Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    RELAY NORMAL OPEN Search Results

    RELAY NORMAL OPEN Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TCTH022BE Toshiba Electronic Devices & Storage Corporation Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type / FLAG signal latch function Visit Toshiba Electronic Devices & Storage Corporation
    TCTH021BE Toshiba Electronic Devices & Storage Corporation Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type Visit Toshiba Electronic Devices & Storage Corporation
    TCTH012BE Toshiba Electronic Devices & Storage Corporation Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=1μA / IDD=1.8μA / Open-drain type / FLAG signal latch function Visit Toshiba Electronic Devices & Storage Corporation
    TCTH011BE Toshiba Electronic Devices & Storage Corporation Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=1μA / IDD=1.8μA / Open-drain type Visit Toshiba Electronic Devices & Storage Corporation
    LBAA0QB1SJ-295 Murata Manufacturing Co Ltd SX1262 MODULE WITH OPEN MCU Visit Murata Manufacturing Co Ltd

    RELAY NORMAL OPEN Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    relay vde 0435 VDE 0110

    Abstract: VDE 0435 time relay time relay vde 0435 VDE 0110 group C relay vde 0435 IEC60255 DIN VDE 0110 0435 relay vde VDE 0160 vde 0435 vde 0110 EN 50155 vde 0435 0110
    Text: Data sheet from 20.06.2012 Item no.: 859-398 Product description: Rail-mounted terminal block with miniature switching relay RELAY WITH 1 CHANGEOVER CONTACT 1u WITH MINIATURE SWITCHING RELAY FOR NORMAL SWICHING POWER RELAY WITH 4 MAKE CONTACTS AND 4 BREAK


    Original
    IEC60255; relay vde 0435 VDE 0110 VDE 0435 time relay time relay vde 0435 VDE 0110 group C relay vde 0435 IEC60255 DIN VDE 0110 0435 relay vde VDE 0160 vde 0435 vde 0110 EN 50155 vde 0435 0110 PDF

    G8FD-2SF

    Abstract: G8ND 2S g8fd G8ND DUAL H-bridge relay connections
    Text: G8FD Automotive PCB relay Dual H-Bridge Compact, general-purpose relay that to control the normal and reverse of the motor. 65% downsized from standard G8ND. (Surface mount type is available) • 8-terminal dual relay. Separate coil and contact PCB Relay


    Original
    PDF

    time relay vde 0435 VDE 0110 group C

    Abstract: No abstract text available
    Text: Data sheet from 20.06.2012 Item no.: 859-314 Product description: Rail-mounted terminal block with miniature switching relay RELAY WITH 1 CHANGEOVER CONTACT 1u WITH MINIATURE SWITCHING RELAY FOR NORMAL SWICHING POWER CONTACT MATERIAL 5µm Au GOLD PLATED


    Original
    TE/1717/880590/08 DK-7574 E175199 time relay vde 0435 VDE 0110 group C PDF

    relay vde 0435 VDE 0110

    Abstract: vde 0435 vde 0110 VDE 0110 0435
    Text: 1 JUMPFLEX Relay Socket with Miniature Switching Relay 50 <_ 81 mm/3.18 in _> 857-304 Relay with 1 changeover contact 1u for normal switching power Nominal input voltage VN 24 V, 115 V, 230 V AC/DC <_ 81 mm/3.18 in _> Relay with 1 changeover contact (1u)


    Original
    D-32385 D-32423 relay vde 0435 VDE 0110 vde 0435 vde 0110 VDE 0110 0435 PDF

    relay vde 0435 VDE 0110

    Abstract: No abstract text available
    Text: 1 Relay Socket with Miniature Switching Relay 50 857-354 <_ 81 mm/3.18 in _> 857-304 Relay with 1 changeover contact 1u for normal switching power Nominal input voltage VN 24 V, 115 V, 230 V AC/DC <_ 81 mm/3.18 in _> Relay with 1 changeover contact (1u)


    Original
    D-32385 D-32423 relay vde 0435 VDE 0110 PDF

    relay vde 0435 VDE 0110

    Abstract: No abstract text available
    Text: 1 JUMPFLEX Relay Socket with Miniature Switching Relay 50 <_ 81 mm/3.18 in _> 857-304 Relay with 1 changeover contact 1u for normal switching power Nominal input voltage VN AC/DC 24 V, 115 V, 230 V <_ 81 mm/3.18 in _> Relay with 1 changeover contact (1u)


    Original
    D-32385 D-32423 relay vde 0435 VDE 0110 PDF

    relay vde 0435 VDE 0110

    Abstract: No abstract text available
    Text: 1 JUMPFLEX Relay Socket with Miniature Switching Relay 51 Relay with 1 changeover contact 1u (gold contacts) for normal switching power Nominal input voltage VN DC 24 V, 110 V, 220 V 1 <_ 81 mm/3.18 in _> <_ 81 mm/3.18 in _> 857-314


    Original
    D-32385 D-32423 relay vde 0435 VDE 0110 PDF

    24DC

    Abstract: No abstract text available
    Text: Voltage Sensitive Relays WILMAR Protective Relays – WUV/WOV DC Series Function: • ANSI/IEEE C37.90-1978 Undervoltage Models - The relay is energized at normal voltage, N.C. contacts will open and N.O. contacts will close. The relay will de-energize when


    Original
    125DC 240DC 250DC 305DC 405DC 430DC 470DC 560DC 120DC WOV-12DC-A 24DC PDF

    Le79489

    Abstract: No abstract text available
    Text: Le79489 Subscriber Line Interface Circuit Ve580 Series DISTINCTIVE CHARACTERISTICS „ Low standby power normal and reverse „ On-chip ring and test relay drivers and relay snubber circuits „ Automatic on-chip battery switching „ Polarity reversal (full transmission)


    Original
    Le79489 Ve580 Le79489 PDF

    LE79489JC

    Abstract: schematic diagram induction heating RFI filter schematic diagram JESD22 CVBAT12 Le79489 ve58
    Text: Le79489 Subscriber Line Interface Circuit Ve580 Series DISTINCTIVE CHARACTERISTICS „ Low standby power normal and reverse „ On-chip ring and test relay drivers and relay snubber circuits „ Automatic on-chip battery switching „ Polarity reversal (full transmission)


    Original
    Le79489 Ve580 Le79489 LE79489JC schematic diagram induction heating RFI filter schematic diagram JESD22 CVBAT12 ve58 PDF

    Omron g8nd-27ur

    Abstract: G8nd27r G8ND-27 G8ND-27R g8nd27ur g8nd 27ur g8nd-2 automotive relay G8ND-27UR omron door lock relay DUAL H-bridge
    Text: G8ND Automotive PCB relay Dual H-Bridge For normal/reverse rotation motor control • 8-terminal dual relay. Separate coil and contact terminals. • Compact size but its power contacts and heatrelease design achieved a high current switching. • Purpose


    Original
    PDF

    Le79489

    Abstract: JESD22 MS-016 VBAT14
    Text: Le79489 Subscriber Line Interface Circuit Ve580 Series DISTINCTIVE CHARACTERISTICS „ Low standby power normal and reverse „ On-chip ring and test relay drivers and relay snubber circuits „ Automatic on-chip battery switching „ Polarity reversal (full transmission)


    Original
    Le79489 Ve580 Le79489 JESD22 MS-016 VBAT14 PDF

    LE79489JC

    Abstract: MS-016 JESD22 relay snubber legerity LE loop detector
    Text: Le79489 A Subscriber Line Interface Circuit Ve580 Series Voice Solution DISTINCTIVE CHARACTERISTICS „ Low standby power normal and reverse „ On-chip ring and test relay drivers and relay snubber circuits „ Automatic on-chip battery switching „ Polarity reversal (full transmission)


    Original
    Le79489 Ve580 LE79489JC MS-016 JESD22 relay snubber legerity LE loop detector PDF

    relay dur2

    Abstract: 11-pin relay pin out diagram as 893 m 11 pin 24 AC relay 24 v DC relay 14 pin relay datasheet 48 voltage DC relay dur2 relay 112 relay 8 pin
    Text: Voltage control relay • ■ ■ ■ ■ DUR2/LUR2 Controls AC and DC voltages 0.5 V to 600 RMS measurement range Threshold and hysteresis separately adjustable Normal or reverse relay selection by switch on front face Time-out of high threshold overrun adjustable from


    Original
    11-pin relay dur2 11-pin relay pin out diagram as 893 m 11 pin 24 AC relay 24 v DC relay 14 pin relay datasheet 48 voltage DC relay dur2 relay 112 relay 8 pin PDF

    Untitled

    Abstract: No abstract text available
    Text: Relay with 1 changeover contact 1u defined turn-on/turn-off threshold for normal switching power Nominal input voltage VN 230 VAC Relay with 1 changeover contact (1u) with an extended Input voltage range: VN -30 % . +25 % Operating temperature range: -25 °C . +70 °C


    Original
    D-32385 D-32423 PDF

    relay vde 0435 VDE 0110

    Abstract: No abstract text available
    Text: 1 51 Relay with 1 changeover contact 1u (gold contacts) for normal switching power Nominal input voltage VN 24 V, 115 V, 230 V AC/DC 857-364 1 <_ 81 mm/3.18 in _> 857-314 <_ 81 mm/3.18 in _> Relay with 1 changeover contact (1u) (gold contacts)


    Original
    D-32385 D-32423 relay vde 0435 VDE 0110 PDF

    MTL4526

    Abstract: MTL5526 characteristics straingauge MTLX526
    Text: MTL4526 1 2 3 2 4 5 6 All contacts shown in normal position relays de-energised 9 8 7 IS relay 13 14 2 1 Control 20 to 35V dc * this link applies only to contact/logic operation * 20 to 35V dc Vs+ Vs– MTL5526 Hazardous area SPECIFICATION 12 11 10 IS relay


    Original
    MTL4526 MTL5526 MTLX526 EPSx526 MTL4526 MTL5526 characteristics straingauge PDF

    D500-61-00

    Abstract: wiring diagram relay Circuit Diagram for 5vdc Relay Control Module SMB500 D500-61 led tv service manual IR Sensor receiver pair C0166 short circuit isolators
    Text: I56-2023-005 INSTALLATION AND MAINTENANCE INSTRUCTIONS 3825 Ohio Avenue, St. Charles, Illinois 60174 1.800.SENSOR2; Fax: 630.377.6495 www.systemsensor.com EM-1RI Relay Module SPECIFICATIONS Normal Operating Voltage: Standby Current: Alarm Current: Short Circuit Current, Dry Control Input:


    Original
    I56-2023-005 SMB500 D500-61-00 D500-61-00 wiring diagram relay Circuit Diagram for 5vdc Relay Control Module D500-61 led tv service manual IR Sensor receiver pair C0166 short circuit isolators PDF

    24DC

    Abstract: No abstract text available
    Text: Voltage Sensitive Relays WILMAR Protective Relays – WOUV DC Series, Over/Undervoltage Function: • ANSI/IEEE C37.90-1978 IPS STR WS L A E MIN SCR TER - 32 #6 The relay will energize at normal voltage conditions. The normally open contacts will close, and


    Original
    125DC 240DC 250DC 305DC 405DC 430DC 470DC 120DC 560DC 24DC PDF

    SINGLE TURN POTENTIOMETERS

    Abstract: No abstract text available
    Text: Voltage Sensitive Relays WILMAR Protective Relays – WUVT/WOVT Series Function: 27/59 • ANSI/IEEE C37.90-1978 TERMINAL STRIPS #6 - 32 SCREWS • UL file No. E58048 • CSA file No. LR61158 Undervoltage Models - The relay is energized at normal voltage, N.C. contacts will open and N.O.


    Original
    E58048 LR61158 SINGLE TURN POTENTIOMETERS PDF

    Untitled

    Abstract: No abstract text available
    Text: M0500 Tacho Voltage Detector Converter for M2100 Emergency Controller and M2000 Engine Controller More than 33% is : Crank disconnect More than 90% is : Normal R.P.M. More than 115% is : Overspeed The unit substitutes - together with the M-controller - a voltage relay and a


    Original
    M0500 M2100 M2000 2-24V M2100. DK-4000 PDF

    ptc resistor

    Abstract: 380-440VAC 230V motor control circuits PTC Resistor, IEC255-6 VDE0660 IEC68-2-30 relay spdt 230v 2a ptc thermistor level sensor IEC664-1 VDE0110
    Text: Thermistor motor protection relays Benefits and advantages Selection table Operating principle and examples of use of the thermistor motor protection relays Under normal operating conditions the resistance value is below the response value. If only one of the PTC resistors heats up excessively, the output relay


    Original
    150g/0 110g/0 EN50022) IEC255-6, VDE0660 EN60947-5-1 93/68/EWG 24VAC 24VAC/DC 110-130VAC ptc resistor 380-440VAC 230V motor control circuits PTC Resistor, IEC255-6 VDE0660 IEC68-2-30 relay spdt 230v 2a ptc thermistor level sensor IEC664-1 VDE0110 PDF

    vde 0435 0110

    Abstract: vde 0435 vde 0110
    Text: 1 JUMPFLEX Relay 52 _ <_ 94 mm/3.68 in _> _> _> <_ 96 mm/3.76 in _> With 2 relays, with 1 make contact 1 a for normal switching power Nominal input voltage VN 24 V AC/DC 6 mm/0.23 in Note: Inductive loads have to be attenuated by an


    Original
    D-32385 D-32423 vde 0435 0110 vde 0435 vde 0110 PDF

    3 phase motor auto starter circuit diagram

    Abstract: wiring diagram single phase dol starter AT66A single phase DOL starter wiring soft starter wiring integral starter is 2000 diagram dol starter 3 phase motor auto DOL starter circuit diagram wiring diagram dol starter
    Text: C€ Technical Specification PAIR Motor Protection Relay Response characteristics Overload trip characteristic PAIR is designed for use with motors which require protection against both overtoad and underload conditions. Pump motors, for example, require normal overload protection, but the pump itself can be damaged


    OCR Scan
    PDF