Text: C U S T O M E R T E R M IN A L RoHS L E A D P b -F R E E Sn96%, Ag4% Yes Yes I / ¿c o m p lia n t k O w l> M ID C 0 M ELECTRICAL SPECIFICATIONS 25°C u n le ss oth erw ise n oted: 3Q D.C. RESISTANCE (® 20?): 1 - 3 , 0.08 oh m s m ax . INDUCTANCE: 490uH + 1 0 0 /- 5 0 u H , 10kHz, 250mVAC, 1 - 3 , Ls.
|
OCR Scan
|
490uH
10kHz,
250mVAC,
|
PDF
|
smsi 2.5 AC
Abstract: smsi SMSI 25 115736 smsi current smsi 0,25
Text: Monitoring Modules SMSI DC O Current monitors U p to 50mA Up to 250mA Current monitoring units with adjustable switching threshold Optocoupler output • 2 2 .5 m m - Monitoring the current flow permits functional control of individual devices. Schem atic circuit diagram /Tim ing diagram
|
OCR Scan
|
250mA
750mVA
250mA)
250mA
50VDC
100mA
24VAC
250mW
smsi 2.5 AC
smsi
SMSI 25
115736
smsi current
smsi 0,25
|
PDF
|
Untitled
Abstract: No abstract text available
Text: tß Semiconductor LM45B/LM45C SOT-23 Precision Centigrade Temperature Sensors The LM45 series are precision inleg rated-circuit temperature sensors, whose output voltage is linearly proportional to the Celsius Centigrade temperature. The LM45 does not re
|
OCR Scan
|
LM45B/LM45C
LM45B/LM45C
OT-23
|
PDF
|
111226
Abstract: smsi 2.5 AC smsi WEIDMULLER 111226 SMSI 25 HH22 smsi current
Text: Monitoring Modules SMSI AC R SMSI AC R SMSI AC R Current M onitor Up to 2.5A Up to 10A C urrent monitoring with relay ouput up to 5A W ithout switching threshold Current monitoring units w ith adjustable switching threshold Relay output K - 2 2 .5 m m -* j
|
OCR Scan
|
250VAC
48VDC
100mA
100mA
300VDC,
111226
smsi 2.5 AC
smsi
WEIDMULLER 111226
SMSI 25
HH22
smsi current
|
PDF
|
ul 508a exception sb4.2
Abstract: ul508a Ferraz Shawmut mccb circuit breaker DEVICE MARKING CODE table FUSES ul 508a exception sb4.1
Text: Tech Topics: Standards & Code Note 1 , Issue 1 Achieving Higher Short Circuit Current Ratings for Industrial Control Panels Steve Hansen Sr. Field Engineer Introduction Articles 409.110 and 670.3 in the National Electrical Code require industrial control panels to be
|
Original
|
TT-SCN1-001
Q2500
ul 508a exception sb4.2
ul508a
Ferraz Shawmut
mccb circuit breaker
DEVICE MARKING CODE table FUSES
ul 508a exception sb4.1
|
PDF
|
D6DA
Abstract: 1000VA 250MVA
Text: D6DA Timers – DELTA series Industrial design Width 22.5mm OFF delay without auxiliary voltage 4 time ranges 1 change over contact Technical data 1. Functions A Mechanical life: Electrical life: OFF delay without auxiliary voltage Switching frequency: 2. Time ranges
|
Original
|
10min
100ms
10min)
1000VA
10/min
100VA
750VA
1250VA
D6DA
250MVA
|