Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    THERMOCOUPLE TYPE K MATERIAL Search Results

    THERMOCOUPLE TYPE K MATERIAL Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DE6B3KJ151KA4BE01J Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    DE6B3KJ471KB4BE01J Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    DE6E3KJ152MN4A Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    DE6B3KJ101KA4BE01J Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    DE6B3KJ331KB4BE01J Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd

    THERMOCOUPLE TYPE K MATERIAL Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Untitled

    Abstract: No abstract text available
    Text: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    115Vac 230Vac PDF

    Untitled

    Abstract: No abstract text available
    Text: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    RS232 PDF

    Untitled

    Abstract: No abstract text available
    Text: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    115Vac 230Vac PDF

    Untitled

    Abstract: No abstract text available
    Text: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    115Vac 230Vac PDF

    Untitled

    Abstract: No abstract text available
    Text: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    115Vac 230Vac PDF

    NEDA 1604 6F22 006P

    Abstract: FLUKE 36 schematic diagram NEDA 1604 6F22 SAMA-CP45 80PK-2 6F22 9V calibration procedure for thermocouple Fluke Multimeter repair 741512 80PK-1
    Text: IF L U K E I — — — — Instruction Sheet 80TK Thermocouple Module INTRODUCTION Range Accuracy % of reading + degrees The Fluke 80TK is a thermocouple converter for use with any Ktype thermocouple and a digital multimeter (DMM). The 80TK accepts the output of any K-type thermocouple and converts it to


    OCR Scan
    PDF

    SUPER MCJ

    Abstract: No abstract text available
    Text: Thermocouple Input Super MCJ Analog Output, 1 mV per degree SMP or OST Connector SMCJ-J, SMCJ-K, SMCJ-T INSTRUCTION SHEET M-2813 Thermocouple-to-Analog Connector GENERAL DESCRIPTION This is a Thermocouple to Analog Connector. It converts a thermocouple input signal (Type J, K, or T) to a linear, compensated, amplified analog


    Original
    M-2813 SUPER MCJ PDF

    Untitled

    Abstract: No abstract text available
    Text: Low Noise Thermocouple Probes with High Temperature Standard Size Connectors SUPER OMEGACLAD XL THERMOCOUPLE WIRE MAXIMUM PERFORMANCE SHEATING & TM ELIMINATES HIGH TEMPERATURE DRIFT Available in Type K or Type N, Consult Sales for Specifications and Pricing.


    Original
    HGTQSS-116( HGTQSS-18( HGTQSS-316( HGTQSS-14( GS-GST-10, 75/pkg 321SSâ HGKQ321SS-316G-12 HGKQSS-316G-12, 304SS PDF

    PM 8058

    Abstract: AD594A TRANSDUCER PX 605 PM 8058 ic AD595AQ AD696
    Text: ANALOG DEVICES Monolithic Thermocouple Amplifiers with ColdJunction Compensation AD594*/AD595* FEATURES Pretrimmed for Type J AD594 or Type K (AD595) Thermocouples Can Be Used with Type T Thermocouple Inputs Low Impedance Voltage Output: 10mV/°C Built-in Ice Point Compensation


    OCR Scan
    AD594) AD595) AD594 /AD595* PM 8058 AD594A TRANSDUCER PX 605 PM 8058 ic AD595AQ AD696 PDF

    AD595

    Abstract: AD595 thermocouple NICR-NI thermocouple ice point compensation feedback thermocouple AD594 AD594A AD594AD AD594C AD595A AD595C
    Text: a Monolithic Thermocouple Amplifiers with Cold Junction Compensation AD594/AD595 FEATURES Pretrimmed for Type J AD594 or Type K (AD595) Thermocouples Can Be Used with Type T Thermocouple Inputs Low Impedance Voltage Output: 10 mV/؇C Built-In Ice Point Compensation


    Original
    AD594/AD595 AD594) AD595) O-116 AD595 AD595 thermocouple NICR-NI thermocouple ice point compensation feedback thermocouple AD594 AD594A AD594AD AD594C AD595A AD595C PDF

    NICR-NI thermocouple

    Abstract: nicr-ni temperature Thermocouple Type K material 6790 pf 27 AD595A 680 ohms resistor 5 watt datasheet AD595 thermocouple cold junction compensation of t type thermocouple AD595 C731e
    Text: a Monolithic Thermocouple Amplifiers with Cold Junction Compensation AD594*/AD595* FEATURES Pretrimmed for Type J AD594} or Type K (AD595 Thermocouples Can Be Used with Type T Thermocouple Inputs Low Impedance Voltage Output: 10 mV/؇C Built-In Ice Point Compensation


    Original
    AD594 /AD595* AD594} AD595) AD594/AD595 O-116 NICR-NI thermocouple nicr-ni temperature Thermocouple Type K material 6790 pf 27 AD595A 680 ohms resistor 5 watt datasheet AD595 thermocouple cold junction compensation of t type thermocouple AD595 C731e PDF

    iDRN-TC

    Abstract: Serial rs232 DB9 to RJ12 Serial DB9 to RJ12 DB25-RJ12 RJ12 to db25 RJ12 connector RJ12 to RS232 DB9-RJ12 RJ12 db9 RJ12
    Text: 2 START HERE iDRN-TC INPUT TYPE: Type J,K,T,E,R,S,B,N, J DIN THERMOCOUPLE INPUT General Description: The iDRN Series of DIN rail-mountable signal conditioners are available for Thermocouple, RTD, Strain, Process, AC Voltage, AC Current and Pulse/Totalizer input types.


    Original
    RS-232 c4643 D-75392 iDRN-TC Serial rs232 DB9 to RJ12 Serial DB9 to RJ12 DB25-RJ12 RJ12 to db25 RJ12 connector RJ12 to RS232 DB9-RJ12 RJ12 db9 RJ12 PDF

    Untitled

    Abstract: No abstract text available
    Text: Dual OMEGACLAD Thermocouple Wire SUPER ALSO AVAILABLE WITH 0.062 to 0.250 inch Diameter ® OMEGACLAD HIGH PURITY MAGNESIUM OXIDE MgO THERMOCOUPLE WIRE MAXIMUM PERFORMANCE SHEATHING ELIMINATES HIGH TEMPERATURE DRIFT For Type K Thermocouples only. Consult Sales for Specifications and Pricing.


    Original
    304-K-MO-125-DUAL-25, 321-K-MO-125-DUAL-25, PDF

    MAX31855

    Abstract: thermocouple MAX31855K
    Text: MAX31855 Cold-Junction Compensated Thermocouple-to-Digital Converter General Description The MAX31855 performs cold-junction compensation and digitizes the signal from a K-, J-, N-, T-, S-, R-, or E-type thermocouple. The data is output in a signed 14-bit, SPI-compatible, read-only format. This converter


    Original
    MAX31855 MAX31855 14-bit, thermocouple MAX31855K PDF

    MAX31855J

    Abstract: MAX31855 max31855k 200nC Thermocouple Type K MAX31855T
    Text: 19-5793; Rev 0; 3/11 MAX31855 Cold-Junction Compensated Thermocouple-to-Digital Converter General Description The MAX31855 performs cold-junction compensation and digitizes the signal from a K, J, N, T, or E type thermocouple. Contact the factory for S and R type thermocouples. The data is output in a signed 14-bit, SPI compatible, read-only format. This converter resolves


    Original
    MAX31855 14-bit, 1800NC -270NC, -200NC 700NC MAX31855J max31855k 200nC Thermocouple Type K MAX31855T PDF

    x0605

    Abstract: ANSI MC96.1 TYPE T AN701 EN50081-1 EN50082-1 ITS-90 MC96-1-82 monograph 175 process control system
    Text: SCM7B37 Isolated Thermocouple Input Modules FEATURES DESCRIPTION ● INTERFACES TO TYPE J, K, T, E, R, S, AND B THERMOCOUPLES SCM7B37 modules accept a single channel of input from Type J, K, T, E, R, S, or B thermocouples. The signal is filtered, isolated, amplified, and


    Original
    SCM7B37 SCM7B37 1500Vrms AN701 x0605 ANSI MC96.1 TYPE T EN50081-1 EN50082-1 ITS-90 MC96-1-82 monograph 175 process control system PDF

    KQSS-14G-12

    Abstract: No abstract text available
    Text: Quick Disconnect Thermocouples with Low Cost Standard Size SUPER Connector Molded to Probe Sheath OMEGACLAD XL THERMOCOUPLE WIRE MAXIMUM PERFORMANCE SHEATING ELIMINATES HIGH TEMPERATURE DRIFT Available in Type K or Type N, Consult Sales for Specifications and Pricing.


    Original
    304SS, 321SS EXPP-E-18S-( EXPP-E-20-( EXPP-E-24S-( EXFF-E-16-( EXFF-E-20-( EXFF-E-24-( EXFF-E-24-500, KQSS-14G-12 PDF

    Untitled

    Abstract: No abstract text available
    Text: 19-2241; Rev 0; 11/01 Cold-Junction-Compensated K-Thermocoupleto-Digital Converter 0°C to +128°C Features ♦ Cold-Junction Compensation The MAX6674 cold-junction-compensation thermocouple-to-digital converter performs cold-junction compensation and digitizes the signal from a type-K


    Original
    MAX6674 10-bit MAX6674 PDF

    Untitled

    Abstract: No abstract text available
    Text: Spring-Loaded Probes Industrial Process Styles SUPER OMEGACLAD XL THERMOCOUPLE WIRE MAXIMUM PERFORMANCE SHEATING ELIMINATES HIGH TEMPERATURE DRIFT Available in Type K or Type N, Consult Sales for Specifications and Pricing. Cut-away of NB2 style to show detail of


    Original
    300mm 0CPSS-316( -12-TBSL NB2-CPSS-14( NB2-CASS-316G-12-TBSL, PDF

    Untitled

    Abstract: No abstract text available
    Text: A Quick Reference Guide for High Temperature Measurement Super OMEGACLAD XL Probes These sheathed thermocouple probes have the highest temperature and stability ratings for type K and type N. Virtually any sheathed probe can be made with XL and achieve 1335°C


    Original
    PDF

    DIODE S5

    Abstract: MAX6675 circuit with thermocouple application 68HC11A8 MAX6675ISA thermocouple to frequency
    Text: 19-2235; Rev 1; 3/02 Cold-Junction-Compensated K-Thermocoupleto-Digital Converter 0°C to +1024°C Features The MAX6675 performs cold-junction compensation and digitizes the signal from a type-K thermocouple. The data is output in a 12-bit resolution, SPI -compatible, read-only format.


    Original
    MAX6675 12-bit 12-Bit, MAX6675 DIODE S5 circuit with thermocouple application 68HC11A8 MAX6675ISA thermocouple to frequency PDF

    Untitled

    Abstract: No abstract text available
    Text: Integral Handle Probes General Purpose Design SUPER MADE IN USA OMEGACLAD XL THERMOCOUPLE WIRE MAXIMUM PERFORMANCE SHEATING ELIMINATES HIGH TEMPERATURE DRIFT Available in Type K or Type N, Consult Sales for Specifications and Pricing. ߜ Heavy Duty ߜ 12" Probe Length Standard†


    Original
    HPS-CPSS-18U-12-SMP HPS-CPSS-18E-12-SMP HPS-CPSS-316G-12-SMP HPS-CPSS-316U-12-SMP HPS-CPSS-316E-12-SMP HPS-CPSS-14G-12-SMP HPS-CPSS-14U-12-SMP HPS-CPSS-14E-12-SMP HPS-ICIN-116G-12-SMP, PDF

    x0605

    Abstract: MC96-1-82 thermistor ntc 30k monograph 175 ANSI MC96.1 TYPE T AN505 AN701 EN50081-1 EN50082-1 Thermocouple Type K linearization
    Text: SCM7B47 Isolated Linearized Thermocouple Input Modules FEATURES DESCRIPTION ● INTERFACES TO TYPES J, K, T, E, R, S, B AND N THERMOCOUPLES SCM7B47 modules accept a single channel of input from Type J, K, T, E, R, S, B, or N thermocouples. The signal is filtered, isolated, amplified, linearized, and converted


    Original
    SCM7B47 SCM7B47 AN505. 1500Vr x0605 MC96-1-82 thermistor ntc 30k monograph 175 ANSI MC96.1 TYPE T AN505 AN701 EN50081-1 EN50082-1 Thermocouple Type K linearization PDF