Abstract: namur output DIN19234 IM12-02B-N-ZW0 IM12-04N-N-ZW0
Text: IM 12 NAMUR Inductive Proximity Sensors DC Highlights • Shielded or unshielded • Enclosure rating IP 67 • NAMUR to DIN 19 234 • LED status indicator • High switching frequency • Robust brass housing with nickel=plated fine thread M8 x 1 IM 12 NAMUR
|
Original
|
M12x1
IM12-02B-N-ZW0
IM12-04N-N-ZW0
Namur isolating switching amplifier
namur output
DIN19234
IM12-02B-N-ZW0
IM12-04N-N-ZW0
|
PDF
|
MQD9-415
Abstract: MIAD9DQ MIAD9D Quick disconnect QD connector Ex-94.C.7937 VOC sensor dc sensors MIAD9CVQ FM3610 40143
Text: MIAD9 Series NAMUR Intrinsically Safe DC Sensors* MIAD9 Series NAMUR Sensors are small, rugged, self-contained twowire sensors designed for use with approved switching amplifiers with intrinsically safe input circuits. MIAD9 Series sensors are designed in
|
Original
|
SMB312S
15-turn
MQD9-415
MIAD9DQ
MIAD9D
Quick disconnect QD connector
Ex-94.C.7937
VOC sensor
dc sensors
MIAD9CVQ
FM3610
40143
|
PDF
|
transistor BU 102
Abstract: bk 101 transistor SS TRANSISTOR DIN19234
Text: Proximity Sensors Inductive ABS Housing Type DU, Fork-shaped • Fork-shaped ABS housing • Slot sizes: 3.5, 5, 6, 10 mm • Power supply: 8.2 VDC NAMUR 24 VDC • Output: NAMUR (DIN 19234) Transistor NPN, make switching • Protection: Reverse polarity
|
Original
|
|
PDF
|
DIN19234
Abstract: Namur isolating switching amplifier IM18-05B-N-ZW0 namur output inductive proximity M18x1 IM18
Text: IM 18 NAMUR Inductive Proximity Sensors Highlights • NAMUR to DIN 19 234 • Enclosure rating IP 67 • Shielded or unshielded • LED status indicator NO function • Robust brass housing, nickel-plated with fine thread M18 x 1 mm • High switching frequency
|
Original
|
M18x1
IM18-05B-N-ZW0
IM18-08N-N-ZW0
DIN19234
Namur isolating switching amplifier
IM18-05B-N-ZW0
namur output
inductive proximity M18x1
IM18
|
PDF
|
EN50227
Abstract: Namur switching amplifier namur Namur isolating switching amplifier
Text: MM 18 NAMUR Magnetic Proximity Sensors Highlights • Sensing range up to 60 mm DC • High switching frequency • NAMUR to EN 50 227 • Shielded or unshielded • Robust brass housing, nickel-plated with fine thread M12 x 1 mm • Cable or connector • Enclosure rating IP 67
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Extract from the online catalog MINI MCR-SL-NAM-2RNO-SP Order No.: 2810269 Configurable NAMUR switching amplifier for proximity sensors, floating switching contacts and switching contacts with resistance circuit. On
|
Original
|
IF-2009)
|
PDF
|
PPCP
Abstract: transistor BU 210 SS TRANSISTOR namur npn transistors,pnp transistors transistor DJ marking transistor BU 110 NPCP dj bk
Text: Proximity Sensors Inductive ABS Housing Types DJ, Ø 77 and EI, Ø 77 • ABS housing, Ø 77 mm • Sensing distance: 40 mm • Power supply: 8.2 VDC NAMUR 24 VDC • Output: Namur (DIN 19234) Transistor NPN or PNP, make or break switching • Protection: Reverse polarity
|
Original
|
DJ40/EI
PPCP
transistor BU 210
SS TRANSISTOR
namur
npn transistors,pnp transistors
transistor DJ marking
transistor BU 110
NPCP
dj bk
|
PDF
|
TRANSISTOR 8040
Abstract: PPCP transistor su 110 transistor DJ marking
Text: Proximity Sensors Inductive ABS Housing Types DJ, Ø 50, Ø 77 and EI, Ø 77 • ABS housing, Ø 50 mm, Ø 77 mm • Sensing distance: 25 to 40 mm • Power supply: 8.2 VDC Namur 24 VDC • Output: Namur (DIN 19234) Transistor NPN, make switching (DJ 25 E)
|
Original
|
40/EI
TRANSISTOR 8040
PPCP
transistor su 110
transistor DJ marking
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Proximity Sensors Inductive ABS Housing Types DJ, Ø 50, Ø 77 and EI, Ø 77 • ABS housing, Ø 50 mm, Ø 77 mm • Sensing distance: 25 to 40 mm • Power supply: 8.2 VDC Namur 24 VDC • Output: Namur (DIN 19234) Transistor NPN, make switching (DJ 25 E)
|
Original
|
40/EI
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Isolating switching amplifier 2-channel IMC-Di-22Ex-PNO/24VDC The 2-channel isolating switching amplifier IMC-Di-22Ex-PNO/24VDC is equipped with intrinsically safe input circuits. Sensors according to EN 60947-5-6 NAMUR , variable resistances or potential-free
|
Original
|
IMC-Di-22Ex-PNO/24VDC
IMC-Di-22Ex-PNO/24VDC
2013-07-13T20
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Isolating switching amplifier 2-channel IMC-DI-22EX-PNC/24VDC The 2-channel isolating switching amplifier IMC-DI-22EX-PNC/24VDC is equipped with intrinsically safe input circuits. Sensors according to EN 60947-5-6 NAMUR , variable resistances or potential-free
|
Original
|
IMC-DI-22EX-PNC/24VDC
IMC-DI-22EX-PNC/24VDC
2013-07-13T20
D-45472
|
PDF
|
Im1-12EX
Abstract: No abstract text available
Text: Isolating switching amplifier 1-channel IM1-12EX-R The single-channel isolating switching amplifier IM1-12EX-R is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.
|
Original
|
IM1-12EX-R
IM1-12EX-R
D-45472
2013-07-13T20
Im1-12EX
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Isolating switching amplifier 2-channel IM12-22EX-R The dual-channel isolating switching amplifier IM12-22EX-R is equipped with intrinsically safe input circuits. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.
|
Original
|
IM12-22EX-R
IM12-22EX-R
D-45472
2013-07-13T20
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Isolating switching amplifier 2-channel IM1-22EX-MT The dual channel isolating switching amplifier IM1-22EX-MT is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.
|
Original
|
IM1-22EX-MT
IM1-22EX-MT
D-45472
2013-07-13T20
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Isolating switching amplifier 1-channel IM1-12EX-MT The single-channel isolating switching amplifier IM1-12EX-R is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.
|
Original
|
IM1-12EX-MT
IM1-12EX-R
D-45472
2013-07-13T20
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Isolating switching amplifier 1-channel IM1-121EX-T The single-channel isolating switching amplifier IM1-121EX-T is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.
|
Original
|
IM1-121EX-T
IM1-121EX-T
D-45472
2013-07-13T20
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Isolating switching amplifier 4-channel IM1-451EX-R The 4-channel isolating switching amplifier IM1-451EX-R is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.
|
Original
|
IM1-451EX-R
IM1-451EX-R
D-45472
2013-07-13T20
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Isolating switching amplifier 2-channel IM1-22EX-T The dual-channel isolating switching amplifier IM1-22EX-T is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.
|
Original
|
IM1-22EX-T
IM1-22EX-T
D-45472
2013-07-13T20
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Isolating switching amplifier 1-channel IM1-121EX-R The single-channel isolating switching amplifier IM1-121EX-R is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.
|
Original
|
IM1-121EX-R
IM1-121EX-R
D-45472
2013-07-13T20
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Isolating switching amplifier 4-channel IM1-451EX-T The 4-channel isolating switching amplifier IM1-451EX-T is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.
|
Original
|
IM1-451EX-T
IM1-451EX-T
D-45472
2013-07-13T20
|
PDF
|
Im1-12ex-t
Abstract: No abstract text available
Text: Isolating switching amplifier 1-channel IM1-12EX-T The 1-channel isolating switching amplifier IM1-12EX-T is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.
|
Original
|
IM1-12EX-T
IM1-12EX-T
D-45472
2013-07-13T20
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Isolating switching amplifier 2-channel IM1-22EX-R The dual-channel isolating switching amplifier IM1-22EX-R is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.
|
Original
|
IM1-22EX-R
IM1-22EX-R
D-45472
2013-07-13T20
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Isolating switching amplifier 2-channel IM12-22EX-R/230VAC The dual-channel isolating switching amplifier IM12-22EX-R/230VAC is equipped with intrinsically safe input circuits. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.
|
Original
|
IM12-22EX-R/230VAC
IM12-22EX-R/230VAC
D-45472
2013-07-13T20
|
PDF
|
Untitled
Abstract: No abstract text available
Text: 3 NAMUR Switching Amplifier V O LU M E 1 w ith transistor output Module width 20 mm / 0.787 in Ite m -N o . D escription P a c k . - u n it pcs N A M U R s w itc h in g a m p lif ie r w i t h t r a n s is to r o u t p u t 2 8 6 -8 8 1 NAMUR switching amplifier for the supply of
|