Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    MAGNETIC CONTACTORS Search Results

    MAGNETIC CONTACTORS Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    MRMS591P Murata Manufacturing Co Ltd Magnetic Sensor Visit Murata Manufacturing Co Ltd
    MRMS581P Murata Manufacturing Co Ltd Magnetic Sensor Visit Murata Manufacturing Co Ltd
    MRUS74SD-001 Murata Manufacturing Co Ltd Magnetic Sensor Visit Murata Manufacturing Co Ltd
    MRMS791B Murata Manufacturing Co Ltd Magnetic Sensor Visit Murata Manufacturing Co Ltd
    MRUS74SK-001 Murata Manufacturing Co Ltd Magnetic Sensor Visit Murata Manufacturing Co Ltd

    MAGNETIC CONTACTORS Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    LC1-D09

    Abstract: dimension LC1-D09 LC1-D25 LC1-D09 installation manual LC1-D25 wiring LC1-D2500 LP1-D09 380V 415v motor LC1 D25008 LP1-D25
    Text: Motor Control Device 1-1 Magnetic latching contactors GCR1-F series magnetic latching contactors Magnetic latching contactors of both block and bar mounted types are fitted with a special electromagnet which enables them to remain in the "On" position when the coil is no longer energised.


    Original
    GLE1-D09 GLE1-D018 GLE1-D25 GLE1-D32 GLE1-D40 GLE1-D95 LC1-D09 dimension LC1-D09 LC1-D25 LC1-D09 installation manual LC1-D25 wiring LC1-D2500 LP1-D09 380V 415v motor LC1 D25008 LP1-D25 PDF

    Magnetic

    Abstract: bernstein magnetic MAK12 630.2111.047
    Text: Table of contents Magnetic switches – General features Electromechanical magnetic switches - Selection aid cylindrical and metric housing - Selection aid rectangular housing Page 195 Page 196 Page 198 Page 201 Electronical magnetic switches - Selection aid cylindrical and rectangular housings


    Original
    IP67/NEMA BWN-M06NI/40 BWN-M06NI/27 BWN-M36NI MA-06, MA-16, MA-26, MA-15 Magnetic bernstein magnetic MAK12 630.2111.047 PDF

    GE CR2940

    Abstract: CR2940 CR2820B CR2940U202 CR2940U203 CR2810 GE CR224 Cr2943 CR2810A14 CR2940U210
    Text: Control Renewal Parts Section 12: Control Renewal Parts CONTROL RENEWAL PARTS For NEMA Rated 300- and 200-Line Magnetic Contactors and Starters, Sizes 00-7 .12-2 For Full-Voltage NEMA Rated Magnetic Contactors,


    Original
    200-Line CR2943/2940 GO-11G QCX000153 QCX000154 QCX000155 12-point GE CR2940 CR2940 CR2820B CR2940U202 CR2940U203 CR2810 GE CR224 Cr2943 CR2810A14 CR2940U210 PDF

    GE CR2940

    Abstract: CR2940 cr2820b CR2943 CR324 CR2940U202 CR2940U203 ge cr2943 CR7006 GE CR224
    Text: Control Renewal Parts Section 14 Renewal Parts For NEMA Rated 300- and 200-Line Magnetic Contactors and Starters, Sizes For Full-Voltage NEMA Rated Magnetic Contactors, Starters and Relays, Sizes


    Original
    200-Line CR2943/2940 GO-11G QCX000143 QCX000144 QCX000165 12-point GE CR2940 CR2940 cr2820b CR2943 CR324 CR2940U202 CR2940U203 ge cr2943 CR7006 GE CR224 PDF

    MC3-3-75-240

    Abstract: magnetic contactors
    Text: Magnetic Contactors From $ 33 Special Purpose Contactors for High Power Temperature Control MADE IN USA Control Resistance Heaters up to 75 Amps Using OMEGA Temperature Controllers and Magnetic Contactors ߜ Long LifeOver 500,000 Operations ߜ 30 to 75 Amps


    Original
    MC2-3-50-240, MC3-3-75-240, MC3-3-75-240 magnetic contactors PDF

    westinghouse breaker

    Abstract: westinghouse contactor westinghouse autotransformer starter westinghouse circuit breakers WESTINGHOUSE westinghouse size 5 contactor westinghouse motor starter westinghouse circuit breaker autotransformer starter motor starter autotransformer
    Text: BULLETIN m wwc PRODUCT DATA 513 WESTINGHOUSE CIRCUIT BREAKER RATINGS Inverse-Time Thermal Magnetic Type Used in Circuit Breaker Type Combination Starters Description All combination contactors and autotransformer starters with circuit breakers include the Westinghouse inverse-time (thermal magnetic) type


    Original
    PDF

    moeller dil 1m

    Abstract: DILEM-01-G HP C9017-80055-A 54 Moeller DIL EM 10 DILEM-10-G-C magnetic Contactor 24VDC DIL contactors DILEEM-10-G magnetic contactors DILEM-10-G
    Text: Moeller Electric Corporation UL / CSA / IEC / CE DIL Contactors Basic Devices, Modules Magnetic Contactors, Magnetic Starters Rating data UL/CSA max. Horsepower rating 50/60 Hz 1 phase 115 V 200 V HP UL / CSA / IEC / CE DIL Contactors Basic Devices, Modules


    Original
    40DILE-C 22DDILE-C moeller dil 1m DILEM-01-G HP C9017-80055-A 54 Moeller DIL EM 10 DILEM-10-G-C magnetic Contactor 24VDC DIL contactors DILEEM-10-G magnetic contactors DILEM-10-G PDF

    TM 1628

    Abstract: TM 1628 Datasheet magnetic Contactor trip coil 3PST
    Text: HARTMAN Aerospace Power Products BP-493-1 3PST, Magnetic Latch, 385 Amps, 115/200 VAC, 400 Hz Plug-In ContactorsTM Features: • 3PST Main Contacts • Transient Suppression • Magnetic Latch • Self De-Energizing Coil • Designed for ease of maintenance


    Original
    BP-493-1 MIL-R-6106 TM 1628 TM 1628 Datasheet magnetic Contactor trip coil 3PST PDF

    magnetic Contactor

    Abstract: magnetic contactors BP-493-1
    Text: Plug-In ContactorsTM BP-493-1 3PST, Magnetic Latch, 385 Amps, 115/200 VAC, 400 Hz Features: • 3PST Main Contacts • Transient Suppression • Magnetic Latch • Self De-Energizing Coil • Designed for ease of maintenance • Less than 10µ contact chatter during high


    Original
    BP-493-1 MIL-R-6106 magnetic Contactor magnetic contactors PDF

    Magnetic

    Abstract: bernstein magnetic
    Text: Electromechanical magnetic switches Bernstein magnetic switches – the advantages ● reliability even under extreme ambient conditions. They are unaffected by dirt, humidity, gases, dust, etc. and operate completely free from wear and tear ● IP 67 protection


    Original
    MA-04 MA-06 MA-08 MA-11 MA-12 MA-13 MA-16 MA-17 MA-18 MA-23 Magnetic bernstein magnetic PDF

    CD14

    Abstract: CB-21 DB10 DB21 air circuit-breakers GB2-CD07 GB2-CD06 D40-D80 D25-D32 marking D09
    Text: Presentation, selection Protection components Thermal-magnetic circuit-breakers model GB2 for the protection of industrial equipment control circuits Presentation GB2 thermal-magnetic circuit-breakers protect and isolate the control circuits of industrial equipment with contactor coils, transformers.…


    Original
    21092-EN CD14 CB-21 DB10 DB21 air circuit-breakers GB2-CD07 GB2-CD06 D40-D80 D25-D32 marking D09 PDF

    60947-2 MAX EARTH LOOP IMPEDANCE

    Abstract: NS160N ns100n GV2-L20 GV2-ME14 GV2-L14 gv2-l16 GV2-L08 LR2-D1308 GV2-L07
    Text: 3/02-03 Page 3 Monday, October 29, 2001 10:37 AM Presentation TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7 GV2-ME, GV2-P, GV3-ME and GV7-R motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers specifically


    Original
    PDF

    MS4SM-AP

    Abstract: 58a9 TP814 fuji relay
    Text: 03 Individual catalog No. LOW VOLTAGE PRODUCTS Up to 600 Volts 01 Magnetic Contactors and Starters Thermal Overload Relays, Solid-state Contactors 02 Manual Motor Starters and Contactors Combination Starters 03 Industrial Relays, Industrial Control Relays


    Original
    DEC2003 MS4SM-AP 58a9 TP814 fuji relay PDF

    MC2127

    Abstract: MC1910U marking Ed12 MC184 MCC21273 MCC21272 marking Ed11 MC21271 ED12 MC-284-J1
    Text: MC and MCC Series 4C NEMA 3, 4 Watertight Pushbutton Stations, Selector Switches and Pilot Lights 600 VAC Heavy Duty Options: MC pushbuttons or selector switches are used: • In conjunction with magnetic starters or contactors for remote control of motors


    Original
    MC180 MC-280-J1 MCC180 MCC280 MC184 MC-284-J1 MCC184 MCC284 MC182 MC282 MC2127 MC1910U marking Ed12 MCC21273 MCC21272 marking Ed11 MC21271 ED12 MC-284-J1 PDF

    HP 450 motor

    Abstract: d79 motor 3PST 40VA magnetic contactors RLY456 10VA RLY400 RLY455 600VAC
    Text: RLY400 Series Features • • • Straight Through Wiring Heavy Duty Universal Mounting Plate Definite Purpose, 3PST−DM, 25 Amp, Magnetic Contactors D79 3.750 95.3 3.250 (82.55) .500 (12.7) Dia 1.500 (38.1) 2.050 (52.1) 2.500 (63.5) 2.150 (54.61) .210 (5.33) x .450 (11.43)


    Original
    RLY400 600VAC RLY455 RLY456 277VAC 720VA, 120-600VAC 277VAC) 120VAC HP 450 motor d79 motor 3PST 40VA magnetic contactors RLY456 10VA RLY455 600VAC PDF

    Untitled

    Abstract: No abstract text available
    Text: SPARK QUENCHERS EXAMPLES OF ABSORPTION OF NOISE The following illustrations show examples of the operation of a variety of commonly used magnetic relays and contactors with and without a Spark Quencher. The ability of the Spark Quencher to integrate peak power surges and suppress high


    Original
    XE-1202 XE-120033 PDF

    SC-05 Fuji

    Abstract: SC03Y square d starter type sc03 Fuji 3pole 3 phase magnetic Contactor SC-N* "Fuji" SCN5 KK05-042 SC-03RM TR-N3 SC03 Index 1
    Text: Magnetic Contactors and Starters General information 01 FUJI low-voltage contactors and starters are available in a broad choice of types, from high-performance to economy, for all consumer and industrial needs. For standard applications, we offer the highperformance SC series. We offer the


    Original
    SC-03 WN11J SZ-WN10RJ SZ-WN11RJ SW-N10RM/3H SW-N11RM/3H, N12RM/3H SC-05 Fuji SC03Y square d starter type sc03 Fuji 3pole 3 phase magnetic Contactor SC-N* "Fuji" SCN5 KK05-042 SC-03RM TR-N3 SC03 Index 1 PDF

    SALZER S225 35 AMP 600 VAC ROTARY CAM SWITCH

    Abstract: salzer s220 salzer RELAY c316fna3 CE15FNS3 salzer T220 salzer T225 Salzer S225 CE15DNS3 CE15ENS3
    Text: ELECTRICAL COMPONENTS Magnetic Starters • Cutler-Hammer quality • Highest HP rating in a compact space saving design • Long-life twin break, silver cadmium oxide contacts provide superior resistance to welding and arc erosion • Din rail mounting Part No.


    Original
    PDF

    Allen-Bradley heater elements

    Abstract: TFK 925 TED136020WL TED136015WL TED136025WL MOTOR PROTECTION circuit breaker 60 -80 AMPS circuit breaker 225A TED136030WL TED136040CL TFK 110
    Text: PRODUCT DATA CIRCUIT BREAKERS RATINGS OF GENERAL ELECTRIC CIRCUIT BREAKERS Thermal-Magnetic Inverse Time Type Used in Circuit Breaker Type Combination Starters the table (on reverse side). Select the trip setting at approximately 10 times the motor nameplate full-load current.


    OCR Scan
    TJK436250LL 25104-356-06O TJK436400LL 25105-356-09O TKMA836600LL TKMA836800LL TKMA30800LL TKMA31200LL Allen-Bradley heater elements TFK 925 TED136020WL TED136015WL TED136025WL MOTOR PROTECTION circuit breaker 60 -80 AMPS circuit breaker 225A TED136030WL TED136040CL TFK 110 PDF

    S-N25 Magnetic Contactor

    Abstract: S-N11 Magnetic Contactor SN95 mitsubishi mitsubishi contactor s-n35 s-n50 mitsubishi contactor mitsubishi contactor s-n65 SD-N35CX contactor s-n35 Mitsubishi th-n20kp UN-SA25
    Text: MITSUBISHI ELECTRIC Low Voltage Switchgear Magnetic Contactors Thermal Overload Relays Contactor Relays h (h) 2 2 1 1 (s) 1000 800 600 400 (s) 1000 800 600 400 200 200 Operating Time Operating Time A2 A1 100 80 60 40 30 20 10 8 6 4 21 1/L1 3/L2 5/L3 43 31


    Original
    D-40880 RUS-109240 S-N25 Magnetic Contactor S-N11 Magnetic Contactor SN95 mitsubishi mitsubishi contactor s-n35 s-n50 mitsubishi contactor mitsubishi contactor s-n65 SD-N35CX contactor s-n35 Mitsubishi th-n20kp UN-SA25 PDF

    LCI-D09

    Abstract: CONTACTOR LCi-D09 GB2-DB20 GB2-CB05 gb2-cd14 GB2-DB14 GB2-CD05 GB2-CB09 GB2-CB22 GB2-DB12
    Text: Circuit breakers Characteristics : pages 3/91 to 3/93 References : pages 3/94 and 3/95 Dimensions : page 3/95 Schemes : page 3/95 Thermal-magnetic circuit breakers type GB2 for the protection of industrial equipment control circuits Presentation, selection


    Original
    GB2-G210 GB2-G01 GB2-G02 LCI-D09 CONTACTOR LCi-D09 GB2-DB20 GB2-CB05 gb2-cd14 GB2-DB14 GB2-CD05 GB2-CB09 GB2-CB22 GB2-DB12 PDF

    vde 0660-209 en 1088 en 954-1 ip 67

    Abstract: VDE-0660-209 VDE 0660-209 D40B-2 D40B-2D3 D40B d40b1 D40B-J1 vde 0660-209 en 1088 D40B-1B10
    Text: Compact Non-contact Door Switch D40B Series CSM_D40B_DS_E_3_1 Detects the open/closed state of doors without making contact and has high resistance to the environment. • Detects the open/closed state of doors without making contact by combining a special magnetic Actuator and


    Original
    PDF

    cp clare reed relay

    Abstract: ECG transistor replacement guide book free sip 1A05 12V 40W Fluorescent Lamp Driver circuit Diagram CP Clare Prme 15002 cp clare u prma 2a05 REED RELAY 15005 LSR2C05 CLARE REED RELAY PRMA 1a24 clare prme 15005
    Text: SECTIONS CP Clare Company Overview 1 Product Selection Guide 2 Advanced Magnetic Products 3 Circuit Products 4 Reed Relay Products 5 Switch and Sensor Products 6 Surge Protection Products 7 Glossary 8 Index by Part Number 9 www.cpclare.com iii TABLE OF CONTENTS


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Safety Modules Safety Gate and Safety Magnetic Sensor Types NSC02D, NSC13D • Safety Category 4, Performance Level e, according to EN 13849-1 • Safety Category 4 according to EN 954-1 • Category 0 Emergency Stop EN 60204-1 • Input type: 1 NO + 1 NC


    Original
    NSC02D, NSC13D NSC02D) NSC13D) NSC02D NSC13D PDF