Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TRANSFORMER 120A Search Results

    TRANSFORMER 120A Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    WB1040-SML Coilcraft Inc Transformer Visit Coilcraft Inc
    AS8426-A Coilcraft Inc Telecom Transformer Visit Coilcraft Inc Buy
    B0727-B Coilcraft Inc Telecom Transformer Visit Coilcraft Inc Buy
    AS8954-A Coilcraft Inc Telecom Transformer Visit Coilcraft Inc
    CR7984-CLD Coilcraft Inc Datacom Transformer Visit Coilcraft Inc

    TRANSFORMER 120A Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    SPW 078

    Abstract: pst 39 transformer Wabash Transformer spw -136 spw+-079+transformer 4-07-7016 MT12/SPW 078 spw -055 transformer pc-24-450 TRANSFORMER 4-44-5010
    Text: WabashTransformer.com ● Class 2, VDE, UL, CSA Recognized ● Zero Defect, 100 % Tested ● Competitive Prices ● Standard & Custom Designs ● 2 Year Warranty Table of Contents Product Description Class 2 CL UL5085-3 Transformer International Power Transformer


    Original
    PDF UL5085-3 SPW 078 pst 39 transformer Wabash Transformer spw -136 spw+-079+transformer 4-07-7016 MT12/SPW 078 spw -055 transformer pc-24-450 TRANSFORMER 4-44-5010

    ctd1x

    Abstract: No abstract text available
    Text: Accessories AC Current Transformer max 23mm φ cable Type CTD-1X • Cable and bus-bar type current transformer • 0.5 class, currents from 50 to 300 A • Removable DIN-rail mounting holder • Removable panel fixing clips • 2 cable/bus-bar isolated fixing screws


    Original
    PDF

    CTD 46

    Abstract: EN60044-1 ctd1x CTD-KIT A/CTD 46
    Text: Accessories AC Current Transformer max 23mm φ cable Type CTD-1X • Cable and bus-bar type current transformer • 0.5 class, currents from 50 to 300 A • Removable DIN-rail mounting holder • Removable panel fixing clips • 2 cable/bus-bar isolated fixing screws


    Original
    PDF

    clamp current transformer

    Abstract: CURRENT MEASURE TRANSFORMER current transformer power TRANSFORMER specification
    Text: Dual Range 'Clip-on' Current Transformer Stock number 654-613 General Safety Precautions The RS Dual range 'Clip-on' current transformer is a clamp type adaptor for measuring a.c. currents using the voltage ranges on any digital multimeter. In the 100A range, with the meter on a 200mV range direct


    Original
    PDF 200mV area15mA 200mV, clamp current transformer CURRENT MEASURE TRANSFORMER current transformer power TRANSFORMER specification

    triacs bt 16 600v

    Abstract: BTA16-600b application motor control BTa16-600bw application motor control BTA26-600B diagram triacs bt 12 600v ac motor triac bta12 circuit diagram BTA16-600B heating control diagram triac RC snubber circuit diagram induction heating ac motor triac bta16 circuit diagram
    Text: AN441 APPLICATION NOTE TRIACS FOR MICROWAVE OVEN INTRODUCTION Triacs are now commonly used in microwave ovens as static switches to control the power transformer, the heating resistor for grill and sometimes the motor for plate rotation. The conditions of operation of triacs for transformer control and for heater control are analysed here after


    Original
    PDF AN441 triacs bt 16 600v BTA16-600b application motor control BTa16-600bw application motor control BTA26-600B diagram triacs bt 12 600v ac motor triac bta12 circuit diagram BTA16-600B heating control diagram triac RC snubber circuit diagram induction heating ac motor triac bta16 circuit diagram

    B0817

    Abstract: No abstract text available
    Text: Medium voltage fuses Medium voltage fuses Medium voltage fuses Medium voltage fuses European Fuses DIN Fuses 7.2kV - 36kV IBD 7.2 UP TO 36 KV HIGH-VOLTAGE FUSES DESIGNED FOR POWER TRANSFORMER PROTECTION INTERIOR/EXTERIOR USE CERAMIC HOUSING “MEDIUM” CLASS TRIP-INDICATOR


    Original
    PDF MV102 B0817

    Untitled

    Abstract: No abstract text available
    Text: XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series SEMI-REGULATED POWER SUPPLY Alternative or Replacement for AC Transformer Three Phase Input – DC Output DIN-Rail Mountable Width only 96mm 95.5% Efficiency 125% Peak Power Capability No Input Inrush Current


    Original
    PDF DS-XT40 24x-EN 3x400Vac 3x480Vac

    24-A

    Abstract: PF083A RB-08 "Current Monitors"
    Text: CMB SERIES AC Go/No-Go Current Monitor/Relays DIMENSIONS INCHES FEATURES • No physical connection to the AC line that is being monitored • Magnetically coupled by passing supply line through protruding Current Transformer WIRING CONTROL VOLTAGE • Heavy Duty Contacts


    Original
    PDF RB-08 PF083A 24-A PF083A "Current Monitors"

    Untitled

    Abstract: No abstract text available
    Text: C2403 REV D Product Description CEP7 Line Isolation Transformer EN60950 / 250V .339 Max [8.61] A COEV C2403 XXXXX .385 Max [9.78] 7.98 .314 1 8 2 7 3 6 4 5 .400 Max [10.16] 2.50 .098 TY P 5.74 .226 Coplanar with surface A +0.006"/-0.000" 100Ω 0.76 .030 TY P


    Original
    PDF C2403 EN60950 C2403 10kHz, 100mVAC, 120ADC, 100kHz,

    C2937

    Abstract: LS 2 0440
    Text: C2937 REV A Product Description CEP7 Line Isolation Transformer EN60950 / 250V .339 Max [8.61] A COEV C2937 XXXXX .385 Max [9.78] 7.98 .314 1 8 2 7 3 6 4 5 .400 Max [10.16] 2.50 .098 TY P 5.74 .226 Coplanar with surface A +0.006"/-0.000" 100Ω 0.76 .030 TY P


    Original
    PDF C2937 EN60950 C2937 10kHz, 100mVAC, 120ADC, 100kHz, LS 2 0440

    C2404

    Abstract: TY 1016
    Text: C2404 REV D Product Description CEP7 Line Isolation Transformer EN60950 / 250V .339 Max [8.61] A COEV C2404 XXXXX .385 Max [9.78] 7.98 .314 1 8 2 7 3 6 4 5 .400 Max [10.16] 2.50 .098 TY P 5.74 .226 Coplanar with surface A +0.006"/-0.000" 100Ω 0.76 .030 TY P


    Original
    PDF C2404 EN60950 C2404 10kHz, 100mVAC, 120ADC, 100kHz, TY 1016

    C300/M

    Abstract: No abstract text available
    Text: Three Phase Power Calibrator and Power Engineering Devices Tester C300 3- phase source up to 120A 1- phase up to 360A and 560V Calibrator / tester C300 is used for adjusting, checking and verification of measuring instruments used in power engineering. These include electricity


    Original
    PDF UCF100 CF100 CF101 RS232-Bluetooth 30V/50Hz Calpro300TS C300/M

    Untitled

    Abstract: No abstract text available
    Text: Landis+Gyr S650 Smart Grid Terminal A smart grid innovation Landis+Gyr S650 Smart Grid Terminal 2 Landis+Gyr S650 Smart Grid Terminal Emerging challenges in the distribution system. Utilities, both distribution network operators DNOs and distribution system operators (DSOs), are facing growing


    Original
    PDF

    KVM SWITCH schematic

    Abstract: video isolation transformer KVM SWITCH IC ELF COIL RECEIVER balun ntsc IC vertical panasonic VRS transformer EL4543 EL5111 EL5172
    Text: Technical Brief 485 By Rudy Berneike and David Laing Video Cat 5 CMV Rejection Networks Introduction NTSC/PAL and RGB/KVM Common Mode Voltage CMV requirements vary by application. In the US, ±3.5V of CMV will support most short to medium length cable CMV requirements. For


    Original
    PDF ISL5960X TB485 EL5172 EL5120 EL5111 KVM SWITCH schematic video isolation transformer KVM SWITCH IC ELF COIL RECEIVER balun ntsc IC vertical panasonic VRS transformer EL4543

    DC to DC step down converters 48V to 1.8V

    Abstract: GPLW5V060
    Text: LEO Series Industry’s Highest Current DC/DC Converter. 48V or 24V Input, 250W, 120A Output, 3.3V 90A, 2.5V 100A, 1.8V 120A, 1.5V 120A, 1.2V 120A standard with extra wide trim range The Leo is a 3/4 brick CoolConverter in the Galaxy family of high-efficiency


    Original
    PDF 600kHz, DC to DC step down converters 48V to 1.8V GPLW5V060

    HB relay

    Abstract: 1300gr
    Text: GEFLEX GFX-M1 / GFX-S1 / GFX-E1 MODULAR POWER CONTROLLER FOR TEMPERATURE CONTROLLED ZONES Main features • • • • • • • • • • • • • • Main applications • • • • • • • Plastic extruders Plastic injection presses Blowers


    Original
    PDF 480Vac E198546 2004/108/CE 2006/95/CE HB relay 1300gr

    Untitled

    Abstract: No abstract text available
    Text: SmartOnline 20kVA On-Line Double-Conversion UPS, N+1, 14U Rack/Tower, 208/120V or 240/120V NEMA & C19 outlets Highlights 20kVA / 20,000VA / 18,000W on-line double-conversion UPS; 0.9 power factor 208/120V or 240/120V 60Hz MODEL NUMBER: SU20KRT-1TF output; Economy mode option


    Original
    PDF 20kVA 208/120V 240/120V 000VA 240/120V SU20KRT-1TF 10kVA RS232

    Untitled

    Abstract: No abstract text available
    Text: Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: + 773 869 1234 E-mail: saleshelp@tripplite.com Model #: SU20KRT-1TF SmartOnline 20kVA On-Line Double-Conversion UPS, N+1, 14U Rack/Tower, 208/120V or 240/120V NEMA & C19 outlets Highlights


    Original
    PDF SU20KRT-1TF 20kVA 208/120V 240/120V 000VA 10kVA RS232

    GEFRAN

    Abstract: gefran 230 gefran 230 manual gefran 40 controller manual gefran controller automatic room power controller using scr gefran 230-si-a-1 transformer 230v to 5v 3VA star delta plc electronic eye automatic alarm
    Text: GTT 25 / 40 / 50 / 60 / 75 / 90 / 120A POWER SOLID STATE RELAYS WITH ANALOG CONTROL Main applications Main features • Plastics extrusion lines and injection moulding machines • Polymerization plant for synthetic fibre production • Rubber moulding machinery


    Original
    PDF 2004/108/CE 2006/95/CE UL508 E243386 GEFRAN gefran 230 gefran 230 manual gefran 40 controller manual gefran controller automatic room power controller using scr gefran 230-si-a-1 transformer 230v to 5v 3VA star delta plc electronic eye automatic alarm

    schematic diagram smps 500w

    Abstract: how to test computer smps with digital multimeter SIRIO CURRENT TRANSFORMER BLOCK DIAGRAM OF SMPS dsPIC33FJ16GS504 500w half bridge smps 25 volt ZVT full bridge pwm controller 100 ampere sirio DS70320B 500 Watt Phase Shifted ZVT Power Converter
    Text: SMPS AC/DC Reference Design User’s Guide 2008 Microchip Technology Inc. DS70320B Note the following details of the code protection feature on Microchip devices: • Microchip products meet the specification contained in their particular Microchip Data Sheet.


    Original
    PDF DS70320B DS70320B-page schematic diagram smps 500w how to test computer smps with digital multimeter SIRIO CURRENT TRANSFORMER BLOCK DIAGRAM OF SMPS dsPIC33FJ16GS504 500w half bridge smps 25 volt ZVT full bridge pwm controller 100 ampere sirio DS70320B 500 Watt Phase Shifted ZVT Power Converter

    WC1G

    Abstract: ct Potentiometer ground relay CURRENT TRANSFORMER Acess control SYSTEM
    Text: Ground Fault Relays Function: WILMAR Protective Relays – WC1G Series - Grounded TERMINAL STRIPS #6 - 32 SCREWS 3.8 3.0 WILMAR Ground Fault Detectors are designed to provide very sensitive Ground-Current protection for motor, equipment and personnel from damage or electrical


    Original
    PDF 120AC 220AC 230AC 380AC 400AC 460AC 480AC 575AC WC1G-120AC WC1G ct Potentiometer ground relay CURRENT TRANSFORMER Acess control SYSTEM

    1100nC

    Abstract: APT20M20LLL APT2X101S20J H100 2878 sgs
    Text: 2 3 2 2 3 3 1 1 4 1 Anti-Parallel 4 4 27 2 T- SO APT2X101S20J Parallel APT2X101S20J 200V 120A DUAL DIE ISOTOP PACKAGE HIGH VOLTAGE SCHOTTKY DIODE PRODUCT APPLICATIONS PRODUCT FEATURES PRODUCT BENEFITS • Rectifiers in Switchmode Power • • • • •


    Original
    PDF APT2X101S20J OT-227 1100nC APT20M20LLL APT2X101S20J H100 2878 sgs

    Untitled

    Abstract: No abstract text available
    Text: 1 2 TO -24 7 1 - Cathode 2 - Anode Back of Case - Cathode APT100S20B 200V 120A 1 2 HIGH VOLTAGE SCHOTTKY DIODE PRODUCT APPLICATIONS PRODUCT FEATURES PRODUCT BENEFITS • Parallel Diode • Ultrafast Recovery Times • Soft Recovery Characteristics • Low Losses


    Original
    PDF APT100S20B O-247

    Untitled

    Abstract: No abstract text available
    Text: tm mm âm ^ m mm Semiconductor Corporation T1/E1 Line Interface Features General Description • Provides Analog Transmission Line Interface for T1 and E1 Applications The CS6158 and CS6158A combine the complete ana­ log transmit and receive line interface for T1 or E1


    OCR Scan
    PDF CS6158 CS6158A 28-pin PE-65351 0553-0013-HC PE-65388 0553-0013-RC PE-65389 0553-0013-SC PE-65565