Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TESYS SCHEMES Search Results

    TESYS SCHEMES Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    LRD schneider relay

    Abstract: LRD-340 L schneider LRD 08 schneider LRD 365 LRD 15 Schneider NSX 400 F LRD 350 LA7 D09 overload schneider thermal overload relay lrd 32 LRD-365
    Text: TeSys protection components Presentation, description 3-pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively long starting times,


    Original
    PDF D3064 DP200 DE200 D35pp D1020 M10x1 LRD schneider relay LRD-340 L schneider LRD 08 schneider LRD 365 LRD 15 Schneider NSX 400 F LRD 350 LA7 D09 overload schneider thermal overload relay lrd 32 LRD-365

    automatic motor for reverse and forward

    Abstract: altistart TESYS U lu2b tesys aSYNCHRONOUS MOTOR WIRING tesys reverse altistart 3 LUA1C20 tesys control units
    Text: Schemes 1 Soft starters for asynchronous motors Altistart U01 and TeSys model U For 0.75 to 15 kW motors ATSU 01N2ppLT soft start/soft stop units 5/L3 3/L2 1/L1 5/L3 Power wiring with reversing unit 3/L2 1/L1 Power wiring – QF1 – QF1 TeSys model U CU TeSys


    Original
    PDF 01N2ppLT 01N2ppLT 60553-EN automatic motor for reverse and forward altistart TESYS U lu2b tesys aSYNCHRONOUS MOTOR WIRING tesys reverse altistart 3 LUA1C20 tesys control units

    LC1 D09 10

    Abstract: LC1D40A tesys d contactors LC1 D12 P7 D65A LC1 D09 BD LC2-D12 LC1-D40A LC1 D38 LC2-D09
    Text: TeSys contactors References 526172 TeSys D, 3-pole reversing contactors for motor control up to 75 kW at 400 V, in category AC-3 Horizontally mounted, pre-assembled 3-pole reversing contactors for connection by screw clamp terminals Pre-wired power connections.


    Original
    PDF D12pp kW/400 24503-EN LC1 D09 10 LC1D40A tesys d contactors LC1 D12 P7 D65A LC1 D09 BD LC2-D12 LC1-D40A LC1 D38 LC2-D09

    soft start motor control diagram

    Abstract: altistart wiring diagram soft start soft starter wiring altistart 3 tesys soft start motor diagram relay tesys aSYNCHRONOUS MOTOR WIRING line contactor
    Text: Presentation 1 Soft starters for asynchronous motors 1 Altistart U01 and TeSys model U Presentation The Altistart U01 is a soft start/soft stop unit for asynchronous motors. It is designed primarily for combinations with TeSys model U controller-starters.


    Original
    PDF DF563960 01N2ppLT 60550-EN soft start motor control diagram altistart wiring diagram soft start soft starter wiring altistart 3 tesys soft start motor diagram relay tesys aSYNCHRONOUS MOTOR WIRING line contactor

    LC1 D093

    Abstract: LC1 D253 LC1 D323 tesys d contactors LC1 D123 LC1DT60A LC1 D32 wiring LC1-D093 LC1-D323 LC1-D123
    Text: TeSys contactors Characteristics TeSys D contactors Contactor type LC1 D09…D18 DT20 and DT25 D25…D38 DT32 and DT40 D40A…D65A DT60A and DT80A D80…D95 D115 and D150 Environment Rated insulation voltage Ui Rated impulse withstand voltage (Uimp) Conforming to IEC 60947-4-1,


    Original
    PDF DT60A DT80A DC-13 24505-EN LC1 D093 LC1 D253 LC1 D323 tesys d contactors LC1 D123 LC1DT60A LC1 D32 wiring LC1-D093 LC1-D323 LC1-D123

    lc1-d09

    Abstract: LC1 D32 wiring LC1 DT40 LC1 D18 P7 LC1DT60A LC1 D12 P7 LC1-D80 LC1-D12 LC1 D09 10 LC1 D95 BD
    Text: TeSys contactors References TeSys D contactors for motor control up to 75 kW at 400 V, in category AC-3 810356 For connection by screw clamp terminals and lugs 3-pole contactors Standard power ratings of 3-phase motors 50-60 Hz in category AC-3 θ y 60 °C


    Original
    PDF D09pp D3553 D3555 D3557 D3559 D3561 D3563 lc1-d09 LC1 D32 wiring LC1 DT40 LC1 D18 P7 LC1DT60A LC1 D12 P7 LC1-D80 LC1-D12 LC1 D09 10 LC1 D95 BD

    Schneider NS 800

    Abstract: LUA1C110 LB920 LUCA 1XBL schneider thermal overload relay schneider GV2 LA9LB920 Schneider Electric lub LUB320 schneider motor starter
    Text: TeSys Model U Selection guide Starter-controllers Function performed Function not performed Selectable overload class Detection of overtorque, no-load running, long starting times Earth fault protection equipment protection only Protection against phase imbalance


    Original
    PDF AP00r AP11r AP12r Schneider NS 800 LUA1C110 LB920 LUCA 1XBL schneider thermal overload relay schneider GV2 LA9LB920 Schneider Electric lub LUB320 schneider motor starter

    telemecanique LC1 f400

    Abstract: NS630H NS400H NS250H c1001 merlin gerin NS80H Telemecanique LC1 EC 19 lc1 f265 telemecanique magnetic contactor NS160H
    Text: Selection guide TeSys Model U Starter-controllers Control units Function characteristics Control units Standard LUCA Thermal overload protection Overcurrent protection Advanced LUCB LUCC LUCD 14.2 x the setting current Short-circuit protection Protection against phase loss


    Original
    PDF AC-15 DC-13 telemecanique LC1 f400 NS630H NS400H NS250H c1001 merlin gerin NS80H Telemecanique LC1 EC 19 lc1 f265 telemecanique magnetic contactor NS160H

    LC1-DT40

    Abstract: LC1D80004 LADN10 Schneider LC1DT20 LC1-D65 LADS2 LC1-D38 WIRING LC1-D09 lad-s2 LC1-D80004
    Text: References TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters For 3-pole motor reversing contactors using 2 identical contactors 810373 Contactors with screw clamp terminals or connectors


    Original
    PDF LC1-D09. LA9-D6569 LA9-D4002 LA9-D8069 LA9-D8002 LA9-D92 LA9-D93 LC1-DT40 LC1D80004 LADN10 Schneider LC1DT20 LC1-D65 LADS2 LC1-D38 WIRING LC1-D09 lad-s2 LC1-D80004

    LC1-D09

    Abstract: LC1 D09 10 LC1-D18 LC1 D12 10 LC1 contactor LC1 D38 LAD93217 LC1-D80 LC1-D32 contactor d09
    Text: TeSys contactors References 537729 Component parts for assembling reversing contactors for motor control, low-speed/high-speed starters and star-delta starters For 3-pole reversing contactors for motor control Contactors with screw clamp terminals or connectors. Horizontally mounted, assembled by customer


    Original
    PDF

    LC1-D150

    Abstract: bs 5424 schneider LC1-D09 schneider LC1-D09 LC1-D40 LC1 Schneider VDE 0660 BS 5424 lad6k10 LA4 dfb IEC 60947-5-1
    Text: 24505 Page 62 Thursday, October 25, 2001 5:44 PM Characteristics TeSys contactors Model d Farnell Codes ; 4231855 - 4232148 Type of contactor LC1LC1D09…D18 D25…D38 DT20 & DT25 DT32…DT6 LC1D40 1000 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage Ui


    Original
    PDF LC1LC1D09. LC1D40 LC1D50. LC1-D115 LC1-D150 LC1-D09. LC1-D80 LC1-D40. LC1-D150 bs 5424 schneider LC1-D09 schneider LC1-D09 LC1-D40 LC1 Schneider VDE 0660 BS 5424 lad6k10 LA4 dfb IEC 60947-5-1

    LT4706M7S

    Abstract: LR97D LR97 lad 7b106 LR97D015M7 lt4706m7a LC1b D07M7 D38F7 D015M7
    Text: TeSys protection components Presentation, description Electronic over current relays Presentation 109487 LR97 D and LT47 electronic over current relays have been developed to satisfy machine protection requirements. These relays have definite time characteristics: current threshold and time based function.


    Original
    PDF secT47 24517-EN LT4706M7S LR97D LR97 lad 7b106 LR97D015M7 lt4706m7a LC1b D07M7 D38F7 D015M7

    LC1-D09

    Abstract: LC1-D150 lad6k10 schneider LC1-D09 bs 5424 schneider schneider LC1-D LC1 Schneider LC1-D115 LC1-D09 diagram LA6DK10
    Text: Characteristics TeSys contactors Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32…DT60 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage Ui Rated impulse withstand voltage (Uimp) 2 Conforming to EN 60947-4-1,


    Original
    PDF LC1LC1LC1D09. LC1D50. LC1-D115 LC1-D150 LC1-D09. LC1-D80 LC1-D40. LC1-D09 LC1-D150 lad6k10 schneider LC1-D09 bs 5424 schneider schneider LC1-D LC1 Schneider LC1-D115 LC1-D09 diagram LA6DK10

    schneider LRD 08

    Abstract: LRD schneider relay LC1-D65 LC1-D50 Schneider Electric LRD 06 LR9-D5369 LC1-D09 schneider overload relay schneider LC1-D09 LRD-21
    Text: 24516 Page 108 Friday, October 26, 2001 9:32 AM Description, characteristics TeSys protection components 3-pole thermal overload relays, model d Description Model d 3-pole thermal overload relays are designed to protect a.c. circuits and motors against overloads, phase failure,


    Original
    PDF LRD-01. LRD-3322. LR9-D67 LR9-D69 schneider LRD 08 LRD schneider relay LC1-D65 LC1-D50 Schneider Electric LRD 06 LR9-D5369 LC1-D09 schneider overload relay schneider LC1-D09 LRD-21

    LC2 contactor

    Abstract: LC2-D12 LC2-D09 contactor d09 pp d115 D09P7V D115 D150 LC2-D40 LC2-D150
    Text: References TeSys contactors 5 5 Reversing contactors for motor control up to 75 kW at 400 V, in category AC-3 Horizontally mounted, pre-assembled Control circuit: a.c., d.c. or low consumption 810369 3-pole reversing contactors for connection by screw clamp terminals or connectors


    Original
    PDF 24503-EN LC2 contactor LC2-D12 LC2-D09 contactor d09 pp d115 D09P7V D115 D150 LC2-D40 LC2-D150

    schneider GV2

    Abstract: schneider GV2RT 150 KW motor types GV2, GV3 and GV7 TeSys GV2L schneider overload gv2 GV2ME 4.6 KW motor schneider GV2ME circuit-breakers
    Text: Chapter 3: Contents Schneider Electric TeSys motor circuit-breakers Selection guide: Thermal-magnetic motor circuit-breakers pages 3/2 and 3/3 Selection guide: Magnetic motor circuit-breakers pages 3/4 and 3/5 Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7


    Original
    PDF

    bva04

    Abstract: D656 tesys d contactors K065 D406 D806 M7230 IEC 60439-1 start return ac motors LE4-D09
    Text: TeSys enclosed starters Characteristics, references 2 2 D.O.L. starters for motor control 1 2.2 to 45 kW, with isolating device Characteristics Conforming to standards IEC 60947-4-1 and IEC 60439-1, VDE 0660-102, EN 60947 Ambient air temperature IP 659: LEp K


    Original
    PDF D09907 D09F7A04. 24103-EN bva04 D656 tesys d contactors K065 D406 D806 M7230 IEC 60439-1 start return ac motors LE4-D09

    LA2 DS2

    Abstract: star-delta starting motors 160 kw star delta starter current starter voltage 75 kw tesys d contactors D806 star delta starter LE3 LA2Ds2 contactor d09 IEC 60439-1
    Text: Characteristics, references TeSys enclosed starters 2 2 Star-delta starters 1 7.5 to 75 kW with isolating device Characteristics Conforming to standards IEC 60947-4-1 and IEC 60439-1, VDE 0660-102, EN 60947 Degree of protection conforming to IEC 60529 Ambient air temperature


    Original
    PDF D12ppA04 D12ppA05 D09F7A04. 24108-EN LA2 DS2 star-delta starting motors 160 kw star delta starter current starter voltage 75 kw tesys d contactors D806 star delta starter LE3 LA2Ds2 contactor d09 IEC 60439-1

    schneider GV2ME

    Abstract: TeSys GV2L LRD-33 GV7-RE220 LRD schneider relay LRD33 GV2-ME07 GV2-L32 LRD-33 tripping curve GV7-RS100
    Text: Curves TeSys protection components Thermal-magnetic motor circuit-breakers types GV2-ME and GV2-P Thermal-magnetic tripping curves for GV2-ME and GV2-P Average operating time at 20 °C according to multiples of the setting current Time s 10 000 1000 100


    Original
    PDF

    LRD 07

    Abstract: LR2 D* thermal overload relay LRD-08 overload relay LRD 03 LRD 3355 lrd16 LRD 10 LRD1516 lrd -08 LRD-08 thermal overload relay
    Text: References 6 TeSys protection components 6 3-pole thermal overload relays, model d 810464 Differential thermal overload relays for use with fuses b Compensated relays with manual or automatic reset, b with relay trip indicator, b for a.c. or d.c. Relay setting range A


    Original
    PDF 24514-EN LRD 07 LR2 D* thermal overload relay LRD-08 overload relay LRD 03 LRD 3355 lrd16 LRD 10 LRD1516 lrd -08 LRD-08 thermal overload relay

    LC1-D123

    Abstract: LC1-D093 LC1-D323 LC1-D183 LA6-DK20 LC1-D253 LAD6K10 LC1-D150 LAD-4RC LA6DK10
    Text: Characteristics TeSys contactors 5 Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32 & DT40 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage Ui 2 Rated impulse withstand voltage (Uimp) Conforming to IEC EN 947-4-1,


    Original
    PDF LC1LC1LC1D09. LC1D50. LC1-D115 LC1-D150 LC1-D09. LC1-D80 LC1-D40. LC1-D123 LC1-D093 LC1-D323 LC1-D183 LA6-DK20 LC1-D253 LAD6K10 LC1-D150 LAD-4RC LA6DK10

    CONTACTOR LP4 K

    Abstract: LC1 contactor LP1 contactor LC7 CONTACTOR LC1 contactor COIL POWER k0601 LP4 contactor LC-7 K1210 24407
    Text: References 5 TeSys contactors 5 Contactors for motor control, 6 to 16 A in category AC-3 and 6 to 12 A in category AC-4 Control circuit: a.c. 106151_1 Contactor selection according to utilisation category, see pages 24565/2 to 24565/5 and 24566/2 to 24566/5.


    Original
    PDF K0910pp 24402-EN CONTACTOR LP4 K LC1 contactor LP1 contactor LC7 CONTACTOR LC1 contactor COIL POWER k0601 LP4 contactor LC-7 K1210 24407

    LA9LB920

    Abstract: SCHNEIDER MOTOR PROTECTION circuit breaker IEC 439-1 LA9-LB920 GV3-ME40 GK3EF40 GV3-A03 GV3A01 schneider GV2ME GV3-A01
    Text: Characteristics TeSys protection components Thermal-magnetic motor circuit-breakers Environment Circuit-breaker type GV2-ME Conforming to standards EN 60947-1, 947-2, 947-4-1, EN 60204, UL 508, CSA C22-2 n° 14, NF C 63-650, 63-120, 79-130, VDE 0113, 0660


    Original
    PDF C22-2 GV2-M/01: LA9-LB920 LA9LB920 SCHNEIDER MOTOR PROTECTION circuit breaker IEC 439-1 LA9-LB920 GV3-ME40 GK3EF40 GV3-A03 GV3A01 schneider GV2ME GV3-A01

    lad6k10

    Abstract: LC1 D25004 LC1 d12008 contactor LC1 D25008 LC1-D65004 LC1D65004 LP1D12004 schneider electric LC1 D25 LC1 d40008 LC1 D093
    Text: Dimensions TeSys contactors Model d contactors Control circuit: a.c. LC1-D09…D18 3-pole LC1-D25…D38 (3-pole) LC1-DT20…DT60 (4-pole) 44 Minimum electrical clearance 44 Minimum electrical clearance LA4 b b b1 b1 LA4 D093… D183 99 107 123 (1) 132 (1)


    Original
    PDF LC1-D09. LC1-D25. LC1-DT20. LC2-DT20. 21/NC 13/NO lad6k10 LC1 D25004 LC1 d12008 contactor LC1 D25008 LC1-D65004 LC1D65004 LP1D12004 schneider electric LC1 D25 LC1 d40008 LC1 D093