Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    MEASUREMENT RF GSM Search Results

    MEASUREMENT RF GSM Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    LBAA0QB1SJ-295 Murata Manufacturing Co Ltd SX1262 MODULE WITH OPEN MCU Visit Murata Manufacturing Co Ltd
    GRM-KIT-OVER100-DE-D Murata Manufacturing Co Ltd 0805-1210 over100uF Cap Kit Visit Murata Manufacturing Co Ltd
    LBUA5QJ2AB-828 Murata Manufacturing Co Ltd QORVO UWB MODULE Visit Murata Manufacturing Co Ltd
    LXMSJZNCMH-225 Murata Manufacturing Co Ltd Ultra small RAIN RFID chip tag Visit Murata Manufacturing Co Ltd
    LXMS21NCMH-230 Murata Manufacturing Co Ltd Ultra small RAIN RFID chip tag Visit Murata Manufacturing Co Ltd

    MEASUREMENT RF GSM Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    A 3020

    Abstract: GSM software defined radio GMSK gsm 4 bit rf module
    Text: PXI Modules GSM/EDGE Measurement Suite A complete suite of measurement functions to analyze GSM and EDGE mobile transceiver RF performance in conjunction with Aeroflex 3000 Series PXI RF modules. • TX average power and burst power profile • GMSK phase error peak and RMS


    Original
    PDF

    HP346A

    Abstract: HP346B low noise transistors rf MAX2640 MAX2645 MAX2684 MAX2700 MAX9982 N8973A MAX2649
    Text: Maxim > App Notes > BASESTATIONS / WIRELESS INFRASTRUCTURE WIRELESS, RF, AND CABLE Nov 21, 2003 Keywords: rf, rfic, wireless, noisefigure measurement, gain, meter, y factor, rf ics, rfics APPLICATION NOTE 2875 Three Methods of Noise Figure Measurement Abstract: Three different methods to measure noise figure are presented: Gain method, Y-factor method, and


    Original
    MAX2643: MAX2645: MAX2648: MAX2649: MAX2654: MAX2655: MAX2656: MAX2684: MAX2700: MAX9982: HP346A HP346B low noise transistors rf MAX2640 MAX2645 MAX2684 MAX2700 MAX9982 N8973A MAX2649 PDF

    181d . RDL, Inc., "Instruction Manual for IMD-181D Intermodulation Distortion Simulator"

    Abstract: rohde LDMOS NONLINEAR Analog Devices Power Meter class A push pull power amplifier multi port circulator two Tone generator 8vsb modulator
    Text: test & measurement Two-tone IMD measurement techniques Seven rules to ensure the best characterization of non-linear RF components By Keith Barkley T wo-tone testing for intermodulation distortion IMD has a long and venerable history. Since the dawn of RF engineering, it has been used to


    Original
    PDF

    rf power detector circuit diagram

    Abstract: NCS5000
    Text: NCS5000 Integrated RF Schottky Detector The NCS5000 is an integrated schottky detector intended for use as a level detector in RF measurement/power control applications such as those found in GSM handsets. The detector converts the peak RF voltage applied to a DC level. The circuit consists of an RF schottky


    Original
    NCS5000 rf power detector circuit diagram PDF

    NCP500

    Abstract: NCS5000 NCS5000SNT1 rf power detector circuit diagram rf detector diode low power
    Text: NCS5000 Integrated RF Schottky Detector The NCS5000 is an integrated schottky detector intended for use as a level detector in RF measurement/power control applications such as those found in GSM handsets. The detector converts the peak RF voltage applied to a DC level. The circuit consists of an RF schottky


    Original
    NCS5000 NCS5000 r14525 NCS5000/D NCP500 NCS5000SNT1 rf power detector circuit diagram rf detector diode low power PDF

    Untitled

    Abstract: No abstract text available
    Text: SAW Filters TMX U403 SAW BandPASS Filter - GSM850 - Rx RF Tentative Specification Rev-1 Technical overview .P01 Matching Network Configuration .P01 Nominal Response (Measurement) .P02


    Original
    GSM850 GSM850 924cifications PDF

    Untitled

    Abstract: No abstract text available
    Text: PXI GSM/EDGE Measurement Suite The GSM/EDGE measurement suite is a collection of software tools for use with Aeroflex PXI 3000 Series RF modular instruments for characterising the performance of GSM/HSCSD/GPRS and EGPRS mobile devices in accordance with the methods described in 3GPP 51-010-1.


    Original
    PDF

    ad8307

    Abstract: AD8313-EVAL HP8112A AD8313 AD8313ARM AD8313ARM-REEL AD8313ARM-REEL7 P6205
    Text: APPLICATIONS RF Transmitter Power Amplifier Setpoint Control and Level Monitoring Logarithmic Amplifier for RSSI Measurement Cellular Base Stations, Radio Link, Radar PRODUCT DESCRIPTION The AD8313 is a complete multistage demodulating logarithmic amplifier, capable of accurately converting an RF signal at


    Original
    AD8313 RM-08) ad8307 AD8313-EVAL HP8112A AD8313ARM AD8313ARM-REEL AD8313ARM-REEL7 P6205 PDF

    HP8112A

    Abstract: AD8313 AD8313ARM-REEL AD8313ARM-REEL7 AD8313-EVAL P6205 RM-082 .015 duroid
    Text: APPLICATIONS RF Transmitter Power Amplifier Setpoint Control and Level Monitoring Logarithmic Amplifier for RSSI Measurement Cellular Base Stations, Radio Link, Radar PRODUCT DESCRIPTION The AD8313 is a complete multistage demodulating logarithmic amplifier, capable of accurately converting an RF signal at


    Original
    AD8313 RM-08) HP8112A AD8313ARM-REEL AD8313ARM-REEL7 AD8313-EVAL P6205 RM-082 .015 duroid PDF

    Untitled

    Abstract: No abstract text available
    Text: LMV232 www.ti.com SNWS017B – DECEMBER 2004 – REVISED APRIL 2005 LMV232 Dual-Channel Integrated Mean Square Power Detector for CDMA & WCDMA Check for Samples: LMV232 FEATURES DESCRIPTION • • • • The LMV232 dual RF detector is designed for RF transmit power measurement in mobile phones. This


    Original
    LMV232 SNWS017B LMV232 PDF

    HP346B

    Abstract: HP346A MAX2105 MAX2640 MAX2645 MAX2684 MAX2700 MAX9982 N8973A
    Text: BASESTATIONS / WIRELESS INFRASTRUCTURE WIRELESS, RF, AND CABLE Nov 21, 2003 Three Methods of Noise Figure Measurement Three different methods to measure noise figure are presented: Gain method, Y-factor method, and the Noise Figure Meter method. The three


    Original
    log10 MAX2641: MAX2642: MAX2643: MAX2645: MAX2648: MAX2649: MAX2654: MAX2655: MAX2656: HP346B HP346A MAX2105 MAX2640 MAX2645 MAX2684 MAX2700 MAX9982 N8973A PDF

    bosch 0 281 002 784

    Abstract: No abstract text available
    Text: Data sheet Rev 2.3 22.11.2013 Low cost Spectrum Analyzer SPECTRAN HF-2025E RF measurement device for the novice at an unbeatable price "Unbeatable price." "Particularly Aaronia's very powerful especially considering their price SPECTRAN handheld spectrum analysers caused much excitement."


    Original
    HF-2025E HF-4040 HF-2025E DE-54597 bosch 0 281 002 784 PDF

    LMH2110

    Abstract: PEAK DETECTOR CIRCUIT SHORT NOTE LTE filter band 13 A115 C101 JESD22 Detector "Peak-to-Average Ratio
    Text: LMH2110 8 GHz Logarithmic RMS Power Detector with 45 dB dynamic range General Description Features The LMH2110 is a 45 dB Logarithmic RMS power detector particularly suited for accurate power measurement of modulated RF signals that exhibit large peak-to-average ratios,


    Original
    LMH2110 LMH2110 PEAK DETECTOR CIRCUIT SHORT NOTE LTE filter band 13 A115 C101 JESD22 Detector "Peak-to-Average Ratio PDF

    LMH2110

    Abstract: LTE RF Multiband A115 C101 JESD22 log amp
    Text: LMH2110 8 GHz Logarithmic RMS Power Detector with 45 dB dynamic range General Description Features The LMH2110 is a 45 dB Logarithmic RMS power detector particularly suited for accurate power measurement of modulated RF signals that exhibit large peak-to-average ratios,


    Original
    LMH2110 LMH2110 LTE RF Multiband A115 C101 JESD22 log amp PDF

    LMH2120

    Abstract: LMH2120UMX A115 C101 JESD22 LDO regulators smd marking code lmh2120um Detector "Peak-to-Average Ratio
    Text: LMH2120 6 GHz Linear RMS Power Detector with 40 dB Dynamic Range General Description Features The LMH2120 is a 40 dB Linear RMS power detector particularly suited for accurate power measurement of modulated RF signals that exhibit large peak-to-average ratios, i.e, large


    Original
    LMH2120 LMH2120 LMH2120UMX A115 C101 JESD22 LDO regulators smd marking code lmh2120um Detector "Peak-to-Average Ratio PDF

    EDB8064B1PB-8D-F

    Abstract: TPS2141PWP
    Text: 5 Rev 4 Date 3 2 1 Notes A 8/29/2011 Created from 750-2170-001 rev. D schematic input power and antenna matching component changes . Added resistor on VBAT to allow overall current measurement. B 10/6/2011 Changed antenna matching components per final RF testing.


    Original
    OMAP4460 Jack/RS-232 CLK32K GND13 GND12 GND11 GND10 EDB8064B1PB-8D-F TPS2141PWP PDF

    "LOG AMP"

    Abstract: "Logarithmic Amplifier" ad8307 note RMS-to-DC Converter AD8307 AD8361 GSM down converter log amp
    Text: Measurement and Control of RF Power Part III By Eamon Nash Applications Engineer, Analog Devices, Inc. Response of Log amp to Different Signal Types Log amps are generally specified for a sine wave input. Like diode detectors, log amps are not true rms responding. Differing signal waveforms in a log amp shift the effective


    Original
    AD8307 AD8361 pp13-14. "LOG AMP" "Logarithmic Amplifier" ad8307 note RMS-to-DC Converter AD8361 GSM down converter log amp PDF

    TDS5150

    Abstract: AD8312ACBZ-P2 AD811 AD8312 AD8313 AD8361 HP8116A
    Text: 50 MHz to 3.5 GHz, 45 dB RF Detector AD8312 FEATURES Its high sensitivity allows measurement at low power levels, thus reducing the amount of power that needs to be coupled to the detector. It is essentially a voltage-responding device, with a typical signal range of 1.25 mV to 224 mV rms or −45 dBm to


    Original
    AD8312 AD8312ACBZ-P7 AD8312ACBZ-P2 AD8312-EVALZ D05260 TDS5150 AD8312ACBZ-P2 AD811 AD8312 AD8313 AD8361 HP8116A PDF

    Untitled

    Abstract: No abstract text available
    Text: User's Guide RF EMF Strength Meter Model 480836 Safety Information CAUTION • Before making a measurement, check if the low battery symbol + is shown on the display when the meter is switched on. Replace the battery if the symbol is displayed.  In the case of prolonged storage, it is preferable to remove the battery from the meter.


    Original
    480836-en-EU PDF

    E5515B

    Abstract: E5520A E5515C e5515 PRBS-15 E1987A pesq MCS6 intel MCS-4 E5515C uncertainty
    Text: Agilent E1968A GSM/GPRS/EGPRS Test Application Technical Overview For the E5515C Wireless Communications Test Set and the E1987A Fast Switching Test Application Produce high volume quality phones at the lowest possible cost Flexible • The E1968A includes all essential


    Original
    E1968A E5515C E1987A E1968A 5990-5708EN E5515B E5520A e5515 PRBS-15 pesq MCS6 intel MCS-4 E5515C uncertainty PDF

    gsm mobile signal booster

    Abstract: W1314A 900 gsm booster W1314A E08 booster gsm antenna gsm Booster umts booster LTE Receiver gsm edge Booster UMTS gsm
    Text: Agilent W1314A Multi-band Wireless Measurement Receiver Data Sheet Fastest multi-technology receiver worldwide • Perform simultaneous multi-technology measurements during a single drive-test or indoor survey. • Supports LTE, UMTS, GSM, Mobile WiMAX , 1xEVDO, cdma2000, iDEN, CW and


    Original
    W1314A cdma2000, E6474A 5989-5722EN 5989-5735EN 5990-3449EN gsm mobile signal booster 900 gsm booster W1314A E08 booster gsm antenna gsm Booster umts booster LTE Receiver gsm edge Booster UMTS gsm PDF

    LTE transmit spectrum mask

    Abstract: DPSK DSSS lte RF Transceiver LTE transmit spectrum WiMAX baseband FDD alignment bpsk modulation and demodulation using labview QPSK DSSS qpsk transmitter wimax spectrum mask
    Text: PXI Studio Application software for advanced RF digital communications test Vector Signal Generator and Vector Signal Analyzer /Spectrum Analyzer application software with options for wireless data and cellular standards: • GSM/EDGE • UMTS/HSUPA • LTE FDD


    Original
    CDMA2000 LTE transmit spectrum mask DPSK DSSS lte RF Transceiver LTE transmit spectrum WiMAX baseband FDD alignment bpsk modulation and demodulation using labview QPSK DSSS qpsk transmitter wimax spectrum mask PDF

    GSM 1800 receiver

    Abstract: mobile jamming measurement rf gsm rf distance measurement
    Text: 4208 Off-Air Mobile Tester Highlights • High sensitivity and high output level for off-air tests • Possibility of using external amplifier thanks to separate receive and transmit connectors • Support for operation over the air • Small GSM tester with low power consumption


    Original
    PDF

    X 4202S

    Abstract: 4202s china mobile main board SERVICE MANUAL USIM measurement rf gsm CHINA MOBILE Frequency Measurement gsm module datasheet sim 900 gsm module
    Text: 4202S Mobile Service Tester Highlights The Result Upload Option allows test results to be transferred to virtually any location in the corporate network with a push of a button. • Triple-band testing/GSM 850 optional • High sensitivity in service (async) mode: –40 dBm


    Original
    4202S X 4202S 4202s china mobile main board SERVICE MANUAL USIM measurement rf gsm CHINA MOBILE Frequency Measurement gsm module datasheet sim 900 gsm module PDF