panasonic date code for batteries PDF

    MH12210

    Abstract: mh12210 Lithium Battery panasonic mh12210 panasonic battery br date code panasonic date code for batteries 4263B
    Text: 2006- 2E-003 D IG I—KEY CORPORATION SPECIFICATION LITHIUM Ordering Code : Model Code BATTERY BR-1/2AAE5P BR-1/2AA Approved by Division/Department Name Title Signature/date Issued : Feb,7th,2006 Lithium and Micro Battery Business Unit Primary Battery Company


    OCR Scan
    2E-003 MH12210 mh12210 Lithium Battery panasonic mh12210 panasonic battery br date code panasonic date code for batteries 4263B PDF