Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    MIL C 26482 Search Results

    MIL C 26482 Result Highlights (1)

    Part ECAD Model Manufacturer Description Download Buy
    DBM25P743C Amphenol Communications Solutions D-sub military 25 way Pin right angle Visit Amphenol Communications Solutions
    SF Impression Pixel

    MIL C 26482 Price and Stock

    TE Connectivity 611053-10

    Standard Circular Connector
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 611053-10 Each 323 1
    • 1 $33.83
    • 10 $33.83
    • 100 $33.83
    • 1000 $33.83
    • 10000 $33.83
    Buy Now

    Amphenol Corporation 10-572952-06P

    Circular MIL Spec Connector 6P BOX MT PIN RECPT SZ 10 MIL-C-26482 I
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 10-572952-06P Each 757 1
    • 1 $40.75
    • 10 $40.75
    • 100 $40.75
    • 1000 $40.75
    • 10000 $40.75
    Buy Now

    TE Connectivity 611053-18

    Standard Circular Connector
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 611053-18 Each 310 1
    • 1 $40.18
    • 10 $40.18
    • 100 $40.18
    • 1000 $40.18
    • 10000 $40.18
    Buy Now

    TE Connectivity 611053-14

    Standard Circular Connector
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 611053-14 Each 1,858 1
    • 1 $39.39
    • 10 $39.39
    • 100 $39.39
    • 1000 $39.39
    • 10000 $39.39
    Buy Now

    Glenair Inc 660-008NF12G7-05

    Circular MIL Spec Tools, Hardware & Accessories Plug Cover Size 12 NylonRopeMIL-C-26482
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 660-008NF12G7-05 Each 41 1
    • 1 $150.25
    • 10 $141.54
    • 100 $65.44
    • 1000 $65.44
    • 10000 $65.44
    Buy Now

    MIL C 26482 Datasheets (1)

    Part ECAD Model Manufacturer Description Curated Type PDF
    MIL-C-26482 ITT Industries Series 2 Connectors PV Original PDF

    MIL C 26482 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Untitled

    Abstract: No abstract text available
    Text: MIL-C 26482 SERIES 1 CRIMP MIL-C 26482 SERIES I CRIMP MIL-C 26482 SERIES I CRIMP MIL-C 26482 SERIES I CRIMP MIL-C 26482 SERIES I CRIMP MIL-C 26482 SERIES I CRIMP MIL-C 26482 SERIES I CRIMP MIL-C 26482 SERIES I CRIMP MIL-C 26482 SERIES I CRIMP MIL-C 26482 SERIES I CRIMP


    Original
    PDF

    M37x1.0

    Abstract: endbell PAN6432-2 ln29504 PAN6432-1 MIL-C-2607 M28X1.0 FED-STD-H28 pan6432 MIL-C-81703
    Text: Sigmaform Backshells Sigmaform Backshells Reference Information Table I - Connector Designator Reference Code Table - Sigmaform Backshells Only Desig. A B C Specification MIL-C-5015 Mates To Endbell, V Threads MIL-C-5015 "D" Classes A, E & R MIL-C-5015 MIL-C-26482


    Original
    PDF MIL-C-5015 MIL-C-26482 MIL-C-81703 MIL-C-83723 40M39569 DEF5326-3 LN29504 NFC93422 M37x1.0 endbell PAN6432-2 ln29504 PAN6432-1 MIL-C-2607 M28X1.0 FED-STD-H28 pan6432 MIL-C-81703

    MIL-C-26482

    Abstract: 93c46li
    Text: EPIC MIL-C MIL-C-26482 CPT SERIES MINATURE BAYONET FIT


    Original
    PDF MIL-C-26482 MIL-C-26482 93c46li

    Interface Standards and Connector Designators

    Abstract: HE302
    Text: Conduit Introduction Conduit Backshells, Fittings and Adapters Interface Standards and Connector Designators Conduit Adapter Interface Standards A Desig. A Spec. MIL-C-5015 MIL-C-26482 MIL-C-81703 MIL-C-83723 40M39569 DEF 5326-3 EN 2997, 3646 ESC 10, 11 LN 29504


    Original
    PDF MIL-C-5015 MIL-C-26482 MIL-C-81703 MIL-C-83723 40M39569 NFC93422 MS3400 HE302 MIL-C-22992 Interface Standards and Connector Designators HE302

    nas1653

    Abstract: MS3476 back shell ms3116 backshell ms3187-16 ms3187 MS3476 tool NAS1650 MS3474 MS3187-20 MS3470 backshell
    Text: MIL-C-26482, Series 2 Connectors PV • Intermatable with MIL-C-26482 Series I • Operating termperature - 55˚C to + 200˚C The PV connector is designed to meet the rugged requirements of MIL-C-26482, Series 2/MIL-C-83723 Series I*, the specification which delineates


    Original
    PDF MIL-C-26482, MIL-C-26482 2/MIL-C-83723 nas1653 MS3476 back shell ms3116 backshell ms3187-16 ms3187 MS3476 tool NAS1650 MS3474 MS3187-20 MS3470 backshell

    MS3476 back shell

    Abstract: NAS1653 MS3187-20 ms3116 backshell viking GG 190 NAS1650 MS34745 MS3187-12 MS3476 tool NAS1699
    Text: MIL-C-26482, Series 2 Connectors PV • Intermatable with MIL-C-26482 Series I • Operating termperature - 55˚C to + 200˚C The PV connector is designed to meet the rugged requirements of MIL-C-26482, Series 2/MIL-C-83723 Series I*, the specification which delineates


    Original
    PDF MIL-C-26482, MIL-C-26482 2/MIL-C-83723 MS3476 back shell NAS1653 MS3187-20 ms3116 backshell viking GG 190 NAS1650 MS34745 MS3187-12 MS3476 tool NAS1699

    NAS1652

    Abstract: NAS1599 connector ms3116 backshell MS3126 tool NAS1650
    Text: MIL-C-26482, Series 2 Connectors PV • Intermatable with MIL-C-26482 Series I • Operating termperature - 55˚C to + 200˚C The PV connector is designed to meet the rugged requirements of MIL-C-26482, Series 2/MIL-C-83723 Series I*, the specification which delineates


    Original
    PDF MIL-C-26482, MIL-C-26482 2/MIL-C-83723 MS3476 MS3472 MS3475 MS3470 MS3474 NAS1652 NAS1599 connector ms3116 backshell MS3126 tool NAS1650

    ms3406

    Abstract: MIL-C-81703 MS3467 MS3401 ms3400 MIL-C-5015 ms3406 MS3404 ms3454 MS3456 equivalent MS3456
    Text: Adapter Products Code 54 MIL-C-5015 MS3400 , MIL-C-26482 Series 2, MIL-C-83723 Series I and III, MIL-C-81703 Series III Braided Adapters 152.4 [6.00] Min. Z Dia. Y Dia. 203M0XX-XXXXX W C D Z Dia. 152.4 Min. [6.00] E Z Dia. Y Dia. 203M1XX-XXXXX Y Dia. 203M2XX-XXXXX


    Original
    PDF MIL-C-5015 MS3400) MIL-C-26482 MIL-C-83723 MIL-C-81703 203M0XX-XXXXX 203M1XX-XXXXX 203M2XX-XXXXX MIL-C-81703 ms3406 MS3467 MS3401 ms3400 MIL-C-5015 ms3406 MS3404 ms3454 MS3456 equivalent MS3456

    MIL-DTL-26482

    Abstract: No abstract text available
    Text: MIL-DTL-26482 Connectors 240-264W MIL-DTL-26482 Series II Type Wall Mount Receptacle Contact Gender P - Pin S - Socket MIL-C-26482 Series II Filter Connector Product Code B Filter Type P - Pi Circuit C - C Circuit Insert Arrangement Per MIL-STD-1669 240 - 264


    Original
    PDF MIL-DTL-26482 40-264W MIL-DTL-26482 MIL-C-26482 MIL-STD-1669

    Glenair 447

    Abstract: mil-std-1669 MIL-DTL-26482 240-264J MIL-DTL-26482 SERIES CONNECTOR
    Text: MIL-DTL-26482 Connectors 240-264J MIL-DTL-26482 Series II Type Filter Connector Jam Nut Receptacle Contact Gender P - Pin S - Socket MIL-C-26482 Series II Filter Connector Product Code B Filter Type P - Pi Circuit C - C Circuit Insert Arrangement Per MIL-STD-1669


    Original
    PDF MIL-DTL-26482 240-264J MIL-DTL-26482 MIL-C-26482 MIL-STD-1669 Glenair 447 mil-std-1669 240-264J MIL-DTL-26482 SERIES CONNECTOR

    Untitled

    Abstract: No abstract text available
    Text: MIL-DTL-26482 Connectors 240-264W MIL-DTL-26482 Series II Type Wall Mount Receptacle Contact Gender P - Pin S - Socket MIL-C-26482 Series II Filter Connector Product Code Filter Type P - Pi Circuit C - C Circuit Insert Arrangement Per MIL-STD-1669 B 240 - 264


    Original
    PDF MIL-DTL-26482 40-264W MIL-DTL-26482 MIL-C-26482 MIL-STD-1669

    Untitled

    Abstract: No abstract text available
    Text: MIL-DTL-26482 Connectors 240-264W MIL-DTL-26482 Series II Type Wall Mount Receptacle Contact Gender P - Pin S - Socket MIL-C-26482 Series II Filter Connector Product Code B Filter Type P - Pi Circuit C - C Circuit Insert Arrangement Per MIL-STD-1669 240 - 264


    Original
    PDF MIL-DTL-26482 MIL-C-26482 40-264W MIL-STD-1669

    MIL-PRF-24758-53

    Abstract: No abstract text available
    Text: MIL-PRF 24758A MIL-PRF-24758-53 Adapter for MIL-C-26482 Series I Connectors User Installable for Glenair MIL-PRF-25758 Conduit Connector Designator Basic Number A Angular Function H = 45° J = 90° S = Straight D = MIL-C-26482, Series I Table I M24758-53


    Original
    PDF 4758A MIL-PRF-24758-53 MIL-C-26482 MIL-PRF-25758 MIL-C-26482, M24758-53 M24758-* MIL-PRF-24758-53

    MS3115

    Abstract: 650DS001 series 65
    Text: 65 650DS001 Dummy Stowage Receptacle - Bayonet MIL-C-26482 and MIL-C-83723 Series I 650DS001 B 16 MIL-C-26482 MIL-C-83723 Series I Bayonet Basic Part No. Finish Table IV Shell Size F Gasket G E H K J Shell Size 08 10 12 14 16 18 20 22 24 E Dia .471 (12.0)


    Original
    PDF 650DS001 MIL-C-26482 MIL-C-83723 650DS001 MIL-C-26482 MIL-C-83723 MS3115. MS3115 series 65

    Untitled

    Abstract: No abstract text available
    Text: ca_A1-A163.qxd:Layout 1 2/9/11 7:48 PM Page 1 ca_A1-A163.qxd:Layout 1 2/9/11 7:49 PM Page 63 PV MIL-C-26482, Series 2 Connectors • Intermatable with MIL-C-26482 Series I • Operating temperature – 55 C to + 200 C The PV Connector is designed to meet the rugged requirements of MIL-C-26482, Series 2/MIL-C-83723 Series I*, the


    Original
    PDF A1-A163 MIL-C-26482, MIL-C-26482 2/MIL-C-83723 MS27488-20-2 MS27488-16-2 MS27488-12-2

    Untitled

    Abstract: No abstract text available
    Text: φ F722 105 000 TECHNICAL DATA SHEET Séries Termini Title: Socket terminus Size 16 Issue Page Mar 09 2006 1/1 Dimensions : mm GENERAL Type: Termini #16 Mil-T-29504/11 Socket contact with ceramic ferrule and sleeve for MIL-C-83723 series 1, 3, MIL-C-83733 and MIL-C-26482 serie 2.


    Original
    PDF Mil-T-29504/11) MIL-C-83723 MIL-C-83733 MIL-C-26482

    Ms3473

    Abstract: MIL-C-26482 PIN CONTACT ARRANGEMENT MIL-C-24682 MS3160
    Text: MIL-C-24682 230-020H 230-020 Hermetic Receptacle, Solder Mount, Crimp Contacts HERMETIC RECEPTACLE,SOLDER MIL-C-26482 Series MOUNT, SOLDERLESS CONTACTS MIL-C-26482 SRS 2, MS3473 TYPE II, MS3473 Type HOW TO ORDER: EXAMPLE: 230 - 020H 10 - 6 D X BASIC SERIES


    Original
    PDF MIL-C-26482 MS3473 MIL-STD-1669 230-020H MIL-C-24682 500VDC MIL-C-26482 PIN CONTACT ARRANGEMENT MIL-C-24682 MS3160

    RPI234

    Abstract: MS3116 INSTRUCTIONS MS3212 030-9036-021 MS3213 DMC CRIMP TOOL CHART 600H005-13P MS3181 MS3114 MS3181-12NA
    Text: KPT/KPSE MIL-C-26482 Series 1 Applications Military and Industrial environments requiring a miniature, high density, environmental connector. • • • • • Features KPT/KPSE MIL-C-26482 Series 1 - VG 95 328 KPT & KPSE MIL-C-26482 Series I connectors offer


    Original
    PDF MIL-C-26482 RPI234 MS3116 INSTRUCTIONS MS3212 030-9036-021 MS3213 DMC CRIMP TOOL CHART 600H005-13P MS3181 MS3114 MS3181-12NA

    ms3474

    Abstract: 1561T
    Text: MIL-C-26482 Series II MIL-DTL-83723 Series I MIL-C-26482 Series II / MIL-DTL-83723 Series I filter connectors are designed to meet or exceed all applicable requirements of the military specifications. The filter connectors are intermateable and interchangeable with the standard non-filtered connectors.


    Original
    PDF MIL-C-26482 MIL-DTL-83723 ms3474 1561T

    ms3474

    Abstract: 1561T
    Text: MIL-C-26482 Series II MIL-DTL-83723 Series I MIL-C-26482 Series II / MIL-DTL-83723 Series I filter connectors are designed to meet or exceed all applicable requirements of the military specifications. The filter connectors are intermateable and interchangeable with the standard non-filtered connectors.


    Original
    PDF MIL-C-26482 MIL-DTL-83723 ms3474 1561T

    MS3479

    Abstract: MIL-C-26482 PIN CONTACT ARRANGEMENT
    Text: MIL-C-24682 230-022 230-022H Hermetic Receptacle, Jam-Nut Mount, Crimp Contacts HERMETIC RECEPTACLE, JAM-NUT MIL-C-26482 Series II, MS3479 Type MOUNT, SOLDERLESS CONTACTS, MIL-C-26482 SRS 2, MS3479 TYPE HOW TO ORDER: EXAMPLE: 230 - 022H 10 - 6 D X MASTER POLARIZING


    Original
    PDF MIL-C-26482 MS3479 MIL-STD-1669 230-022H MIL-C-24682 MIL-C-39029/15-* MS3160-* MIL-C-26482 PIN CONTACT ARRANGEMENT

    Untitled

    Abstract: No abstract text available
    Text: Standard Finishes Standard Finishes CONNECTOR SPECIFICATION MIL-C-5015 MIL-C-5015 MIL-C-26482 MIL-C-26482 MIL-C-28840 MIL-C-38999 MIL-C-38999 MIL-C-38999 MIL-C-83723 MIL-C-83723 MIL-C-83723 40M38277 40M 38298 40M 39569 LN 29504 LN 29729 PAN 6432-1 PAN 6433-1


    OCR Scan
    PDF MIL-C-5015 MIL-C-26482 MIL-C-28840 MIL-C-38999 MIL-C-83723

    f19k

    Abstract: MS27506 MIL-C-5015 mil-c-38999 iv MIL-C-5015G MS3416-G MS3417
    Text: INHALTSVERZEICHNIS Table Of C ontents 3 Übersicht c Summary MIL-C-38999 VG 96912 MIL-C-5015G MIL-C-26482/ II MIL-C-83723/ l+lll Seite Page X X X X X 2-5 X X X X X 6-9 I + II III + IV F19K X F42 X G8266 16 X Typenbezeichnung alt/neu Part Number Old/New MIL-C-38999


    OCR Scan
    PDF MIL-C-38999 G8266 MIL-C-5015G MIL-C-26482/ MIL-C-83723/ MS3416-. MS3417-. MS3418-. MS27506. f19k MS27506 MIL-C-5015 mil-c-38999 iv MIL-C-5015G MS3416-G MS3417

    MS3443H

    Abstract: Burndy P/MIL-C-26482 M39029/5-20-20
    Text: MILC-Z6482 SERIES 2 SOURIAU Description an FCI Company The 8526 Series is qualified to MIL-C-26482 Series 2 and designed to meet the performance criteria of MIL-C-83723 Series I. In 1975, the Department of Defense inactivated MIL-C-83723 Series I in favor of MIL-C-26482


    OCR Scan
    PDF MILC-Z6482 MIL-C-26482 MIL-C-83723 MIL-C-39029/4 MIL-T-22520. M81969/14-02 M81969/14-03 M81969/14-04 MS3443H Burndy P/MIL-C-26482 M39029/5-20-20