Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TESYS CONTACTORS Search Results

    TESYS CONTACTORS Result Highlights (1)

    Part ECAD Model Manufacturer Description Download Buy
    DRV3946QPWPRQ1 Texas Instruments Automotive 12-V contactor driver with current sensing and regulation 28-HTSSOP -40 to 125 Visit Texas Instruments

    TESYS CONTACTORS Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    LRD schneider relay

    Abstract: LRD-340 L schneider LRD 08 schneider LRD 365 LRD 15 Schneider NSX 400 F LRD 350 LA7 D09 overload schneider thermal overload relay lrd 32 LRD-365
    Text: TeSys protection components Presentation, description 3-pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively long starting times,


    Original
    PDF D3064 DP200 DE200 D35pp D1020 M10x1 LRD schneider relay LRD-340 L schneider LRD 08 schneider LRD 365 LRD 15 Schneider NSX 400 F LRD 350 LA7 D09 overload schneider thermal overload relay lrd 32 LRD-365

    LC1 D09 10

    Abstract: LC1D40A tesys d contactors LC1 D12 P7 D65A LC1 D09 BD LC2-D12 LC1-D40A LC1 D38 LC2-D09
    Text: TeSys contactors References 526172 TeSys D, 3-pole reversing contactors for motor control up to 75 kW at 400 V, in category AC-3 Horizontally mounted, pre-assembled 3-pole reversing contactors for connection by screw clamp terminals Pre-wired power connections.


    Original
    PDF D12pp kW/400 24503-EN LC1 D09 10 LC1D40A tesys d contactors LC1 D12 P7 D65A LC1 D09 BD LC2-D12 LC1-D40A LC1 D38 LC2-D09

    LC1 D093

    Abstract: LC1 D253 LC1 D323 tesys d contactors LC1 D123 LC1DT60A LC1 D32 wiring LC1-D093 LC1-D323 LC1-D123
    Text: TeSys contactors Characteristics TeSys D contactors Contactor type LC1 D09…D18 DT20 and DT25 D25…D38 DT32 and DT40 D40A…D65A DT60A and DT80A D80…D95 D115 and D150 Environment Rated insulation voltage Ui Rated impulse withstand voltage (Uimp) Conforming to IEC 60947-4-1,


    Original
    PDF DT60A DT80A DC-13 24505-EN LC1 D093 LC1 D253 LC1 D323 tesys d contactors LC1 D123 LC1DT60A LC1 D32 wiring LC1-D093 LC1-D323 LC1-D123

    LC1-D25

    Abstract: LC1-D09 CONTACTOR LC1-D115 LAD-7305 LC1-D115 lad 7b106 LC1-D25 contactor LC1-D25 wiring LC1-D09 01 LA7D3058
    Text: References 6 TeSys protection components 3-pole thermal overload relays, model d 24515-EN_Ver7.0.fm/2 6 References continued 6 TeSys protection components 6 3-pole thermal overload relays, model d Accessories Accessories (to be ordered separately) 533574


    Original
    PDF 24515-EN DP200) LC1-D25 LC1-D09 CONTACTOR LC1-D115 LAD-7305 LC1-D115 lad 7b106 LC1-D25 contactor LC1-D25 wiring LC1-D09 01 LA7D3058

    lc1-d09

    Abstract: LC1 D32 wiring LC1 DT40 LC1 D18 P7 LC1DT60A LC1 D12 P7 LC1-D80 LC1-D12 LC1 D09 10 LC1 D95 BD
    Text: TeSys contactors References TeSys D contactors for motor control up to 75 kW at 400 V, in category AC-3 810356 For connection by screw clamp terminals and lugs 3-pole contactors Standard power ratings of 3-phase motors 50-60 Hz in category AC-3 θ y 60 °C


    Original
    PDF D09pp D3553 D3555 D3557 D3559 D3561 D3563 lc1-d09 LC1 D32 wiring LC1 DT40 LC1 D18 P7 LC1DT60A LC1 D12 P7 LC1-D80 LC1-D12 LC1 D09 10 LC1 D95 BD

    LA6DK10

    Abstract: lad6k10 LA1-DX20 LADR4 LA6-DK10 LADC223 LADN11 LAD-6K10 schneider CAD-32 CA2SK
    Text: IEC Type Industrial Control Relays TeSys D-Line, K-Line, and SK-Line Class 8501 CONTENTS Schneider Electric Brands Description Page Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2


    Original
    PDF 1-888-SquareD 8501CT0101 LA6DK10 lad6k10 LA1-DX20 LADR4 LA6-DK10 LADC223 LADN11 LAD-6K10 schneider CAD-32 CA2SK

    LAD9R1V

    Abstract: Lp1k0910bd LC1K0910B7 LR2K0316 LRD350 LP1K0610BD LC1D09BL LRD08 tesys d contactors LRD10
    Text: 1390-2012.qxp:QuarkCatalogTempNew 9/12/12 10:06 AM Page 1390 PASSIVE & ACTIVE OPTOELECTRONICS MOTOR CONTROL, DRIVES & CONTACTORS POWER ENCLOSURES INTERCONNECT TEST & MEASUREMENT 15 Contactors and Overload Relays Non-Reversing Mini-Contactors and Overload Relays — TeSys K


    Original
    PDF LC1K0610B7 LC1K0610G7 LC1K0910B7 LC1K0910G7 LC1K1210B7 LC1K1210G7 smLRD340 LR3D340 LR3D350 LRD350 LAD9R1V Lp1k0910bd LR2K0316 LP1K0610BD LC1D09BL LRD08 tesys d contactors LRD10

    LC1-DT40

    Abstract: LC1D80004 LADN10 Schneider LC1DT20 LC1-D65 LADS2 LC1-D38 WIRING LC1-D09 lad-s2 LC1-D80004
    Text: References TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters For 3-pole motor reversing contactors using 2 identical contactors 810373 Contactors with screw clamp terminals or connectors


    Original
    PDF LC1-D09. LA9-D6569 LA9-D4002 LA9-D8069 LA9-D8002 LA9-D92 LA9-D93 LC1-DT40 LC1D80004 LADN10 Schneider LC1DT20 LC1-D65 LADS2 LC1-D38 WIRING LC1-D09 lad-s2 LC1-D80004

    LUA1C11

    Abstract: LUA1C20 LU9BN11 Schneider Electric lub LUFC00 LULC031 LU2MB lu2mb0 lu2b 8502CT0201
    Text: Motor Starters TeSys U-Line Auxiliary Contact Blocks, Reversing Blocks and Accessories www.us.schneider-electric.com FOR CURRENT INFORMATION Refer to Catalog 8502CT0201 4. Auxiliary Contact Blocks Table 18.113: Contact State for Each Modea Contact Indicates


    Original
    PDF 8502CT0201 LUA1C11 LUA1C20 LU9BN11 Schneider Electric lub LUFC00 LULC031 LU2MB lu2mb0 lu2b 8502CT0201

    LC1-D09

    Abstract: LC1 D09 10 LC1-D18 LC1 D12 10 LC1 contactor LC1 D38 LAD93217 LC1-D80 LC1-D32 contactor d09
    Text: TeSys contactors References 537729 Component parts for assembling reversing contactors for motor control, low-speed/high-speed starters and star-delta starters For 3-pole reversing contactors for motor control Contactors with screw clamp terminals or connectors. Horizontally mounted, assembled by customer


    Original
    PDF

    LC1-D150

    Abstract: bs 5424 schneider LC1-D09 schneider LC1-D09 LC1-D40 LC1 Schneider VDE 0660 BS 5424 lad6k10 LA4 dfb IEC 60947-5-1
    Text: 24505 Page 62 Thursday, October 25, 2001 5:44 PM Characteristics TeSys contactors Model d Farnell Codes ; 4231855 - 4232148 Type of contactor LC1LC1D09…D18 D25…D38 DT20 & DT25 DT32…DT6 LC1D40 1000 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage Ui


    Original
    PDF LC1LC1D09. LC1D40 LC1D50. LC1-D115 LC1-D150 LC1-D09. LC1-D80 LC1-D40. LC1-D150 bs 5424 schneider LC1-D09 schneider LC1-D09 LC1-D40 LC1 Schneider VDE 0660 BS 5424 lad6k10 LA4 dfb IEC 60947-5-1

    LC1-D09

    Abstract: schneider LC1-D09 LC1-D40 LC1 d12008 contactor LC1 D25004 LC1 D25008 LC1-D25 LC1-D65004 LC1-D80 LC1-D80004
    Text: 24531 Page 94 Thursday, October 25, 2001 6:02 PM Dimensions TeSys contactors Model d contactors Control circuit: a.c. LC1-D09…D18 3-pole LC1-D25…D38 (3-pole) LC1-DT20…DT60 (4-pole) 44 Minimum electrical clearance 44 Minimum electrical clearance LA4


    Original
    PDF LC1-D09. LC1-D25. LC1-DT20. LC2-DT20. 21/NC 13/NO LC1-D09 schneider LC1-D09 LC1-D40 LC1 d12008 contactor LC1 D25004 LC1 D25008 LC1-D25 LC1-D65004 LC1-D80 LC1-D80004

    LC2 contactor

    Abstract: LC2-D12 LC2-D09 contactor d09 pp d115 D09P7V D115 D150 LC2-D40 LC2-D150
    Text: References TeSys contactors 5 5 Reversing contactors for motor control up to 75 kW at 400 V, in category AC-3 Horizontally mounted, pre-assembled Control circuit: a.c., d.c. or low consumption 810369 3-pole reversing contactors for connection by screw clamp terminals or connectors


    Original
    PDF 24503-EN LC2 contactor LC2-D12 LC2-D09 contactor d09 pp d115 D09P7V D115 D150 LC2-D40 LC2-D150

    schneider lc1d

    Abstract: schneider LC1-D LC1-D80 008 lc1-d 173 schneider LC1-D80 Schneider Electric LC1d lc1d contactor coils LP1-D65 tesys d contactors CONTACTOR LC1-D115
    Text: References TeSys contactors a.c. coils for 3-pole contactors LC1-D Control circuit voltage Uc V Average resistance at 20 °C ± 10 % Ω Inductance of closed circuit H Reference 1 Weight kg For 3-pole " contactors LC1-D09.D38 and LC1-DT20…DT60 Specifications


    Original
    PDF LC1-D09. LC1-DT20. LC1-D80 LP1-D80 schneider lc1d schneider LC1-D LC1-D80 008 lc1-d 173 schneider LC1-D80 Schneider Electric LC1d lc1d contactor coils LP1-D65 tesys d contactors CONTACTOR LC1-D115

    LC1-D123

    Abstract: LC1-D093 LC1-D323 LC1-D183 LA6-DK20 LC1-D253 LAD6K10 LC1-D150 LAD-4RC LA6DK10
    Text: Characteristics TeSys contactors 5 Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32 & DT40 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage Ui 2 Rated impulse withstand voltage (Uimp) Conforming to IEC EN 947-4-1,


    Original
    PDF LC1LC1LC1D09. LC1D50. LC1-D115 LC1-D150 LC1-D09. LC1-D80 LC1-D40. LC1-D123 LC1-D093 LC1-D323 LC1-D183 LA6-DK20 LC1-D253 LAD6K10 LC1-D150 LAD-4RC LA6DK10

    CONTACTOR LP4 K

    Abstract: LC1 contactor LP1 contactor LC7 CONTACTOR LC1 contactor COIL POWER k0601 LP4 contactor LC-7 K1210 24407
    Text: References 5 TeSys contactors 5 Contactors for motor control, 6 to 16 A in category AC-3 and 6 to 12 A in category AC-4 Control circuit: a.c. 106151_1 Contactor selection according to utilisation category, see pages 24565/2 to 24565/5 and 24566/2 to 24566/5.


    Original
    PDF K0910pp 24402-EN CONTACTOR LP4 K LC1 contactor LP1 contactor LC7 CONTACTOR LC1 contactor COIL POWER k0601 LP4 contactor LC-7 K1210 24407

    lad6k10

    Abstract: LC1 D25004 LC1 d12008 contactor LC1 D25008 LC1-D65004 LC1D65004 LP1D12004 schneider electric LC1 D25 LC1 d40008 LC1 D093
    Text: Dimensions TeSys contactors Model d contactors Control circuit: a.c. LC1-D09…D18 3-pole LC1-D25…D38 (3-pole) LC1-DT20…DT60 (4-pole) 44 Minimum electrical clearance 44 Minimum electrical clearance LA4 b b b1 b1 LA4 D093… D183 99 107 123 (1) 132 (1)


    Original
    PDF LC1-D09. LC1-D25. LC1-DT20. LC2-DT20. 21/NC 13/NO lad6k10 LC1 D25004 LC1 d12008 contactor LC1 D25008 LC1-D65004 LC1D65004 LP1D12004 schneider electric LC1 D25 LC1 d40008 LC1 D093

    LC1 D38

    Abstract: lc1 f265 LC1 F400 LC1-k16 LP1 K12 contactor LC1-D25 Lc1 f630 LP1 K09 LC1-D09 LC1-D18
    Text: Selection 5 TeSys contactors 5 For utilisation category AC-3 Operational current and power conforming to IEC θ y 60 °C 1 Contactor size Maximum operational current in AC-3 Rated operational power P (standard motor power ratings) 2 3 y 440 V A LC1/ LP1


    Original
    PDF

    LC1 contactor

    Abstract: CONTACTOR LP4 K LC1 contactor COIL LC-1 LC1 level control LC1K K09004 LC1 DC 24403-EN LC7 CONTACTOR
    Text: References 5 TeSys contactors 5 Contactors for control in category AC-1, 20 A Control circuit: a.c. 106150_1 Contactor selection according to utilisation category, see pages 24561/2 and 24565/3. Mounting on 35 mm 7 rail or Ø 4 screw fixing. Screws in the open “ready-to-tighten” position.


    Original
    PDF 24403-EN LC1 contactor CONTACTOR LP4 K LC1 contactor COIL LC-1 LC1 level control LC1K K09004 LC1 DC LC7 CONTACTOR

    schneider LRD 08

    Abstract: LRD schneider relay LC1-D65 LC1-D50 Schneider Electric LRD 06 LR9-D5369 LC1-D09 schneider overload relay schneider LC1-D09 LRD-21
    Text: 24516 Page 108 Friday, October 26, 2001 9:32 AM Description, characteristics TeSys protection components 3-pole thermal overload relays, model d Description Model d 3-pole thermal overload relays are designed to protect a.c. circuits and motors against overloads, phase failure,


    Original
    PDF LRD-01. LRD-3322. LR9-D67 LR9-D69 schneider LRD 08 LRD schneider relay LC1-D65 LC1-D50 Schneider Electric LRD 06 LR9-D5369 LC1-D09 schneider overload relay schneider LC1-D09 LRD-21

    schneider LC1-D09 wiring diagram

    Abstract: LC1-D38 LC1-D18 LT6P0M005FM LC2K06 LC1-D09 installation manual LC1K0910BD 8502CT9901 LC1K0910P7 LC1-D12
    Text: Motor control Accurate and reliable control of motors Te Sys range provide you more simplicity, compactness, openness and flexibility . so man y evolutions and new items to aid your productivity. Search By Part Number TeSys For a new start! A range of simple,


    Original
    PDF 9422CLA50 9422CLA51 9422CLA10 9422CLA11 9422CSF30 9422CSF50 9422CSF70 9422CSF10 9422CSF304 9422CSF504 schneider LC1-D09 wiring diagram LC1-D38 LC1-D18 LT6P0M005FM LC2K06 LC1-D09 installation manual LC1K0910BD 8502CT9901 LC1K0910P7 LC1-D12

    schneider LC1-D38

    Abstract: LC1-D38 LC1-D09 LC1-D123 lc1d128 LC1-D093 LC1D09 schneider LC1-DT25 schneider LC1-D258 schneider LC1-D09
    Text: References TeSys contactors For motor control up to 75 kW at 400 V, in category AC-3 Control circuit: a.c., d.c. or low consumption 810356 3-pole contactors for connection by screw clamp terminals or connectors Standard power ratings of 3-phase motors 50/60 Hz in category AC-3


    Original
    PDF LC1-D09// LC1-D12// LC1-D18// LC1-D25// LC2-DT20. schneider LC1-D38 LC1-D38 LC1-D09 LC1-D123 lc1d128 LC1-D093 LC1D09 schneider LC1-DT25 schneider LC1-D258 schneider LC1-D09

    bva04

    Abstract: D656 tesys d contactors K065 D406 D806 M7230 IEC 60439-1 start return ac motors LE4-D09
    Text: TeSys enclosed starters Characteristics, references 2 2 D.O.L. starters for motor control 1 2.2 to 45 kW, with isolating device Characteristics Conforming to standards IEC 60947-4-1 and IEC 60439-1, VDE 0660-102, EN 60947 Ambient air temperature IP 659: LEp K


    Original
    PDF D09907 D09F7A04. 24103-EN bva04 D656 tesys d contactors K065 D406 D806 M7230 IEC 60439-1 start return ac motors LE4-D09

    LA2 DS2

    Abstract: star-delta starting motors 160 kw star delta starter current starter voltage 75 kw tesys d contactors D806 star delta starter LE3 LA2Ds2 contactor d09 IEC 60439-1
    Text: Characteristics, references TeSys enclosed starters 2 2 Star-delta starters 1 7.5 to 75 kW with isolating device Characteristics Conforming to standards IEC 60947-4-1 and IEC 60439-1, VDE 0660-102, EN 60947 Degree of protection conforming to IEC 60529 Ambient air temperature


    Original