Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    UL508 Search Results

    SF Impression Pixel

    UL508 Price and Stock

    Festo ADVUL-50-80-P-A

    COMPACT CYLINDER
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey ADVUL-50-80-P-A Bulk 1
    • 1 $691.57
    • 10 $691.57
    • 100 $691.57
    • 1000 $691.57
    • 10000 $691.57
    Buy Now

    Sprecher + Schuh ADD-UL508A-LABEL

    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Onlinecomponents.com ADD-UL508A-LABEL
    • 1 $94.68
    • 10 $53.34
    • 100 $47.94
    • 1000 $47.94
    • 10000 $47.94
    Buy Now

    Littelfuse Inc 3PH12P18MM

    Fuse Holder Accessories BUSBAR 3 PHASE 12 POLE 18MM
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 3PH12P18MM Box 1
    • 1 $35.56
    • 10 $35.56
    • 100 $33.82
    • 1000 $33.82
    • 10000 $33.82
    Buy Now

    Littelfuse Inc 3PH12P25MM

    Fuse Holder Accessories BUSBAR 3 PHASE 12 POLE 25MM
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 3PH12P25MM Box 10
    • 1 -
    • 10 $28.27
    • 100 $28.27
    • 1000 $28.27
    • 10000 $28.27
    Buy Now

    Littelfuse Inc 3PH9P18MM

    Fuse Holder Accessories BUSBAR 3 PHASE 9 POLE 18MM
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 3PH9P18MM Box 10
    • 1 -
    • 10 $25.1
    • 100 $25.1
    • 1000 $25.1
    • 10000 $25.1
    Buy Now

    UL508 Datasheets (1)

    Part ECAD Model Manufacturer Description Curated Type PDF
    UL508 Altech CIRCUIT BREAKER THERMAL MAGNETIC 1POLE 16A 277V Original PDF

    UL508 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    DLP180

    Abstract: DLP75241 24VDC/10A
    Text: DLP Series 75 to 240W, 24V Output DIN Rail Mount Power Supplies ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ Low Cost 3 Year Warranty UL508 Listed, NEC NFPA70 Class 2 1 (/C2 Models) Convection Cooled Conforms to EN61000-3-2 (PFC) Conducted and Radiated EMI, Class B Input Transient Protection, IEC61000-4


    Original
    PDF 0-600C) 100/230VAC 100/230VAC C/10A 100-240VAC 50/60Hz 170VAC DLP180 DLP75241 24VDC/10A

    HWS1000

    Abstract: HWS1000-48 HWS300-48 MC1230
    Text: HWS 300-1500 Single Output Industrial Power Supplies ‹ ‹ ‹ ‹ ‹ 5 Year Warranty UL508 approved SEMI F47 Compliant high line AC Universal Input (85 - 265VAC) High Efficiency Key Market Segments & Applications Factory Automation Test & Measurement Automated Service


    Original
    PDF UL508 265VAC) HWS300 HWS600 HWS1000 HWS1500 265VAC 370VDC 330VDC HWS1000) HWS1000-48 HWS300-48 MC1230

    LR38595

    Abstract: RS-433
    Text: GNR 45MM Series • Current ratings 35 and 45 amps • Output voltage 48-600 VAC • Direct Bond Copper DBC Substrate • LED input status indicator • 100K cycle UL508 Endurance Rating • UL / CSA / TUV Approved, CE Compliant • EMC Compliant Level 3


    Original
    PDF UL508 GNR35DHZ GNR35BHZ GNR35AHZ GNR45DHZ GNR45BHZ GNR45AHZ 47-63Hz) GNR35 GNR45 LR38595 RS-433

    Untitled

    Abstract: No abstract text available
    Text: Line Reactors RWK 212 Three-phase Line Reactor for Motor Drive Applications Provision of 4% impedance Reduction of mains harmonics Reduction of commutation notches Protection of motor drive electronics Approvals UL508C up to 400A. For use with AC or DC drives (power conversion equipment only


    Original
    PDF UL508C UL508C,

    2B50UM

    Abstract: 2b32 1B10UM
    Text: Application Examples: Business equipment, wiring protection, lighting, appliances, control circuits, some motors and some electronic applications. Relatively long thermal trip delay but low magnetic trip point. UL508 Listed One Pole Standard Pack: 12 Weight:


    Original
    PDF UL508 1B10UM 1B13UM 1B15UM 1B16UM 1B20UM 1B25UM 1B30UM 1B32UM 1B40UM 2B50UM 2b32 1B10UM

    Untitled

    Abstract: No abstract text available
    Text: DPP Series 15-100W, 5-48V Output DIN Rail Mount Power Supplies Features u Low Cost u Universal Input u NEC NFPA70 Class 2 2 u UL508 Listed u -10 to +71°C Operation Key Market Segments & Applications Specifications Model DPP15 DPP25/30 DPP50 DPP100 AC Input Voltage range


    Original
    PDF 5-100W, NFPA70 UL508 DPP15 DPP25/30 DPP50 DPP100 264VAC 132VAC 264VAC

    gn 84134020

    Abstract: 84134020 84134001 390Vrms
    Text: GN Series • Current ratings from 10 to 125 amps • Output voltage 24-280 and 48-660 VAC • Direct bond copper substrate • LED input status indicator • Available with IP20 “touch-safe” cover • Transient protection built-in • UL508 Endurance Rating 10-50A


    Original
    PDF UL508 0-50A) EN60950-1 47-440Hz) EN60950 E79183, LR38595 gn 84134020 84134020 84134001 390Vrms

    24V 20A SPST RELAY

    Abstract: wiring diagram 240v spst AT20 24V 30A SPDT RELAY RELAY PCB spst 12V 12V 30A PCB RELAY AC 220 to DC 12v 10A 30A SPDT 12V relay 240V 30A SPDT RELAY wiring diagram 30A SPDT power RELAY 240vac wiring diagram
    Text: TR91 n MAIN FEATURES Ÿ Up to 30A switching in SPST and 20A switching in SPDT arrangements. Ÿ Available as an open-frame relay, with a snap-on dust cover or with an immersion cleanable, plastic sealed case. Ÿ Meets UL508 and UL873 spacing requirements. Ÿ Available with UL class B & class Insulation materials.


    Original
    PDF UL508 UL873 110/120V 220/240V 33grs. E156521 LR700159 24V 20A SPST RELAY wiring diagram 240v spst AT20 24V 30A SPDT RELAY RELAY PCB spst 12V 12V 30A PCB RELAY AC 220 to DC 12v 10A 30A SPDT 12V relay 240V 30A SPDT RELAY wiring diagram 30A SPDT power RELAY 240vac wiring diagram

    crc type thermocouple

    Abstract: 409F sensor 40af 409AH B6000 ELC-TC04ANNN 5011633102-TE02 api 662 R type thermocouple
    Text: IL05003009E.pdf 2006-03-22 Storage: -25℃~70℃ temperature , 5~95% (humidity) 1.3 External wiring UL508 Note 1: Use only the wires that are supplied with your thermocouple sensor. ELC terminal screws should be tightened to 1.95 kg-cm (1.7 lb-in). Thermocouple


    Original
    PDF IL05003009E UL508 UL1604, 73/23/EEC 89/336/EEC 5011633102-TE02 ELC-TC04ANNN RS-485 crc type thermocouple 409F sensor 40af 409AH B6000 ELC-TC04ANNN 5011633102-TE02 api 662 R type thermocouple

    JTN1S-TMP-F-DC12V

    Abstract: JTN1S-TMP-F-DC24V schematic air conditioner
    Text: JT-N RELAYS COMPACT ECONOMICAL 30 AMP. RELAY FEATURES • High switching capacity — 30 A for 1 Form A • 2 contact arrangements — 1 Form A or 1 Form C • Sealed and “TMP” types available • UL/CSA recognized PCB & TMP type: UL508 group A spacing, UL873 spacing


    Original
    PDF UL508 UL873 JTN1aS-TMP-F-DC12V JTN1S-TMP-F-DC12V JTN1S-TMP-F-DC24V schematic air conditioner

    D-Trip

    Abstract: No abstract text available
    Text: V-EA-Series - UL508 Manual Motor Controller - 3 pole D-Trip Weight: 0.3A - 32A 1.8kg 3.97 lb. 40A - 63A 1.98kg (4.37 lb.) Three Pole 35 mm (1.38 in.) 93.3 mm (3.67 in.) 74.7 mm (2.94 in.) 52.5 mm (2.07 in.) 1.13-1.45xIN Minutes 60 40 10 Thermal Overload


    Original
    PDF UL508 45xIN 4x10-2 E137938 3D03UM 3D05UM 3D075UM 3D10UM 3D13UM 3D15UM D-Trip

    HG4138

    Abstract: UL873 HG4138 RELAY
    Text: HG4138 Miniature PCB / QC Power Relay FEATURES 30A switching capacity PCB + QC termination Meets UL508 and UL873 spacing requirements TYPICAL APPLICATIONS Power supply device Industrial control Home appliances Heating, refrigeration, ventilation CONTACT RATING


    Original
    PDF HG4138 UL508 UL873 277VAC/30VDC 155KVA 54KVA 77KVA 5VDC/12VAC 240VAC 28VDC HG4138 UL873 HG4138 RELAY

    E-Trip

    Abstract: No abstract text available
    Text: V-EA-Series - UL508 Manual Motor Controller - 3 pole E-Trip Three Pole 35 mm 1.38 in. 93.3 mm (3.67 in.) 74.7 mm (2.94 in.) 52.5 mm (2.07 in.) V-EA-E Trip 0.3A Through 10A Rated Current Minutes 1.05-1.35xIN 60 40 10 Thermal Overload “Must Trip” < 1 hr = 135% RC


    Original
    PDF UL508 35xIN 4x10-2 3E03UM 3E05UM 3E075UM 3E10UM 3E12UM 3E13UM 3E15UM E-Trip

    Untitled

    Abstract: No abstract text available
    Text: V-EA-Series - UL508 Manual Motor Controller - 3 pole D-Trip Three Pole 91.5 mm 3.60 in. 35 mm (1.38 in.) 70 mm (2.76 in.) 52.5 mm (2.07 in.) 1.13-1.45xIN UL 60 40 Minutes UL UL UL Thermal Overload “Must Trip” < 1 hr = 145% RC “Must Not Trip” > 1 hr = 113% RC


    Original
    PDF UL508 45xIN 4x10-2 4x10-3 480Y/277VAC 42VDC; 80VDCrrent 1BR20 1BU20.

    Untitled

    Abstract: No abstract text available
    Text: V-EA-Series - UL508 Manual Motor Controller - 1 pole G-Trip One Pole 91.5 mm 3.60 in. 35 mm (1.38 in.) 70 mm (2.76 in.) 17.5 mm (0.69 in.) Minutes UL UL UL UL 10 Thermal Overload “Must Trip” = 125% Rated Current “Must Not Trip” < 1 hr = 135% RC “Must Not Trip” > 1 hr = 105% RC


    Original
    PDF UL508 4x10-2 4x10-3 35xIN 1BR20 1BU20. E137938 1GU03

    MEH-32-115

    Abstract: 63H22A
    Text: Manual Motor Starters UL508 Type E MMS Series UL508 Type E E252942 Manual Motor Starters Standards and Certifications • UL508 Manual Motor Controller • UL508 (Type E self-protected Manual Motor Controller) • CSA C22.2 No.14 • IEC 60947-2 & IEC 60947-4-2


    Original
    PDF UL508 UL508 E252942 MEH-32-115 63H22A

    B-Trip

    Abstract: No abstract text available
    Text: V-EA-Series - UL508 Manual Motor Controller - 3 pole B-Trip Weight: 0.3A - 32A 1.8kg 3.97 lb. 40A - 63A 1.98kg (4.37 lb.) Three Pole 35 mm (1.38 in.) 93.3 mm (3.67 in.) 74.7 mm (2.94 in.) Minutes 1.13-1.45xIN 60 40 10 Thermal Overload “Must Trip” < 1 hr = 145% RC


    Original
    PDF UL508 45xIN 4x10-2 E137938 3B10UM 3B13UM 3B15UM 3B16UM 3B20UM 3B25UM B-Trip

    D-Trip

    Abstract: No abstract text available
    Text: V-EA-Series - UL508 Manual Motor Controller - 1 pole D-Trip One Pole 35 mm 1.38 in. 93.3 mm (3.67 in.) 74.7 mm (2.94 in.) 17.5 mm (0.69 in.) Voltage Rating Short Circuit Withstand Rating (UL/CSA - Ratings) Group Short Circuit Withstand Rating (UL/CSA - Ratings)


    Original
    PDF UL508 45xIN 4x10-2 4x10-3 E137938 1D03UM 1D05UM 1D075UM 1D10UM 1D13UM D-Trip

    HWS1500-60

    Abstract: No abstract text available
    Text: HWS300-1500 Series Single Output Industrial Power Supplies Features u Limited Lifetime Warranty u UL508 approved u SEMI F47 Compliant high line AC u Universal Input (85 - 265VAC) u High Efficiency u Class 1 Div 2 option (/RY suffix) u Wide Range AC Input


    Original
    PDF HWS300-1500 UL508 265VAC) 47-63Hz) 240VAC, 2V-48V HWS50-1500/HD HWS30-1500/ME UL60601-1, EN60950-1 HWS1500-60

    105A 9A

    Abstract: E43641 16-9ADIN1 9AS5D52-12 9AS1D52-110 9AS1D52-24 AC relays magnecraft 172
    Text: 9A Miniature Power Relays/SPST and SPDT 30 Amp Rating DC and AC Class F Insulation for max coil temperature of 155˚C Small Size Meets UL873 & UL508 Spacing (8mm through air, 9.5mm over surface) Quick-Connect Terminals for simple connection Flange Mounting


    Original
    PDF UL873 UL508 E43641 Perfor9AS5A52-240 105A 9A E43641 16-9ADIN1 9AS5D52-12 9AS1D52-110 9AS1D52-24 AC relays magnecraft 172

    SUGAR CUBE RELAY

    Abstract: G5LC-14-EU G5LC1AEU g5lc-1-eu SUGAR CUBE RELAY 12 G5LC-1 sugar production process cube relay omron g5lc-1-eu relay pcb 24 v spdt
    Text: PCB Power Relay – G5LC-EU A Cubic, Single-pole 10-A Power Relay • ROHS compliant. ■ Subminiature ‘sugar cube’ relay with universal terminal footprint. ■ Conforms to EN 61810-1, UL508, CSA22.2. ■ High switching power: 10 A. 250 VAC :4+ ■ Two types of seal available; flux protection


    Original
    PDF UL508, CSA22 G5LC-14-EU SUGAR CUBE RELAY G5LC-14-EU G5LC1AEU g5lc-1-eu SUGAR CUBE RELAY 12 G5LC-1 sugar production process cube relay omron g5lc-1-eu relay pcb 24 v spdt

    G5G-1A

    Abstract: E41515 Magnetron 1.5 kW magnetron* -coaxial microwave oven magnetron UL508 CSA22 LR31928 K110-E1-1 g5g1a
    Text: Special-purpose PCB Relay G5G Ideal for Microwave Oven Magnetrons and Heater Switching • ■ ■ ■ Conforms to IEC 255 TÜV approval , UL508, CSA22.2. Slim relay with high switching power: 16 A. Dual #187 tab/PCB terminals. High impulse withstand voltage: 10 kV.


    Original
    PDF UL508, CSA22 K110-E1-1 G5G-1A E41515 Magnetron 1.5 kW magnetron* -coaxial microwave oven magnetron UL508 LR31928 K110-E1-1 g5g1a

    S12W

    Abstract: No abstract text available
    Text: POWER RELAY 1 POLE—1, 3, 5, 10 A CADMIUM FREE CONTACTS TYPE LZG SERIES DI • FEATURES ● ● ● ● ● ● ● ● UL (UL372, UL508, UL873), CSA, VDE 4 kinds of contact ratings —Low level to 10 amps switching Standard and high sensitivity types available


    Original
    PDF UL372, UL508, UL873) S12W

    EN50081-1

    Abstract: SL10
    Text: 5 A with power boost CB scheme SL5.100 IEC60950 Data sheet UL508 LISTED IND. CONT. EQ. 18 WM, 60°C • • • • • • Input: AC 230V / 115V Output: 24V / 5A Power boost up to 6A High overload current, no switch-off Quasi-Wide-Range Input Robust mechanics and EMC


    Original
    PDF IEC60950 UL508 AC100-120/220-240 D-81925 sl5e100 EN50081-1 SL10