    AWM2100VH Price and Stock

    Honeywell Sensing and Control AWM2100VH

    SENSOR UNAMP 200 SCCM
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey AWM2100VH Bulk 50
    • 1 -
    • 10 -
    • 100 $97.1384
    • 1000 $97.1384
    • 10000 $97.1384
    Buy Now
    Verical AWM2100VH 16 1
    • 1 $72.06
    • 10 $72.06
    • 100 $72.06
    • 1000 $72.06
    • 10000 $72.06
    Buy Now
    Arrow Electronics AWM2100VH 16 16 Weeks 1
    • 1 $72.06
    • 10 $72.06
    • 100 $72.06
    • 1000 $72.06
    • 10000 $72.06
    Buy Now
    Quest Components AWM2100VH 8
    • 1 $131.1552
    • 10 $111.4819
    • 100 $111.4819
    • 1000 $111.4819
    • 10000 $111.4819
    Buy Now
    Chip1Stop AWM2100VH 16
    • 1 $76.6
    • 10 $76.6
    • 100 $76.6
    • 1000 $76.6
    • 10000 $76.6
    Buy Now

    Honeywell Sensing and Control / MICRO SWITCH AWM2100VH

    Flow Sensors AIRFLOW/NEW PRESSURE PRESSURE
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Sager AWM2100VH
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Buy Now

    AWM2100VH Datasheets (2)

    Part ECAD Model Manufacturer Description Curated Datasheet Type PDF
    AWM2100VH Honeywell Airflow Sensor, Signal Conditioning: Unamplified (mV); Flow/Pressure Range: ±200 sccm; Port Style: Straight Original PDF
    AWM2100VH Honeywell Airflow Sensor, Signal Conditioning: Unamplified (mV); Flow/Pressure Range: ±200 sccm; Port Style: Straight Scan PDF

    AWM2100VH Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    hydrogen gas sensor

    Abstract: nitric oxide gas sensor GAS SENSOR for oxygen AWM1000 helium sensor AWM40000 AWM42150VH AWM5000 AWM2100VH oxygen gas sensor
    Text: REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Media Compatibility – Note #4 The microbridge mass airflow sensor incorporates a limited number of wetted materials in the construction of the device. The wetted materials in the sensor are fairly non-reactive and are compatible


    Original
    PDF AWM2100VH, AWM2300VH, AWM42150VH. hydrogen gas sensor nitric oxide gas sensor GAS SENSOR for oxygen AWM1000 helium sensor AWM40000 AWM42150VH AWM5000 AWM2100VH oxygen gas sensor

    "Flow Sensor"

    Abstract: helium sensor AWM2100V AWM2200V AWM2000 6 pin gas sensor AWM2150V AWM2300V AWM2300VH AWM2100VH
    Text: AWM2000 Series Mass flow sensor for gases FEATURES • Ranges 0.±30 to 0.±1000 sccm1 or 0.±4 "H2O 0.±10 mbar · Bidirectional sensing · Actual mass flow sensing · Low differential pressure sensing SERVICE To be used with dry gases only The AWM series is NOT designed for liquid


    Original
    PDF AWM2000 gas11 AWM2150V AWM2100V AWM2100VH AWM2300V AWM2300VH AWM2200V "Flow Sensor" helium sensor AWM2100V AWM2200V 6 pin gas sensor AWM2150V AWM2300V AWM2300VH AWM2100VH

    helium sensor

    Abstract: AWM42150VH nitrogen gas sensor hydrogen and carbon monoxide gas sensor nitric oxide gas sensor gas sensor helium types methane gas sensor gas sensor no2 Transistor A131 helium gas sensor
    Text: REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Correction Factors – Note #3 Microbridge mass airflow sensors operate by measuring the rate of relative heat transfer from a heater resistor to a temperature sensing resistor located on either side of the heater. The


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Correction Factors - Note # 3 Microbridge mass airflow sensors operate by measuring the rate of relative heat transfer from a heater resistor to a temper­ ature sensing resistor located on either side of the heater. The


    OCR Scan
    PDF

    CM200

    Abstract: No abstract text available
    Text: SPECIFICATIONS: RECOMMENDED EXCITATION USING TEST CIRCUIT 8VDC MIN POWER CONSUMPTION OUTPUT V O LTA G E TRIM POINT NULL VO LTA G E NULL V O LTA G E SHIFT (—2 5 ° C TO + 8 5 ° C ) OUTPUT V O LTA G E SHIFT ( + 2 5 ° C TO —2 5 °C ) ( + 2 5 ° C TO + 8 5 ° C )


    OCR Scan
    PDF 01VDC AWM2100VH CM200