E69905
Abstract: No abstract text available
Text: 4 RELEASED FOR PUBLICATION THIS DRAWING IS UNPUBLISHED. C COPYRIGHT 20 2 3 BY TYCO ELECTRONICS CORPORATION. 1 20 LOC - ALL RIGHTS RESERVED. REVISIONS DIST - P LTR B C DESCRIPTION DATE DWN APVD REVISED ECO-10-006100 22MAR2010 SW MS REVISED ECO-13-007617 06MAY2013
|
Original
|
ECO-10-006100
ECO-13-007617
22MAR2010
06MAY2013
E69905)
3/8-24UNF-2B
05NOV2008
E69905
|
PDF
|
Untitled
Abstract: No abstract text available
Text: SOLARLOK Connectivity Systems for PV Solutions Building a greener tomorrow As solar becomes an increasingly viable and competitive source of alternative energy, TE Solar works with you every step of the way to solve your connectivity challenges. Our proven expertise,
|
Original
|
|
PDF
|
UL 486A torque value data
Abstract: UL 486A pull test E317230 ul 1741 UL 486A pull test table 27 T212M-PRINTER E23401-000 UL 486A pull out test T212M-PRINTER Solar PV connector Terminal crimping training
Text: SOLARLOK Connectivity Systems for PV Installers Building a greener tomorrow TE Connectivity is committed to bringing the promise of renewable energy to the world. The SOLARLOK product offering provides a simple and reliable interconnection of solar systems.
|
Original
|
|
PDF
|
6063-T3
Abstract: hex bolt E69905
Text: Application Specification 114- 13242 Solid Wire Grounding Assembly NOTE i 24 MAR 10 Rev B All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
|
Original
|
|
PDF
|
E69905
Abstract: No abstract text available
Text: Application Specification SolKlip* Grounding Clip Assembly NOTE i 114- 13203 13 AUG 09 Rev D All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
|
Original
|
self--captivati14-
E69905
|
PDF
|
UL858
Abstract: 408-9640 LR7189 41M-19 crimped terminal 3545001 UL-467
Text: Application Specification 114-13095 Grounding Clip Terminals with F" Crimp Feature NOTE i 18 JUN 09 Rev C All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
|
PDF
|
UL 486A pull test
Abstract: UL 486A torque value data electronic passive components catalog UL 486A pull test table 27 E317230 ul 1741 solar pv inverter ul 1741 abb solar cable tyco AWG14-12
Text: SOLARLOK Connectivity Systems for PV Installers Building a greener tomorrow Tyco Electronics is committed to bringing the promise of renewable energy to the world. The SOLARLOK product offering provides a simple and reliable interconnection of solar systems.
|
Original
|
|
PDF
|
UL 486A pull test
Abstract: electronic passive components catalog UL 486A pull test table 27 11740657-2 UL 486A pull out test 6-1394461-2 connector E317230 edge connector 14 pin UL 486A torque value data 216134
Text: SOLARLOK Connectivity Systems for PV Manufacturers Building a greener tomorrow TE Connectivity is committed to bringing the promise of renewable energy to the world. The SOLARLOK product offering provides a simple and reliable interconnection of solar systems.
|
Original
|
|
PDF
|
E69905
Abstract: Esna catalog 80408-7
Text: Catalog 296973 JU M P Products for Power Utility Applications Issued 12/96 SHEAR-LOK Copper Tap I Grounding Connector No Special Tooling Required Product Facts Need more information? • Wedge Pressure Technology Write or call: ■ Shear-head bolt - controlled
|
OCR Scan
|
E69905
Esna catalog
80408-7
|
PDF
|
3-275187-3
Abstract: No abstract text available
Text: Catalog 889140 Premises Power and Electrical Building Products Grounding 2 AMPACT Copper Grounding System Proven, reliable, grounding connectors installed safely and simply in all weather conditions. Issued 5-97 AMPACT Copper Tap system makes use of Wedge Pressure Technology to
|
OCR Scan
|
18x6x7
460x150x180]
3-275187-3
|
PDF
|
str w 6553 a
Abstract: str W 6553 STR 6553 STR+6553 str 450
Text: Premises Power and Electrical Building Products Issued 5-97 2 A grid grounding system must dissipate surges of fault current quickly and effectively to limit the potential damage to equipment and to protect personnel close to the equipment. AMP WRENCH-LOK Grounding
|
OCR Scan
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Catalog 889140 Premises Power and Electrical Building Products Grounding 2 Issued 5-97 SHEAR-LOK Copper Tap/Grounding Connector No Special Tooling Required Product Facts • Wedge Pressure Technology ■ Shear-head bolt— controlled torque ■ Removable without conductor
|
OCR Scan
|
LR7189A-399
grou80408-3
E69905
|
PDF
|