Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    EN60947 Search Results

    SF Impression Pixel

    EN60947 Price and Stock

    BUCH EN60947-7-1

    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Quest Components EN60947-7-1 8
    • 1 $2.744
    • 10 $2.058
    • 100 $2.058
    • 1000 $2.058
    • 10000 $2.058
    Buy Now

    EN60947 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    A16ZA-3003

    Abstract: A165E A165E-LS-24D-01 A165E-LS-24D-02 A165E-S-01 EN418 EN60947-5-1
    Text: Emergency Stop Switch A165E Mounting Aperture of 16 mm • Modular construction, easy installation • Direct opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-51, Æ . only for NC contacts • Conforms to EN418, EN60947-5-1.


    Original
    PDF A165E EN60947-51, EN418, EN60947-5-1. A165E D-213 A16Z-5070 A16Z-3004 D-214 A16ZA-3003 A165E-LS-24D-01 A165E-LS-24D-02 A165E-S-01 EN418 EN60947-5-1

    5011b

    Abstract: 5101W OMRON G22 EN60947-5-1 IEC947-5-1 A16-1NRN push button 3way omron g8
    Text: Pushbutton Switch A16 Mounting Aperture of 16 mm • Modular construction Pushbutton + Case + Lamp + Switch • Wide Variety of Control and Signal Devices: Lighted, Non-Lighted, and Buzzer • UL and cUL approved. • Conforms to EN60947-5-1, IEC947-5-1


    Original
    PDF EN60947-5-1, IEC947-5-1 A124-E1-02 5011b 5101W OMRON G22 EN60947-5-1 IEC947-5-1 A16-1NRN push button 3way omron g8

    A16S-2N

    Abstract: EN60947-5-1 IEC947-5-1 A16S-2N2L
    Text: Knob-type Selector Switch A165S / W Mounting Aperture of 16 mm Modular construction Oil-resistant IP65 models UL and CSA approved, VDE pending Conforms to EN60947-5-1, IEC947-5-1 Short mounting depth, less than 28.5 mm below panel Wide range of switching capacity from general to


    Original
    PDF A165S EN60947-5-1, IEC947-5-1 A16S-2N EN60947-5-1 IEC947-5-1 A16S-2N2L

    EN60947-5-1

    Abstract: IEC947-5-1 A16S A165W-A2A C4520 A1657
    Text: Knob-type Selector Switch A165S / W Mounting Aperture of 16 mm Modular construction Oil-resistant IP65 models UL and CSA approved, VDE pending Conforms to EN60947-5-1, IEC947-5-1 Short mounting depth, less than 28.5 mm below panel Wide range of switching capacity from general to


    Original
    PDF A165S EN60947-5-1, IEC947-5-1 A107-E1-1 EN60947-5-1 IEC947-5-1 A16S A165W-A2A C4520 A1657

    EN574

    Abstract: 60-2439 800Z-G3AG1 5V RELAY MSR125H 800Z-GL2Q5 800z-gf3065 800Z-GL2065B 800Z-G2AH1 800Z-GL3065
    Text: Two-Hand Control Devices Zero-Force Touch Buttons 800Z General Purpose Specifications Standards EN574, EN954-1, IEC/EN60947-5-1, IEC/EN60204-1 cULus, C-Tick, and CE marked for all applicable directives Approvals Power Supply Description The general purpose Bulletin 800Z Zero-Force Touch Buttons are


    Original
    PDF EN574, EN954-1, IEC/EN60947-5-1, IEC/EN60204-1 150mA EN574 60-2439 800Z-G3AG1 5V RELAY MSR125H 800Z-GL2Q5 800z-gf3065 800Z-GL2065B 800Z-G2AH1 800Z-GL3065

    440N-Z2NRS1A

    Abstract: 440N-Z2NRS1C 440NZ2NRS1B 440N-Z21W1PH 440N-Z21W1PA 440N-Z21W1PB 440R-W23219 440R-N23132 440r-h23176 MSR127TP
    Text: Safety Switches Non-Contact Switches Magnetically Coded Specifications MC1 MC2 Safety Ratings EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC609475-1, IEC/EN60947-5-3, ANSI B11.19, AS4024.1 Safety Classification Cat. 1 device per EN 954-1 dual channel


    Original
    PDF EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC609475-1, IEC/EN60947-5-3, AS4024 889D-F4ACDM- 440N-Z2NRS1A 440N-Z2NRS1C 440NZ2NRS1B 440N-Z21W1PH 440N-Z21W1PA 440N-Z21W1PB 440R-W23219 440R-N23132 440r-h23176 MSR127TP

    SR223SMT

    Abstract: TL4019-31102TM TL4019-50241F2M TL4019-30241F1M EN1088 EN292 EN60204-1 EN60947-5-1 G182 G184
    Text: TL4019 R C US Conforms to EN1088, EN60947-5-1, EN292, EN60204-1 UL and C-UL listed, BG approved safety interlock switches G TL4019 Safety Interlock Switch with Guard Door Locking • ■ ■ ■ High locking force of 1200 N 270 lb. locks guard door shut


    Original
    PDF TL4019 EN1088, EN60947-5-1, EN292, EN60204-1 TL4019 res1103SKM 90-degree SR223SMT TL4019-31102TM TL4019-50241F2M TL4019-30241F1M EN1088 EN292 EN60204-1 EN60947-5-1 G182 G184

    THERMAL Fuse m20

    Abstract: T4012 1575R omron T4012 EN1088 EN292 EN60204-1 EN60947-5-1 G158 G160
    Text: T4012 Rev. 12.07 R C US Conforms to EN1088, EN292, EN60947-5-1, EN60204-1 UL and C-UL listed, BG approved safety interlock switches G T4012 Universal Tongue-Operated Safety Interlock Switch • Strong and versatile—the compact size of the strong, glass-filled thermoplastic housing allows this switch to be used


    Original
    PDF T4012 EN1088, EN292, EN60947-5-1, EN60204-1 THERMAL Fuse m20 T4012 1575R omron T4012 EN1088 EN292 EN60204-1 EN60947-5-1 G158 G160

    Untitled

    Abstract: No abstract text available
    Text: Back Knob-type Selector Switch A165S / W Mounting Aperture of 16 mm Modular construction Oil-resistant IP65 models UL and CSA approved, VDE pending Conforms to EN60947-5-1, IEC947-5-1 Short mounting depth, less than 28.5 mm below panel Wide range of switching capacity from general to


    Original
    PDF EN60947-5-1, IEC947-5-1 A165S

    3AMC

    Abstract: pushbutton square dpdt
    Text: Key-type Selector Switch A165K Mounting Aperture of 16 mm • Modular construction • Oil-resistant IP65 models • UL and cUL approved. • Conforms to EN60947-5-1, IEC947-5-1 • Short mounting depth, less than 28.5 mm below panel • Wide range of switching capacity from standard to microload


    Original
    PDF A165K EN60947-5-1, IEC947-5-1 24-mm A126-E1-02 3AMC pushbutton square dpdt

    K2-12A01

    Abstract: k2885 K2-09A10 K2-23A10 contactor coils 415v k2-09a10 U840 diode K2-09A01 K2-12A10 K3-175A11 K3-450A22
    Text: • Up to 700A AC3 ■ Up to 1000A AC1 ■ DIN rail mounting to 30 amps ■ Add-on auxiliary contacts ■ International approvals ■ Designed to EN60947-1 M New od els Contactors and Overloads Options and ordering codes K2 Contactor series – 09 A COIL VOLTAGE


    Original
    PDF EN60947-1 50/60Hz 20-240V 80-415V K2-09 K2-60 K2-45 K3-150 K2-12A01 k2885 K2-09A10 K2-23A10 contactor coils 415v k2-09a10 U840 diode K2-09A01 K2-12A10 K3-175A11 K3-450A22

    24VAC LED Lamp

    Abstract: 220 110 transformer A22Z-B101Y A22L-01M a22e A22-tn A22-12 A22E-MP A22Z-3500-1 jis C5003
    Text: A22-E Emergency Stop Switch For Panel Cutout of 22 or 25 mm dia. H Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1, → for NC contacts H Safety lock mechanism prevents misuse No tampering, in accordance with


    Original
    PDF A22-E EN60947-5-1, A22Z-3466-1 A22-E-j-j A22Z-B101Y BA9S/13j 24VAC LED Lamp 220 110 transformer A22Z-B101Y A22L-01M a22e A22-tn A22-12 A22E-MP A22Z-3500-1 jis C5003

    A22E

    Abstract: g307 G306 EN60947-5-1 A22Z-B10
    Text: Emergency Stop Switch A22E Install in 22-dia. or 25-dia. Panel Cutout • Direct opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1, Æ . only for NC contacts • Safety lock mechanism prevents misuse. (No tampering – in accordance with EN 418)


    Original
    PDF 22-dia. 25-dia. EN60947-5-1, A22Z-3466-1 A22Z-B101Y G-303 G-319 A119-E2-03A-X G-320 A22E g307 G306 EN60947-5-1 A22Z-B10

    GuardMaster TLS2 gd2

    Abstract: 440G-T27256 440G-T27127 440G-T27121 440G-T27252 440G-T27260 440G-T27255 440G-T27175 440G-T27235 TLS-GD2
    Text: Interlock Switches Guard Locking Switches TLS-GD2 Specifications Shown with optional Key Release Kit Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 1 Device per EN954-1 Dual channel interlocks suitable for


    Original
    PDF EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, EN60947-5-1, AS4024 EN954-1 GuardMaster TLS2 gd2 440G-T27256 440G-T27127 440G-T27121 440G-T27252 440G-T27260 440G-T27255 440G-T27175 440G-T27235 TLS-GD2

    Untitled

    Abstract: No abstract text available
    Text: R Emergency Stop Switch A22E Install in 22-dia. or 25-dia. Panel Cutout H Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1, → H Safety Lock Mechanism prevents misuse. No tamper – in accordance with EN418


    Original
    PDF 22-dia. 25-dia. EN60947-5-1, EN418) UL508, E41515 EN60947-5-1 30ing 1-800-55-OMRON

    jis C5003

    Abstract: A165E A165E-LM-24D-01 A165E-LS-24D-01 A165E-LS-24D-02 A165E-S-01 A165E-S-02 A165E-S-03U EN418 EN60947-5-1
    Text: Emergency Stop Switch A165E Mounting Aperture of 16 mm Modular construction, easy installation Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1, → . only for NC contacts Conforms to EN418, EN60947-5-1. Includes a safety lock to prevent misuse.


    Original
    PDF A165E EN60947-5-1, EN418, EN60947-5-1. A165E A120-E1-2 jis C5003 A165E-LM-24D-01 A165E-LS-24D-01 A165E-LS-24D-02 A165E-S-01 A165E-S-02 A165E-S-03U EN418 EN60947-5-1

    Untitled

    Abstract: No abstract text available
    Text: Email: info@grupopremo.com Web: http://www.grupopremo.com • • • • • • • Open loop Hall Effect sensor. Unipolar power supply. High currents measurement. High precision. High linearity. Isolated plastic case recognized according to UL94-V0. EN60947:2004, IEC60950-1:2001, EN50178:1998 compliant.


    Original
    PDF UL94-V0. EN60947 IEC60950-1 EN50178 HCT-50BSR5 HCT-100BSR5 HCT-200BSR5 HCT-300BSR5 HCT-400BSR5 HCT-500BSR5

    Untitled

    Abstract: No abstract text available
    Text: Email: info@grupopremo.com Web: http://www.grupopremo.com • • • • • Open loop Hall Effect sensor. Bipolar power supply. Low power consumption. Isolated plastic case recognized according to UL94-V0. EN60947-1:2004, IEC60950-1:2001, EN50178:1998 compliant.


    Original
    PDF UL94-V0. EN60947-1 IEC60950-1 EN50178 HCT-050BS HCT-100BS HCT-200BS HCT-300BS HCT-400BS HCT-500BS

    Untitled

    Abstract: No abstract text available
    Text: Emergency Stop Pushbutton with Black/Yellow Box 72x72x58mm • • • • • • • • • Double insulation Degree of protection IP65 PG 13.5 / M20cable gland 4 Unloseable screws According to EN418 Conform to IEC947-5-1, EN60947-5-1 Press to lock, twist clockwise to release


    Original
    PDF 72x72x58mm M20cable EN418 IEC947-5-1, EN60947-5-1 EMPB020/2BY 250VAC Q600/Q300)

    FZ 5.1

    Abstract: limit switch cam type limit switch VDE 0660 BS 54 19 VDE 0660 VDE 0660 AC11 VDE 0660 LIMIT SWITCH FM515 VDE 0660 EN60947-5-1
    Text: Compact Heavy Duty Limit Switches FM/FR/FZ/FX Compact limit switches with snap-action contacts and positive break according to BS/EN60947-5-1 ❚ Bifurcated contacts for low resistance and high reliability – suitable for switching low-level electronic currents


    Original
    PDF BS/EN60947-5-1 500VAC/600VDC EN50047 300mm 250VAC/300VDC VFPG13 9-12mm FR/FM/FX/FZ/03/03 FZ 5.1 limit switch cam type limit switch VDE 0660 BS 54 19 VDE 0660 VDE 0660 AC11 VDE 0660 LIMIT SWITCH FM515 VDE 0660 EN60947-5-1

    Z1531-ND

    Abstract: Z1508-ND Z1506 Z1507-ND Z1530-ND Z1575-ND Z1560-ND Z166
    Text: A22 Series Switches Cont. Emergency Stop Pushbutton Switches Omron Emergency stop switches feature a positive opening mechanism with minimal contact separation of 3mm in accordance with EN60947-5-1. Safety lock mechanism prevents misuse or tampering. Innovative two-piece snap together construction reduces installation


    Original
    PDF EN60947-5-1. 110VAC 24VDC 60-dia. 40-dia. 40-d516-ND Z1517-ND Z1518-ND Z1519-ND Z1531-ND Z1508-ND Z1506 Z1507-ND Z1530-ND Z1575-ND Z1560-ND Z166

    Untitled

    Abstract: No abstract text available
    Text: Accessories WM3 The resistor module meets the requirements for line monitoring between a mechanical contact and a signal processor. The input circuit is designed for sensors according to EN60947-5-6 NAMUR and equipped with a wire-break and short-circuit monitoring function.


    Original
    PDF EN60947-5-6 MS15-231Ex0-R MS15-231Ex0-R EN60079-14, 2013-07-13T04 D-45472

    12SC1

    Abstract: T3008-02F2C5 44524-0010 EN1088 EN60204-1 EN60947-5-1 G145 G146 T3008-02F1C1 T3008-02SC5
    Text: T3008 R C US Conforms to EN1088, EN60947-5-1, EN60204-1 UL and C-UL listed, BG approved • Applications Typical applications are on sliding guard doors or swinging guard doors with a 6 in. minimum swing radius. safety interlock switches G T3008 Miniature Tongue-Operated Safety Interlock Switch


    Original
    PDF T3008 EN1088, EN60947-5-1, EN60204-1 T3008 T3008-03F1C5 T3008-11F2C1 T3008-11F2C5 12SC1 T3008-02F2C5 44524-0010 EN1088 EN60204-1 EN60947-5-1 G145 G146 T3008-02F1C1 T3008-02SC5

    IEC 947 EN60947

    Abstract: D4BS-15FS EN60947-5-1 IEC529 IEC536 IEC68-2-27 IEC947-5-1 OMRON m5-1 IEC947 en60947 Switches
    Text: * M omRon D4BS Safety Interlock Switch Safety Interlock Switch Used for Door Guard Individual operation key and switch operation prevents false operation conforms to BS EN60947-5-1 . Operation key positively forces the switch contacts upon withdrawal. Mounting pitch and shape conform to EN50041.


    OCR Scan
    PDF EN60947-5-1) EN50041. D4BS-15FS 1/2-14NPT. IEC 947 EN60947 D4BS-15FS EN60947-5-1 IEC529 IEC536 IEC68-2-27 IEC947-5-1 OMRON m5-1 IEC947 en60947 Switches