Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TUBE CONDUIT Search Results

    TUBE CONDUIT Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    10137969-001LF Amphenol Communications Solutions OCTIS™ - Input Output, Accessory, Flexible Extension Tube 400 mm Visit Amphenol Communications Solutions
    RJE1J1660110B Amphenol Communications Solutions Modular Jack - 6P6C, Vertical, Single Port, Narrow Profile, No Shield, No LEDs, Tube Packaging Visit Amphenol Communications Solutions
    BC6288H03001 Amphenol Communications Solutions Spring Battery Connector,T/H,5.30mm pitch 3 positions, 15u\\ Au LCP Black, Tube Visit Amphenol Communications Solutions
    G809309131DEU Amphenol Communications Solutions PCB Socket 1.27mm Pitch, STR Surfacemount, 1x9Pin, G/F, NY6T, W=1.8mm, 4.6mm_3.2mm, TUBE Visit Amphenol Communications Solutions
    RJE1J1440110B Amphenol Communications Solutions Modular Jack - 4P4C, Vertical, Single Port, Narrow Profile, No Shield, No LEDs, Tube Packaging Visit Amphenol Communications Solutions
    SF Impression Pixel

    TUBE CONDUIT Price and Stock

    ITT Interconnect Solutions 90 -ENDBELL-FLEX-TUBE-(APD

    90 Endbell Adapter ,black, øA 18, Dimension of Conduit 17
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Onlinecomponents.com 90 -ENDBELL-FLEX-TUBE-(APD
    • 1 -
    • 10 -
    • 100 -
    • 1000 $5.28
    • 10000 $5.28
    Buy Now

    TUBE CONDUIT Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    UL1666

    Abstract: UL-1666 230um bicc* cable
    Text: Page 1 of 2 LTR Loose Tube Riser Cables Loose tube, riser rated cable is the solution for continuous cable runs between and within buildings. These loose tube cables provide the maximum protection for outdoor installations in ducts, conduits or aerial-lashed. They are also riser rated UL-1666 OFNR


    Original
    UL-1666 UL1666 230um bicc* cable PDF

    AF200

    Abstract: AF200K12
    Text: DESCRIPTION Connect the tube, dynamic pressure to the “+" port and static to the port, using the flexible tube and connectors supplied with the airflow kit AF200K12 or AF200K18 . Ensure that the ends of the tube are separated by 10-15mm to avoid bends causing air blockage.


    OCR Scan
    AF200K12 AF200K18) 10-15mm AF200 PDF

    Untitled

    Abstract: No abstract text available
    Text: Stranded Loose Tube Outdoor Cable, A-DQ ZN 2Y 10x12 G50/125 CC (OM4) 217.4606 Corning Cable Systems Stranded Loose Tube cables are designed for outdoor use for campus, city and intercity backbones in duct installations. Corning Cable The loose-tube cable construction, by isolating the fibers


    Original
    10x12 G50/125 FWLT01-S0120-K001 FWLT01-S0120-K001 PDF

    Untitled

    Abstract: No abstract text available
    Text: ALTOS Loose Tube Steel Armour Double Jacket Outdoor Cable 1x4 E9/125 OS2 Corning stranded loose tube cables with corrugated steel armouring are designed for outdoor use for campus, city and intercity backbones in duct and direct burial installations. The loose tube cable construction, by isolating the fibres


    Original
    E9/125 FWLT01-S0004-U006 PDF

    MIL-S-24235

    Abstract: tube conduit BB 313 q 406 813 tube fitting
    Text: Conduit & Accessories M24758/7 Conduit-to-Stuffing Tube Fitting M24758/7-04-B-A Material Designator: A = Aluminum B = Brass C = CRES 316 Basic Part No. Conduit Size Code Stuffing Tube Size Code Tapered Sleeve H L P Conduit A Dia M Dia Coupling Nut A Thread


    Original
    M24758/7 M24758/7-04-B-A MIL-S-24235/9 MIL-S-24235/17 M24758/1 MIL-S-24235 tube conduit BB 313 q 406 813 tube fitting PDF

    MIL-S-24235

    Abstract: BB 313 q 406 813 M-247 tube conduit
    Text: Conduit Systems M24758/7 Conduit-to-Stuffing Tube Fitting M24758/7-04-B-A Basic Part No. Material Designator: A = Aluminum B = Brass C = CRES 316 Conduit Size Code Stuffing Tube Size Code Tapered Sleeve H L P Conduit A Dia M Dia Coupling Nut A Thread Q J Straight Knurl


    Original
    M24758/7 M24758/7-04-B-A MIL-S-24235/9 MIL-S-24235/17 M24758/1 MIL-S-24235 BB 313 q 406 813 M-247 tube conduit PDF

    Untitled

    Abstract: No abstract text available
    Text: Baumer T02 Thermocouple Assembly With Single / Double Protecting tube Flanged / Screwed connection Special Features Assembly with KER 710 or KER 610 tube for high temperature application. Thermocouple element is available in different wire sizes.


    Original
    PDF

    philips ET-E 60

    Abstract: T150
    Text: O o PHILIPS DCG DCG 7/100B Grid-controlled MERCURY VAPOUB RECTIFYING TUBE TUBE REDRESSEUR A VAPEUR DE MERCURE a grille Glttergesteuerte GLEICHRICHTERF.O'HRE MIT QUECKSILBERDAliPFFULLUNG Cathode Cathode Katode :oxide-coated :oxyde :Oxyd. Heating : Indirect, k connected to f


    OCR Scan
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Stranded Loose Tube MPC Cable, Corrugated Steel Armouring, A-DQ ZN (SR)H 4x6 G62.5/125 (OM1) 219.9868 Corning Cable Systems MPC (Multi Purpose Cable) Stranded Loose Tube Cables are flame retardant, indoor/ outdoor and designed for interbuilding / intrabuilding


    Original
    FWLT01-N6024-A007 4x6G62 FWLT01-N6024-A007 PDF

    Untitled

    Abstract: No abstract text available
    Text: Stranded Loose Tube MPC Cable, Corrugated Steel Armouring, A-DQ ZN (SR)H 3x12 E9/125 (OS2) 219.9868 Corning Cable Systems MPC (Multi Purpose Cable) Stranded Loose Tube Cables are flame retardant, indoor/ outdoor and designed for interbuilding / intrabuilding


    Original
    E9/125 FWLT01-S0036-U007 3x12E9/125 FWLT01-S0036-U007 PDF

    MIL-PRF-24758-39

    Abstract: No abstract text available
    Text: MIL-PRF 24758A MIL-PRF-24758-39 45° Elbow • Conduit to Stuffing Tube Basic Number A Stuffing Tube Size Code Conduit Size Code Table II (Table I) M24758-39 C C See M24758-15 For Details See M24758-3 For Details F 45° Elbow O-Ring Chamfer Inside Edges


    Original
    4758A MIL-PRF-24758-39 M24758-39 M24758-15 M24758-3 M24758-* M24758-39 MIL-S-24235/9 MIL-S-24235/17 MIL-PRF-24758-39 PDF

    Untitled

    Abstract: No abstract text available
    Text: Stranded Loose Tube MPC Cable, Corrugated Steel Armouring, A-DQ ZN (SR)H 10x12 E9/125 (OS2) 219.9868 Corning Cable Systems MPC (Multi Purpose Cable) Stranded Loose Tube Cables are flame retardant, indoor/ outdoor and designed for interbuilding / intrabuilding


    Original
    10x12 E9/125 FWLT01-S0120-U007 FWLT01-S0120-U007 PDF

    Untitled

    Abstract: No abstract text available
    Text: Stranded Loose Tube MPC Cable, Corrugated Steel Armouring, A-DQ ZN (SR)H 4x6 E9/125 (OS2) 219.9868 Corning Cable Systems MPC (Multi Purpose Cable) Stranded Loose Tube Cables are flame retardant, indoor/ outdoor and designed for interbuilding / intrabuilding


    Original
    E9/125 FWLT01-N6024-U007 4x6E9/125 FWLT01-N6024-U007 PDF

    Untitled

    Abstract: No abstract text available
    Text: Stranded Loose Tube MPC Cable, Corrugated Steel Armouring, A-DQ ZN (SR)H 12X12 G62.5/125 (OM1) 219.9868 Corning Cable Systems MPC (Multi Purpose Cable) Stranded Loose Tube Cables are flame retardant, indoor/ outdoor and designed for interbuilding / intrabuilding


    Original
    12X12 FWLT01-S0144-A007 12x12G62 FWLT01-S0144-A007 PDF

    Untitled

    Abstract: No abstract text available
    Text: Stranded Loose Tube MPC Cable, Corrugated Steel Armouring, A-DQ ZN (SR)H 10X12 G62.5/125 (OM1) 219.9868 Corning Cable Systems MPC (Multi Purpose Cable) Stranded Loose Tube Cables are flame retardant, indoor/ outdoor and designed for interbuilding / intrabuilding


    Original
    10X12 FWLT01-S0120-A007 10x12G62 FWLT01-S0120-A007 PDF

    Untitled

    Abstract: No abstract text available
    Text: Stranded Loose Tube Outdoor Cable, GlassYarn Armouring 3x12 G50/125 CC OM2 219.9868 Corning Cable Systems Glass­-Yarn armored Loose­-Tube cables are designed for outdoor use for campus, city and intercity backbones in duct installations. Corning Cable


    Original
    G50/125 FWLT01-S0036-G003 FWLT01-S0036-G003 PDF

    Untitled

    Abstract: No abstract text available
    Text: Multipurpose Cables indoor/outdoor , Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4 - 24 Features and Benefits Laminated swelling glass yarns Improved rodent resistance and longitudinal water protection The MPC (Multi-Purpose Cables) central tube (indoor/


    Original
    00800-CORNING1) PDF

    Untitled

    Abstract: No abstract text available
    Text: Stranded Loose Tube MPC Cable, Corrugated Steel Armouring, A-DQ ZN (SR)H 8x12 G50/125 CC (OM2) 219.9868 Corning Cable Systems MPC (Multi Purpose Cable) Stranded Loose Tube Cables are flame retardant, indoor/ outdoor and designed for interbuilding / intrabuilding


    Original
    G50/125 FWLT01-S0096-G007 8x12G50/125 FWLT01-S0096-G007 PDF

    Untitled

    Abstract: No abstract text available
    Text: Stranded Loose Tube Outdoor Cable, GlassYarn Armouring 2x12 G50/125 CC OM4 219.9868 Corning Cable Systems Glass­-Yarn armored Loose­-Tube cables are designed for outdoor use for campus, city and intercity backbones in duct installations. Corning Cable


    Original
    G50/125 FWLT01-S0024-K003 FWLT01-S0024-K003 PDF

    Untitled

    Abstract: No abstract text available
    Text: Stranded Loose Tube MPC Cable, Corrugated Steel Armouring, A-DQ ZN (SR)H 4x6 G50/125 CC (OM2) 219.9868 Corning Cable Systems MPC (Multi Purpose Cable) Stranded Loose Tube Cables are flame retardant, indoor/ outdoor and designed for interbuilding / intrabuilding


    Original
    G50/125 FWLT01-N6024-G007 4x6G50/125 FWLT01-N6024-G007 PDF

    Untitled

    Abstract: No abstract text available
    Text: Stranded Loose Tube MPC Cable, Corrugated Steel Armouring, A-DQ ZN (SR)H 2x6 G50/125 CC (OM2) 219.9868 Corning Cable Systems MPC (Multi Purpose Cable) Stranded Loose Tube Cables are flame retardant, indoor/ outdoor and designed for interbuilding / intrabuilding


    Original
    G50/125 FWLT01-N6012-G007 2x6G50/125 FWLT01-N6012-G007 PDF

    Untitled

    Abstract: No abstract text available
    Text: Stranded Loose Tube MPC Cable, Corrugated Steel Armouring, A-DQ ZN (SR)H 6x12 G50/125 CC (OM4) 219.9868 Corning Cable Systems MPC (Multi Purpose Cable) Stranded Loose Tube Cables are flame retardant, indoor/ outdoor and designed for interbuilding / intrabuilding


    Original
    G50/125 FWLT01-S0072-K007 PDF

    Untitled

    Abstract: No abstract text available
    Text: Outdoor stranded loose tube cable minibundle A-DQ(ZN)2Y 12–144 LT, 2.25 mm tubes Features and Benefits Waterblocking technology OSP (outdoor) applications The outdoor stranded loose tube (minibundle) cables can be deployed outdoor for campus backbone. The cables


    Original
    60794-1-2-F5 00800-CORNING1) PDF

    0079_EMEA_BEN

    Abstract: No abstract text available
    Text: Indoor central tube cable maxibundle J-DH 4 -24 Features and Benefits All-dielectric cable construction Requires no grounding or bonding Low Fire Load Good performances in flame resistance, fire and smoke spread Corning Cable Systems central tube indoor cables are


    Original
    60332-3C 00800-CORNING1) 0079_EMEA_BEN PDF