Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    MSR210P Search Results

    MSR210P Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    440R-H23180

    Abstract: IEC60947-4-1 MSR230P IEC 60947-4-1 IEC 60947-5-1 msr210p 60947-5-1 AS4024 B300 EN954-1
    Text: Safety Relays Modular Monitoring Safety Relays Minotaur MSR230P Specifications Description The MSR230P is an output expansion module for the modular Minotaur MSR200 family of monitoring safety relays. It can be connected to either the MSR210P or MSR211P base unit to provide


    Original
    MSR230P AS4024 EN954-1 ISO13849-1) IEC60947-4-1 MSR230P MSR211P 440R-H23180 IEC60947-4-1 IEC 60947-4-1 IEC 60947-5-1 msr210p 60947-5-1 B300 EN954-1 PDF

    msr220p

    Abstract: MSR210P 440R-H23179 MSR221 AS4024 MSR221P msr20 MSR211P ISO13849-1 S12-S32
    Text: Safety Relays Modular Monitoring Safety Relays Minotaur MSR221P Specifications Description The MSR221P is an input expansion module for the modular Minotaur MSR200 family of monitoring safety relays. It can be connected to either the MSR210P or MSR211P to provide


    Original
    MSR221P IEC/EN60204-1, ISOTR12100, ISO13849-1 AS4024 MSR221P MSR200 MSR210P MSR211P 1300ohms msr220p 440R-H23179 MSR221 msr20 ISO13849-1 S12-S32 PDF

    rs485 protocol

    Abstract: msr20 rs485 MSR210P MSR230 rs232 protocols RS232 bus MSR211P EN60204-1 440R-H23183
    Text: Safety Relays Modular Monitoring Safety Relays Minotaur MSR240P Specifications Description The MSR240P is a communications module for the modular Minotaur MSR200 family of monitoring safety relays. It can be connected to either the MSR210P or MSR211P base unit to provide


    Original
    MSR240P IEC/EN60204-1, ISOTR12100 RS232 RS485 MSR240P 440R-H23181 440R-H23182 rs485 protocol msr20 rs485 MSR210P MSR230 rs232 protocols RS232 bus MSR211P EN60204-1 440R-H23183 PDF

    440r-h23176

    Abstract: MSR210P 2 input and gate 24v Y31-Y32 msr20 B300 DC-13 EN954-1 ISO13849-1 P300
    Text: Safety Relays Modular Monitoring Safety Relays Minotaur MSR210P Category Description The MSR210P forms one of the base units for the modular Minotaur MSR200 family of monitoring safety relays. It can be combined with other modules of the MSR200 Series to configure a


    Original
    MSR210P EN954-1 ISO13849-1) 1300ohms 3200ohms MSR210P MSR200 Y40/Y41/Y42 440r-h23176 2 input and gate 24v Y31-Y32 msr20 B300 DC-13 EN954-1 ISO13849-1 P300 PDF

    440N-Z2NRS1A

    Abstract: 440N-Z2NRS1C 440NZ2NRS1B 440N-Z21W1PH 440N-Z21W1PA 440N-Z21W1PB 440R-W23219 440R-N23132 440r-h23176 MSR127TP
    Text: Safety Switches Non-Contact Switches Magnetically Coded Specifications MC1 MC2 Safety Ratings EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC609475-1, IEC/EN60947-5-3, ANSI B11.19, AS4024.1 Safety Classification Cat. 1 device per EN 954-1 dual channel


    Original
    EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC609475-1, IEC/EN60947-5-3, AS4024 889D-F4ACDM- 440N-Z2NRS1A 440N-Z2NRS1C 440NZ2NRS1B 440N-Z21W1PH 440N-Z21W1PA 440N-Z21W1PB 440R-W23219 440R-N23132 440r-h23176 MSR127TP PDF

    50022-35

    Abstract: msr20 en 50022-35 msr210p MSR245 MSR245P MSR200
    Text: Safety Relays Modular Monitoring Safety Relays Minotaur MSR245P Specifications Description The MSR245P is a display module for the modular Minotaur MSR200 family of monitoring safety relays. The MSR245P Display Module is interfaced to an MSR200 system through an MSR240P


    Original
    MSR245P IEC/EN60204-1, ISOTR12100 RS232 MSR230P MSR210P MSR240P 50022-35 msr20 en 50022-35 msr210p MSR245 MSR245P MSR200 PDF

    440J-N21TNPM-NP

    Abstract: MSR127TP 440r-h23176 889D-F8AB 440J-N21TNPH-NP 440R-N23132 msr127t 440R-W23219 440R-N23135 440J-N21TNPM
    Text: Operator Interface Enabling Switches Overview ? Enabling devices are typically used when access to the hazardous portion of the machine is needed while the machine is running. Visual observations, minor adjustments, troubleshooting, calibration, tool changes, and lubrication are examples of tasks that may utilize


    Original
    PDF

    msr220p

    Abstract: 440R-H23179 MSR200 MSR211
    Text: Modular Safety Monitoring Relays specifications Q_ I C€ MinotaurMSR221P The MSR221P is an input expansion module for the modular M inotaur MSR200 family o f m onitoring safety relays. It can be connected to either the MSR210P or MSR211P to provide additional


    OCR Scan
    IEC/EN60204-I, 1300ohms 2S00V 43lbin) MinotaurMSR221P 440R-H23179 MSR22IP msr220p MSR200 MSR211 PDF

    440R-H23180

    Abstract: No abstract text available
    Text: specifications Modular Safety Monitoring Relays Standards IE C / E N 6 0 2 0 4 -I, IS O T R I2 IO O , IS O 13849-1 E N 9 S 4 - I £_ Q_ I C€ 2 4 V D C from the base unit P ow er Consum ption I. 5 W Fuses 6 A Slo w Blow o r 10 A Q u ic k Blow O u tp u t (external)


    OCR Scan
    A/24V 43lbin) 47lbs) A/375VA 440R-H 440R-H23180 PDF

    RS48S

    Abstract: MSR245
    Text: specifications Modular Safety Monitoring Relays £_ Q_ I cc The MSR240P is connected in place of the terminator plug to the free bus connector of the Basic Module or the last connected Expansion Module, depending on the system configuration. Data transfer and


    OCR Scan
    IEC/EN60204-I, RS232 RS48S 43lbin) 20lbs) MinotaurMSR240P MSR240P RS485 440R-H23181 MSR245 PDF