    PEPPERL FUCHS KFD2 Search Results

    PEPPERL FUCHS KFD2 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    IEC 60947-5-6

    Abstract: namur standard LFL-Z231 60947-5-6 LFL-Z131 float switch LIMIT SWITCH namur application 68307 Pepperl Fuchs kfd2 LFL-Z32
    Text: Pepperl+Fuchs offers a wide range of float switches: Application - suitable for use up to Ex-area zone 1 - mercury-free switching element - nominal voltage, 8 V per EN 60947-5-6 NAMUR - connected through a transformer isolated barrier (i.e. KFD2-SR.) - mercury-free switching element


    Original
    PDF

    kfd2-eb2

    Abstract: NE44 atex 2035 kfd2 kfd2-sot2-ex2 IEC 60947-5-6 pepperl
    Text: Switch Amplifier KFD2-SOT2-Ex2.IO Assembly Features • • • • • • • 2-channel isolated barrier 24 V DC supply Power Rail Dry contact or NAMUR inputs Isolated passive transistor output, non-polarized Line fault detection (LFD) Reversible mode of operation


    Original
    PDF UPR-03 UPR-03 kfd2-eb2 NE44 atex 2035 kfd2 kfd2-sot2-ex2 IEC 60947-5-6 pepperl

    KFD2-SR2-Ex2.W

    Abstract: IEC 60947-5-6 NE44 kfd2-eb2 60947-5-6 kfd2 atex transformer Pepperl Fuchs kfd2 Ignition Transformer namur standard
    Text: Transformer Isolated Barriers KFD2-SR2-Ex2.W Output: Relay Input I EEx ia IIC Input II EEx ia IIC 1+ 4+ 6- 400 Ω ≤ R ≤ 2 kΩ 10 kΩ 3- Switch S3 in position I 10 kΩ 4+ 6- Switch S3 in position I 24 V DC: without SC • • • • 2-channel Control circuit EEx ia IIC


    Original
    PDF

    KFD2-SR2-Ex1.W

    Abstract: IEC 60947-5-6 kfd2-eb2 NE44 IEC 60947-5-6 NAMUR 60947-5-6 kfd2 Pepperl Fuchs kfd2 EN50-020 Ignition Transformer
    Text: Transformer Isolated Barriers KFD2-SR2-Ex1.W Output: Relay Input I EEx ia IIC 3400 Ω ≤ R ≤ 2 kΩ 1+ Switch S3 in position I without SC • • • • 1-channel Control circuit EEx ia IIC Reversible mode of operation 1 relay output with 1 changeover


    Original
    PDF

    IEC 60947-5-6

    Abstract: 60947-5-6 KFD2-SRA-Ex4 NCN3-F24R-N4 NCB2-12GM35-N0 NCB15 U1 NO NCB15 NCN3-F36-N4 namur standard positioner valve positioners
    Text: Transformer Isolated Barriers KFD2-SRA-Ex* Output: Relay Input EEx ia IIC Input II + - Control circuit EEx ia IIC 24 V DC nominal supply voltage Reversible mode of operation Lead monitoring short circuit LK and interruption LB with LED indicator (red flashing), switching output and


    Original
    PDF 15-30GKK-N 15-30GM-N 20-40-N 25-50-N NCN15-M1K-N0 NCB15 NCN20 NCN30 NCN40 NCN3-F24L-N4 IEC 60947-5-6 60947-5-6 KFD2-SRA-Ex4 NCN3-F24R-N4 NCB2-12GM35-N0 NCB15 U1 NO NCN3-F36-N4 namur standard positioner valve positioners

    kfd2

    Abstract: Pepperl Fuchs kfd2 terminal EEx e II T6 SD 621 transistor DIN EN 50014 STANDARD mh 776 Pepperl Fuchs kfd2 sl2 T4 621 99-ATEX 00ATEX
    Text: Current limit 35 mA • 1-channel • Output EEx ia IIC • Device installation permissible in zone 2 • 24 V DC nominal supply voltage • Usable up to SIL 3 acc. to IEC 61508 2- 1+ 2- 1+ Standard type KFD2-SL2-Ex1.B Function The KFD2-SD-Ex1.48 and the KFD2-SD-Ex1.48.90A receives its


    Original
    PDF

    H05VVF2X1

    Abstract: H05VV-F2 sensors connected to plc kfd2-eb2 UC500 UC4000 PR05 kfd2
    Text: The AS-interface AS-interface replaces the cable tree PLC / PC PLC / PC 2 wires each for data and power supply AS-i Power supply Only 2 wires total for data and power supply Actuators with integrated AS-i chip Multiple sensor connection Actuators with integrated


    Original
    PDF

    kfd2-stc4

    Abstract: BAS 99 ATEX 7060 kfd2-stc4-ex1 bas99 EN50-020 atex 7060 kfd2-eb2 61508 UPR-03 EN 50014 to 50020
    Text: KFD2-STC4-Ex1 SMART transmitter power supply Connection • 1-channel • Device installation permissible in zone 2 • Input EEx ia IIC; Uo = 25.4 V • Galvanically isolated output • 24 V DC supply voltage • SMART capable up to 7.5 kHz -3 dB • EMC acc. to NAMUR NE 21


    Original
    PDF PR-03 UPR-03 kfd2-stc4 BAS 99 ATEX 7060 kfd2-stc4-ex1 bas99 EN50-020 atex 7060 kfd2-eb2 61508 EN 50014 to 50020

    kfd2-eb2

    Abstract: kfd2-cd-ex1.32 namur NE 93 kfd2 DIN 50014 ATEX 014 KFD2-CD valve positioners 0/kfd2-cd-ex1.32
    Text: KFD2-CD-Ex1.32 Current/voltage repeater Connection • • • • • • • • • 1-channel Output EEx ia IIC 24 V DC supply voltage Device installation permissible in zone 2 Conversion of current/voltage or voltage/current Elevation/Suppression of the "life


    Original
    PDF PR-03 UPR-03 kfd2-eb2 kfd2-cd-ex1.32 namur NE 93 kfd2 DIN 50014 ATEX 014 KFD2-CD valve positioners 0/kfd2-cd-ex1.32

    KFD2-STC4-EX2

    Abstract: kfd2-stc4 abb SMART temperature Transmitter transmitter calibration certificate foxboro fisher-rosemount hazardous area Endress namur NE 21 BY260V
    Text: SMART Transmitter Power Supply KFD2-STC4-Ex2 - Input EEx ia IIC ? - DC 24 V power supply Input ΙΙ EEx ia IIC ? J J 2-wire transmitters - EMC per NAMUR NE 21 - LED per NAMUR NE 44 The SMART transmitter power supplies supply a 2-wire SMART transmitter within a


    Original
    PDF

    Catalog Sensors for Process Applications

    Abstract: NCB1.5-8GM25-N0 5M
    Text: FACTORY AUTOMATION CATALOG SENSORS FOR PROCESS APPLICATIONS 1FQQFSM 'VDIT°6OCFBUBCMFGPSRVBMJUZBOEDIPJDF 8F BSF B MFBEJOH NBOVGBDUVSFS PG JOEVTUSJBM TFOTPST BOE TFOTPS TZTUFNT 


    Original
    PDF 199003130E Catalog Sensors for Process Applications NCB1.5-8GM25-N0 5M

    EX-94

    Abstract: kha6-sr2-ex KHA6 namur NE 21 KHA6-SR2-Ex1.W KHA5-S kfd2-sr-ex1 KFD2-SR2-EX1.W DIN19234 KFA5
    Text: P R O Z E S S A U T O M A T I O N Trennschaltverstärker K -SR2-Ex1.W Ausgang: Relais Eingang EEx ia IIC - 1-kanalig - Steuerstromkreis EEx ia IIC 1+ 3- - 1 Signalausgang mit 1 Wechsler - EMV gemäß NAMUR NE 21 Schalter S3 in Pos. I 10 kΩ 1+ 3- KFD2-SR2-Ex1.W


    Original
    PDF Signalgebe50 EX-94 kha6-sr2-ex KHA6 namur NE 21 KHA6-SR2-Ex1.W KHA5-S kfd2-sr-ex1 KFD2-SR2-EX1.W DIN19234 KFA5

    kfd2-stc1-ex1

    Abstract: kfd2 fisher-rosemount Ex-94 namur NE 93 namur NE 21 STT01 ST-T01 bailey transmitter abb SMART temperature Transmitter
    Text: SMART Transmitter Power Supplies Hazardous area KFD2-ST*1-Ex1* Input EEx ia IIC SMART transmitter SMART communicator 1-channel Input EEx ia IIC; U0 = 28V 24 V DC nominal supply voltage SMART capable up to 12 kHz -1 dB EMC acc. to NAMUR NE 21 1+ 3- 1+ + -


    Original
    PDF

    KFD2-EB-D2A.B

    Abstract: kfd2 ji-30 via 1618 T4 621
    Text: KFD2-EB.D2A.B Power Rail power feed module for redundant supply, with bus terminals Connection Supply 8+ • 24 V DC supply voltage • Device installation permissible in zone 2 • Supply current ≤ 2 A • Bus access via terminals • Redundant supply • Fault signal output with adjustable


    Original
    PDF

    IEC 60947-5-6

    Abstract: LIMIT SWITCH namur application DN100 PN16 KEMA Flow switch CA3 DN40 EN 10204 3.1 DN100-PN40 DN80-PN40 10204 3.1b material certificate namur float
    Text: Vibration limit switch Dimensions Ø85 max. 76 L ~25 max. 140 Vibracon LVL-M with plastic housing and process connection Goo 17.5 max. 65 Ø80 max. 60 Vibracon LVL-M NAMUR max. 40.7 max. 173 Vibracon LVL-M with aluminium housing and process connection with flange


    Original
    PDF 4435/316L 4435/316L, mm/115 IEC 60947-5-6 LIMIT SWITCH namur application DN100 PN16 KEMA Flow switch CA3 DN40 EN 10204 3.1 DN100-PN40 DN80-PN40 10204 3.1b material certificate namur float

    KFD2-SR2-EX1.W

    Abstract: DMT 98 IEC 60947-5-6 VIBRATION LIMIT SWITCH EXZONE "Isolation Amplifier" atex transformer BARRIER E ectfe Ignition Transformer
    Text: Dimensions V1 connector PG9 110 Testing magnet LED Housing Housing 41 120 Vibrating Limit Switch LVL 5.5 19 Testing magnet 127 G1A Switching point G1A 25 ø29 L 10 22 LED Switching state yellow LVL-N Compact version LVL1 -V1 ooo 10 22 Extended version LVL2


    Original
    PDF

    kfd2-sr-ex1

    Abstract: KFD2-SR2-EX1.W k-system namur NE 21 VDE 0812 PTB Switch Mode dc to ac Supply circuit DIN19234 EX-94
    Text: Transformer Isolated Barrier KF -SR2-Ex1.W Output: Relay - Control circuit EEx ia IIC Class I, Div 1, Groups A-G Switch S3 in position I 1+ - Reversible mode of operation 3- - 1 Signal output with 1 alternator - EMC per NAMUR NE 21 1+ Switch S3 in position I


    Original
    PDF

    KFU8-UFC-1.D

    Abstract: k-adp1 namur NE 43 VDE 0106 VDE 0106 Part 1 KFD2-UFC KFU8-UFC-1 namur standard ufc 101 kfd2
    Text: Logic Control Units, Universal Frequency Converters KFU8-UFC-1* 1+ 10 k 3- 1+ 3400 Ω ≤ R ≤ 2 kΩ 1 K-ADP1 RS 232 3- 2 1+ 10 k 3- 1+ 3 + 2- 3 PC Signal processor TTL yellow/ red green U yellow TXD • • 1+ yellow yellow GND • • • 1-channel


    Original
    PDF

    4890A

    Abstract: kfd2
    Text: P R O C E S S A U T O M A T I O N KFD2-SD-Ex1.48 KFD2-SD-Ex1.48.90A Output EEx ia IIC - Single Channel - Output EEx ia IIC Class I, Div 1, Groups A-G - DC 24 V Loop Powered 2- 1+ 2- 1+ Hazardous area Solenoid Drivers KFD2-SD-Ex1.48 - Output Current KFD2-SD-Ex1.48:


    Original
    PDF

    k-adp1

    Abstract: Thermocouple Type B kfd2-ut transformer pt-100 kfd2 signal converter pt100 RS-232PC
    Text: P R O C E S S A U T O M A T I O N Converter KFD2-UT-Ex1 Input EEx ia IIC - Single Channel - Input EEx ia IIC Class I, Div 1, Groups A-G cold junction compensation Typ K-CJC Thermocouple - Output: 4 . 20mA 2- - Optional 1 . 5V Output - Setting options through Serial Interface:


    Original
    PDF Pt100 24VDC 4-20mA k-adp1 Thermocouple Type B kfd2-ut transformer pt-100 kfd2 signal converter pt100 RS-232PC

    VIBRATION LIMIT SWITCH

    Abstract: LVL1S-G3S-N-V1 LVL -S NAMUR LVL NAMUR Limit Switch Testing KFD2-SR2-EX1.W LVL2O-G3OS-N-V1
    Text: P R O C E S S A U T O M A T I O N Vibrating Limit Switch testing magnet 110 - stainless steel housing for rough environmental conditions housing - function test with testing magnet in mounted position housing 41 41 19 G1A G1A 127 Compact version LVL1 LVL1S-G3S-N-V1


    Original
    PDF LVL-Z61 LVL-Z62 VIBRATION LIMIT SWITCH LVL1S-G3S-N-V1 LVL -S NAMUR LVL NAMUR Limit Switch Testing KFD2-SR2-EX1.W LVL2O-G3OS-N-V1

    kha6-sr2-ex

    Abstract: namur NE 21 KFD2-SR2-Ex2.W KFA6-SR2-EX2.W kfd2-sr-ex2 Ex-94 VDE 0812 PTB VDE 0812 S KHA5-S lb 7610
    Text: P R O Z E S S A U T O M A T I O N Trennschaltverstärker K - 2-kanalig Eingang Ι EEx ia IIC -SR2-Ex2.W Ausgang: Relais Eingang ΙΙ EEx ia IIC - Steuerstromkreis EEx ia IIC - 1 Signalausgang mit 1 Wechsler je Kanal 1+ 3- 4+ 6Schalter S3 in Pos. Ι - EMV gemäß NAMUR NE 21


    Original
    PDF

    50mA fuse

    Abstract: 4-20ma to 2-10v converter Voltage to Current Converter circuit 4-20mA kfd2-cd-ex1.32 kfd2
    Text: P R O C E S S A U T O M A T I O N - Single Channel Hazardous area TIBs for Current / Voltage KFD2-CD-Ex1.32 Output EEx ia IIC - Output EEx ia IIC Class I, Div 1, Groups A-G ? J - DC 24 V Nominal Power Supply - Voltage / Current or Current / Voltage Conversion


    Original
    PDF 0/4-20mA 0/2-10V 50mA fuse 4-20ma to 2-10v converter Voltage to Current Converter circuit 4-20mA kfd2-cd-ex1.32 kfd2

    kfd2-sr-ex2

    Abstract: KFA6-SR2-EX2.W kfd2 EX-94 KFD2-SR2-Ex2.W
    Text: Transformer Isolated Barrier KF Input ΙΙ - Control circuit EEx ia IIC Class I, Div 1, Groups A-G Switch S3 in position Ι - Reversible mode of operation 1+ 3- 4+ 6- - 1 Signal output with 1 alternator Switch S3 in position Ι - EMC per NAMUR NE 21 10 kΩ


    Original