Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    NH3 GAS Search Results

    NH3 GAS Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    EVAL-CN0357-PMDZ Analog Devices Toxic Gas Sensor. PMOD Visit Analog Devices Buy
    EVAL-CN0429-EBZ Analog Devices ADuCM355 Electrochemical Gas S Visit Analog Devices Buy
    EVAL-CN0357-ARDZ Analog Devices Toxic Gas Sensor Arduino shiel Visit Analog Devices Buy
    LTC2943IDD#PBF Analog Devices Multicell Bat Gas Gauge w/ Tem Visit Analog Devices Buy
    LTC2943CDD#TRPBF Analog Devices Multicell Bat Gas Gauge w/ Tem Visit Analog Devices Buy

    NH3 GAS Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    MQ-135

    Abstract: mq135 nh3 sensor NOx sensitivity characteristics to MQ135 MQ 135 Smoke sensor mq135 sensor Sensor MQ135 MQ 7 gas sensor AND PIN CONFIGURATION MQ 135 gas sensor co2 sensor circuit
    Text: TECHNICAL DATA MQ-135 GAS SENSOR FEATURES Wide detecting scope Fast response and High sensitivity Stable and long life Simple drive circuit APPLICATION They are used in air quality control equipments for buildings/offices, are suitable for detecting of NH3,NOx, alcohol, Benzene, smoke,CO2 ,etc.


    Original
    PDF MQ-135 800mw 100ppm 50ppm mq135 nh3 sensor NOx sensitivity characteristics to MQ135 MQ 135 Smoke sensor mq135 sensor Sensor MQ135 MQ 7 gas sensor AND PIN CONFIGURATION MQ 135 gas sensor co2 sensor circuit

    Untitled

    Abstract: No abstract text available
    Text: PRODUCTS TYPE POWER MODULE PAGE BP5890 < Specifications Precautions and Prohibitions > ● Precaution for Storage 1) Product performance and soldered connections may deteriorate if the products are stored in the following places: [a] Where the products are exposed to sea winds or corrosive gases, including Cl2, H2S, NH3, SO2,


    Original
    PDF BP5890 TSZ22111ï BP5890-A-001-E

    PHE-3211

    Abstract: No abstract text available
    Text: Ion Selective Electrode Electrode Ammonia NH3 Ammonium (NH4+) Model No. Price Housing Sensor Type ISE-8710 ISE-8711 ISE-8712 Bromide (Br -) ISE-8720 ISE-8722 Cadmium (Cd+2) ISE-8730 ISE-8732 Calcium (Ca+2) ISE-8740 ISE-8742 Carbon Dioxide (CO2) ISE-8750


    Original
    PDF ISE-8710 ISE-8711 ISE-8712 ISE-8720 ISE-8722 ISE-8730 ISE-8732 ISE-8740 ISE-8742 ISE-8750 PHE-3211

    SH-PB

    Abstract: chip resistor mounting
    Text: Resistors Operation notes !Cautions when handling resistors. 1. Oxidation will form on electrodes very easily. Store in the proper atmosphere Storage condition : 5~40°C, 30∼80% RH . And avoid to store in the environments full of sea breeze, H2S, Cl2, NO2, SO2, and NH3,


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Transmitters - GAS DETECTION DATASHEET AST Analog Transmitter technical drawing F I XE D S YS TE M DATA S H E E T sample engineering specifications Carbon Monoxide & Combustible Gas Transmitters for Parking Garages The rugged, reliable AST analog transmitter offers a variety of


    Original
    PDF R410A) R134A, R402A, R404A, R407C, R410A, R422A, R422D,

    TGS 826

    Abstract: sensor tgs nh3 sensor Figaro nh3 sensors TGS826 figaro TGS gas sensor tgs 8 gas sensor tgs-826 Figaro Engineering Figaro ammonia
    Text: FIGARO PRODUCT INFORMATION TGS 826 - for the Detection of Ammonia Features: Applications: * Ammonia leak detection in refrigerators * Ventilation control for the agricultural and poultry industries * High sensitivity to ammonia * Quick response to low concentrations of


    Original
    PDF TGS826 TGS826ity 50ppm 150ppm TGS 826 sensor tgs nh3 sensor Figaro nh3 sensors figaro TGS gas sensor tgs 8 gas sensor tgs-826 Figaro Engineering Figaro ammonia

    Figaro nh3 sensors

    Abstract: TGS 826 sensor tgs nh3 sensor tgs826 tgs-826 Figaro TGS 203 Figaro ammonia Figaro nh3 figaro sensor
    Text: FIGARO PRODUCT INFORMATION TGS 826 - for the Detection of Ammonia Features: Applications: * Ammonia leak detection in refrigerators * Ventilation control for the agricultural and poultry industries * High sensitivity to ammonia * Quick response to low concentrations of


    Original
    PDF TGS826 TGS826ity 50ppm 150ppm Figaro nh3 sensors TGS 826 sensor tgs nh3 sensor tgs-826 Figaro TGS 203 Figaro ammonia Figaro nh3 figaro sensor

    so2 sensor datasheet

    Abstract: 1000ppm BX-06 BX-07 gas sensor no2 H2S gas detector NO2 sensor BX-01 BX-04 BX-05
    Text: BX series detectors for toxic gas This series achieved state New Product award ◆ Explosion proof certification No:CNEx02.805 ◆ Explosion proof mark: ExiallCT4 ◆ Manufacture certification No.: Shaanxi 01000209 Features: ◆ Import sensor with stable & reliable performance


    Original
    PDF CNEx02 BX-01 BX-04 BX-05 BX-06 BX-07 BX-08 BX-09 BX-10 BX-11 so2 sensor datasheet 1000ppm BX-06 BX-07 gas sensor no2 H2S gas detector NO2 sensor BX-01 BX-04 BX-05

    ph meter circuit

    Abstract: TURBIDITY meter distillation ammonia ph probe distillation method
    Text: Data Sheet Ammonia Probe SS/8002_4 8002 • Fast and accurate response ■ Highly selective ■ Robust construction ■ Easy to use Applications The ammonia probe has been used in a wide range of applications including: Water – boiler water, river water and potable waters, sea water,


    Original
    PDF SS/8002 SS/8002 ph meter circuit TURBIDITY meter distillation ammonia ph probe distillation method

    Untitled

    Abstract: No abstract text available
    Text: GAS CONVERSION FACTORS For FMA-5600, FMA-5700 and FMA-8500 Flow Sensors The FMA-5600, FMA-700/800 , and FMA-8500 Electronic Mass Flowmeters and Controllers are factory calibrated for nitrogen, N2 . However, these units can be used for many gases, with the


    Original
    PDF FMA-5600, FMA-5700 FMA-8500 FMA-700/800 FMA-5600 FMA-8500 C4H10) FMA-8506

    Untitled

    Abstract: No abstract text available
    Text: Mid-IR Products Application in Gas Sensors Principle of Infrared Optical Absorption Analysis Infrared optical analysis is based on the vibrations of the atoms of a molecule. Infrared radiation passes through a sample and the fraction of the incident radiation that is absorbed at a particular


    Original
    PDF

    Capteur Sensors

    Abstract: nh3 sensor electrochemical gas sensors Capteur electrochemical gas sensors datasheet carbon monoxide sensor electrochemical sensor CO GS06 propane gas thick film co gas sensor
    Text: GS06 Ammonia Sensor SPECIFICATION 3x3 mm Standard Power GS06 Heater Resistance at 21°C KEY FEATURES Typical Value 10.6 ± 1Ω Heater Resistance at 410 ± 30°C Typical Value 13 ± 2Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH Typical Value 53 ± 5 kΩ


    Original
    PDF 100ppm 50ppm 25ppm Capteur Sensors nh3 sensor electrochemical gas sensors Capteur electrochemical gas sensors datasheet carbon monoxide sensor electrochemical sensor CO GS06 propane gas thick film co gas sensor

    ABB AO2020

    Abstract: AO2040 limas11 ABB AO2000 AO2040 uras26 gas module sensor Uras26 abb ao2040 Caldos25 magnos206 AO2020
    Text: Advance Optima Continuous Gas Analyzers AO2000 Series Models AO2020, AO2040 Data Sheet 10/24 1.20 EN February 2009 „ One central unit and various analyzer modules „ Menu-driven operator interface „ Clear-text status messages „ Multiple interfaces for communication with host and


    Original
    PDF AO2000 AO2020, AO2040 ABB AO2020 AO2040 limas11 ABB AO2000 AO2040 uras26 gas module sensor Uras26 abb ao2040 Caldos25 magnos206 AO2020

    helium sensor

    Abstract: AWM42150VH nitrogen gas sensor hydrogen and carbon monoxide gas sensor nitric oxide gas sensor gas sensor helium types methane gas sensor gas sensor no2 Transistor A131 helium gas sensor
    Text: REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Correction Factors – Note #3 Microbridge mass airflow sensors operate by measuring the rate of relative heat transfer from a heater resistor to a temperature sensing resistor located on either side of the heater. The


    Original
    PDF

    ABB AO2020

    Abstract: Uras14 AO2020 abb ao2040 ABB AO2000 AO2040 AO2000 AO2040 Limas11 gas analyzer 590 CALDOS
    Text: Continuous Gas Analyzers AO2000 Series Data Sheet 10/24 1.10 EN July 2007 „ One central unit and various analyzer modules „ Menu-driven operator interface „ Clear-text status messages „ Multiple interfaces for communication with host and – with common controls


    Original
    PDF AO2000 ABB AO2020 Uras14 AO2020 abb ao2040 ABB AO2000 AO2040 AO2040 Limas11 gas analyzer 590 CALDOS

    Untitled

    Abstract: No abstract text available
    Text: Product Specification Grace Inertia Connector 2.0 EV 108-106001 23MAR.’09 REV:E 1 Scope : 1.1 Contents This specification covers the requirements for product performance, test methods and quality assurance provisions of GIC 2.0 EV. Applicable product description and part numbers are as shown in Appendix 1.


    Original
    PDF 23MAR.

    Untitled

    Abstract: No abstract text available
    Text: PRODUCT INFORMATION GAS 86xyB May/2012 GAS 86xyB Digital Gas Sensor Platform Micronas’ multi-parametric sensor platform GAS 86xyB includes two CCFET Capacitive-Coupled Field-Effect Transistor gas detection devices, a temperature sensor, and a relative humidity sensor. Each sensor


    Original
    PDF 86xyB May/2012 86xyB PI000141 002EN D-79108 D-79008

    cl2 Gas sensor

    Abstract: Alphasense so2 sensor datasheet tds sensor gas sensor no2 NO2 sensor nh3 sensor hydrogen sulfide gas sensor c2h4 sensor gas sensor CO
    Text: α S H2S-BH Hydrogen Sulfide Sensor PATENT PENDING Technical Specification Figure 1 H2S-BH Schematic Diagram All dimensions in millimetres ± 0.1mm Top View Bottom View Side View Table 1 H2S-BH Specification PERFORMANCE Sensitivity Response time Zero current


    Original
    PDF 20ppm 20ppm TDS/H2SBH/1102 cl2 Gas sensor Alphasense so2 sensor datasheet tds sensor gas sensor no2 NO2 sensor nh3 sensor hydrogen sulfide gas sensor c2h4 sensor gas sensor CO

    Untitled

    Abstract: No abstract text available
    Text: Safety Precautions Common precautions for Fixed Resistors • When using our products, no matter what sort of equipment they might be used for, be sure to make a written agreement on the specifications with us in advance. The design and specifications in this catalog are subject


    Original
    PDF

    helium sensor

    Abstract: "Flow Sensor" AWM42000 hydrogen gas sensor AWM42150VH nh3 sensor gas sensor helium gas sensor no2 AWM42150VH application nitric oxide sensor
    Text: AWM42000 Series Mass flow sensor for gases FEATURES • Ranges 0.±25 and 0.±1000 sccm1 · Bidirectional sensing · Actual mass flow sensing · Ceramic flow tube · Manifold mount/o-ring sealed SERVICE To be used with dry gases only. The AWM42150VH is a special sensor for


    Original
    PDF AWM42000 AWM42150VH AWM42150VH AWM42300V helium sensor "Flow Sensor" hydrogen gas sensor nh3 sensor gas sensor helium gas sensor no2 AWM42150VH application nitric oxide sensor

    Alphasense

    Abstract: nitrogen dioxide sensor gas sensor no2 so2 sensor datasheet NO2-A1 ica 2100 NO2 sensor nitrogen gas sensor nh3 sensor
    Text: α S NO2-A1 Nitr og en Dio xide Sensor Nitrog ogen Dioxide PATENT PENDING Technical Specification Figure 1 NO2-A1 Schematic Diagram All dimensions in millimetres ± 0.1mm Top View Bottom View Side View Table 1 NO2-A1 Specification PERFORMANCE Sensitivity


    Original
    PDF 10ppm 200ppm, 100ppm TDS/SO2BF/1102 Alphasense nitrogen dioxide sensor gas sensor no2 so2 sensor datasheet NO2-A1 ica 2100 NO2 sensor nitrogen gas sensor nh3 sensor

    AWM43000

    Abstract: hydrogen gas sensor AWM43300V "Flow Sensor" hydrogen sensor helium sensor AWM43600V ch4 sensor methane carbon dioxide sensor nitrogen dioxide sensor
    Text: AWM43000 Series Mass flow sensor for gases FEATURES • Ranges 0.1000 sccm1 and 0.6 slpm2 · Actual mass flow sensing · 1.5 V output · Manifold mount/o-ring sealed SERVICE To be used with dry gases only The AWM series is NOT designed for liquid flow and will be damaged by liquid flow through


    Original
    PDF AWM43000 AWM43300V AWM43600V AWM43300VH hydrogen gas sensor AWM43300V "Flow Sensor" hydrogen sensor helium sensor AWM43600V ch4 sensor methane carbon dioxide sensor nitrogen dioxide sensor

    helium sensor

    Abstract: "Flow Sensor" LP GAS PRESSURE DEVICE SENSOR AWM700 medical Flow Sensor "Flow Sensor", medical AWM720P1 gas sensor helium liquid flow sensor Flow sensor
    Text: AWM700 Series Mass flow sensor for gases FEATURES • Ranges 0.200 slpm1 · Actual mass flow sensing · 1.5 V output SERVICE To be used with dry gases only The AWM series is NOT designed for liquid flow and will be damaged by liquid flow through the sensor


    Original
    PDF AWM700 AWM720P1 helium sensor "Flow Sensor" LP GAS PRESSURE DEVICE SENSOR medical Flow Sensor "Flow Sensor", medical AWM720P1 gas sensor helium liquid flow sensor Flow sensor

    Untitled

    Abstract: No abstract text available
    Text: REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Correction Factors - Note # 3 Microbridge mass airflow sensors operate by measuring the rate of relative heat transfer from a heater resistor to a temper­ ature sensing resistor located on either side of the heater. The


    OCR Scan
    PDF