Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    EN60688 Search Results

    EN60688 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    energy

    Abstract: AD2020 Wiring Diagram Kwh meter digital CAN3-C17-M84 AR1034 EN-62053-22 2kV relay EN62053-22 Asy transistor EN6205
    Text: Energy Management Modular Smart Power Quality Transducer Type PQT-H • Up to 12 optional digital inputs sync function, remote digital input control • Up to 16 optional digital outputs (pulse, alarm, remote control) • 16 freely configurable alarms with OR/AND logic linkable with up to 4 relay outputs and up to 16 open collector outputs


    Original
    PDF 10VDC, 18-60VAC/VDC, e171006 WM5-96 AO2050 AO2051 20mADC) 10VDC) AO2052 AO1058 energy AD2020 Wiring Diagram Kwh meter digital CAN3-C17-M84 AR1034 EN-62053-22 2kV relay EN62053-22 Asy transistor EN6205

    RJ12 to RS232

    Abstract: RJ12 to RS485 IEC-60688 Wiring Diagram rj12 CPT-DIN RJ12 female connector RJ12 connector rj12 rs485 CPT-DIN Basic Version RJ12
    Text: Energy Management Compact Power Transducer Type CPT-DIN “Basic version” • RS232 serial port on request • Alarms only from serial communication port VLN, An • Class 2 (active energy) • Class 3 (reactive energy) • Accuracy ±0.5 F.S. (current/voltage)


    Original
    PDF RS232 260VAC/DC 60VAC/DC 45x83 RS422/485 CPT-DINBDS190606 RJ12 to RS232 RJ12 to RS485 IEC-60688 Wiring Diagram rj12 CPT-DIN RJ12 female connector RJ12 connector rj12 rs485 CPT-DIN Basic Version RJ12

    din 43864 rs232 kwh

    Abstract: AA1001 SPT-90 AV7100 AA1000 CT 3-12 overload relay 20va transformer SPT-90AV51HXA1 DIN43864
    Text: Energy Management Modular Smart Power Transducer Type SPT-90 • Class 0.5 current/voltage • 16-bit µP-based modular smart power transducer • Measurements of: W, Wavg, VA, VAr, PF, Wh, VAh, VArh, Amax (among the phases), VL-L avg, VL1-N, VL2-N, VL3-N, Hz L1.


    Original
    PDF SPT-90 16-bit 20mADC mADC/10 RS232 transduc51 AO1052 AO1053 AO1054 din 43864 rs232 kwh AA1001 SPT-90 AV7100 AA1000 CT 3-12 overload relay 20va transformer SPT-90AV51HXA1 DIN43864

    pt100 temperature sensor circuit diagram

    Abstract: adjustable zero span circuit pt100 amplifier circuit diagram PT100 Amplifier pt100 circuit diagram Pt100 3 wire transformer from 230V AC to 28v PT100 IEC 751 PT100 SENSOR pt100 sensor amplification for voltage
    Text: + - B1 B2 B3 TEMPERATURE TRANSMITTER + TEMPERATURE TRANSMITTER 25 50 75 75,0 mm - B1 B2 B3 LIMIT 100 DIFF. Z E R O O N S P A N A1 A2 Z E R O Type: TAMA & TAMB S P A N 12 11 14 35,0 mm PT100 TEMPERATURE TRANSMITTER A1 A2 45,0 mm 100,0 mm FEATURES: Description:


    Original
    PDF PT100 EN50081 EN50082 EN60255 EN60688 pt100 temperature sensor circuit diagram adjustable zero span circuit pt100 amplifier circuit diagram PT100 Amplifier pt100 circuit diagram Pt100 3 wire transformer from 230V AC to 28v PT100 IEC 751 PT100 SENSOR pt100 sensor amplification for voltage

    Untitled

    Abstract: No abstract text available
    Text: Energy M a na gement Compa ct Pow er Tra nsducer Type CPT-DIN “ Ba sic version” • RS232 serial port on request • Alarms only from serial communication port VLN, An • Class 2 (active energy) • Class 3 (reactive energy) • Accuracy ±0.5 F.S. (current/voltage)


    Original
    PDF RS232 260VAC/DC 60VAC/DC CPT-DINBDS080610

    tyn 277

    Abstract: 256-TFAU 256-TWM paladin 253-TAL 256-TWL 256-TWH AS1384 253-THZ 256-TYN 253-TAL
    Text: Paladin Transducers 250 Series Class 0.5 An extensive range of Class 0.5 transducers providing measurement, isolation and conversion of electrical parameters into industry standard DC output signals. The range offers protection against high voltage and overload, and resistance


    Original
    PDF 256-TFSU 256-TFCU 256-TFAU 256-TFTU 256-TFEU 256-TFBU 256-TPDU tyn 277 256-TFAU 256-TWM paladin 253-TAL 256-TWL 256-TWH AS1384 253-THZ 256-TYN 253-TAL

    CPT-DIN

    Abstract: No abstract text available
    Text: Energy M a na gement Compa ct Pow er Tra nsducer Type CPT-DIN “ Adva nced version” • One digital output and RS485 communication port 2 wires only • 16 freely configurable alarms with OR/AND logic linkable to up to 2 digital outputs • RS422/485/RS232 communication port (MODBUSRTU), iFIX SCADA compatibility


    Original
    PDF RS485 RS422/485/RS232 CPT-DIN

    RJ12 to RS232

    Abstract: Wiring Diagram rj12 EN62053-31 EN62053-21 Dupline RJ12 to RS485 CPT-DIN Advanced Version RJ12 connector CPT-DIN RJ12 female connector
    Text: Energy Management Compact Power Transducer Type CPT-DIN “Advanced version” • One digital output and RS485 communication port 2 wires only • 16 freely configurable alarms with OR/AND logic linkable to up to 2 digital outputs • RS422/485/RS232 communication port (MODBUSRTU), iFIX SCADA compatibility


    Original
    PDF RS485 RS422/485/RS232 partial06 CPT-DINADS110706 RJ12 to RS232 Wiring Diagram rj12 EN62053-31 EN62053-21 Dupline RJ12 to RS485 CPT-DIN Advanced Version RJ12 connector CPT-DIN RJ12 female connector

    kwh meter analogue ct type DIAGRAM

    Abstract: Wiring Diagram Kwh meter digital CAN3-C17-M84 EN62053-22 IEC-60688 Led digital panel meters common ground info EN62053-21 WM5-96 c12.20 ansi EN6205
    Text: Energy Management Modular Smart Power Quality Analyzer Type WM5-96 • MODBUS RTU and TCP, JBUS protocol, iFIX SCADA compatibility • Real time clock function without back-up • Up to 12 optional digital inputs (sync function, remote digital input control)


    Original
    PDF WM5-96 10VDC, 18-60VAC/VDC, NEMA12 128x64 WM5-96DS171006 AO2050 AO2051 20mADC) kwh meter analogue ct type DIAGRAM Wiring Diagram Kwh meter digital CAN3-C17-M84 EN62053-22 IEC-60688 Led digital panel meters common ground info EN62053-21 WM5-96 c12.20 ansi EN6205

    Untitled

    Abstract: No abstract text available
    Text: Energy M a na gement M odular Smart Pow er Quality Analyzer Type W M 5 -9 6 • MODBUS RTU and TCP, JBUS protocol, iFIX SCADA compatibility • Real time clock function without back-up • Up to 12 optional digital inputs (sync function, remote digital input control)


    Original
    PDF 10VDC, 18-60VAC/VDC, NEMA12 128x64 WM5-96 AO2050 AO2051 20mADC) 10VDC) AO2052

    AO1036

    Abstract: AQ1042
    Text: Energy M a na gement M odular Smart Pow er Quality Transducer Type PQT-H • Up to 12 optional digital inputs sync function, remote digital input control • Up to 16 optional digital outputs (pulse, alarm, remote control) • 16 freely configurable alarms with OR/AND logic linkable with up to 4 relay outputs and up to 16 open collector outputs


    Original
    PDF 10VDC, 18-60VAC/VDC, dmd/S171006 WM5-96 AO2050 AO2051 20mADC) 10VDC) AO2052 AO1058 AO1036 AQ1042