Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    STEP UP TRANSFORMER 230 Search Results

    STEP UP TRANSFORMER 230 Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    LPR6235-253L Coilcraft Inc Step-up transformer, SMT, RoHS Visit Coilcraft Inc
    LPR6235-123Q Coilcraft Inc Step-up transformer, SMT, RoHS Visit Coilcraft Inc
    LPR6235-752R Coilcraft Inc Step-up transformer, SMT, RoHS Visit Coilcraft Inc
    LPR6235-253P Coilcraft Inc Step-up transformer, SMT, RoHS Visit Coilcraft Inc
    LPR6235-752S Coilcraft Inc Step-up transformer, SMT, RoHS Visit Coilcraft Inc

    STEP UP TRANSFORMER 230 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    230VAC transformers

    Abstract: 298C 298D 298E 298F 298G step up transformer 12 Step-up Transformers
    Text: Hammond Isolating Line Step-Up Transformers - (298 Series) ISOLATION - STEP UP PLUG IN - EURO (115VAC - 230VAC) Path: Home > Transformer Index > Line > Isolation - Step Up - Plug In (Euro) Key Features: ● Primary 115VAC, 50/60 Hz., Secondary 230VAC.


    Original
    PDF 115VAC 230VAC) 115VAC, 230VAC. 5-15P) inc02 com/298 230VAC transformers 298C 298D 298E 298F 298G step up transformer 12 Step-up Transformers

    high frequency step up transformer

    Abstract: TRANSFORMER CT surface mount MABACT0011 7080
    Text: 1:4 Flux Coupled Step up Transformer Rev B MABACT0011 1 - 350 MHz SM-22B Features: • Surface Mount • 1:4 Impedence • CT on Secondary • Available on tape & reel 123 Description 5 4 M/A-COM’s MABACT0011 is a 1:4 RF flux coupled step-up transformer in a low


    Original
    PDF MABACT0011 SM-22B MABACT0011 high frequency step up transformer TRANSFORMER CT surface mount 7080

    high frequency step up transformer

    Abstract: MABACT0011
    Text: 1:4 Flux Coupled Step up Transformer Rev B MABACT0011 1 - 350 MHz SM-22B Features: • Surface Mount • 1:4 Impedance • CT on Secondary • Available on tape & reel 123 Description 5 4 M/A-COM’s MABACT0011 is a 1:4 RF flux coupled step-up transformer in a low


    Original
    PDF MABACT0011 SM-22B MABACT0011 high frequency step up transformer

    P-8637

    Abstract: Stancor power transformer EMERSON rectifier stancor rectifier transformer transformer 230
    Text: A U T O / I S O L A T I O N T R A N S F O R M E R S Step-Down, Step-Up and Isolation Transformers Isolation Transformer STANCOR PART Sec. NUMBER A B RMS Test V.A. Cap. Voltage Type Voltage Step Input Voltage Output Voltage Amps P-6287 Auto Down 230 115 0.35


    Original
    PDF P-6287 P-8620 GSD-75 P-8630 GSD-100 P-8631 GSD-150 P-8632 GSD-250 GSD-300 P-8637 Stancor power transformer EMERSON rectifier stancor rectifier transformer transformer 230

    step up transformer 230

    Abstract: control autotransformer E-JET500 AA94 VDE0570
    Text: Vorschalt-Spartransformator E-JET Autotransformer E-JET Range ü Zur Anpassung von 110 V-Geräten an das 230 V Netz Step up transformer 110 V to 230 V ü Elektronische Potentialüberwachung Electronic potential control Autotransformer to IEC 61558-2-13, DIN EN 61558-2-13,


    Original
    PDF

    DRV1100

    Abstract: DRV1100P DRV1100U OPA2650
    Text: DRV1100 DR OPVA1100 658 DRV 110 HIGH POWER DIFFERENTIAL DRIVER AMPLIFIER FEATURES DESCRIPTION ● HIGH OUTPUT CURRENT: 230mA The DRV1100 is fixed gain differential line driver designed for very low harmonic distortion at the high powers required of xDSL line interface standards.


    Original
    PDF DRV1100 OPV1100 230mA DRV1100 230mA 17dBm OPA2650 DRV1100P DRV1100U OPA2650

    DRV1100

    Abstract: DRV1100P DRV1100U OPA2650
    Text: DRV1100 DR OPVA1100 658 DRV 110 HIGH POWER DIFFERENTIAL DRIVER AMPLIFIER FEATURES DESCRIPTION ● HIGH OUTPUT CURRENT: 230mA The DRV1100 is fixed gain differential line driver designed for very low harmonic distortion at the high powers required of xDSL line interface standards.


    Original
    PDF DRV1100 OPV1100 230mA DRV1100 230mA 17dBm OPA2650 DRV1100P DRV1100U OPA2650

    AN 7591 POWER AMPLIFIER

    Abstract: an 7591 power amp AL 2712 Forward Transformer Design B20 zener diode TOP247Y equivalent TOP247 magnetic amplifier saturable core b90 zener AC double voltmeter -AE make
    Text: ® TOPSwitch-GX Forward Design Methodology Application Note AN-30 Scope This application note is for engineers designing an AC-DC power supply using TOPSwitch-GX in a single-ended forward converter. It addresses single input voltage 230 VAC or doubled 115 VAC input, but does not address universal input 85 V to


    Original
    PDF AN-30 AN 7591 POWER AMPLIFIER an 7591 power amp AL 2712 Forward Transformer Design B20 zener diode TOP247Y equivalent TOP247 magnetic amplifier saturable core b90 zener AC double voltmeter -AE make

    DIODE smd B44

    Abstract: b48 DIODE schottky ef12.6 core transformer creepage schottky b37 diode LNK613DN lnk616 ee10 transformer EEL-19 EE16W lnk616 pg
    Text: Application Note AN-44 LinkSwitch-II Family Design Guide Introduction of no-load power at 230 VAC without an external bias circuit, and to consume below 30 mW with a low-cost bias circuit. This simplifies meeting harmonized energy efficiency standards such


    Original
    PDF AN-44 DIODE smd B44 b48 DIODE schottky ef12.6 core transformer creepage schottky b37 diode LNK613DN lnk616 ee10 transformer EEL-19 EE16W lnk616 pg

    nec2501

    Abstract: B26 ZENER DIODE NEC2501 Optocoupler NEC2501* Opto coupler SMPS 12V, 5V power integrations AN-16 topswitch topswitch flyback SMPS 12V power integrations ST204A zener Diode B19
    Text: ® TOPSwitch Flyback Design Methodology Application Note AN-16 Designing an off-line switching power supply involves many aspects of electrical engineering: analog and digital circuits, bipolar and MOS power device characteristics, magnetics, thermal considerations, safety requirements, control loop


    Original
    PDF AN-16 nec2501 B26 ZENER DIODE NEC2501 Optocoupler NEC2501* Opto coupler SMPS 12V, 5V power integrations AN-16 topswitch topswitch flyback SMPS 12V power integrations ST204A zener Diode B19

    ESTAMAT power factor

    Abstract: No abstract text available
    Text: Mounting Instructions / Manual MV1171 POWER FACTOR Controller ESTAmat MH-N Vishay Electronic GmbH ESTA Capacitors Division Hofmark-Aich-Strasse 36 84030 Landshut, Germany Phone +49- 0 871-86 0, Fax +49-(0)871 - 86 25 12 Document Number 13156


    Original
    PDF MV1171 19-April-2011 139x139 ESTAMAT power factor

    Untitled

    Abstract: No abstract text available
    Text: Line Transformer - Selection Guide Steps To Proper Transformer Selection 1 What power is available you need to know both voltage & frequency). 2) Check the operating voltage of your equipment (is it single voltage or multiple?). 3) What line frequency will your equipment run on? Either 50, 60 or dual 50/60 Hz.


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: UM10607 BGA7350 performance at IF=230 MHz Rev. 1 — 14 November 2012 User manual Document information Info Content Keywords Dual VGA. 28 dB attenuator range IF=230 MHz NXP Abstract This User Manual describes the functionality and performance of the single ended BGA7350 evaluation board, tuned for a IF of 230 MHz


    Original
    PDF UM10607 BGA7350

    Untitled

    Abstract: No abstract text available
    Text: A57 Universal Desktop 30VA Transformer Series Features • • • • • • • • • • • • 230 VAC Input Euro Wall Plug Style Rated for Continuous Duty AC outputs up to 30VA Meets Safety Agency Requirements Complies with EMI/RFI Regulations CE Compliant


    Original
    PDF EN60950

    Untitled

    Abstract: No abstract text available
    Text: C41 UK Wall Mount 8VA Transformer Series Features • • • • • • • • • • • • 230 VAC Input UK Wall Plug Style Rated for Continuous Duty AC outputs up to 8VA Meets Safety Agency Requirements Complies with EMI/RFI Regulations CE Compliant


    Original
    PDF C41-061333-A000G C41-071140-A000rating EN60950

    Untitled

    Abstract: No abstract text available
    Text: C57 UK Dual Cord 30VA Transformer Series Features • • • • • • • • • • • • 230 VAC Input UK Dual Cord Style Rated for Continuous Duty AC outputs up to 30VA Meets Safety Agency Requirements Complies with EMI/RFI Regulations CE Compliant


    Original
    PDF C57ating EN60950

    calculation of transformer differential relay RET 670

    Abstract: SWITCHYARD IEC61850 SWITCHYARD LAYOUT 053-BEN RTXP24 RK795101-DC mva transformer calculation of transformer earthing resistor TR-29
    Text: Transformer protection IED RET 670 Buyer's Guide Open Configuration 1MRK 504 053-BEN Revision: G Issued: February 2007 Data subject to change without notice Page 1 Features • • A protection, control, and monitoring IED with extensive functional library and configuration


    Original
    PDF 053-BEN three-winding12 001-BEN 012-BEN 065-UEN 075-WEN 077-WEN 1KHA001027 1MRS755552 SE-721 calculation of transformer differential relay RET 670 SWITCHYARD IEC61850 SWITCHYARD LAYOUT 053-BEN RTXP24 RK795101-DC mva transformer calculation of transformer earthing resistor TR-29

    calculation of transformer differential relay RET 670

    Abstract: 40 MVA transformer mva transformer three winding transformer RET670 calculation of line differential relay RED 670 calculation of transformer earthing resistor IEC61850 calculation of transformer differential relay RED 670 diode CODE 51n
    Text: Transformer protection IED RET 670 Buyer's Guide Pre-configured 1MRK 504 080-BEN Revision: G Issued: February 2007 Data subject to change without notice Page 1 Features • Four configuration alternatives for single- or multi-breaker arrangements available – ready to


    Original
    PDF 080-BEN 075-WEN 077-WEN 1KHA001027 1MRS755552 SE-721 calculation of transformer differential relay RET 670 40 MVA transformer mva transformer three winding transformer RET670 calculation of line differential relay RED 670 calculation of transformer earthing resistor IEC61850 calculation of transformer differential relay RED 670 diode CODE 51n

    Untitled

    Abstract: No abstract text available
    Text: A57 Euro Dual Cord 30VA Transformer Series Features • • • • • • • • • • • • 230 VAC Input Euro Dual Cord Style Rated for Continuous Duty AC outputs up to 30VA Meets Safety Agency Requirements Complies with EMI/RFI Regulations CE Compliant


    Original
    PDF EN60950

    70181919AW

    Abstract: RE-045 431 regulator 64676-12bx 14C271 SURGE SUPPRESSOR MOV 230V DIGITAL RPM METER SCHEMATIC 14C651 reliance 150 HP dc motor MANUAL 14C300 14C401
    Text: Installing, Operating and Maintaining FlexPak Plus DĆC VKS Drives and Modification Kits 3ĆPhase Nonregenerative 3 - 20hp at 230V/3ĆPhase AĆC Input 3 - 40hp at 460V/3ĆPhase AĆC Input Instruction Manual DĆ3938Ć2 December, 1991 SECTION 1 INTRODUCTION


    Original
    PDF 30V/3Phase 60V/3Phase D39382 D-3938-2­ 70181919AW RE-045 431 regulator 64676-12bx 14C271 SURGE SUPPRESSOR MOV 230V DIGITAL RPM METER SCHEMATIC 14C651 reliance 150 HP dc motor MANUAL 14C300 14C401

    12v to 220v step up transformer

    Abstract: 220V ferrite core transformer mosfet 5kw high power rf circuit diagram of 13.56MHz RF Generator SCHEMATIC 5kw power supply 30A DRF1300 13.56MHZ 3KW GENERATOR 2kw mosfet step down transformer 220V to 12V 232 Matching Transformer line matching
    Text: Application Note 1812 August 2010 13.56 MHz, Class D Push-Pull, 2KW RF Generator with Microsemi DRF1300 Power MOSFET Hybrid Gui Choi Sr. Application Engineer Phone: 541-382-8028, ext. 1205 gchoi@microsemi.com The DRF1300/CLASS-D Reference design is available to expedite the evaluation of the DRF1300 push-pull


    Original
    PDF DRF1300 DRF1300/CLASS-D 12v to 220v step up transformer 220V ferrite core transformer mosfet 5kw high power rf circuit diagram of 13.56MHz RF Generator SCHEMATIC 5kw power supply 30A 13.56MHZ 3KW GENERATOR 2kw mosfet step down transformer 220V to 12V 232 Matching Transformer line matching

    Untitled

    Abstract: No abstract text available
    Text: B U R R -B R O W N DRV1101 HIGH POWER DIFFERENTIAL LINE DRIVER DESCRIPTION FEATURES HIGH OUTPUT CURRENT: 230mA SINGLE SUPPLY OPERATION: 5V 10MHz BANDWIDTH: 6Vp-p into 15£2 VERY LOW THD AT HIGH POWER: -81dBc at 6Vp-p, 100kHz, 100£2 FIXED DIFFERENTIAL GAIN: 3V/V


    OCR Scan
    PDF DRV1101 230mA 10MHz -81dBc 100kHz, DRV1101 DRV1101. DRV1101U.

    Untitled

    Abstract: No abstract text available
    Text: B U R R -B R O W N DRV1101 HIGH POWER DIFFERENTIAL LINE DRIVER FEATURES DESCRIPTION • HIGH OUTPUT CURRENT: 230mA The DRV 1101 is fixed gain differential line driver designed for very low distortion operation when driv­ ing DSL line transformers. It is designed for use as the


    OCR Scan
    PDF DRV1101 230mA 230mA DRV1101 25dBm. ZZ182

    T-2-53515-3S

    Abstract: autotransformer
    Text: Questions and Artsvvers about Buck-Boost 1 1. What is a buck-boost transformer? Buck-boost transformers are small single phase transformers designed to re duce buck or raise (boost) line volt­ age from 5-20%. The most common example is boosting 208 volts to 230


    OCR Scan
    PDF