    C1432

    Abstract: No abstract text available
    Text: 1430 Smart indicator series Maintenance indicator • • • • • • • • • • • Monitors appliance usage Preventative maintenance reminder Direct replacement for Neon indicator Counts time that mains power is applied Remembers accumulated time even if


    Original
    UL94V2 50/60Hz C1432 PDF

    PLC tsx SCY 21601

    Abstract: CUSB485 8RPS24100 ABL8RPS24100 CANCA50 MC16ZC CANCA100 R30 1130 tsx micro ATV71
    Text: Safety automation system solutions Presentation Preventa configurable safety controllers type XPS MC Presentation 105739 Configurable safety controllers XPS MCppZp are designed to provide a solution for safety applications requiring conformity to category 4 of standard EN 954-1/EN/


    Original
    954-1/EN/ MC16ZC MC16ZP MC32Z MC32ZC CA100 CUSB485 CA400 8RPS24100 CUSB485 PLC tsx SCY 21601 8RPS24100 ABL8RPS24100 CANCA50 MC16ZC CANCA100 R30 1130 tsx micro ATV71 PDF

    MOLYNX

    Abstract: wiring diagram of cctv camera NACP20 PLW231 ptz camera pcb circuit diagram PLW233 INS00053 TRX228 ptz camera wiring diagram cctv camera circuit diagram
    Text: INSTALLATION INSTRUCTIONS INS00054 Issue 8 CONTENTS PAGE Important Notes / Preventative Maintenance . 1 General Description / Contents Of Box . 2


    Original
    INS00054 RS485 MOLYNX wiring diagram of cctv camera NACP20 PLW231 ptz camera pcb circuit diagram PLW233 INS00053 TRX228 ptz camera wiring diagram cctv camera circuit diagram PDF

    xps-ecp

    Abstract: XPS-ECP5131 XPS-ECM5131 preventa xps IEC 947-5-1 VDE 0660 preventa safety XPS-ECM3431 IEC 947-5-1 VDE 0660 LIMIT SWITCH IEC-947-5-1 AC15 B300 B300
    Text: Components for safety applications Preventa safety modules for increasing the number of safety contacts Operating principle, characteristics Operating principle 1 XPS-ECi safety modules, for increasing the number of safety contacts, are available as attachments for Preventa XPS


    Original
    U1-13 U1-23. xps-ecp XPS-ECP5131 XPS-ECM5131 preventa xps IEC 947-5-1 VDE 0660 preventa safety XPS-ECM3431 IEC 947-5-1 VDE 0660 LIMIT SWITCH IEC-947-5-1 AC15 B300 B300 PDF

    Untitled

    Abstract: No abstract text available
    Text: Product data sheet Characteristics XPSMC32Z safety controller XPS-MC - 24 V DC - 32 input 46 LEDs signalling Commercial Status Commercialised Range of product Preventa Safety automation Product or component type Configurable safety controller Safety module name


    Original
    XPSMC32Z 954-1/EN/ 1760-1/ISO 574/ISO 954-1/EN/ISO PDF

    Untitled

    Abstract: No abstract text available
    Text: Product data sheet Characteristics XPSAXE5120P module XPSAXE - stop and switch monitoring 24 V DC Commercial Status Commercialised Range of product Preventa Safety automation Product or component type Preventa safety module Safety module name XPSAXE Safety module


    Original
    XPSAXE5120P 1088/ISO PDF

    Untitled

    Abstract: No abstract text available
    Text: Product data sheet Characteristics XPSATR3953P module XPSATR - Emergency stop and protective guard - 115-230V AC, time delay 3s Commercial Status Commercialised Range of product Preventa Safety automation Product or component type Preventa safety module Safety module name


    Original
    XPSATR3953P 15-230V PDF

    Untitled

    Abstract: No abstract text available
    Text: Product data sheet Characteristics XPSATR3953C module XPSATR - Emergency stop and protective guard - 115-230V AC, time delay 3s Commercial Status Commercialised Range of product Preventa Safety automation Product or component type Preventa safety module Safety module name


    Original
    XPSATR3953C 15-230V PDF

    XPSABV1133C

    Abstract: No abstract text available
    Text: Product data sheet Characteristics XPSABV1133C module XPSABV - stop and switch monitoring 24 V AC/DC Jun 18, 2014 Commercial Status Commercialised Range of product Preventa Safety automation Product or component type Preventa safety module Safety module name


    Original
    XPSABV1133C 1088/ISO XPSABV1133C PDF

    XPSAX

    Abstract: No abstract text available
    Text: Product data sheet Characteristics XPSAXE5120C module XPSAXE - stop and switch monitoring 24 V DC Commercial Status Commercialised Range of product Preventa Safety automation Product or component type Preventa safety module Safety module name XPSAXE Safety module


    Original
    XPSAXE5120C 1088/ISO XPSAX PDF

    C300

    Abstract: DC-13 R300 XCSLE3535342
    Text: Product data sheet Characteristics XCSLE3535342 plastic key operated soleonid switch XCSLE 2NC+4NO - slow BBM - M20 - 230V Range of product Preventa Safety detection Product or component type Safety switch Component name XCSLE Design Slim Material Plastic


    Original
    XCSLE3535342 C22-2 1088/ISO C300 DC-13 R300 XCSLE3535342 PDF

    IEC 60947-5-1

    Abstract: XCSC511 60947-5-1 A300 DC-13 Q300 XCS-C511
    Text: Product data sheet Characteristics XCSC511 metal guard switch XCSC - 1 NC+2 NO - slow break - 1 entry tapped Pg 13.5 Range of product Preventa Safety detection Product or component type Guard switch Component name XCSC Material Metal Head type Key operated turret head


    Original
    XCSC511 C22-2 1088/ISO 4Q2009 IEC 60947-5-1 XCSC511 60947-5-1 A300 DC-13 Q300 XCS-C511 PDF

    telemecanique XCS-E

    Abstract: Telemecanique XPS Preventa xps-ac XPSAT5110 XPSAF5130 xpsav11113 XPS-AT3410 telemecanique xps-ak XPS-AC XPSAC5121P
    Text: Machine Safeguarding Products PREVENTA XPS Safety Relays Supplement Catalog 03 File 9007 CONTENTS Description Page Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10 General Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12


    Original
    1-888-SquareD 9007CT0203 telemecanique XCS-E Telemecanique XPS Preventa xps-ac XPSAT5110 XPSAF5130 xpsav11113 XPS-AT3410 telemecanique xps-ak XPS-AC XPSAC5121P PDF

    XCSC501

    Abstract: XCS-C501 60947-5-1 IEC 60947-5-1 IEC 60947-5-1 switch ISO STANDARDS SHEET METAL A300 DC-13 Q300
    Text: Product data sheet Characteristics XCSC501 metal guard switch XCSC - 1 NC+2 NO - slow break - 1 entry tapped Pg 13.5 Range of product Preventa Safety detection Product or component type Guard switch Component name XCSC Material Metal Head type Key operated turret head


    Original
    XCSC501 C22-2 1088/ISO 4Q2009 XCSC501 XCS-C501 60947-5-1 IEC 60947-5-1 IEC 60947-5-1 switch ISO STANDARDS SHEET METAL A300 DC-13 Q300 PDF

    XCSLF3737313

    Abstract: C300 DC-13 R300
    Text: Product data sheet Characteristics XCSLF3737313 metal key operated solenoid switch XCSLF 4NC+2NO - slow BBM - 1/2"NPT- 24 V Range of product Preventa Safety detection Product or component type Safety switch Component name XCSLF Design Slim Material Metal Head type


    Original
    XCSLF3737313 Voltage15. C22-2 1088/ISO XCSLF3737313 C300 DC-13 R300 PDF

    XCSLE2727312

    Abstract: C300 DC-13 R300 schneider cat 6 cable
    Text: Product data sheet Characteristics XCSLE2727312 plastic key operated soleonid switch XCSLE 4NC - slow BBM - M20 - 24 V Range of product Preventa Safety detection Product or component type Safety switch Component name XCSLE Design Slim Material Plastic Head type


    Original
    XCSLE2727312 Voltage15. C22-2 1088/ISO XCSLE2727312 C300 DC-13 R300 schneider cat 6 cable PDF

    XPSAF5130

    Abstract: XPS-AF5130 XPSAF5130P XPS AF xps-af XPS-Af5130p IEC 60947-5-1 limit switch XPSAF5130 module XPSAF - Emergency stop - 24 V AC DC DF565752 emergency stop relay
    Text: Safety automation system solutions Operating principle, characteristics Preventa safety relay modules type XPSAF For Emergency stop and switch monitoring Operating principle Safety modules XPSAF are designed to conform with category 4 of the standard EN 954-1/ISO 13849-1.


    Original
    EN954-1/ISO EN/ISO13850 EN/IEC60204-1. EN1088/ISO14119. XPSAF5130 XPSAF5130P DF565752 XPSAF5130 XPS-AF5130 XPSAF5130P XPS AF xps-af XPS-Af5130p IEC 60947-5-1 limit switch XPSAF5130 module XPSAF - Emergency stop - 24 V AC DC DF565752 emergency stop relay PDF

    XCS-E7313

    Abstract: ISO STANDARDS SHEET METAL XCSE7313 B300 DC-13 Q300 IEC 60947-5-1 2052V
    Text: Product data sheet Characteristics XCSE7313 metal guard switch XCSE - 2NC+1NO - slow break- 2 entries tapped 1/2" NPT Range of product Preventa Safety detection Product or component type Guard switch Component name XCSE Material Metal Head type Key operated turret head


    Original
    XCSE7313 C22-2 1088/ISO XCS-E7313 ISO STANDARDS SHEET METAL XCSE7313 B300 DC-13 Q300 IEC 60947-5-1 2052V PDF

    XPS-AK371144

    Abstract: xps-ak xpsak311144p XPSAK361144P XPSAK361144 XPS-AK311144 xpsak311144 XPSAK331144P XPSAK371144 XPS-AK361144
    Text: Operating principle, characteristics Safety automation system solutions Preventa safety relay modules type XPSAK For Emergency stop, switch, sensing mat/edges or light curtain monitoring Operating principle Safety modules XPSAK are designed to conform with category 4 of the standard


    Original
    EN954-1/ISO EN/ISO13850 EN/IEC60204-1. exaAK361144P DF565754 XPSAK351144P XPSAK3p1144 DF565755 XPSAK3p1144P XPSAK371144P XPS-AK371144 xps-ak xpsak311144p XPSAK361144P XPSAK361144 XPS-AK311144 xpsak311144 XPSAK331144P XPSAK371144 XPS-AK361144 PDF

    XPSVNE1142P

    Abstract: tsxpcx1031 XPSAF5130 XPS-AC5121 XPSAV11113P XPSAC5121P XPSAFL5130 XPSDMB1132P XPS-AC XPSAF5130P
    Text: 1467-2012.qxp:QuarkCatalogTempNew 9/7/12 3:41 PM Page 1467 15 Safety Equipment TEST & MEASUREMENT Safety Limit Switches — XCS Series Preventa XCS safety limit switches are designed to protect personnel in machine guarding applications where physical contact with the guard is required. Featuring


    Original
    70008No. XPSMC16Z XPSMC16ZC XPSMC16ZP XPSMC32Z XPSMC32ZC XPSMC32ZP XPSMCTS16 XPSMCTS32 TSXCUSB485 XPSVNE1142P tsxpcx1031 XPSAF5130 XPS-AC5121 XPSAV11113P XPSAC5121P XPSAFL5130 XPSDMB1132P XPS-AC XPSAF5130P PDF

    XPS-ASf

    Abstract: XPS-ASF5142 XPS-AS XPS-ASF3442 XPS-Apf xpsasf5142 XPS-ASF3742 Y33-Y34 xps-bc S41-S42
    Text: Components for safety applications Preventa safety modules for emergency stop, limit switch, two-hand control, safety mat and edge monitoring Operating principle, characteristics Operating principle see page 1/12 1 Characteristics Type XPS-ASF Product designed for use in safety


    Original
    S11-S12, S21-S22 S11-B1 S21-S22 S11-S12) S33-S34 S21-S22) Y33/43 XPS-ASf XPS-ASF5142 XPS-AS XPS-ASF3442 XPS-Apf xpsasf5142 XPS-ASF3742 Y33-Y34 xps-bc S41-S42 PDF

    AM1-DP200

    Abstract: XPS-ot XPS-AS preventa safety GNKL AM1DP200 XPS-AT XPS-ASf xps-ecp Preventa xps-al
    Text: Components for safety applications Preventa safety modules Dimensions, mounting XPS-AL, XPS-AX AM1-DP200 rail mounting 78 78 1 120 22,5 78 78 XPS-AT, XPS-FB, XPS-AM, XPS-AMF, XPS-AP, XPS-APF, XPS-ECM, XPS-ECP, XPS-NS, XPS-VN AM1-DP200 rail mounting 120 90


    Original
    AM1-DP200 M1-DP200 XPS-ot XPS-AS preventa safety GNKL AM1DP200 XPS-AT XPS-ASf xps-ecp Preventa xps-al PDF

    EN1050

    Abstract: IEC 947-5-1 VDE 0660 LIMIT SWITCH XPS-FB5111 xps* preventa xps-fb XPSFB3711 Electronic fuse linked state machines electromagnetic lock Y4 S4
    Text: Components for safety applications Preventa safety modules for electrical monitoring of limit switches combined in pairs Operating principle Operating principle 1 Preventa safety module XPS-FB meets the safety requirements for monitoring the operation of 2 limit switches used on


    Original
    PDF

    EN 60947-5-1 relay

    Abstract: Preventa xps-at
    Text: Product data sheet Characteristics XPSATE5110 module XPSAT - Emergency stop - 24 V DC Product availability: Stock - Normally stocked in distribution facility Price*: 668.00 USD Dec 15, 2014 Commercial Status Commercialised Range of product Preventa Safety automation


    Original