Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    NAMUR NE 21 Search Results

    NAMUR NE 21 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    KFD2-STC4-EX2

    Abstract: kfd2-stc4 abb SMART temperature Transmitter transmitter calibration certificate foxboro fisher-rosemount hazardous area Endress namur NE 21 BY260V
    Text: SMART Transmitter Power Supply KFD2-STC4-Ex2 - Input EEx ia IIC ? - DC 24 V power supply Input ΙΙ EEx ia IIC ? J J 2-wire transmitters - EMC per NAMUR NE 21 - LED per NAMUR NE 44 The SMART transmitter power supplies supply a 2-wire SMART transmitter within a


    Original
    PDF

    Siemens SN 29500

    Abstract: LIMIT SWITCH namur 43 LIMIT SWITCH namur application siemens CIB Namur switching amplifier ATEX* II 3D IEC 60947-5-6 namur NE 43 EXIDA
    Text: PI-EX-NAM/RNO-NE Ex-i NAMUR Isolation Amplifier INTERFACE Data Sheet 102883_04_en 1 PHOENIX CONTACT - 02/2008 Description The PI-EX-NAM/RNO-NE is a 3-way isolation amplifier. It is designed to operate proximity switches according to EN 60947-5-6 as well as switch contacts with open circuit


    Original
    PDF

    28353

    Abstract: EN61508
    Text: Extract from the online catalog PI-EX-NAM/RNO-NE Order No.: 2835341 Ex-i binary input: NAMUR isolation amplifiers. For operating proximity sensors and switches in Ex areas. The binary signals are transmitted


    Original
    PDF IF-2009) us35/7 28353 EN61508

    kfd2-sr-ex1

    Abstract: KFD2-SR2-EX1.W k-system namur NE 21 VDE 0812 PTB Switch Mode dc to ac Supply circuit DIN19234 EX-94
    Text: Transformer Isolated Barrier KF -SR2-Ex1.W Output: Relay - Control circuit EEx ia IIC Class I, Div 1, Groups A-G Switch S3 in position I 1+ - Reversible mode of operation 3- - 1 Signal output with 1 alternator - EMC per NAMUR NE 21 1+ Switch S3 in position I


    Original
    PDF

    kfd2-sr-ex2

    Abstract: KFA6-SR2-EX2.W kfd2 EX-94 KFD2-SR2-Ex2.W
    Text: Transformer Isolated Barrier KF Input ΙΙ - Control circuit EEx ia IIC Class I, Div 1, Groups A-G Switch S3 in position Ι - Reversible mode of operation 1+ 3- 4+ 6- - 1 Signal output with 1 alternator Switch S3 in position Ι - EMC per NAMUR NE 21 10 kΩ


    Original
    PDF

    kfd2-stc1-ex1

    Abstract: kfd2 fisher-rosemount Ex-94 namur NE 93 namur NE 21 STT01 ST-T01 bailey transmitter abb SMART temperature Transmitter
    Text: SMART Transmitter Power Supplies Hazardous area KFD2-ST*1-Ex1* Input EEx ia IIC SMART transmitter SMART communicator 1-channel Input EEx ia IIC; U0 = 28V 24 V DC nominal supply voltage SMART capable up to 12 kHz -1 dB EMC acc. to NAMUR NE 21 1+ 3- 1+ + -


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Data Sheet FieldIT PF 900-NR Power Feed Module Features and Benefits • 24 V DC supply voltage ■ Supply current ≤ 4 A ■ Bus access via terminals ■ Redundant supply ■ Fault signal output with adjustable mode of operation ■ EMC acc. to NAMUR NE 21


    Original
    PDF 900-NR 3BDD011868R101

    kfd2-stc4

    Abstract: BAS 99 ATEX 7060 kfd2-stc4-ex1 bas99 EN50-020 atex 7060 kfd2-eb2 61508 UPR-03 EN 50014 to 50020
    Text: KFD2-STC4-Ex1 SMART transmitter power supply Connection • 1-channel • Device installation permissible in zone 2 • Input EEx ia IIC; Uo = 25.4 V • Galvanically isolated output • 24 V DC supply voltage • SMART capable up to 7.5 kHz -3 dB • EMC acc. to NAMUR NE 21


    Original
    PDF PR-03 UPR-03 kfd2-stc4 BAS 99 ATEX 7060 kfd2-stc4-ex1 bas99 EN50-020 atex 7060 kfd2-eb2 61508 EN 50014 to 50020

    Untitled

    Abstract: No abstract text available
    Text: Extract from the online catalog PI-EX-NAM/RNO-NE Order No.: 2835341 Ex-i binary input: NAMUR isolation amplifiers. For operating proximity sensors and switches in Ex areas. The binary signals are transmitted to a safe area. Relay output N/O contact , line fault detection.


    Original
    PDF IF-2009)

    KFA6-SR2-Ex2.W

    Abstract: IEC 60947-5-6 KFD2-SR2-Ex2.W KFa5-SR2-Ex2.W kfd2-sr-ex2 atex transformer E 106378 60947-5-6 namur standard kfa5-sr2
    Text: Transformer Isolated Barriers Input I EEx ia IIC Input II EEx ia IIC 1+ 3- 4+ 3- 4+ 3- 4+ 3- 4+ Switch S3 in position I 2-channel Control circuit EEx ia IIC Reversible mode of operation 1 signal output with 1 changeover contact per channel • EMC acc. to NAMUR NE 21


    Original
    PDF

    EX-94

    Abstract: kha6-sr2-ex KHA6 namur NE 21 KHA6-SR2-Ex1.W KHA5-S kfd2-sr-ex1 KFD2-SR2-EX1.W DIN19234 KFA5
    Text: P R O Z E S S A U T O M A T I O N Trennschaltverstärker K -SR2-Ex1.W Ausgang: Relais Eingang EEx ia IIC - 1-kanalig - Steuerstromkreis EEx ia IIC 1+ 3- - 1 Signalausgang mit 1 Wechsler - EMV gemäß NAMUR NE 21 Schalter S3 in Pos. I 10 kΩ 1+ 3- KFD2-SR2-Ex1.W


    Original
    PDF Signalgebe50 EX-94 kha6-sr2-ex KHA6 namur NE 21 KHA6-SR2-Ex1.W KHA5-S kfd2-sr-ex1 KFD2-SR2-EX1.W DIN19234 KFA5

    kha6-sr2-ex

    Abstract: namur NE 21 KFD2-SR2-Ex2.W KFA6-SR2-EX2.W kfd2-sr-ex2 Ex-94 VDE 0812 PTB VDE 0812 S KHA5-S lb 7610
    Text: P R O Z E S S A U T O M A T I O N Trennschaltverstärker K - 2-kanalig Eingang Ι EEx ia IIC -SR2-Ex2.W Ausgang: Relais Eingang ΙΙ EEx ia IIC - Steuerstromkreis EEx ia IIC - 1 Signalausgang mit 1 Wechsler je Kanal 1+ 3- 4+ 6Schalter S3 in Pos. Ι - EMV gemäß NAMUR NE 21


    Original
    PDF

    DW-AD-403-04

    Abstract: DW-AD-401-04 detecteur de proximite inductif DW-AD-404-04 DW-AD-402-04 DW-AS-401-04 DW-AS-402-04 DW-AS-404-04 Contrinex namur DW-AS-405-04
    Text: data sheet Induktiver Näherungsschalter Détecteur de proximité inductif Inductive Proximity Switch DW - A - 40 - 04 Durchmesser Diamètre Diameter 4 mm Miniaturausführung Durchmesser 4 mm glatt Appareil miniature Boîtier lisse de 4 mm de diamètre Wichtigste Eigenschaften:


    Original
    PDF

    DIN19240

    Abstract: zener diode 5.6 V
    Text: Module no:2940799 LabelId:2940799 Operator:Phoenix 18:15:56, Donnerstag, 28. Juni 2001 EIK 1-SVN. for inductive proximity sensors 1 in accordance with NAMUR Terminal width 6.2 Enclosed housing “.6” M3 8 IEC) rigid flexible 2 [mm ] solid stranded AWG


    Original
    PDF 801-2/EN DIN19240 zener diode 5.6 V

    KFD2-SR2-Ex2.W

    Abstract: IEC 60947-5-6 NE44 kfd2-eb2 60947-5-6 kfd2 atex transformer Pepperl Fuchs kfd2 Ignition Transformer namur standard
    Text: Transformer Isolated Barriers KFD2-SR2-Ex2.W Output: Relay Input I EEx ia IIC Input II EEx ia IIC 1+ 4+ 6- 400 Ω ≤ R ≤ 2 kΩ 10 kΩ 3- Switch S3 in position I 10 kΩ 4+ 6- Switch S3 in position I 24 V DC: without SC • • • • 2-channel Control circuit EEx ia IIC


    Original
    PDF

    pbt-gf20 relay

    Abstract: PA-GF20 BI50-Q80-ADZ30X2-B1131 Ni10-Q25-AN6X M160160 2-Q12-AN6X Lucas Ni15-Q30-AP6X Ni25-Q20-AP6X2-H1141 4-Q12-AP6X
    Text: Selection Guide Housing Styles Pages Q5.5 Style 2-Wire DC 3-Wire DC 7-8 9 - 10 Q06 Style 3-Wire DC 11 - 12 Housing Styles Pages Q11S Style 2-Wire DC 3-Wire DC 2-Wire NAMUR 7-8 23 - 24 45 - 46 25 - 26 37 - 38 Q6.5 and Q9.5 Styles 3-Wire DC 13 - 14 Q12 Style


    Original
    PDF B9005 1-800-544-PROX B0143 pbt-gf20 relay PA-GF20 BI50-Q80-ADZ30X2-B1131 Ni10-Q25-AN6X M160160 2-Q12-AN6X Lucas Ni15-Q30-AP6X Ni25-Q20-AP6X2-H1141 4-Q12-AP6X

    pt100 rtd rosemount

    Abstract: pt 100 temperature sensor RTD abb PT-100 RTD 4 wire sensor - rosemount rosemount pt 100 rtd rosemount PT-1000 sensor PT-100 RTD 3 wire sensor - rosemount PT-100 RTD 3 wire sensor rosemount PT100 rosemount PT-100 RTD 4 wire sensor rosemount th102
    Text: FieldIT Data Sheet 10/11 8.54 EN Temperature Transmitter, rail mounted TH102/TH102-Ex HART programmable, Pt 100 RTD , thermocouples, electrical isolation Level 0: Information • Input – Resistance thermometer (2, 3, 4 wire circuit) – Thermocouples – Resistance remote signalling unit (0.5000 Ω)


    Original
    PDF TH102/TH102-Ex pt100 rtd rosemount pt 100 temperature sensor RTD abb PT-100 RTD 4 wire sensor - rosemount rosemount pt 100 rtd rosemount PT-1000 sensor PT-100 RTD 3 wire sensor - rosemount PT-100 RTD 3 wire sensor rosemount PT100 rosemount PT-100 RTD 4 wire sensor rosemount th102

    encodeur incremental

    Abstract: TRANSISTOR SUBSTITUTION Convertisseur Tension Frequence MCR-F-UI-DC Conector N macho convertidor de frecuencia transitor engranaje BU 2525 AF analogique
    Text: Phoenix Contact GmbH & Co. KG D-32823 Blomberg, Germany Fax +49- 0 5235-341200, Tel. +49-(0)5235-300 www.interface.phoenixcontact.com D GB TNR 9000681-03 / 04.2003 Universal Frequenz-Messumformer Universal Frequency Transducer F Convertisseur de fréquences


    Original
    PDF D-32823 CISPR11 encodeur incremental TRANSISTOR SUBSTITUTION Convertisseur Tension Frequence MCR-F-UI-DC Conector N macho convertidor de frecuencia transitor engranaje BU 2525 AF analogique

    namur standard

    Abstract: NCB5-18GM40-N0 60947-5-6 en steel series
    Text: NCB5-18GM40-N0 Inductive proximity switches Comfort series 5 mm embeddable 37 40 4 M18x1 24 LED Reduction factor rAl 0.35 Reduction factor rCu 0.3 Nominal voltage Uo Current consumption Measuring plate detected Measuring plate not detected Switching frequency f


    Original
    PDF NCB5-18GM40-N0 M18x1 namur standard NCB5-18GM40-N0 60947-5-6 en steel series

    rosemount 1144

    Abstract: rosemount pt 100 rtd V11523 pt100 rtd rosemount PT100 rosemount EC certificate PTB ATEX 1144 X Thermocouple Type L namur NE 43 rosemount PT 441 rosemount PT-1000 sensor
    Text: FieldIT Data Sheet 10/11 8.64 EN Temperature Transmitter, field mounted TH202/TH202-Ex HART programmable, Pt 100 RTD , thermocouples, electrical isolation Level 0: Information • Input – Resistance thermometer (2, 3, 4 wire circuit) – Thermocouples – Resistance remote signalling unit (0.5000 Ω)


    Original
    PDF TH202/TH202-Ex rosemount 1144 rosemount pt 100 rtd V11523 pt100 rtd rosemount PT100 rosemount EC certificate PTB ATEX 1144 X Thermocouple Type L namur NE 43 rosemount PT 441 rosemount PT-1000 sensor

    phoenix contact 24v 8 channel Relay

    Abstract: ATEX EN50082-2
    Text: Two-Channel Switch Amplifier With Relay Output, 24 V DC Power Supply PI/Ex-ME-2NAM/COC-24 V DC 1. Modular Electronic Interface for Process Technology Process systems are characterized by a large number of signals. A large proportion of these signals are Ex-i signals, which are not always routed. In this


    Original
    PDF PI/Ex-ME-2NAM/COC-24 phoenix contact 24v 8 channel Relay ATEX EN50082-2

    mcr 100a

    Abstract: ATEX
    Text: Two-Channel Switch Amplifier With Relay Output 230 V AC Power Supply PI/Ex-ME-2NAM/COC-230 V AC 1. Modular Electronic Interface for Process Technology Process systems are characterized by a large number of signals. A large proportion of these signals are Ex-i signals, which are not always routed. In this


    Original
    PDF PI/Ex-ME-2NAM/COC-230 mcr 100a ATEX

    namur NE 21

    Abstract: MF740 DIN19234 kfd2-sr-ex2 la 7610
    Text: A U T O M A T I O N C Transformer Isolated Barrier KFD2-SR2-Ex2.W _Output: Relay € - Dual Channel Input I EEx ia IIC Input II EEx ia IIG - Hazardous Field Circuit EEx ia MC and Class I, Div 1, Groups A-G - DC 24 V Nominal Power Supply


    OCR Scan
    PDF 14AWG) namur NE 21 MF740 DIN19234 kfd2-sr-ex2 la 7610

    Ex-94

    Abstract: kfd2-sr-ex1 KFD2-SR2-EX1.W khd2-sr namur NE 21 DIN19234
    Text: C Transformer Isolated Barrier KFD2-SR2-Ex1.W _Output: Relay € - Single Channel Input EEx ia IIC - Hazardous Field Circuit EEx ia IIC and Class I, Div 1,Groups A-G - DC 24 V Nominal Power Supply ra 1+ - Selectable Mode of Operation


    OCR Scan
    PDF 14AWG) Ex-94 kfd2-sr-ex1 KFD2-SR2-EX1.W khd2-sr namur NE 21 DIN19234