Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    XRAY TUBE Search Results

    XRAY TUBE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CR6KM-12A#B00 Renesas Electronics Corporation Thyristors, TO-220FN, /Tube Visit Renesas Electronics Corporation
    CR3AS-8ME#B00 Renesas Electronics Corporation Thyristors, MP-3A, /Tube Visit Renesas Electronics Corporation
    CR6LM-12B#B00 Renesas Electronics Corporation Thyristors, TO-220FL, /Tube Visit Renesas Electronics Corporation
    CR3PM-12G-A8#B00 Renesas Electronics Corporation Thyristors, TO-220F, /Tube Visit Renesas Electronics Corporation
    CR8KM-12A#B00 Renesas Electronics Corporation Thyristors, TO-220FN, /Tube Visit Renesas Electronics Corporation

    XRAY TUBE Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    c6086-90

    Abstract: scintillator C6086 C6086-03 C6086-04 C6086-13 C6086-14 C6086-23 C6086-24 C6086-53
    Text: X-Ray CCD Camera DATA SHEET C6086 Series The C6086 series is a compact, lightweight, high resolution X-ray CCD camera. It consists of an Xray sensitive scintillator P43 coated on a tapered fiberoptic bundle direct coupled to a CCD camera. The C6086-90 camera controller incorporates a


    Original
    C6086 C6086-90 10-bit A6649 C6086-03, C6086-53, C6086-13, C6086-23, scintillator C6086-03 C6086-04 C6086-13 C6086-14 C6086-23 C6086-24 C6086-53 PDF

    x-ray tube

    Abstract: x-ray tube datasheet microfocus x-ray x-ray tube operation l8121 L8121-03 IEC-61326-1 IEC61326-1 IEC61010-1 scintillator
    Text: 150 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L8121-03 FEATURES ● Focal Spot Size: 5 µm at 4 W The focal spot of 5 µm of the sealed type X-ray tube offers sharp and clear X-ray images even at a high magnification. ● High Power: 75 W Allows continuous operation with a maximum output of 150 kV


    Original
    L8121-03 RS-232C SE-171-41 TLSO1057E03 x-ray tube x-ray tube datasheet microfocus x-ray x-ray tube operation l8121 L8121-03 IEC-61326-1 IEC61326-1 IEC61010-1 scintillator PDF

    X-RAY thickness

    Abstract: x-ray tube L9631 X-RAY INSPECTION x-ray tube datasheet t6.3a 250v microfocus x-ray x-ray x-ray tube operation C7716-10
    Text: 110 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9631 Optimum for In-line X-ray Inspection System FEATURES ●High Output: 800 µA 50 W It allows continuous maximum output. ●High Stability ●Serial Port Control (RS-232C) One package of a sealed type X-ray tube, a high-voltage power


    Original
    L9631 RS-232C) SE-171-41 TLSO1053E05 X-RAY thickness x-ray tube L9631 X-RAY INSPECTION x-ray tube datasheet t6.3a 250v microfocus x-ray x-ray x-ray tube operation C7716-10 PDF

    Untitled

    Abstract: No abstract text available
    Text: 100 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L10101 Short FOD: 6.8 mm TLSOF0185 FEATURES ●Short FOD Focus to Object Distance : 6.8 mm X-ray image with Higher Magnification ratio ●High Power: Maximum Output 20 W ●Focal Spot Size: 5 µm (at 4 W) The focal spot of 5 µm of the sealed type X-ray tube enables


    Original
    L10101 TLSOF0185 SE-171-41 TXPR1012E01 PDF

    Untitled

    Abstract: No abstract text available
    Text: 90 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9421-02 FEATURES ● Focal Spot Size: 5 µm at 4 W The focal spot of 5 µm of the sealed type X-ray tube enables sharp and clear X-ray images even at a high magnification. ●Easy Handling Fully operable from an external PC.


    Original
    L9421-02 RS-232C) SE-171-41 TXPR1011E01 PDF

    x-ray tube

    Abstract: x-ray tube datasheet L10101 microfocus x-ray x-ray C7716 C7716-10 C7876-10 IEC61326-1 50 kv
    Text: 100 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L10101 Short FOD: 6.8 mm TLSOF0185 FEATURES ●Short FOD Focus to Object Distance : 6.8 mm X-ray image with Higher Magnification ratio ●High Power: Maximum Output 20 W ●Focal Spot Size: 5 µm (at 4 W) The focal spot of 5 µm of the sealed type X-ray tube enables


    Original
    L10101 TLSOF0185 SE-171-41 TLSO1062E04 x-ray tube x-ray tube datasheet L10101 microfocus x-ray x-ray C7716 C7716-10 C7876-10 IEC61326-1 50 kv PDF

    HAMAMATSU L9181

    Abstract: L9181-02 intensifier x-ray tube L9181 X-RAY thickness IEC61326 L9181 x-ray x-ray tube datasheet C7716
    Text: 130 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9181-02 FEATURES ●Focal Spot Size: 5 µm at 4 W Sealed type X-ray tube with 5 µm focal spot allows clear X-ray images even at a high magnification. ●Easy Handling Fully operable from external PC. ●Serial Port Control (RS-232C)


    Original
    L9181-02 RS-232C) SE-171-41 TLSO1061E01 HAMAMATSU L9181 L9181-02 intensifier x-ray tube L9181 X-RAY thickness IEC61326 L9181 x-ray x-ray tube datasheet C7716 PDF

    Untitled

    Abstract: No abstract text available
    Text: 110 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9631 Optimum for In-line X-ray Inspection System FEATURES ●High Output: 800 µA 50 W It allows continuous maximum output. ●High Stability ●Serial Port Control (RS-232C) One package of a sealed type X-ray tube, a high-voltage power


    Original
    L9631 RS-232C) SE-171-41 TXPR1014E01 PDF

    Untitled

    Abstract: No abstract text available
    Text: X-RAY I.I. DIGITAL CAMERA X-RAY UNIT SERIES IMAGING C7336-05/-52 •BGA ●Digital type C7336-05 Clear, Sharp Image X-ray tube voltage: 80 kV ●Analog type OVERVIEW The C7336 series consist of a high resolution, high contrast 4inch X-ray image intensifier (X-ray I.I.) and a 2.8 megapixel


    Original
    C7336-05/-52 C7336-05) C7336 IEEE1394b. SE-164 TXPR1017E04 B1201 PDF

    Untitled

    Abstract: No abstract text available
    Text: 130 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9181-05 FEATURES ●Easy Handling Fully operable from an external PC. ●Serial Port Control RS-232C One package of a sealed type X-ray tube, a high-voltage power supply and a control function. ●Continuous Operation: 39 W


    Original
    L9181-05 RS-232C) SE-171-41 TXPR1004E02 PDF

    Untitled

    Abstract: No abstract text available
    Text: 130 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9181-02 FEATURES ● Focal Spot Size: 5 µm at 4 W Sealed type X-ray tube with 5 µm focal spot allows clear X-ray images even at a high magnification. ●Easy Handling Fully operable from external PC. ●Serial Port Control (RS-232C)


    Original
    L9181-02 RS-232C) SE-171-41 TXPR1015E01 PDF

    VICTOREEN model 500

    Abstract: intensifier phosphor p20 VICTOREEN V3732P image intensifier -X-ray image intensifiers cesium iodide iodide V3733P
    Text: X-RAY IMAGE INTENSIFIERS High DQE • Excellent Image Quality • High Contrast An X-ray image intensifier is a large image tube that converts a low intensity X-ray image into a visible image. It is used for medical X-ray TV systems, X-ray nondestructive inspection systems,


    Original
    S-164 1004E03 VICTOREEN model 500 intensifier phosphor p20 VICTOREEN V3732P image intensifier -X-ray image intensifiers cesium iodide iodide V3733P PDF

    L9421-02

    Abstract: L9421 x-ray tube datasheet sharp ccd x-ray C7716 C7716-10 C7876-10 H8480 H8953
    Text: 90 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9421-02 FEATURES ● Focal Spot Size: 5 µm at 4 W The focal spot of 5 µm of the sealed type X-ray tube enables sharp and clear X-ray images even at a high magnification. ●Easy Handling Fully operable from an external PC.


    Original
    L9421-02 RS-232C) SE-171-41 TLSO1055E03 L9421-02 L9421 x-ray tube datasheet sharp ccd x-ray C7716 C7716-10 C7876-10 H8480 H8953 PDF

    Untitled

    Abstract: No abstract text available
    Text: 110 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L10951 FEATURES ●High Power: Maximum Output 50 W ●High Stability ●Serial Port Control RS-232C One package of a sealed type X-ray tube, a high-voltage power supply and a control function. ●Easy Handling


    Original
    L10951 RS-232C) SE-171-41 TXPR1002E03 PDF

    L9191

    Abstract: L9181 L9181-02 HAMAMATSU L9191 X-RAY INSPECTION AC Photonics C7336 C7716 C7876-10 l919
    Text: X-RAY I.I. CAMERA UNIT SERIES X-RAY C7336-50/-51, C7876/-10, C7716/-10 IMAGING X-ray Image Intensifier X-ray I.I. + CCD Camera High-quality X-ray images. Both low energy and high magnification are available. ▲Flower (C7876, X-ray tube voltage: 10 kV) ▲BGA


    Original
    C7336-50/-51, C7876/-10, C7716/-10 C7876, C7716, C7876/-10) C7336-50/-51 C7716/-10) LC7336-50/-51, L9191 L9181 L9181-02 HAMAMATSU L9191 X-RAY INSPECTION AC Photonics C7336 C7716 C7876-10 l919 PDF

    Untitled

    Abstract: No abstract text available
    Text:  X-RAY X-CUBE COMPACT X-RAY CCD CAMERAS IMAGING H8480/H8481/H8953 Series SAMPLE X-RAY IMAGES Sample: Cellular phone substrate X-ray tube voltage: 90 kV, Geometrical magnification rate: x1.15 H8480 Effective view: 25 mm Min. Resolution : 10 Lp/mm Typ. H8481


    Original
    H8480/H8481/H8953 H8480 H8481 H8953 H8480 25Tewin SE-164 TXPR1020E01 PDF

    Untitled

    Abstract: No abstract text available
    Text:  X-RAY X-CUBE COMPACT X-RAY CCD CAMERAS IMAGING H8480/H8481/H8953 Series SAMPLE X-RAY IMAGES Sample: Cellular phone substrate X-ray tube voltage: 90 kV, Geometrical magnification rate: x1.15 H8480 Effective view: 25 mm Min. Resolution : 10 Lp/mm Typ. H8481


    Original
    H8480/H8481/H8953 H8480 H8481 H8953 H8480 SE-171-41 TAPP1056E02 PDF

    x-ray tube

    Abstract: AC Photonics H8953 scintillator x-ray tube datasheet H8480 H8481 H8481-15 rear CCD camera VA-033B
    Text:  X-RAY X-CUBE COMPACT X-RAY CCD CAMERAS IMAGING H8480/H8481/H8953 Series SAMPLE X-RAY IMAGES Sample: Cellular phone substrate X-ray tube voltage: 90 kV, Geometrical magnification rate: x1.15 H8480 Effective view: 25 mm Min. Resolution : 10 Lp/mm Typ. H8481


    Original
    H8480/H8481/H8953 H8480 H8481 H8953 H8480 SE-171-41 TAPP1056E02 x-ray tube AC Photonics H8953 scintillator x-ray tube datasheet H8481 H8481-15 rear CCD camera VA-033B PDF

    xenon linear flash lamps

    Abstract: Lamps FLASH TUBE xenon Solar Garden Light Controller 4 pin deuterium lamp circuit C8855-01 C9744 uv light PHOTO detector xenon flash lamps led optical communication uv flame sensor
    Text: Photon is our business Electron Tube Products Condensed Catalog HAMAMATSU PHOTONICS K.K. E l e c t r o n T u Development and production centers for light sensors, light sources, and application-specific products utilizing light to support a wide range of needs in medical diagnosis/treatment, chemical analysis,


    Original
    B-1348 E-08290 OTH0016E02 xenon linear flash lamps Lamps FLASH TUBE xenon Solar Garden Light Controller 4 pin deuterium lamp circuit C8855-01 C9744 uv light PHOTO detector xenon flash lamps led optical communication uv flame sensor PDF

    500/250/arc xenon flash lamps

    Abstract: No abstract text available
    Text: Electron Tube Products Condensed Catalog HAMAMATSU PHOTONICS K.K. Development and production centers for light sensors, light sources, and application-specific products utilizing light to support a wide range of needs in medical diagnosis/treatment, chemical analysis,


    Original
    OTH0016E06 500/250/arc xenon flash lamps PDF

    TV20

    Abstract: x-ray tube heat E8-11 AWM3239 N7599-01 TV-20 N7599 internal diagram of 741 IC
    Text: TRANSMISSION MODE NEW SOFT X-RAY TUBE N7599, N7599-01 HIGH STABILITY 1% 10 % ●Fluctuation Characteristics 10 min 10 min Block diagram for measurement 10 mm SOFT X-RAY TUBE N7599 DIGITAL MULTI METER Al FILM POWER SUPPLY OVER VIEW The N7599, N7599-01 is a compact, end-window


    Original
    N7599, N7599-01 N7599 N7599-01 SE-171-41 TV20 x-ray tube heat E8-11 AWM3239 TV-20 N7599 internal diagram of 741 IC PDF

    Untitled

    Abstract: No abstract text available
    Text: Fairchild Imaging Sensors Application Note: X-Ray Imaging with CC D Image Sensors by R.H. Dyck X-ray imaging is conventionally done with either photographic film, X-ray phosphor screens viewed directly, or X-ray image converter tubes coupled to a vidicon-type of television camera.


    OCR Scan
    PDF

    Readout Tubes

    Abstract: image sensor x-ray light source xenon flash tube tv camera tubes Lamps FLASH TUBE xenon
    Text: Photosensitive Electron Tubes Features Applications Spectroscopy, High energy physics, Medical use, Space, Pollution monitoring, etc. Page 2 Phototubes Super high sensitivity, Low noise, High speed response, Wide variety High speed response, Low noise, Excellent linearity,


    OCR Scan
    PDF

    Electron Tubes crt

    Abstract: Readout Tubes Geiger-muller tv camera tubes light source xenon flash tube
    Text: I Photosensitive Electron Tubes Features Applications Photomultiplier Tubes Super hjgh se nsitivity, Low noise, High speed response, W id e variety S pectroscopy, High energy physics, M edical use. Space, P ollution m onitoring, etc 2 Phototubes High speed response, Low noise, E xce lle n t linearity,


    OCR Scan
    PDF