Untitled
Abstract: No abstract text available
Text: Figure 12: Typical Spectral Response of PbS Cells PbS and PbSe Cells PbS and PbSe cells are photoconductive sem iconductors which de tect infrared radiation utilizing the fact that their resistance drops upon application o f incident infrared radiation. C om pared to other
|
OCR Scan
|
KIRDC0012EA
|
PDF
|
Hamamatsu PbS
Abstract: No abstract text available
Text: INFRARED DETECTOR PbS photoconductive detector P9217 Infrared detectors utilizing photoconductive effects P9217 is a PbS photoconductive detector with greatly improved stability and resistance to high temperatures when compared to conventional types. Features
|
Original
|
P9217
P9217
C3757-02
C3871
Non-c3750,
SE-171
KIRD1065E02
Hamamatsu PbS
|
PDF
|
C1103
Abstract: No abstract text available
Text: INFRARED DETECTOR PbS photoconductive detector P394 series, P2532-01, P2682-01 Infrared detectors utilizing photoconductive effects Features Applications l Room temperature operation Makes PbS cells useful in a wide range of applications including radiation thermometers and flame monitors
|
Original
|
P2532-01,
P2682-01
SE-171
KIRD1019E05
C1103
|
PDF
|
Untitled
Abstract: No abstract text available
Text: INFRARED DETECTOR PbS photoconductive detector P394 series, P2532-01, P2682-01 Infrared detectors utilizing photoconductive effects Features Applications l Room temperature operation Makes PbS cells useful in a wide range of applications including radiation thermometers and flame monitors
|
Original
|
P2532-01,
P2682-01
SE-171
KIRD1019E03
|
PDF
|
lockin amplifier
Abstract: pbs photoconductor lead selenide Model 289K 77058 70703
Text: 5.0 127 PbS @ 289K V /A -10 10 A G M E CO NS TA NT Photolithography N MI X MA D ME 2.06 (52) -11 10 PbSe @ 243K PbS @ 243K -12 6000 WAVELENGTH (nm) Fig. 1 NEP of PbS and PbSe Detectors. 1.25 (32) Dimensions in inches (mm) Excellent detectors for the 1 to 4.5 µm region
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: PREVIOUS DATA INFRARED DETECTOR PbS photoconductive detector P9217 series Room-temperature detectors capable of detecting up to 2.9 µm P9217 is a PbS photoconductive detector with greatly improved stability and resistance to high temperatures as compared with conventional types.
|
Original
|
P9217
C3757-02
SE-171
KIRD1065E03
KIRDA0181EA
|
PDF
|
max2501
Abstract: flame detector DETECTOR FLAME C3757-02 C3871 P9217 NEARL
Text: INFRARED DETECTOR PbS photoconductive detector P9217 Infrared detectors utilizing photoconductive effects P9217 is a PbS photoconductive detector with greatly improved stability and resistance to high temperatures when compared to conventional types. Features
|
Original
|
P9217
P9217
C3757-02
C3871
SE-171
KIRD1065E01
max2501
flame detector
DETECTOR FLAME
C3757-02
C3871
NEARL
|
PDF
|
Untitled
Abstract: No abstract text available
Text: PbS Photoconductive Cells Easy-to-Use Photoconductive Detectors with High Responsivity Over 3 ¡i m PbS cells make use of the photoconductive effect by which the elec trical resistance decreases with application of infrared radiation Operates at Room Tem perature
|
OCR Scan
|
KIRDB004BEA
KIRDB0049EA
KIRDB0050EA
|
PDF
|
Hamamatsu PbS
Abstract: No abstract text available
Text: INFRARED DETECTOR PbS photoconductive detector P2532-01, P2682-01 Infrared detectors utilizing photoconductive effects Features Applications l Room temperature operation Makes PbS cells useful in a wide range of applications including radiation thermometers and flame monitors
|
Original
|
P2532-01,
P2682-01
SE-171
KIRD1019E07
Hamamatsu PbS
|
PDF
|
pbs photoconductive
Abstract: p2532-01 photoconductive cells characteristic uv PHOTO detector C4696 P2682-01 A3179 A3179-01 C1103-04 C3757-02
Text: INFRARED DETECTOR PbS photoconductive detector P2532-01, P2682-01 Infrared detectors utilizing photoconductive effects Features Applications l Room temperature operation Makes PbS cells useful in a wide range of applications including radiation thermometers and flame monitors
|
Original
|
P2532-01,
P2682-01
SE-171
KIRD1019E07
pbs photoconductive
p2532-01
photoconductive cells characteristic
uv PHOTO detector
C4696
P2682-01
A3179
A3179-01
C1103-04
C3757-02
|
PDF
|
p2532-01
Abstract: flame detector uv light PHOTO detector C4696 DETECTOR FLAME P2682-01 A3179 A3179-01 C1103-04 C3757-02
Text: INFRARED DETECTOR PbS photoconductive detector P2532-01, P2682-01 Infrared detectors utilizing photoconductive effects Features Applications l Room temperature operation Makes PbS cells useful in a wide range of applications including radiation thermometers and flame monitors
|
Original
|
P2532-01,
P2682-01
SE-171
KIRD1019E06
p2532-01
flame detector
uv light PHOTO detector
C4696
DETECTOR FLAME
P2682-01
A3179
A3179-01
C1103-04
C3757-02
|
PDF
|
P9217-02
Abstract: No abstract text available
Text: INFRARED DETECTOR PbS photoconductive detector P9217 series Room-temperature detectors capable of detecting up to 2.9 µm P9217 is a PbS photoconductive detector with greatly improved stability and resistance to high temperatures as compared with conventional types.
|
Original
|
P9217
C3757-02
SE-171
KIRD1065E03
KIRDA0181EA
P9217-02
|
PDF
|
Untitled
Abstract: No abstract text available
Text: INFRARED DETECTOR PbS photoconductive detector P9217 series Room-temperature detectors capable of detecting up to 2.9 µm P9217 is a PbS photoconductive detector with greatly improved stability and resistance to high temperatures as compared with conventional types.
|
Original
|
P9217
C3757-02
P9217
P9217-02
P9217-03
P9217-04
SE-171
KIRD1065E03
|
PDF
|
C3757-02
Abstract: P9217 P9217-02 P9217-03
Text: INFRARED DETECTOR PbS photoconductive detector P9217 series Room-temperature detectors capable of detecting up to 2.9 µm P9217 is a PbS photoconductive detector with greatly improved stability and resistance to high temperatures as compared with conventional types.
|
Original
|
P9217
C3757-02
P9217
P9217-02
P9217-03
P9217-04
SE-171
KIRD1065E03
C3757-02
P9217-02
P9217-03
|
PDF
|
|
P394 series
Abstract: P394-22 p394 photo P4638 C4696 DETECTOR FLAME P2532-01 P2682-01 Hamamatsu PbS A3179-01
Text: INFRARED DETECTOR PbS photoconductive detector P394 series, P2532-01, P2682-01 Infrared detectors utilizing photoconductive effects Features Applications l Room temperature operation Makes PbS cells useful in a wide range of applications including radiation thermometers and flame monitors
|
Original
|
P2532-01,
P2682-01
SE-171
KIRD1019E05
P394 series
P394-22
p394 photo
P4638
C4696
DETECTOR FLAME
P2532-01
P2682-01
Hamamatsu PbS
A3179-01
|
PDF
|
Untitled
Abstract: No abstract text available
Text: INFRARED DETECTOR PbS photoconductive detector P2532-01, P2682-01 Infrared detectors utilizing photoconductive effects Features Applications l Room temperature operation Makes PbS cells useful in a wide range of applications including radiation thermometers and flame monitors
|
Original
|
P2532-01,
P2682-01
SE-171
KIRD1019E07
|
PDF
|
Glass Thermometers
Abstract: 15V temperature controller peltier peltier effect element 9x104
Text: PbS Photoconductive Cells Easy-to-Use Photoconductive Detectors with High Responsivity Over 3 jjl m PbS cells make use of the photoconductive effect by which the elec trical resistance decreases with application o f infrared radiation Operates at Room Temperature
|
OCR Scan
|
KIRDB0048EA
KIRDB0049EA
KIHDB0050EA
Glass Thermometers
15V temperature controller peltier
peltier effect element
9x104
|
PDF
|
Untitled
Abstract: No abstract text available
Text: INFRARED DETECTOR PbS photoconductive detector P9217 series Room-temperature detectors capable of detecting up to 2.9 µm P9217 is a PbS photoconductive detector with greatly improved stability and resistance to high temperatures as compared with conventional types.
|
Original
|
P9217
C3757-02
SE-171
KIRD1065E03
KIRDA0181EA
|
PDF
|
Untitled
Abstract: No abstract text available
Text: INFRARED DETECTOR PbS photoconductive detector P9217 series Room-temperature detectors capable of detecting up to 2.9 µm P9217 is a PbS photoconductive detector with greatly improved stability and resistance to high temperatures as compared with conventional types.
|
Original
|
P9217
C3757-02
P9217
P9217-02
P9217-03
P9217-04
SE-171
KIRD1065E03
|
PDF
|
P5168
Abstract: No abstract text available
Text: PbS Photoconductive Cells Easy-to-Use Photoconductive Detectors with High Responsivity Over 3 ¡u m PbS cells make use of the photoconductive effect by which the elec trical resistance decreases with application o f infrared radiation Operates at Room Temperature
|
OCR Scan
|
KIRDB0048EA
P5168
|
PDF
|
P3226
Abstract: P5168 P3226-02 G5832-05 P2682-01 P394 series Photodiode 2PIN TYPES G3476-01 G5832-02 P3258-02
Text: PbS Photoconductive Detectors Easy-to-use photoconductive detec tors with high responsivity over 3 jim • Operates at room temperature Since PbS cells operate stably at room temperature, they are used in a wide range of applications such as radiation thermometers and flame
|
OCR Scan
|
KIRDA0044EB
000M7D3
P2750,
C4159,
C4159-02
K1RDA004SEB
C5185,
C3757-02
D004704
P3226
P5168
P3226-02
G5832-05
P2682-01
P394 series
Photodiode 2PIN TYPES
G3476-01
G5832-02
P3258-02
|
PDF
|
pr 8501 b
Abstract: P394A P3226-02 P3226 PBS P394 series
Text: PbS Photoconductive Detectors Easy-to-use photoconductive detec tors with high responsivity over 3 jim • Operates at room temperature Since PbS cells operate stably at room temperature, they are used in a wide range of applications such as radiation thermometers and flame
|
OCR Scan
|
KI80A0055EA
0G0470
P394A,
P3226-02
P791-11
P3207-04
P4115
K1713-01,
K3413-01,
P3981-01,
pr 8501 b
P394A
P3226-02
P3226 PBS
P394 series
|
PDF
|
Untitled
Abstract: No abstract text available
Text: PbS Photoconductive Detectors Spectral Response Range: 1.0 to 3.6 n_m Easy-to-use photoconductive detectors with high responsivity over 3 jim •Room temperature operation Since PbS cells operate stably at room temperature, they are used in a wide range of applications such as radiation thermometers and flame
|
OCR Scan
|
KIRDB0050EA
|
PDF
|
Untitled
Abstract: No abstract text available
Text: PbS Photoconductive Detectors Easy-to-use photoconductive detec tors with high responsivity over 3 um • Operates at room temperature Since PbS cells operate stably at room tem perature, they are used in a w ide range o f applications such as radiation therm om eters and flam e
|
OCR Scan
|
KIRDB0048EA
KIRDB0049EA
KIRDB0050EA
KIRDC0005EA
|
PDF
|