Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    THERMOCOUPLE TYPE J Search Results

    THERMOCOUPLE TYPE J Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CO-059FTYPEMM-050 Amphenol Cables on Demand Amphenol CO-059FTYPEMM-050 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 50 ft Datasheet
    CO-059FTYPEMM-006 Amphenol Cables on Demand Amphenol CO-059FTYPEMM-006 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 6 ft Datasheet
    CO-059FTYPEMM-010 Amphenol Cables on Demand Amphenol CO-059FTYPEMM-010 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 10 ft Datasheet
    CO-059FTYPEMM-025 Amphenol Cables on Demand Amphenol CO-059FTYPEMM-025 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 25 ft Datasheet
    CO-059FTYPEMM-003 Amphenol Cables on Demand Amphenol CO-059FTYPEMM-003 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 3 ft Datasheet

    THERMOCOUPLE TYPE J Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    type j thermocouple

    Abstract: type k thermocouple Calex C277C 277c
    Text: Model 8611 Type J and 8612 Type K Thermocouple to Frequency Converters Features Description n Linearized Frequency n Cold Junction Compensation n 0 to 500°C or 0 to 1000°C Type J Thermocouple n 0 to 1250°C Type K Thermocouple Model 8611. This type J thermocouple to frequency converter


    Original
    PDF

    AC1361

    Abstract: 5B47-K-05 accuracy of b type thermocouple Thermocouple Type K sensor Amplifier k thermocouple 5B47-T-07 Cold Junction Compensation cold junction compensation of t type thermocouple Thermocouple Type T sensor test 5B47
    Text: Isolated, Linearized Thermocouple Input 5B47 FEATURES Isolated Thermocouple Input. Amplifies, Protects, Filters, and Isolates Thermocouple Input Works with J, K, T, E, R, S, and B-type thermocouple. Generates aisolated and protected precision output of 0 to


    Original
    PDF D05102-0-9/04 AC1361 5B47-K-05 accuracy of b type thermocouple Thermocouple Type K sensor Amplifier k thermocouple 5B47-T-07 Cold Junction Compensation cold junction compensation of t type thermocouple Thermocouple Type T sensor test 5B47

    Thermocouple Type K material

    Abstract: thermocouple connectors IM-K-SSPF j type thermocouple sensor Thermocouple Type K sensor Thermocouple circuit type t IM-K-PCB PCB MOUNTING CONNECTORS IM-CU-MQ R type thermocouple wire
    Text: THERMOCOUPLE CONNECTORS & ACCESSORIES THERMOCOUPLE CONNECTORS & ACCESSORIES MINIATURE SOCKET, TWIN CONTACT Types J, K, T, N, E, R/S & COPPER THERMOCOUPLE CONNECTORS MINIATURE, RECTANGULAR, FASCIA SOCKETS Types J, K, T, N, E, R/S & COPPER Type J Type K Type T


    Original
    PDF

    ANSI MC96.1

    Abstract: ANSI MC96.1-1982 Thermocouple color constantan Thermocouple Type L chromel ANSI MC96.1 TYPE E ANSI MC96.1 TYPE T T-29-520 ANSI MC96.1 TYPE E THERMOCOUPLE
    Text: INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.53 UL Instrumentation Cable Thermocouple Extension Cables and Thermocouple Wire — Overview Construction Thermocouple Extension Cable Conductor material determined by the thermocouple extension wire type. FEP


    Original
    PDF 1-800-BELDEN-1 ANSI MC96.1 ANSI MC96.1-1982 Thermocouple color constantan Thermocouple Type L chromel ANSI MC96.1 TYPE E ANSI MC96.1 TYPE T T-29-520 ANSI MC96.1 TYPE E THERMOCOUPLE

    Calex

    Abstract: type j thermocouple C277C 277c
    Text: Model 8611 Type J and 8612 Type K Thermocouple to Frequency Converters Features Description n Linearized Frequency n Cold Junction Compensation n 0 to 500°C or 0 to 1000°C Type J Thermocouple n 0 to 1250°C Type K Thermocouple n Isolated Input to Output


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Strip Chart Recorders With Thermocouple and Millivolt Inputs Rugged Metal Case for Panel or Bench Operation MADE IN USA ߜ Compact 100 mm 4" Chart Width ߜ Type J Thermocouple Input Switchable Between Thermocouple or Millivolt Input ߜ Set Thermocouple Zero


    Original
    PDF RD-145 RD-146 RD146-JC-MIN,

    optocoupler thermocouple

    Abstract: calex 8511 Calex 8511
    Text: Model 8511 Type J and 8512 Type K Thermocouple to Frequency Converters Features Description n Linearized Frequency 10 Hz per degree Centigrade n Cold Junction Compensation n 0 to 500° Type J / K Thermocouple n Isolated Input to Output These thermocouple to frequency converters are designed to


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: EL-WiFi-TC WiFi Thermocouple Data Logging Sensor FEATURES • Temperature data logging sensor with K type thermocouple probe and integrated display • Supports J,K,N,T type thermocouple probes • Easy sensor set-up using the free PC software application downloadable from www.


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    PDF 115Vac 230Vac

    Untitled

    Abstract: No abstract text available
    Text: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    PDF RS232

    Untitled

    Abstract: No abstract text available
    Text: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    PDF 115Vac 230Vac

    Cold Junction Compensation

    Abstract: k thermocouple amplification circuit diagram lvdt thermocouple 3B37 3B47 3B47-E-08 3B47-J-01 3B47-J-02 3B47-J-03 3B47-K-04
    Text: Isolated, Linearized, Thermocouple Input 3B47 FEATURES Interfaces, amplifies, filters, isolates, & linearizes analog input voltages from a J, K, T, E, R, S or B-type thermocouple Thermocouple input signal is internally linearized High accuracy internal cold junction compensation.


    Original
    PDF D05162-0-9/04 Cold Junction Compensation k thermocouple amplification circuit diagram lvdt thermocouple 3B37 3B47 3B47-E-08 3B47-J-01 3B47-J-02 3B47-J-03 3B47-K-04

    Untitled

    Abstract: No abstract text available
    Text: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    PDF 115Vac 230Vac

    Untitled

    Abstract: No abstract text available
    Text: Isolated, Linearized, Thermocouple Input 3B47 FEATURES Interfaces, amplifies, filters, isolates, & linearizes analog input voltages from a J, K, T, E, R, S or B-type thermocouple Thermocouple input signal is internally linearized High accuracy internal cold junction compensation.


    Original
    PDF D05162-0-9/04

    Untitled

    Abstract: No abstract text available
    Text: Step 11. Enter to the Thermocouple Type Input Submenu Press d to display flashing, previously selected Thermocouple type. Step 12. Scroll through available selection of TC types Press b to sequence thru flashing Thermocouple types, select k -for type "K" CHROMEGA /ALOMEGA®


    Original
    PDF 115Vac 230Vac

    thermocouple type-k

    Abstract: No abstract text available
    Text: 80PK-11 English Instruction Sheet Page 1 80PK-11 Type-K Velcro Thermocouple Temperature Probe Instruction Sheet Introduction The 80PK-11 is a Type-K Velcro Thermocouple Temperature Probe designed for HVAC temperature measuring applications. The 20 inch PVC cable terminates with a Type-K thermocouple


    Original
    PDF 80PK-11 80PK-11 thermocouple type-k

    SUPER MCJ

    Abstract: No abstract text available
    Text: Thermocouple Input Super MCJ Analog Output, 1 mV per degree SMP or OST Connector SMCJ-J, SMCJ-K, SMCJ-T INSTRUCTION SHEET M-2813 Thermocouple-to-Analog Connector GENERAL DESCRIPTION This is a Thermocouple to Analog Connector. It converts a thermocouple input signal (Type J, K, or T) to a linear, compensated, amplified analog


    Original
    PDF M-2813 SUPER MCJ

    527-01

    Abstract: No abstract text available
    Text: + – Revised Thermocouple Reference Tables J TYPE Reference Tables N.I.S.T. Monograph 175 Revised to ITS-90 °C -10 -9 -8 -7 -6 -5 -4 Thermocouple Grade Iron vs. Copper-Nickel + – Extension Grade MAXIMUM TEMPERATURE RANGE Thermocouple Grade 32 to 1382°F


    Original
    PDF ITS-90 Z-245 527-01

    30AWG 1C

    Abstract: TCP6-K12 thermocouple connectors TCW100-K Thermocouple Type K k type thermocouple cable 537C 356f
    Text: Thermocouple Probes and Wires All probes on this page have standard subminiature thermocouple connectors and plug directly into HOBO Thermocouple Family loggers. The connectors are color-coded for type J black , K (yellow), and T (blue) thermocouples according to the ANSI standard. Note


    Original
    PDF 30-AWG TCP6-K12 24-AWG TCW100-J TCW100-K TCW100-T 1-800-LOGGERS 30AWG 1C TCP6-K12 thermocouple connectors TCW100-K Thermocouple Type K k type thermocouple cable 537C 356f

    8920-500-DC

    Abstract: ma 8920 Cold Junction Compensation Thermocouple K TYPE CIRCUIT m91 Series Amplifier type K thermocouple 0-10V 4.....20MA Isolated 4-20ma UL-94V-1 cold junction
    Text: Models 8920, 8921 Type J & K Isolated Thermocouple to Voltage The 8900 Series offers a low cost TC thermocouple and RTD signal conditioning solution for applications that require a 0-10V output signal. All models isolate and linearize. The thermocouple conditioners also have cold junction


    Original
    PDF 24VDC. term700 UL-94V-1) 14-M91, 213-M1987 8920-500-DC ma 8920 Cold Junction Compensation Thermocouple K TYPE CIRCUIT m91 Series Amplifier type K thermocouple 0-10V 4.....20MA Isolated 4-20ma UL-94V-1 cold junction

    Thermocouple K bead type

    Abstract: FLUKE 43B 80PK-25 80T-150U 80PK-1 FLUKE 8846A thermocouple type-k 80PK-9 80PK-22 Thermocouple color
    Text: Temperature Accessories Contact Probes 80PK-22 SureGrip Immersion Probe • Type-K thermocouple for use in liquids and gels • Measurement range: -40 to 1090°C DMM Probes 80PK-1 and 80PJ-1 Bead Probe 80AK Thermocouple Adapter • 80PK-1: Type-K thermocouple for


    Original
    PDF 80PK-22 80PK-1 80PJ-1 80PK-1: 80PK-24 741B/743B/744 845A/8846A 80PK-1 80PK-27 Thermocouple K bead type FLUKE 43B 80PK-25 80T-150U FLUKE 8846A thermocouple type-k 80PK-9 Thermocouple color

    k thermocouple amplification circuit diagram

    Abstract: AD594 AD595 AD594CD drawn pin configuration of ic 7402 J type thermocouple AD594A AD594AD AD594C AD595A
    Text: a Monolithic Thermocouple Amplifiers with Cold Junction Compensation AD594/AD595 FEATURES Pretrimmed for Type J AD594 or Type K (AD595) Thermocouples Can Be Used with Type T Thermocouple Inputs Low Impedance Voltage Output: 10 mV/؇C Built-In Ice Point Compensation


    Original
    PDF AD594/AD595 AD594) AD595) O-116 k thermocouple amplification circuit diagram AD594 AD595 AD594CD drawn pin configuration of ic 7402 J type thermocouple AD594A AD594AD AD594C AD595A

    J type thermocouple 0-400c

    Abstract: appa 76 40468 10F26 0200C ki *938 0-600C
    Text: Thermocouple Measurement Converter to 4/20mA Diagrams Loop resistance Reference Table for Type K Thermocouple Loop operating conditions Ordering Data for TS 35 for TS 32 L j Temperature of Thermocouple Technical Data DC -200 -5891 10 20 -100 -3553 4095 8137


    OCR Scan
    PDF 4/20mA 24VDC J type thermocouple 0-400c appa 76 40468 10F26 0200C ki *938 0-600C

    PM 8058

    Abstract: AD594A TRANSDUCER PX 605 PM 8058 ic AD595AQ AD696
    Text: ANALOG DEVICES Monolithic Thermocouple Amplifiers with ColdJunction Compensation AD594*/AD595* FEATURES Pretrimmed for Type J AD594 or Type K (AD595) Thermocouples Can Be Used with Type T Thermocouple Inputs Low Impedance Voltage Output: 10mV/°C Built-in Ice Point Compensation


    OCR Scan
    PDF AD594) AD595) AD594 /AD595* PM 8058 AD594A TRANSDUCER PX 605 PM 8058 ic AD595AQ AD696