Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    SF6 GAS Search Results

    SF6 GAS Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    SGAS701 Renesas Electronics Corporation Trace Hydrogen Gas Sensor Visit Renesas Electronics Corporation
    Household-Gas-Alarm Renesas Electronics Corporation Household Gas Alarm Reference Design Visit Renesas Electronics Corporation
    SGAS711 Renesas Electronics Corporation Flammable Gas Sensor - Methane, Propane, Hydrogen, LPG Visit Renesas Electronics Corporation
    High-End-Gas-Cooker Renesas Electronics Corporation High-End Gas Cooker Reference Design Visit Renesas Electronics Corporation
    SMOD711KITV1 Renesas Electronics Corporation Flammable Gas Leak Sensor Evaluation Kit Visit Renesas Electronics Corporation

    SF6 GAS Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    GEC Alsthom Switchgear

    Abstract: raychem termination instructions gec switchgear merlin gerin catalogue raychem TERMINATION CABLE 36 KV GEC Alsthom merlin gerin switchgear raychem RICS calor emag Switchgear
    Text: R RICS – Insulated adapter termination system for SF6-insulated switchgear up to 24 kV RICS – Insulated adapter termination system for SF6-insulated switchgear up to 24 kV The increasing popularity of gas insulated switchgear called for the development


    Original
    PDF

    kilovac KC 4

    Abstract: KC-15 KC-16 MIL-R-83725
    Text: 15 kV Kilovac KC-15 Features: Make Only • SF-6 gas-filled for power switching on the "make" • Long load life in capacitive discharge applications • Recommneded for ESD testing and safety interlock applications • Meets requirements of MIL-R-83725 Kilovac KC-16


    Original
    KC-15 MIL-R-83725 KC-16 kilovac KC 4 KC-15 KC-16 MIL-R-83725 PDF

    K70 Package

    Abstract: transistor k70
    Text: 70 kV Kilovac K70A, K70B Kilovac K70C Part Number Features: Make Only • New, small, compact 70 kV relay package • SF-6 gas-filled for capacitive discharge and high voltage isolation applications • Ideal for charging and discharging of high voltage capacitors


    Original
    PDF

    kilovac

    Abstract: No abstract text available
    Text: 35 kV Kilovac K61A, K61B Kilovac K61C Features: Make Only • SF-6 gas-filled relay excellent for capacitive discharge applications • Widely used in test equipment and medical instruments • Fully operable in air and suitable for adverse environments Features:


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: 35 kV Kilovac K61A, K61B Kilovac K61C Features: Make Only • SF-6 gas-filled relay excellent for capacitive discharge applications • Widely used in test equipment and medical instruments • Fully operable in air and suitable for adverse environments Features:


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: High Voltage Voltage Film Resistors Resistors Thick Film Welwyn Components F Series F Series Working voltage voltage up up to to 28kV 28kV • Working Resistance up to 150G up to 150G • Resistance Termination variants • Termination Sets suppliedvariants


    Original
    IEC62 20/box PDF

    Untitled

    Abstract: No abstract text available
    Text: 750a, 753, 755 Refrigeration Leak Detectors APPLICATIONS The 700 series automatically detects all existing refrigerants and blends including 404A, PURON 410A and *R-507 AZ50 . Whether testing for leaks in air conditioning,refrigeration, or automotive AC,


    Original
    R-507 750ppm RLD-1105 PDF

    Untitled

    Abstract: No abstract text available
    Text: 750a, 753, 755 Refrigeration Leak Detectors APPLICATIONS The 700 series automatically detects all existing refrigerants and blends including 404A, PURON 410A and *R-507 AZ50 . Whether testing for leaks in air conditioning,refrigeration, or automotive AC,


    Original
    R-507 750ppm RLD-1105 PDF

    Untitled

    Abstract: No abstract text available
    Text: Creating harmony with the environment INPUT Business Activities and Environmental Impact INPUT Energy 1,456,395 GJ Japan [Japan] ● Electricity : 134 million kWh ● Gas The SII Group believes that understanding environmental impact throughout the product life cycle is essential to properly


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Resistors High Voltage Make Possible ThickVoltage Film Resistors High Thick Film Resistors F Series Welwyn Components Working voltage up to 28kV F•Series up to 150G • Resistance Working voltage up to 28kV variants • Termination Resistance up to 150G


    Original
    2011/65/EU IEC62 20/box PDF

    F43D

    Abstract: F43KU F44D F44KU IEC62
    Text: High Voltage Thick Film Resistors Welwyn Components F Series • • • • • Working voltage up to 28kV Resistance up to 150G Termination variants Sets supplied with matched characteristics Good ratio matching over wide voltage range Electrical Data F43


    Original
    IEC62 20/box F43D F43KU F44D F44KU PDF

    Untitled

    Abstract: No abstract text available
    Text: High Voltage Precision Thick Film Resistors Welwyn Components T Series s Working voltage up to 100kV s Resistances up to 50G s TCR down to 25ppm s Termination variants s Sets of resistors with matched characteristics Electrical Data T43 T44 T48 Power rating at 20°C


    Original
    100kV 25ppm 50ppm/ 250ppm/ IEC62 20/box 100ppm/ 25ppm/ PDF

    T43D

    Abstract: T43KU T44D T44KU T48D transformer oil marking code 50G 100KV
    Text: High Voltage Precision Thick Film Resistors Welwyn Components T Series s Working voltage up to 100kV s Resistances up to 50G s TCR down to 25ppm s Termination variants s Sets of resistors with matched characteristics Electrical Data T43 T44 T48 Power rating at 20°C


    Original
    100kV 25ppm 250ppm/ IEC62 20/box 100ppm/ 25ppm/ T43D T43KU T44D T44KU T48D transformer oil marking code 50G 100KV PDF

    telemecanique altivar 31 fault codes

    Abstract: Schneider contactor catalogue schneider 3 phase monitoring relay 11kv scr APC Smart UPS repair for vip tracking gsm and gps technology Schneider LF1 POLE CONTACT RESISTANCE switchgear GEC Alsthom Switchgear schematic diagram online UPS for high frequency
    Text: Medium Voltage Distribution Medium Voltage Products and Equipment Australian Catalogue 2013 Index Secondary Distribution Switchgear 1 Ring Main Unit RMU 2 Primary Distribution Switchgear 3 Outdoor Housing 4 Electrical Houses 5 GIS-Type Metal-Enclosed Switchgear


    Original
    AMTED2190810AU telemecanique altivar 31 fault codes Schneider contactor catalogue schneider 3 phase monitoring relay 11kv scr APC Smart UPS repair for vip tracking gsm and gps technology Schneider LF1 POLE CONTACT RESISTANCE switchgear GEC Alsthom Switchgear schematic diagram online UPS for high frequency PDF

    kilovac KM17

    Abstract: CII Technologies KM17 KM-17 265VDC
    Text: 7.5 kV Kilovac KM-17 Features: • Double pole, double throw contacts • SF-6 gas-filled for ideal discharge waveform • High voltage flying leads • Tabs for easy mount • Widely used in defibillator applications Make Only Load Switching Features: PRODUCT SPECIFICATIONS


    Original
    KM-17 kilovac KM17 CII Technologies KM17 KM-17 265VDC PDF

    T44KU

    Abstract: No abstract text available
    Text: High Voltage Precision Thick Film Resistors Welwyn Components T Series • Working voltage up to 100kV • Resistances up to 50G • TCR down to 25ppm • Termination variants • Sets of resistors with matched characteristics Electrical Data T43 T44 T48 Power rating at 20°C


    Original
    100kV 25ppm 250ppm/ T43KUue IEC62 20/box 100ppm/ 25ppm/ T44KU PDF

    kilovac km13

    Abstract: defibrillator kilovac CII Technologies relay defibrillator circuits Gas discharge 265VDC
    Text: 7.5 kV Kilovac KM-13 Part Number Features: Make Only Load Switching • Highly reliable SF-6 gas-filled relay for capacitive discharge applications • Widely used as heart defibrillator patient relay • Double pole, double throw contacts PRODUCT SPECIFICATIONS


    Original
    KM-13 kilovac km13 defibrillator kilovac CII Technologies relay defibrillator circuits Gas discharge 265VDC PDF

    t48 diode

    Abstract: PLC coupling transformer transformer oil tu marking T43D T43KU T44D T44KU T48D
    Text: High Voltage Precision Thick Film Resistors Welwyn Components T Series • Working voltage up to 100kV • Resistances up to 50G • TCR down to 25ppm • Termination variants • Sets of resistors with matched characteristics Electrical Data T43 T44 T48 Power rating at 20°C


    Original
    100kV 25ppm 250ppm/ IEC62 20/box 100ppm/ 25ppm/ t48 diode PLC coupling transformer transformer oil tu marking T43D T43KU T44D T44KU T48D PDF

    ku 202

    Abstract: IEC 62 code RESISTOR
    Text: High High Voltage VoltagePrecision Precision Thick ThickFilm FilmResistors Resistors Welwyn Components T Series T Series Working voltage up to 100kV s Working Resistances voltage up to 50G up to 100kV up25ppm to 50G s Resistances TCR down to down tovariants


    Original
    100kV 25ppm IEC62 20/box 100ppm/ 25ppm/ ku 202 IEC 62 code RESISTOR PDF

    KC-28

    Abstract: KC-32 KC-38 KC-22 discharge vacuum
    Text: 25 kV Kilovac KC-22, KC-32 Features: Make & Break Load Switching KC-22 • Tungsten contacts for power switching • Vacuum dielectric for arc suppression when making or breaking a load • No contact oxidation from arcing KC-32 • Normally closed version of KC-22


    Original
    KC-22, KC-32 KC-22 KC-28, KC-38 KC-28 KC-28 KC-32 KC-38 KC-22 discharge vacuum PDF

    Untitled

    Abstract: No abstract text available
    Text: METALLUX E L E C T R O N I C 3000 Precision Resistors-Networks “Special Applications” PräzisionsWiderstands-Netzwerke “Spezielle Applikationen” Serie 3000 specially for custom design. Resistor range 500 Ohm to 500 Mohm. Ceramic dimensions and pin-out can be adjusted to


    Original
    CH-6850 CH-8954 PDF

    Untitled

    Abstract: No abstract text available
    Text: Resistors High Voltage Precision High Precision ThickVoltage Film Resistors Thick Film Resistors Make Possible Welwyn Components T Series Ts Series Working voltage up to 100kV s s s s Resistances up up to to 50G Working voltage 100kV TCR down up to to 25ppm


    Original
    100kV 25ppm Termination25ppm 2011/65/EU IEC62 20/box 100ppm/Â 25ppm/Â PDF

    CH-8954

    Abstract: No abstract text available
    Text: METALLUX E L E C T R O N I C 969 Non Inductive High Voltage Resistors “Precision” Induktionsfreie Hochspannungs-Widerstände “Precision” This serie of resistors is intended for use in voltage dividers, medical equipments, electrostatic devices and


    Original
    CH-6850 CH-8954 PDF

    Untitled

    Abstract: No abstract text available
    Text: _n « c THE RESISTOR PEOPLE HIGH VOLTAGE PRECISION THICK FILM RESISTORS Insulating Sleeve T SERIES* • • • • • • • • Working voltage up to 100KV Wide resistance range Low temperature coefficient of resistance Low voltage coefficient Termination variants


    OCR Scan
    100KV T44KUH 50ppm/Â PDF