Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    XPS-AL* PREVENTA Search Results

    XPS-AL* PREVENTA Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    AM1-DP200

    Abstract: XPS-ot XPS-AS preventa safety GNKL AM1DP200 XPS-AT XPS-ASf xps-ecp Preventa xps-al
    Text: Components for safety applications Preventa safety modules Dimensions, mounting XPS-AL, XPS-AX AM1-DP200 rail mounting 78 78 1 120 22,5 78 78 XPS-AT, XPS-FB, XPS-AM, XPS-AMF, XPS-AP, XPS-APF, XPS-ECM, XPS-ECP, XPS-NS, XPS-VN AM1-DP200 rail mounting 120 90


    Original
    PDF AM1-DP200 M1-DP200 XPS-ot XPS-AS preventa safety GNKL AM1DP200 XPS-AT XPS-ASf xps-ecp Preventa xps-al

    XPSAL5110

    Abstract: XPS-AC5121 XPSAC5121 XPS-AC XPS-AL XPS-AL5110 XPSAC3721 xpsal3710 XPSAC3421 XPS-AC3721
    Text: Product Substitution Details - Safety Modules XPS-AL Replaced by XPS-AC Differentiation n XPS-AC has one extra N/O safety output n XPS-AC has a solid state output for PLC signalling n XPS-AC has choice of removable plug terminals Schematic Comparison Monitoring of E-stop with 2N/C contacts


    Original
    PDF 24VDC 24VDCK1 24VAC/DC XPS-AL5110 XPS-AC5121 48VAC XPS-AC1321 120VAC XPS-AL3410 XPSAL5110 XPS-AC5121 XPSAC5121 XPS-AC XPS-AL XPS-AL5110 XPSAC3721 xpsal3710 XPSAC3421 XPS-AC3721

    XPS-AT

    Abstract: XPS-AT3410 XPSAT5110 XPSAL5110 Preventa xps-al XPS-AL XPS-AT5110 XPSAt XPS-AL3710 XPS-AL5110
    Text: Components for safety applications Preventa safety modules for emergency stop and limit switch monitoring Operating principle, characteristics Operating principle 1 Preventa XPS-AL and XPS-AX safety modules are used to monitor emergency stop circuits, conforming to the standards


    Original
    PDF

    interlock solenoid

    Abstract: XCS-Z05 preventa safety schneider XCS L schneider ZCK XCK J xcs schneider guard master limit switch IEC 60947-5-1 apar XPS AL
    Text: XCS LE / XCS LF www.schneider-electric.com Safety interlock switch Original instruction / Interrupteurs de sécurité (Notice originale) / Sicherheits-Positionsschalter (Übersetzung der Originalanweisungen) / Interruptores de seguridad (Traducción de las instrucciones


    Original
    PDF

    XCS-P3918

    Abstract: preventa xps XCS-D3902 XCS-D3918 XCS-D3702 XCS-D3910 XCSD3902 XCS-P3919 XCSD XCS-D3719
    Text: XCS-D3•18••• XCS-P3•18••• XCS-D3•19••• XCS-P3•19••• Contact closed 1 Contact fermé (1) Kontakt geschlossen (1) Contacto cerrado (1) Contatto chiuso (1) Contacto fechado (1) XCS-D = metal body XCS-P = plastic body English


    Original
    PDF AC-15, DC-13, W916347410111 XCS-P3918 preventa xps XCS-D3902 XCS-D3918 XCS-D3702 XCS-D3910 XCSD3902 XCS-P3919 XCSD XCS-D3719

    IEC 68-2-27

    Abstract: XPS al XCS-M3902L 68227 XCS-M3715L XCS-M3916L XCS-M4102L IEC 68-2-6 XCS-M4116L W915758080111
    Text: Contact closed 1 Contact fermée (1) Kontakt geschlossen (1) Contacto cerrado (1) Contatto chiuso (1) Contacto fechado (1) L• => L1 : 1 m cable L• => L2 : 2 m cable L• => L5 : 5 m cable Português Los aparatos han sido diseñados según las normas


    Original
    PDF AC-15, DC-13, W915758080111 IEC 68-2-27 XPS al XCS-M3902L 68227 XCS-M3715L XCS-M3916L XCS-M4102L IEC 68-2-6 XCS-M4116L