Bimetallic strip as fuse
Abstract: VDE 0660 - fuse breaker 91H22 DIN 40050 Part 9 IEC 529 91h1 91H-2 91-H-1-40 41a 934
Text: CIRCUIT BREAKERS DIN-rail Mounted Equipment Protection USA Phoenix Contact Inc. P.O. Box 4100 Harrisburg, PA 17111-0100 Phone: 800-888-7388 717-944-1300 Technical Service: 800-322-3225 Fax: 717-944-1625 E-mail: info@phoenixcon.com Website: www.phoenixcon.com
|
Original
|
L002030
Bimetallic strip as fuse
VDE 0660 - fuse breaker
91H22
DIN 40050 Part 9 IEC 529
91h1
91H-2
91-H-1-40
41a 934
|
PDF
|
Untitled
Abstract: No abstract text available
Text: TMCP SOCKET M Modular base, 2-position, for holding two circuit breakers, each with single positions CLIPLINE Data Sheet 104391_en_00 1 PHOENIX CONTACT 2010-05-26 Description The TMCP SOCKET M base is snapped onto a DIN rail and can accommodate two single-position circuit breakers of
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: QUINT-PS/24DC/48DC/ 5 DC/DC converter with SFB technology, primaryswitched, input: 24 V DC, output: 48 V DC, output current: 5 A Data sheet 104793_en_01 1 PHOENIX CONTACT 2013-05-03 Description QUINT DC/DC converter – maximum system availability from SFB technology
|
Original
|
QUINT-PS/24DC/48DC/
|
PDF
|
2A Fuse Breaker
Abstract: gG fuse type TO IEC 269 6tmc
Text: UT 6-TMC M. Thermomagnetic circuit breakers CLIPLINE Data sheet 103943_en_01 1 PHOENIX CONTACT - 08/2009 Description The UT 6-TMC M circuit breaker is a single-position overload circuit breaker with thermomagnetic tripping. It is a space-saving circuit breaker with trip-free mechanism in the
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: UT 6-TMC M. Thermomagnetic circuit breakers CLIPLINE Data sheet 103943_en_04 1 PHOENIX CONTACT 2010-08-18 Description The UT 6-TMC M circuit breaker is a single-position overload circuit breaker with thermomagnetic tripping. It is a space-saving circuit breaker with trip-free mechanism in the
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: TMCP Thermomagnetic circuit breaker for mounting in a base CLIPLINE Data sheet 100211_en_02 1 PHOENIX CONTACT 2010-02-17 Description Single or multi-position thermomagnetic circuit breaker with lever actuation, base or front mounting, trip-free mechanism
|
Original
|
|
PDF
|
43 e-t-a
Abstract: No abstract text available
Text: Thermal-Magnetic Circuit Breakers 3600/3900 Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation M-type TM CBE to EN 60934 . Designed for plug-in mounting with E-T-A sockets 17-P10-Si,
|
Original
|
17-P10-Si,
23-P10-Si,
63-P10-Si;
ISO1207
10-way)
43 e-t-a
|
PDF
|
connectwell
Abstract: Allen Bradley ferrules Entrelec TAG ABB EK 210 WAGO DIN 50022 - SS ca749 Entrelec M 702 allen bradley W4 BUS gmh7
Text: To put the finishing touch on your application, we offer an extensive selection of useful accessories to build and install DIN Rail terminal block assemblies and to facilitate factory and field wiring. Accessories include end stops, end plates and partitions. Also offered
|
Original
|
|
PDF
|
connectwell
Abstract: abb entrelec relays B4U marking CTS10U 3 pole circuit breaker ABB Allen Bradley ferrules Entrelec TAG DIN 50045 4x4 keyboard abb dc motor
Text: To put the finishing touch on your application, we offer an extensive selection of useful accessories to build and install DIN Rail terminal block assemblies and to facilitate factory and field wiring. Accessories include end stops, end plates and partitions. Also offered
|
Original
|
|
PDF
|
17-P10-Si
Abstract: X20040901 din 46247 63-P10-Si 46247 50035-G32 2x110 50022-35x7 23-P10-Si din 46244-A6.3-0.8
Text: Thermal-Magnetic Circuit Breakers 3600/3900 Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation M-type TM CBE to EN 60934 . Designed for plug-in mounting with E-T-A sockets 17-P10-Si, 23-P10-Si, 63-P10-Si; or panel mounting using E-T-A clips.
|
Original
|
17-P10-Si,
23-P10-Si,
63-P10-Si;
50035-G32
ISO1207
17-P10-Si
X20040901
din 46247
63-P10-Si
46247
50035-G32
2x110
50022-35x7
23-P10-Si
din 46244-A6.3-0.8
|
PDF
|
3600-P10-Si
Abstract: 17-P10-Si 50035-G32 din 46247 17-P70-Si 4.8 din 46247 X20040901 50-035-G32 23-P10-Si
Text: Thermal-Magnetic Circuit Breakers 3600/3900 Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation M-type TM CBE to EN 60934 . Designed for plug-in mounting with E-T-A sockets 17-P10Si, 23-P10-Si, 63-P10-Si; or panel mounting using E-T-A clips. Featuring
|
Original
|
17-P10Si,
23-P10-Si,
63-P10-Si;
46244-A6
3600-P10-Si
17-P10-Si
50035-G32
din 46247
17-P70-Si
4.8 din 46247
X20040901
50-035-G32
23-P10-Si
|
PDF
|
5sy61
Abstract: SIEMENS circuit breakers b16 5SY6 5SY6106-6 61558-2-17 siemens SIEMENS circuit breakers PLC siemens S7-300 rail MTBF SIEMENS MTBF SIEMENS s7-300 PLC S7-300 redundant
Text: QUINT-PS/24DC/24DC/ 5 DC/DC converter with SFB technology, primaryswitched, 5 A output current INTERFACE Data sheet 104504_en_00 1 PHOENIX CONTACT 2011-09-19 Description QUINT DC/DC converter – maximum system availability from Features SFB technology
|
Original
|
QUINT-PS/24DC/24DC/
5sy61
SIEMENS circuit breakers b16
5SY6
5SY6106-6
61558-2-17 siemens
SIEMENS circuit breakers
PLC siemens S7-300 rail
MTBF SIEMENS
MTBF SIEMENS s7-300
PLC S7-300 redundant
|
PDF
|
Untitled
Abstract: No abstract text available
Text: QUINT-PS/ 3AC/24DC/20 Primary-switched power supply with SFB technology, 3 AC, output current 20 A INTERFACE Data sheet 303132_en_01 1 PHOENIX CONTACT - 09/2009 Description QUINT POWER power supply units – Maximum system availability with SFB technology
|
Original
|
3AC/24DC/20
coIODE/40,
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Power Supply Unit, Primary Switched, Narrow Design MINI-SYS-PS-100-240AC/24DC/1.5 MINI POWER provides: • Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm 0.886, 1.772, and 2.657 in. • Global use due to a wide-range voltage input • A high level of operational safety in complex
|
Original
|
MINI-SYS-PS-100-240AC/24DC/1
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: QUINT-PS/ 3AC/24DC/10 Primary-switched power supply with SFB technology, 3 AC, output current 10 A INTERFACE Data sheet 103131_en_01 1 PHOENIX CONTACT - 09/2009 Description QUINT POWER power supply units – Maximum system availability with SFB technology
|
Original
|
3AC/24DC/10
coIODE/40,
|
PDF
|
Untitled
Abstract: No abstract text available
Text: ECP-E2. Electronic circuit breaker CLIPLINE Data sheet 102899_en_03 1 PHOENIX CONTACT 2010-12-17 Description The ECP-E2… electronic circuit breaker can be used in applications that cover all aspects of the switched-mode power supply unit. In the event of an overload, switched-mode power supply
|
Original
|
|
PDF
|
F47-200
Abstract: S7-300 103-131
Text: QUINT-PS/3AC/24DC/10 Primary-switched power supply with SFB technology, 3 AC, output current 10 A INTERFACE Data Sheet 103131_en_00 PHOENIX CONTACT - 11/2007 Description Features QUINT POWER power supply units – highest system availability due to SFB technology
|
Original
|
QUINT-PS/3AC/24DC/10
bUINT-DIODE/40,
F47-200
S7-300
103-131
|
PDF
|
Untitled
Abstract: No abstract text available
Text: ECP-E… Electronic circuit breaker CLIPLINE Data sheet 102898_en_03 1 PHOENIX CONTACT 2010-12-17 Description The ECP-E… electronic circuit breaker can be used in applications that cover all aspects of the switched-mode power supply unit. In the event of an overload, switched-mode power supply
|
Original
|
|
PDF
|
S7-300
Abstract: DIODE i2t
Text: QUINT-PS/3AC/24DC/ 5 Primary-switched power supply with SFB technology, 3 AC, output current 5 A INTERFACE Data Sheet 103130_en_00 PHOENIX CONTACT - 11/2007 Description Features QUINT POWER power supply units – highest system availability due to SFB technology
|
Original
|
QUINT-PS/3AC/24DC/
byUINT-DIODE/40,
S7-300
DIODE i2t
|
PDF
|
Untitled
Abstract: No abstract text available
Text: ECP-E3. Electronic circuit breaker CLIPLINE Data sheet 103057_en_03 1 PHOENIX CONTACT 2010-12-17 Description The ECP-E3… electronic circuit breaker can be used in applications that cover all aspects of the switched-mode power supply unit. In the event of an overload, switched-mode power supply
|
Original
|
|
PDF
|
dnv certificate
Abstract: S7-300 MTBF F47-0706 S7-300 relay ul 1604
Text: Extract from the online catalog QUINT-PS/ 3AC/24DC/10 Order No.: 2866705 DIN rail power supply unit 24 V DC/10 A, primary switched-mode, 3phase. The SFB technology Selective Fuse Breaking Technology
|
Original
|
3AC/24DC/10
DC/10
IF-2009)
3AC/24DC/10
dnv certificate
S7-300 MTBF
F47-0706
S7-300
relay ul 1604
|
PDF
|
S7-300
Abstract: No abstract text available
Text: QUINT-PS/3AC/24DC/20 Primary-switched power supply with SFB technology, 3 AC, output current 20 A INTERFACE Data Sheet 103132_en_00 PHOENIX CONTACT - 11/2007 Description Features QUINT POWER power supply units – highest system availability due to SFB technology
|
Original
|
QUINT-PS/3AC/24DC/20
bUINT-DIODE/40,
S7-300
|
PDF
|
F47-0706
Abstract: No abstract text available
Text: Extract from the online catalog QUINT-PS/ 1AC/24DC/ 3.5 Order No.: 2866747 DIN rail power supply unit 24 V DC/3.5 A, primary switched-mode, 1phase. The SFB technology Selective Fuse Breaking Technology
|
Original
|
1AC/24DC/
IF-2009)
F47-0706
|
PDF
|
phoenix contact DIN rail mounted circuit breakers
Abstract: DIN RAIL S7-300 F47-0706 S7-300 UL Listed certification
Text: Extract from the online catalog QUINT-PS/ 1AC/24DC/ 3.5 Order No.: 2866747 DIN rail power supply unit 24 V DC/3.5 A, primary switched-mode, 1phase. The SFB technology Selective Fuse Breaking Technology
|
Original
|
1AC/24DC/
IF-2009)
phoenix contact DIN rail mounted circuit breakers
DIN RAIL S7-300
F47-0706
S7-300
UL Listed certification
|
PDF
|