Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    SAFE FLAME Search Results

    SAFE FLAME Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    Safety-Light-Curtain Renesas Electronics Corporation Safety Light Curtain Reference Design Visit Renesas Electronics Corporation
    R7F701201EABG Renesas Electronics Corporation Safe and Secure High-end Microcontroller for Powertrain Visit Renesas Electronics Corporation
    R7F701205EAFP Renesas Electronics Corporation Safe and Secure High-end Microcontroller for Powertrain Visit Renesas Electronics Corporation
    R7F701205EABG#AC0 Renesas Electronics Corporation Safe and Secure High-end Microcontroller for Powertrain Visit Renesas Electronics Corporation
    R7F701201EAFA Renesas Electronics Corporation Safe and Secure High-end Microcontroller for Powertrain Visit Renesas Electronics Corporation

    SAFE FLAME Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Untitled

    Abstract: No abstract text available
    Text: ALUMINUM ELECTROLYTIC CAPACITORS RoHS ü LS2 Series: Snap-In, Fail Safe, 85°C FEATURES • Snap-in, 2000 Hrs, 85°C • Fail-Safe, will fail open without flame if excessive voltage is applied • RoHS Compliant SPECIFICATIONS Items Operating Temperature Range


    Original
    PDF 120Hz, 120Hz) C1CH03

    SF810

    Abstract: EN854 uv flame sensor safe flame dfs SF810-FO-Q-XXXX-mm flame scanner icepi 10 ATEX 03c024 84410-S-0400001 SiC Photodiodes C99-94510
    Text: System 800xA for Power Generation Uvisor SF810 Multi Fuel Safe Flame Scanner 800 Series Combustion Instruments ABB has combined the two highly successful flame scanner product lines, Uvisor™ and Safe Flame DFS, into a new advanced Flame Scanner, the Uvisor™


    Original
    PDF 800xA SF810 SF810. SF810 EN854 ND-19 EN854 84410-S-0400001 ND-25 uv flame sensor safe flame dfs SF810-FO-Q-XXXX-mm flame scanner icepi 10 ATEX 03c024 84410-S-0400001 SiC Photodiodes C99-94510

    SF810

    Abstract: safe flame dfs uv flame sensor 9AKK101130D4742 UV LED 280NM SF810I SF810-FO-Q-XXXX-mm C99-94510 EN854 steam boiler ignitor
    Text: System 800xA for Power Generation Uvisor SF810i Multi Fuel Integrated Safe Flame Scanner 800 Series Combustion Instruments ABB has combined the two highly successful flame scanner product lines, Uvisor™ and Safe Flame DFS, into a new advanced Flame Scanner, the Uvisor™


    Original
    PDF 800xA SF810i SF810i. SF810i EN854 84410-S-0400000 84410-S-0400001 84410-S-0400002 9AKK101130D4742-M- SF810 safe flame dfs uv flame sensor 9AKK101130D4742 UV LED 280NM SF810-FO-Q-XXXX-mm C99-94510 steam boiler ignitor

    cables

    Abstract: No abstract text available
    Text: CABLES - CAVI MN-NE MN-NK PVC, intrinsically safe apparatus PVC, impianti sicurezza intrinseca Description. Conductor insulation: special PVC. Outer sheath: special PVC. Application. Cables used in explosion risk area “i” IEC 60079-11 Intrisically Safe are blue


    Original
    PDF 0332-3A. bu5015 cables

    Untitled

    Abstract: No abstract text available
    Text: Cable solutions to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE MAY 2013 GENERAL C ABL E DEL IVERS Advanced Reliability, Safety And Sustainability To The Nuclear Power Industry Safe, Reliable Cable Solutions for Safe, Reliable Operation


    Original
    PDF 60-year-plus ultrol60+ x8726 INS-0153-0513

    digital ohmmeter circuit diagram

    Abstract: No abstract text available
    Text: Intrinsically Safe Outputs Made Easy Part 5 of this series explains how to make solenoid valves, LED’s, and I/P transducers intrinsically safe. HAZARDOUS SIDE CLASS I, II, III DIVISION 1 GROUPS A-G NON-HAZARDOUS SIDE + 24 V + + + Digital Output D/O Solenoid


    Original
    PDF Z-148 digital ohmmeter circuit diagram

    S69B

    Abstract: S67B
    Text: LM5068 www.ti.com SNVS254B – MAY 2004 – REVISED DECEMBER 2004 LM5068 Negative Voltage Hot Swap Controller Check for Samples: LM5068 FEATURES 1 • 2 • • • • • • • Safe module insertion and removal from live backplanes In-rush current limiting for safe board


    Original
    PDF LM5068 SNVS254B LM5068 S69B S67B

    olflex cables catalogue

    Abstract: No abstract text available
    Text: ÖLFLEX EB CY FIO Catalogue Description: Lapp Olflex Screened Intrinsically Safe Control Cables ÖLFLEX® EB CY is a Screened PVC control cable with a blue outer sheath for use in explosive atmosphere with hazard type “i” intrinsically safe . Complies with DIN EN 60079-14 section


    Original
    PDF 811-X 73/23/EEC olflex cables catalogue

    Untitled

    Abstract: No abstract text available
    Text: SN75276 FAIL-SAFE DIFFERENTIAL BUS TRANSCEIVER SLLS212B – SEPTEMBER 1995 – REVISED APRIL 1998 D D D D D D D D D D D D D D D OR P PACKAGE TOP VIEW Bidirectional Transceiver With Fail-Safe Receiver Meets or Exceeds the Requirements of ITU Recommendation V.11


    Original
    PDF SN75276 SLLS212B TIA/EIA-422-B TIA/EIA-485-A

    1N916

    Abstract: SN75172 SN75173 SN75174 SN75175 SN75176A SN75276
    Text: SN75276 FAIL-SAFE DIFFERENTIAL BUS TRANSCEIVER SLLS212B – SEPTEMBER 1995 – REVISED APRIL 1998 D D D D D D D D D D D D D D D OR P PACKAGE TOP VIEW Bidirectional Transceiver With Fail-Safe Receiver Meets or Exceeds the Requirements of ITU Recommendation V.11


    Original
    PDF SN75276 SLLS212B TIA/EIA-422-B TIA/EIA-485-A 1N916 SN75172 SN75173 SN75174 SN75175 SN75176A SN75276

    Untitled

    Abstract: No abstract text available
    Text: SN75276 FAIL-SAFE DIFFERENTIAL BUS TRANSCEIVER SLLS212B – SEPTEMBER 1995 – REVISED APRIL 1998 D D D D D D D D D D D D D D D OR P PACKAGE TOP VIEW Bidirectional Transceiver With Fail-Safe Receiver Meets or Exceeds the Requirements of ITU Recommendation V.11


    Original
    PDF SN75276 SLLS212B TIA/EIA-422-B TIA/EIA-485-A

    1N916

    Abstract: SN75172 SN75173 SN75174 SN75175 SN75176A SN75276
    Text: SN75276 FAIL-SAFE DIFFERENTIAL BUS TRANSCEIVER SLLS212B – SEPTEMBER 1995 – REVISED APRIL 1998 D D D D D D D D D D D D D D D OR P PACKAGE TOP VIEW Bidirectional Transceiver With Fail-Safe Receiver Meets or Exceeds the Requirements of ITU Recommendation V.11


    Original
    PDF SN75276 SLLS212B TIA/EIA-422-B TIA/EIA-485-A 1N916 SN75172 SN75173 SN75174 SN75175 SN75176A SN75276

    Untitled

    Abstract: No abstract text available
    Text: SN75276 FAIL-SAFE DIFFERENTIAL BUS TRANSCEIVER SLLS212B – SEPTEMBER 1995 – REVISED APRIL 1998 D D D D D D D D D D D D D D D OR P PACKAGE TOP VIEW Bidirectional Transceiver With Fail-Safe Receiver Meets or Exceeds the Requirements of ITU Recommendation V.11


    Original
    PDF SN75276 SLLS212B TIA/EIA-422-B TIA/EIA-485-A

    1N916

    Abstract: SN75172 SN75173 SN75174 SN75175 SN75176A SN75276 EIA-485-A
    Text: SN75276 FAIL-SAFE DIFFERENTIAL BUS TRANSCEIVER SLLS212B – SEPTEMBER 1995 – REVISED APRIL 1998 D D D D D D D D D D D D D D D OR P PACKAGE TOP VIEW Bidirectional Transceiver With Fail-Safe Receiver Meets or Exceeds the Requirements of ITU Recommendation V.11


    Original
    PDF SN75276 SLLS212B TIA/EIA-422-B TIA/EIA-485-A 1N916 SN75172 SN75173 SN75174 SN75175 SN75176A SN75276 EIA-485-A

    Untitled

    Abstract: No abstract text available
    Text: SN75276 FAIL-SAFE DIFFERENTIAL BUS TRANSCEIVER SLLS212B – SEPTEMBER 1995 – REVISED APRIL 1998 D D D D D D D D D D D D D D D OR P PACKAGE TOP VIEW Bidirectional Transceiver With Fail-Safe Receiver Meets or Exceeds the Requirements of ITU Recommendation V.11


    Original
    PDF SN75276 SLLS212B TIA/EIA-422-B TIA/EIA-485-A

    Untitled

    Abstract: No abstract text available
    Text: Cement Thermal Fusible Resistors Features: • • • • • Self Extinguishing Extremely small and mechanically safe Excellent flame and moisture resistance Provides outstanding feature against surges Very low or Very high ohmic values available upon request


    Original
    PDF

    TF01S

    Abstract: 4k resistor 50w TF01
    Text: PRECISION FAILSAFE THERMAL - FUSE RESISTORS CUSTOM DESIGN - 1/2 WATT to 60 WATT RESISTORS wCAPS & COILS wDELAY LINES 6.5-41-5 FEATURES The ultimate failsafe design! r Intrinsically safe, completely flameproof. Component opens without hazard of overheating.


    Original
    PDF

    PFAC35

    Abstract: PF7A l2525
    Text: Cement Thermal Fusible Resistors Features Self-Extinguishing Extremely small and mechanically safe Excellent flame and moisture resistance Provides outstanding feature against surges Too low or too high ohmic values can be supplied on a case-to-case basis


    Original
    PDF PF3A15 PF3B20 PF5A16 PF5B21 PF7A22 PF7B27 PFAC35 PFAC35 PF7A l2525

    Untitled

    Abstract: No abstract text available
    Text: Chip tantalum capacitors Fail-safe open structure type TCFG Series B Case Datasheet Features 1) Open structure built in for superior flame retardance characteristics. 2) Advanced wire bonding technology enable to make compact packages. 3) Eco-friendly halogen-free products.


    Original
    PDF R1102A

    erf150w

    Abstract: No abstract text available
    Text: Wirewound Resistors, Flameproof, Bath-tub Type Wirewound Resistors, Flameproof, Bath-tub Type High Power with Aluminum Case Type Type: ERF२२२W ERF60W, ERF100W, ERF150W, ERF200W • Features ● Flameproof . Made from nonflammable materials, making the resistor very safe.


    Original
    PDF ERF60W, ERF100W, ERF150W, ERF200W erf150w

    Untitled

    Abstract: No abstract text available
    Text: Wirewound Resistors, Flameproof, Bath-tub Type Wirewound Resistors, Flameproof, Bath-tub Type High Power with Aluminum Case Type Type: ERF□□□W ERF60W, ERF100W, ERF150W, ERF200W • Features ● Flameproof . Made from nonflammable materials, making the resistor very safe.


    Original
    PDF ERF60W, ERF100W, ERF150W, ERF200W

    circuit diagram of ultrasonic flow meter

    Abstract: DIN 50049 turbine meter ultrasonic flow meter magnetic flow meter circuit diagram FLOW METER turbine ultrasonic water flow meter magnetic flow meter turbine MR-01-75
    Text: Turbine Meter Model PTF Specification DataFile •■ Wide flow range – up to 40:1 ■■ Intrinsically Safe and Flameproof versions available – increases range of applications ■■ Excellent linearity and repeatability – meets fiscal metering standards


    Original
    PDF 284m3/h MR-01-75 circuit diagram of ultrasonic flow meter DIN 50049 turbine meter ultrasonic flow meter magnetic flow meter circuit diagram FLOW METER turbine ultrasonic water flow meter magnetic flow meter turbine

    Untitled

    Abstract: No abstract text available
    Text: Wirewound Resistors, Flame Proof Coatin iNTacawenoN The KNP series resistors are fabricated using a fibreglass or ceramic core with the resistance wire securely crimped to the terminals. FEATURES Exceptionally small, sturdy and mechanically safe. Excellent electrical characteristics.


    OCR Scan
    PDF RS-344 RC-649. MIL-STD-202F, MIL-R-55342E, UL-1412

    Untitled

    Abstract: No abstract text available
    Text: r WIREWOUND RESISTORS RECTANGULAR LRW STANDARD TYPE FEATURES DERATING CURVE 1. Exceptionally sm all and sturdy; m echanically safe. Excellent electrical characteristics. 2. The m a te rials used and the co n stru ctio n techniques ensure excellent flame resistance,


    OCR Scan
    PDF RS-344 RC-649. LRW-20