Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    STRAIN RESISTOR Search Results

    STRAIN RESISTOR Result Highlights (2)

    Part ECAD Model Manufacturer Description Download Buy
    37-1409 Coilcraft Inc Tuning tool Visit Coilcraft Inc Buy
    37-2182 Coilcraft Inc Tuning tool Visit Coilcraft Inc Buy

    STRAIN RESISTOR Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    STRAIN GAUGE

    Abstract: strain gauge amplifier circuit how to use STRAIN GAUGE strain gauge conditioner circuit "strain gauge" Wheatstone Bridge amplifier strain gauge amplifier excitation full bridge SCXI-1121 strain gauge sensor SC-2043-SG
    Text: Application Note 078 Strain Gauge Measurement – A Tutorial What is Strain? Strain is the amount of deformation of a body due to an applied force. More specifically, strain ε is defined as the fractional change in length, as shown in Figure 1 below. ε=


    Original
    PDF

    strain gauge amplifier rs 846171 circuit

    Abstract: strain gauge amplifier circuit STRAIN GAUGE transducer measure weight strain gauge in load cell Rs e18045 strain gauge amplifier E18045 load cell amplifier Weighing gauge circuit foil wire full bridge strain gauge
    Text: Issued July 1994 E18045 Strain gauges and load cells Strain gauges Two ranges of foil strain gauges to cover general engineering requirements for strain analysis. All gauges have 30mm integral leads to alleviate damage to the gauges due to excessive heat being applied


    Original
    E18045 strain gauge amplifier rs 846171 circuit strain gauge amplifier circuit STRAIN GAUGE transducer measure weight strain gauge in load cell Rs e18045 strain gauge amplifier E18045 load cell amplifier Weighing gauge circuit foil wire full bridge strain gauge PDF

    IN827

    Abstract: strain gauge amplifier rs 846171 circuit strain gauge amplifier circuit strain gauge amplifier schematic Weighing gauge circuit Strain gauges and load cells 232-5957 strain gauge amplifier 102 load cell 100kg foil wire full bridge strain gauge strain gauge in load cell
    Text: Issued September 2001 232-5957 Data Pack E Data Sheet Strain gauges and load cells Strain gauges Two ranges of foil strain gauges to cover general engineering requirements for strain analysis. All gauges have 30mm integral leads to alleviate damage to the gauges due to excessive heat being applied


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Series 106 3D TrackStik 3 Axis Ceramic Strain Gage Pointing Device Series 108 3D TrackStik ® 3 Axis Ceramic Strain Gage Pointing Device Type 106B Top View R 4.30 0.169 Features: • • • • • • • • • • Smooth X and Y Motion Control Solid Ceramic Thick Film Strain Resistors


    Original
    PDF

    34CH0200G

    Abstract: health data sheet egypt
    Text: Force and strain sensors. Measure. Test. Control. Edition 2015 Force and strain sensors by Baumer combine tried and tested technology and sophisticated innovations. 1 Contents. Introduction 1 Display Boxes DDBF Product key  1.2 Summary Force and Strain Sensors1.4


    Original
    CH-8501 34CH0200G health data sheet egypt PDF

    Untitled

    Abstract: No abstract text available
    Text: SINGLE-CHANNEL, PORTABLE STRAIN GAGE MONITORING SYSTEM Strain Gages Sold Separately See Page E-8 DMD-21 Shown smaller than actual size DMD-21 2715 $ SPECIFICATIONS ߜ Highly Stable Measurement ߜ Battery & AC Power ߜ Reads Directly in Micro Strain & Engineering


    Original
    DMD-21 DMD-21 DMD-21: DMD-21SB: DMD21SB PDF

    Untitled

    Abstract: No abstract text available
    Text: PDFINFO H5 6 0 5 - 0 1 8-Channel 350 Ω Strain Relay Multiplexer HP E1356A Technical Specifications ● ● ● ● ● 8-Channel 350 Ω strain gage relay multiplexer Strain gage measurements with bridge completion + 5 V excitation circuitry-quarter, half, and full


    Original
    E1356A E1356A E1345-66201) 17-21/F 5965-5605E PDF

    Untitled

    Abstract: No abstract text available
    Text: PDFINFO H5 6 0 4 - 0 1 8-Channel 120 Ω Strain Relay Multiplexer HP E1355A Technical Specifications ● ● ● ● ● 8-Channel 120 Ω strain gage relay multiplexer Strain gage measurements with bridge completion + 5 V excitation circuitry—quarter, half, and full


    Original
    E1355A E1355A E1345-66201) 95/NT E1355-80001 5965-5604E PDF

    Untitled

    Abstract: No abstract text available
    Text: PDFINFO H5 6 0 4 - 0 1 8-Channel 120 Ω Strain Relay Multiplexer HP E1355A Technical Specifications ● ● ● ● ● 8-Channel 120 Ω strain gage relay multiplexer Strain gage measurements with bridge completion + 5 V excitation circuitry—quarter, half, and full


    Original
    E1355A E1355A E1345-66201) 17-21/F 5965-5604E PDF

    E1403

    Abstract: 6214C
    Text: PDFINFO H5 6 0 5 - 0 1 8-Channel 350 Ω Strain Relay Multiplexer HP E1356A Technical Specifications ● ● ● ● ● 8-Channel 120 Ω strain gage relay multiplexer Strain gage measurements with bridge completion + 5 V excitation circuitry-quarter, half, and full


    Original
    E1356A E1356A E1345-66201) 95/NT E1356-80001 5965-5605E E1403 6214C PDF

    Untitled

    Abstract: No abstract text available
    Text: Agilent E1506A, E1507A 120 Ω and 350 Ω Strain Completion and Excitation SCPs Data Sheet Use with Agilent E1413C/E1415A/E1419A 120 Ω and 350 Ω strain completion and excitation • Connections for quarter, half, and full bridges • Requires an input SCP to make strain gage measurements


    Original
    E1506A, E1507A E1413C/E1415A/E1419A E1506A E1507A E1506A 5988-2340EN PDF

    Untitled

    Abstract: No abstract text available
    Text: OMB-DBK43A 8-Channel Strain-Gage Module for OMB-DAQBOOK, DAQBOARD and OMB-LOGBOOK Model OMB-DBK43A 2495 $ MADE IN USA The OMB-DBK43A provides 8 channels of strain-gage input for the OMB-LOGBOOK, OMB-DAQBOOK and DAQBOARD ߜ Provides Eight Channels of Strain-Gage Input


    Original
    OMB-DBK43A OMB-DBK43A OMB-CA-37-x OMB-CA-131-x OMB-CA-132 OMB-DBK43A) PDF

    Untitled

    Abstract: No abstract text available
    Text: =M=M= Transducer-Class Strain Gages Bondable Resistors Installation Accessories * VISHD011


    OCR Scan
    VISHD011 PDF

    Untitled

    Abstract: No abstract text available
    Text: 10-CHANNEL PORTABLE STRAIN GAGE MONITORING SYSTEM Shown smaller than actual size ߜ Reads Directly in Micro Strain & Engineering Units ߜ Independent Zeroing On Each Channel ߜ High Accuracy and Resolution Selectable bridge configuration via internal fixed resistors eliminates


    Original
    10-CHANNEL DMD-22 DMD-22 DMD-21 DMD-21SB PDF

    Untitled

    Abstract: No abstract text available
    Text: STRAIN GAGE BRIDGE COMPLETION MODULE BCM-1 69 $ Model BCM-1 Shown with DP302-S Meter and KFG Series Strain Gage See www.omega.com MADE IN USA ߜ Internal Bridge Balance Adjustment Standard, for Nulling Out Unstrained Conditions ߜ 1⁄4 Bridge Completion for 120 or 350 Ω Strain


    Original
    DP302-S 25dge PDF

    strain gage

    Abstract: full bridge strain gage E1501A
    Text: PDFINFO H2 3 8 6 - 0 1 120 Ω Strain Completion and Excitation SCP HP E1506A Technical Specifications ● ● ● ● Use with HP E1313A/E1413C/E1415A/E1419A 120 Ω strain completion and excitation Connections for quarter, half, and full bridge Requires an input SCP to make strain gage


    Original
    E1506A E1313A/E1413C/E1415A/E1419A E1506A E1507A E1508A E1509A E1510A E1511A strain gage full bridge strain gage E1501A PDF

    Untitled

    Abstract: No abstract text available
    Text: SPECTRUM CONTROL INC. \ Hooded Strain Reliefs Hooded strain reliefs are used whenever a connector is used on a cable assembly which will be exposed to users and subject to multiple disconnects. Hoods are designed to protect users from shock hazard by exposed solder joints, as well as provide a strain relief


    OCR Scan
    PDF

    sense opt

    Abstract: E1507A
    Text: PDFINFO H2 3 8 5 - 0 1 350 Ω Strain Completion and Excitation SCP HP E1507A Technical Specifications ● ● ● ● Use with HP E1313A/E1413C/E1415A/E1419A 350 Ω strain bridge completion and excitation Connections for quarter, half, and full bridge Requires an input SCP to make strain gage


    Original
    E1507A E1313A/E1413C/E1415A/E1419A E1507A E1506A E1508A E1509A E1510A E1511A sense opt PDF

    Untitled

    Abstract: No abstract text available
    Text: Standard S-Type, Wire-Wound, and Hermetic Resistors Micro-Measurements Specifications and Selection Charts Fixed resistors have two primary uses in strain gage circuits: shunt calibration of strain-measuring instrumentation, and bridge completion. For shunt calibration, a fixed resistor is


    Original
    27-Apr-2011 PDF

    S-5880

    Abstract: W-174650-02 W-349650-02 S-87150-01 S-34650-01 S-59880-01 S-1000-01 S-43400-01 W-249000-02 S-57983-01
    Text: Standard S-Type, Wire-Wound, and Hermetic Resistors Vishay Micro-Measurements Specifications and Selection Charts Fixed resistors have two primary uses in strain gage circuits: shunt calibration of strain-measuring instrumentation, and bridge completion. For shunt calibration, a fixed resistor is


    Original
    08-Apr-05 S-5880 W-174650-02 W-349650-02 S-87150-01 S-34650-01 S-59880-01 S-1000-01 S-43400-01 W-249000-02 S-57983-01 PDF

    Wheatstone Bridge amplifier

    Abstract: wheatstone bridge with temp. sensor strain gage amplifier strain gauge amplifier full bridge strain gage pressure sensor strain gage pressure sensor AM457 circuit amplifier precision for Wheatstone Bridge strain gage Wheatstone Bridge
    Text: Application description AN1011: AM457 precision amplifier IC for strain gage elements This article describes a strain gag sensor circuit using the integrated circuit AM457 device to amplify and calibrate the output signal of a strain gage element with a Wheatstone resistance bridge. The aim is to obtain a ratiometric output signal Uout


    Original
    AN1011: AM457 AM457 AN1012: Wheatstone Bridge amplifier wheatstone bridge with temp. sensor strain gage amplifier strain gauge amplifier full bridge strain gage pressure sensor strain gage pressure sensor circuit amplifier precision for Wheatstone Bridge strain gage Wheatstone Bridge PDF

    Untitled

    Abstract: No abstract text available
    Text: AA SPECTRUM CONTROL INC. Hooded Strain Reliefs Hooded strain reliefs are used whenever a connector is used on a cable assembly which will be exposed to users and subject to multiple disconnects. Hoods are designed to protect users from shock hazard by exposed solder joints, as well as provide a strain relief


    OCR Scan
    PDF

    cFP-2120

    Abstract: 778805-90
    Text: Strain Gage Module for Compact FieldPoint NI cFP-SG-140 • Accepts full- and half-bridge strain gage inputs directly • Quarter-bridge gages require external bridge-completion resistor • Compatible with load cells, force sensors, and torque sensors • Built-in signal conditioning


    Original
    cFP-SG-140 16-bit 15/ovides 51573A-01* 51573A-01 2007-9297-161-101-D cFP-2120 778805-90 PDF

    Fluke 725 diagram

    Abstract: No abstract text available
    Text: Application Note 1818 Author: Don LaFontaine Intersil and Freescale Thermocouple and Strain Gauge Reference Design Introduction Ordering Information The “Intersil and Freescale Thermocouple and Strain Gauge Reference Design” illustrates two sensor applications using


    Original
    KL25Z FRDM-KL25Z AN1818 Fluke 725 diagram PDF