60Co
Abstract: No abstract text available
Text: CHAPTER 7 SCINTILLATION COUNTING Radiation of various types is widely utilized for non-destructive inspection and testing such as in medical diagnosis, industrial inspection, material analysis and other diverse fields. In such applications, radiation detectors play an important role. There are various methods
|
Original
|
NS-33
60Co
|
PDF
|
R1306
Abstract: r11265u-20 HAMAMATSU R647 R8900-00-M16 R8997
Text: PHOTOMULTIPLIER TUBES AND ASSEMBLIES PHOTOMULTIPLIER TUBES AND ASSEMBLIES WEB SITE www.hamamatsu.com INTRODUCTION In radiation measurements, scintillation counters which are combinations of scintillators and photomultiplier tubes are used as most common and useful devices in detecting X-, alpha-, beta-, gamma-rays and other high energy charged particles. A scintillator
|
Original
|
RU-127015,
TPMO0007E03
R1306
r11265u-20
HAMAMATSU R647
R8900-00-M16
R8997
|
PDF
|
Untitled
Abstract: No abstract text available
Text: CHAPTER 13 ENVIRONMENTAL RESISTANCE AND RELIABILITY Photomultiplier tube characteristics, for example, sensitivity and dark current, are susceptible to environmental conditions such as ambient temperature, humidity and magnetic fields. To obtain the fullest
|
Original
|
|
PDF
|
circuit diagram blood gas analyzer
Abstract: Light Detector laser
Text: CHAPTER 14 APPLICATIONS Photomultiplier tubes PMTs are extensively used as photodetectors in fields such as chemical analysis, medical diagnosis, scientific research and industrial measurement. This chapter introduces major applications of photomultiplier tubes and describes the principle and
|
Original
|
|
PDF
|
proton rx 4000 watts power amplifier circuit diagram
Abstract: Hamamatsu r300 0812E H5783
Text: PHOTOMULTIPLIER TUBES Basics and Applications THIRD EDITION Edition 3a PHOTON IS OUR BUSINESS 2007 HAMAMATSU PHOTONICS K. K. ▲ Photomultiplier Tubes ▲ Photomultiplier Tube Modules © 2007 HAMAMATSU PHOTONICS K. K. Introduction Light detection technolgy is a powerful tool that provides deeper understanding of more sophisticated
|
Original
|
OTH9001E03a
proton rx 4000 watts power amplifier circuit diagram
Hamamatsu r300
0812E
H5783
|
PDF
|
Untitled
Abstract: No abstract text available
Text: CHAPTER 4 CHARACTERISTICS OF PHOTOMULTIPLIER TUBES This chapter details various characteristics of photomultiplier tubes, including basic and performance. For example, section 4.1 shows spectral response characteristics of typical photocathodes and also gives
|
Original
|
NS-14
|
PDF
|
662k
Abstract: ortec 464 14120-01-445 ortec C4065 tube radiology TPMHC0158EA scintillation radiation detector R2487-02 R2487-05
Text: POSITION-SENSITIVE PHOTOMULTIPLIER TUBES WITH CROSSED WIRE ANODES R2487 SERIES 3˝ x 3˝ Square Envelope Position-Sensitive PMT with Crossed Wire Anodes For Nuclear Medical Instrument, High Energy Physics Experiments TPMHF0049 Introduction Applications The R2487 series have a bialkali photocathode, a 12-stage
|
Original
|
R2487
TPMHF0049
12-stage
S-164-40
TPMH1207E01
662k
ortec 464
14120-01-445
ortec
C4065
tube radiology
TPMHC0158EA
scintillation radiation detector
R2487-02
R2487-05
|
PDF
|
Application Papers
Abstract: No abstract text available
Text: Databook.fxp 1/13/99 2:10 PM Page H-13 H-13 01/99 Titles of Device Application Papers Abstracts and complete text available from InterFET upon request JFET for Completely Depleted High Resistivity Silicon V. Radeka, P. Rehak, S. Rescia Brookhaven National
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Si PI N photodiode S3590-08/-09/-18/-19 Large active area Si PI N photodiode Features Applications Sensitivity matching w ith BGO and CsI TI scintillators: S3590-08/ -09 Scintillation detectors Hodoscopes Sensitivity matching w ith blue scintillator ( LSO, GSO, etc.) :
|
Original
|
S3590-08/-09/-18/-19
S3590-08/
S3590-18/
S3590-09/
S3590-09
S3590-19
S3590-08
S3590-18
|
PDF
|
14120-01-445
Abstract: ortec 464 ortec preamplifier ortec 533 IC 741 AMP DATASHEET ortec position sensitive diode AH tube MARK X5 scintillation radiation detector
Text: POSITION-SENSITIVE PHOTOMULTIPLIER TUBES WITH CROSSED WIRE ANODES R2486 SERIES 3˝ Diameter Circular Envelope Position-Sensitive PMT with Crossed Wire Anodes For Nuclear Medical Instruments, High Energy Physics Experiments Introduction Applications The R2486 series have a bialkali photocathode, a 12-stage
|
Original
|
R2486
12-stage
R3292
SE-171-41
TPMH1206E02
14120-01-445
ortec 464
ortec preamplifier
ortec 533
IC 741 AMP DATASHEET
ortec
position sensitive diode
AH tube
MARK X5
scintillation radiation detector
|
PDF
|
PIN Photodiode
Abstract: S3590-19 Si PIN PHOTODIODE S3590-08
Text: Si PIN photodiode S3590-08/-09/-18/-19 Large active area Si PIN photodiode Features Applications Sensitivity matching with BGO and CsI TI scintillators: S3590-08/-09 Scintillation detectors Sensitivity matching with blue scintillator (LSO, GSO, etc.): S3590-18/-19
|
Original
|
S3590-08/-09/-18/-19
S3590-08/-09
S3590-18/-19
S3590-09/-19
S3590-09
S3590-19
S3590-08
S3590-09
S3590-18
S3590-19
PIN Photodiode
Si PIN PHOTODIODE
|
PDF
|
block diagram of positron emission tomography imaging system
Abstract: block diagram of ultrasound computed tomography MAX19526 MAX19515 MAX4104 MAX4223 MAX4224 MAX4225 MAX4226 MAX9601
Text: Maxim > App Notes > A/D and D/A Conversion/Sampling Circuits Amplifier and Comparator Circuits Keywords: PET, positron emission tomography, medical imaging, medical scan, 3-D medical, gamma rays, photon, electrical components for medical May 10, 2010 APPLICATION NOTE 4680
|
Original
|
MAX9600:
MAX9601:
MAX9602:
com/an4680
AN4680,
APP4680,
Appnote4680,
block diagram of positron emission tomography imaging system
block diagram of ultrasound computed tomography
MAX19526
MAX19515
MAX4104
MAX4223
MAX4224
MAX4225
MAX4226
MAX9601
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Si PIN photodiode S3590-08/-09/-18/-19 Large active area Si PIN photodiode Features Applications Sensitivity matching with BGO and CsI TI scintillators: S3590-08/-09 Scintillation detectors Sensitivity matching with blue scintillator (LSO, GSO, etc.): S3590-18/-19
|
Original
|
S3590-08/-09/-18/-19
S3590-08/-09
S3590-18/-19
S3590-09/-19
S3590-09
S3590-19
S3590-08
S3590-09
S3590-18
S3590-19
|
PDF
|
large area quadrant photodiode
Abstract: quadrant avalanche photodiode 4-element linear photodetector
Text: 204-74-74-561 Quadrant LAAPD Array The 204-74-74-561 is a highly sensitive 4-element array photodetector, built on the basis of the API proprietary Large Area Avalanche Photodiode technology. Advanced micromachining techniques have been implemented for the element pixelization, thus
|
Original
|
|
PDF
|
|
geiger apd
Abstract: SPMMicro3035x13 geiger tube Geiger photomultiplier SPMMicro1020X13 SPMMicro6035X13 helium gas sensor module PDF PIN APD DIODE DESCRIPTION pulse metal detector
Text: SPMMicro Series High Gain APD SPMMicro detectors come in a variety of pin package formats Overview according to footprint requirements, levels of hermeticity, and cooling. These include glass/metal sealed transistor header package types TO46, TO5, TO8 and ceramic packages (TO5
|
Original
|
MIL-STD-750,
1x10-8
geiger apd
SPMMicro3035x13
geiger tube
Geiger
photomultiplier
SPMMicro1020X13
SPMMicro6035X13
helium gas sensor module
PDF PIN APD DIODE DESCRIPTION
pulse metal detector
|
PDF
|
R1306
Abstract: c7319 R720501 HAMAMATSU E849 e717-63 R928, hamamatsu
Text: Photomultiplier Tubes PHOTOMULTIPLIER TUBES AND RELATED PRODUCTS Opening The Future with Photonics Human beings obtain more than 70 percent of the information visually by using their eyes. However, there are vast sums of information and unknown possibilities hidden within light not visible to the naked eye. This kind of light
|
Original
|
B-1348
E-08290
TPMZ0001E01
R1306
c7319
R720501
HAMAMATSU E849
e717-63
R928, hamamatsu
|
PDF
|
ultrasonic 40 khz transducer
Abstract: RCA photomultiplier mk-109 Ultrasonic Transducer application notes ultrasonic transducer excitation circuit lvdt accelerometer Schaevitz accelerometer lvdt accelerometer sensor ultrasonic transducer drive circuits LVDT strain gauge displacement transducer
Text: A substantial amount of information is available on signal conditioning for common transducers. Fortunately, most of these devices, which are used to sense common physical parameters, are relatively easy to signal condition. Further, most transducer-based measurement requirements are well
|
Original
|
LF412
LM329
AN-301
ultrasonic 40 khz transducer
RCA photomultiplier
mk-109
Ultrasonic Transducer application notes
ultrasonic transducer excitation circuit
lvdt accelerometer
Schaevitz accelerometer
lvdt accelerometer sensor
ultrasonic transducer drive circuits
LVDT strain gauge displacement transducer
|
PDF
|
S11108
Abstract: C11208-01 C8841 H10570 Hamamatsu Photonics S11108 External Quantum Efficiency solar
Text: NEWS 02 2009 LASER PRODUCTS PAGE 08 Gas detection: New Quantum Cascade Infrared Lasers SOLID STATE PRODUCTS PAGE 18 Infrared LED L10822, L10822-01, L10823, L10823-01 ELECTRON TUBE PRODUCTS PAGE 37 Flat panel PMT assemblies H10966A-100/H10966B-100 SYSTEMS PRODUCTS
|
Original
|
L10822,
L10822-01,
L10823,
L10823-01
H10966A-100/H10966B-100
C11079-01
S11108
C11208-01
C8841
H10570
Hamamatsu Photonics S11108
External Quantum Efficiency solar
|
PDF
|
RCA photomultiplier
Abstract: 2n2222 h 331 mk-109 ultrasonic 40 khz transducer ultrasonic transducer excitation circuit ultrasonic transducer drive circuits Schaevitz accelerometer MK109 schematic ultrasonic distance meter LVDT sensor for aerospace
Text: National Semiconductor Application Note 301 January 1982 A substantial amount of information is available on signal conditioning for common transducers Fortunately most of these devices which are used to sense common physical parameters are relatively easy to signal condition Further
|
Original
|
|
PDF
|
AIR FLOW DETECTOR FULL REPORT
Abstract: electronic rolling display automatic heat detector report Nitrogen Relief Valve motor operated valve limit switch scintillation radiation detector diagram of flow chart of water level control OKC-20A pressure reducing valve air Cesium-137
Text: TOSGAGE Series Cesium Thickness Gage TOSGAGE -141S General The TOSGAGE 141S Cesium Thickness Gage is used for rougher stands on plate mills and hot strip mills. It is also installed on thick plate shear lines to ensure uniform quality, improve yields and increase rolling
|
Original
|
-141S
Cs-137)
EJD-012K
OSGAGE-141S
AIR FLOW DETECTOR FULL REPORT
electronic rolling display
automatic heat detector report
Nitrogen Relief Valve
motor operated valve limit switch
scintillation radiation detector
diagram of flow chart of water level control
OKC-20A
pressure reducing valve air
Cesium-137
|
PDF
|
OSD35-LR-D
Abstract: centronic photodiodes Centronic OSD35-LR-C 5902 OSD35-LR-A OSD35-LR-B OSD35LR-C
Text: OSD35-LR Low Light Level Sensors Centronic low light level sensors are special large area silicon photodiodes 35mm2 designed for circuits requiring a very high shunt resistance. These photodiodes are used with scintillation crystals for radiation detectors and for
|
OCR Scan
|
OSD35-LR
35mm2)
OSD35-LR
900nm
OSD35-LR-A
OSD35-LR-B
OSD35-LR-C
OSD35-LR-D
centronic photodiodes
Centronic
5902
OSD35LR-C
|
PDF
|
Centronic
Abstract: OSD35-LR-D OSD35-LR-A OSD35-LR-B 5902 OSD35-LR-C
Text: CENTRONIC IN C t E-0 bEE » IV D mSSSD 000D4Ö4 Ô47 • CENB OSD35-LR Low Light Level Sensors Centronic low light level sensors are special large area silicon photodiodes 35mm2 designed for circuits requiring a very high shunt resistance. These photodiodes are used with scintillation crystals for radiation detectors and for
|
OCR Scan
|
OSD35-LR
35mm2)
OSD35-LR
900nm
OSD35-LR-A
OSD35-LR-B
OSD35-LR-C
Centronic
OSD35-LR-D
5902
|
PDF
|
S2662-01
Abstract: S3204-03 L627 S3590-03 S1790
Text: Large-Area PIN Silicon Photodiodes FEATURES Silicon photodiodes are promising devices for scintillation detec • Large active area: 10 X 10 mm, 10 X 20 mm, 30 X 30mm, etc. • High quantum efficiency • Low dark current • Low bias voltage operation • Sensitivity matching with BGO scintillators
|
OCR Scan
|
|
PDF
|
silizium diode
Abstract: scintillation radiation detector SFH 873 radiation detector chip sfh 520
Text: Technische Erläuterungen SIEMENS u-p-y-Strahlungsdetektoren Für die M essung hochenergetischer Strahlung hat Siem ens sein Fotodiodenspektrum um Teilchendetektoren erweitert. Es stehen Detektoren mit vier verschiedenen aktiven Flächen SFH 520 bis SFH 523 auf einer kleinen Leiterplatte zur Verfügung. Die Detektoren sind auch als
|
OCR Scan
|
F02250
silizium diode
scintillation radiation detector
SFH 873 radiation detector chip
sfh 520
|
PDF
|