Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    LPJ_SP 600 Search Results

    LPJ_SP 600 Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    Untitled

    Abstract: No abstract text available
    Text: Low Voltage, Branch Circuit Rated Fuses Low-Peak dual-element, time-delay fuses 600A 400A 125A 200A 250A 60A 80A 100A 30A 15A 6A 10A 3A 1A Now Available AMPERE RATING 300 With Optional Low Voltage Branch Circuit Fuses Time-Current Characteristic Curves–Average Melt


    Original
    600Vac 300Vdc PDF

    E56412

    Abstract: LPJ25SPI LPJ50SPI LPJ-15SP LPJ-40SP LPJ-6SP LPJ-9SP LPJ-10SPI lpj_sp LPJ-15SPI
    Text: Bussmann LOW-PEAK LPJ_SPI ® Dual-Element Time-Delay Fuses Class J – 600 Volt Dimensional Data 2.25" ± 0.03 .81" .5" (± 0.03) 1A to 30A 2.38" (± 0.03) .63" 35A to 60A 1.06" (± 0.03) Catalog Symbol: LPJ_SPI Dual-Element, Time-Delay – 10 seconds (minimum) at 500%


    Original
    600Vac 300Vdc 5-60A E56412 SB04295 E56412 LPJ25SPI LPJ50SPI LPJ-15SP LPJ-40SP LPJ-6SP LPJ-9SP LPJ-10SPI lpj_sp LPJ-15SPI PDF

    iec 947-4-1

    Abstract: LPJ-200SPI LPJ-125SPI LPJ 2 400 LPJ400SPI LPJ300SPI LPJ-150SPI LPJ-175SPI LPJ-200SP LPJ-70SP
    Text: Bussmann LOW-PEAK® LPJ_SPI Dual-Element, Time-Delay Fuses Class J – 600 Volt 70 to 600A Dimensional Data 4.63" – 0.03 3.63" 2.63" .75" 1.13" (– 0.03) 1" .28" .43" 70A to 100A .13" 5.75" (– 0.03) 4.38" 3.0" 110A to 200A .43" Catalog Symbol: LPJ-_SPI


    Original
    E56412 SB04295 iec 947-4-1 LPJ-200SPI LPJ-125SPI LPJ 2 400 LPJ400SPI LPJ300SPI LPJ-150SPI LPJ-175SPI LPJ-200SP LPJ-70SP PDF

    Transformer Protection

    Abstract: 400kVA C3746 400kva transformer 800va ups circuit bussmann Fuse 170M series 4503 transformer JCW-1E fuse 170m 800va ups
    Text: Equipment Protection Transformers — 600V or Less The requirements of 450.3 cover only transformer protection. In practice, other components must be considered in applying circuit overcurrent protection. For circuits with transformers, requirements for conductor protection per Articles


    Original
    5500V 7500V 4000V 6000V 8000V Transformer Protection 400kVA C3746 400kva transformer 800va ups circuit bussmann Fuse 170M series 4503 transformer JCW-1E fuse 170m 800va ups PDF

    LPJ-100SP

    Abstract: LPJ450SP LPJ600SP LPJ-400SP LPJ110SP LPJ-600SP LPJ-80SP LPJ-90SP LPJ350SP LPJ-70SP
    Text: Bussmann LOW-PEAK® LPJ Dual-Element, Time-Delay Fuses Class J – 600 Volt 70 to 600A Dimensional Data 4.63" – 0.03 3.63" 2.63" .75" 1.13" (– 0.03) 1" .28" .43" 70A to 100A .13" 5.75" (– 0.03) 4.38" 3.0" 110A to 200A .43" 1.13" .28" 1.63" (– 0.03)


    Original
    600Vac E56412 300Vdc A03094 LPJ-100SP LPJ450SP LPJ600SP LPJ-400SP LPJ110SP LPJ-600SP LPJ-80SP LPJ-90SP LPJ350SP LPJ-70SP PDF

    LPJ-60SP

    Abstract: LPJ-30-SP LPJ-20SP LPJ-30SP 15sp LPJ6-SP lpjsp LPJ-10SP LPJ50SP LPJ-25SP
    Text: Bussmann LOW-PEAK LPJ ® Dual-Element Time-Delay Fuses Class J – 600 Volt Dimensional Data 2.25" ± 0.03 .81" .5" (± 0.03) 1A to 30A 2.38" (± 0.03) .63" 35A to 60A 1.06" (± 0.03) Catalog Symbol: LPJ-_SP Dual-Element, Time-Delay – 10 seconds (minimum) at 500%


    Original
    600Vac 300Vdc E56412 SB02295 LPJ-60SP LPJ-30-SP LPJ-20SP LPJ-30SP 15sp LPJ6-SP lpjsp LPJ-10SP LPJ50SP LPJ-25SP PDF

    3PRA 20

    Abstract: 3PRA 60 5a 3PRA 60 3PRA 20 3a 3pra 15sp LPJ-10SP JP60030-3PRA LPJ-30SP LPJ-60SP
    Text: Bussmann LOW-PEAK LPJ ® Dual-Element Time-Delay Fuses Class J – 600 Volt Dimensional Data 2.25" ± 0.03 .81" .5" (± 0.03) 1A to 30A 2.38" (± 0.03) .63" 35A to 60A 1.06" (± 0.03) Catalog Symbol: LPJ-_SP Dual-Element, Time-Delay – 10 seconds (minimum) at 500%


    Original
    E56412 A99016 3PRA 20 3PRA 60 5a 3PRA 60 3PRA 20 3a 3pra 15sp LPJ-10SP JP60030-3PRA LPJ-30SP LPJ-60SP PDF

    date sheet for sa 2 of 10 class

    Abstract: lpjsp FNQ-R-8/10 JCG-30 JCH-30 LP-CC-12 FUSES LPCC-12 bussmann class J fuses lpj_sp
    Text: Bussmann Fuses in Hazardous Locations Class I Division 1 Fuses located in Class 1 Division 1 locations are required to be provided with enclosures that are identified as sa complete assembly for use in Class 1 locations [501.115 A ]. Class I Division 2 NEC Section 501.115(B)(3) addresses the use of current-limiting fuses in Class I Division 2


    Original
    JCH-30 JCG-30 SB05094 date sheet for sa 2 of 10 class lpjsp FNQ-R-8/10 JCG-30 JCH-30 LP-CC-12 FUSES LPCC-12 bussmann class J fuses lpj_sp PDF

    Control Circuit Protection

    Abstract: fuse fnw 20 remote control circuit 2604A 72511
    Text: Motor Control Circuit Protection The Maximum Motor Circuit Feeder Fuse 430.62 1. For the one motor in the group with the highest starting current — Find the largest fuse permitted for branch circuit protection using Table 430.52 or 440.22(A). The fuse capacity permitted for the motor with the heaviest starting current may be


    Original
    0-30A 5-30A 1500AIR amp-35 amp-100 amp-200 Control Circuit Protection fuse fnw 20 remote control circuit 2604A 72511 PDF

    JTN60030

    Abstract: bussmann class J fuses JTN60060 JT60030 JT60060 buss 600VAC
    Text: Bussmann Safety J Fuseholders Class J Finger-Safe Fuseholders JT60030 JTN60030 (w/Indication) JT60060 JTN60060 (w/Indication) For use with Bussmann Class “J” fuses - (Bussmann LPJ, JKS) Catalog Numbers: JT60030 and JT60060 - Non-Indicating; JTN60030 and JTN60060 - Indicating (Neon)


    Original
    JT60030 JTN60030 JT60060 JTN60060 JT60030 JT60060 JTN60030 JTN60060 600Vac 600Vdc bussmann class J fuses buss PDF

    Untitled

    Abstract: No abstract text available
    Text: Bussmann Safety J Fuseholders Class J Touch Safe Fuseholders JT60030 JTN60030 (w/Indication) JT60060 JTN60060 (w/Indication) For use with Bussmann Class “J” fuses - (Bussmann LPJ, JKS) Catalog Numbers: JT60030 and JT60060 Non-Indicating; JTN60030 and JTN60060 - Indicating (Neon)


    Original
    JT60030 JTN60030 JT60060 JTN60060 JT60030 JT60060 JTN60030 JTN60060 N60060 PDF

    fusetron class k9

    Abstract: No abstract text available
    Text: Pg206 to 230 /12-25-01 1/3/02 3:42 PM Page 206 Fuse Technology Circuit Protection Electrical distribution systems are often quite complicated. They cannot be absolutely fail-safe. Circuits are subject to destructive overcurrents. Harsh environments, general deterioration, accidental damage, damage from natural causes, excessive expansion, and/or overloading of the electrical distribution system are


    Original
    Pg206 fusetron class k9 PDF

    KTK-R

    Abstract: LPCC-10 LPJ-100SP LPJ-8SP LP-CC-6 fuse 15sp LPJ-40-SP LPCC-15 LPCC FNQR.5
    Text: 1258-2012.qxp:QuarkCatalogTempNew 8/31/12 8:38 AM Page 1258 POWER ENCLOSURES INTERCONNECT TEST & MEASUREMENT 14 Class CC and Class J Fuses Class CC Time Delay and Fast Acting Fuses Fast Acting Fuses — KTK-R Series Continued The Cooper Bussmann “Class CC” Fuses are designed to meet the needs of control circuit transformer protection.


    Original
    KTK-R-10 KTK-R-15 KTK-R-20 KTK-R-25 KTK-R-30 JKS-10 JKS-15 JKS-20 JKS-25 JKS-30 KTK-R LPCC-10 LPJ-100SP LPJ-8SP LP-CC-6 fuse 15sp LPJ-40-SP LPCC-15 LPCC FNQR.5 PDF

    Transformer 200VA

    Abstract: 10-10A 200VA 150va transformer NFPA-79 31017 RELAY Fuses KTK-R
    Text: Motor Control Circuit Protection The Maximum Motor Circuit Feeder Fuse 430.62 1. For the one motor in the group with the highest starting current — Find the largest fuse permitted for branch circuit protection using Table 430.52 or 440.22(A). The fuse capacity permitted for the motor with the heaviest starting current may be


    Original
    PDF

    T32 fuse l 250v

    Abstract: LPCC-20 LPJ600SP NOS 600 amp fuses LPSRK1712SP LPJ-20SP CDF30J3 EFJ30X-3PB6 fuse base IEC 269 KRPC2000SP
    Text: Low Voltage, Branch Circuit Rated Fuses Page 12-14 15-16 Class Fuses Volts CC . . . . . . LP-CC . . . . . . . . . . . . . . . 600V . . . . . 17 FNQ-R . . . . . . . . . . . . . . . KTK-R . . . . . . . . . . . . . . . 600V . . . . . 600V . . . . . 18 19 600V . . . . .


    Original
    SA-3-2/10* SA-10* SA-15* SA-20* SA-30* SA-1-6/10 SA-3-2/10 SA-10 SA-15 SA-20 T32 fuse l 250v LPCC-20 LPJ600SP NOS 600 amp fuses LPSRK1712SP LPJ-20SP CDF30J3 EFJ30X-3PB6 fuse base IEC 269 KRPC2000SP PDF

    Class J Fuses

    Abstract: fusetron t E4273 3.15A 250V fuse FUSE T 3.15A 250V special purpose Fuses cooper lpj_sp 800 bussmann fuse fnq-r
    Text: Fuseology Cooper Bussmann Branch Circuit, Power Distribution Fuses Low-Peak Fuses* Now Offer Indication That's As Clear As Black And White Good Low-Peak current-limiting fuses offer optional permanent replacement fuse indication. The indicator is either


    Original
    600Vac) 250Vac) 125Vdc, 000AIR) 5-600A 250Vdc, 300Vdc, E56412, Class J Fuses fusetron t E4273 3.15A 250V fuse FUSE T 3.15A 250V special purpose Fuses cooper lpj_sp 800 bussmann fuse fnq-r PDF

    kcc cl-150

    Abstract: 3PRA 20 3PRA 60 5a 20SP 012 KRPC-3000 buss fusetron fusetron dual element FUSE FNM-6 IR 200 A mcm 750 100a 15sp 012 J60400-1CR
    Text: General Data — Selection Chart Bussmann Buss Fuse Selection Chart 600 Volts or Less Circuit Load Ampere Fuse Rating Type Symbol Voltage Rating (a-c) Class Interrupting Rating (KA) Remarks All-purpose fuses. Unequaled for combined short-circuit and overload protection.


    Original
    01-6000A) kcc cl-150 3PRA 20 3PRA 60 5a 20SP 012 KRPC-3000 buss fusetron fusetron dual element FUSE FNM-6 IR 200 A mcm 750 100a 15sp 012 J60400-1CR PDF

    bussmann Fuse 170L series

    Abstract: HTC Korea evf 8202 FM09A Cooper Bussmann kbt 300 buss fusetron mdl mdx Fuses BC603 MDM 4 COOPER BUSSMANN buss F03B
    Text: Cooper Bussmann Services & Application Guide Downtime Reduction, Workplace Safety & Code Compliance Services to Increase Your Productivity Through Protection Section Contents Cooper Bussmann Services Engineering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .370


    Original
    DK-2740 bussmann Fuse 170L series HTC Korea evf 8202 FM09A Cooper Bussmann kbt 300 buss fusetron mdl mdx Fuses BC603 MDM 4 COOPER BUSSMANN buss F03B PDF

    220v AC voltage stabilizer schematic diagram

    Abstract: 11kV breaker control circuit diagram 110 KW motor 11kv 170H1007 price list for bussmann semiconductor fuse 10SP 010 fusetron dual element fnm-5 3PRA 20 HRC fuse gg GEC 10SP 005
    Text: Bussmann Circuit Protection Solutions Bussmann ® Worldwide Circuit Protection Solutions World’s leading supplier of fuses and fusible protection systems, Bussmann continues its 88-year history of blazing new trails of innovative technologies. Maker of the industry’s first


    Original
    88-year 10-02-50M 30-Amp 60-Amp IP-20) 30Amp 60-Amp 10-02-40M 220v AC voltage stabilizer schematic diagram 11kV breaker control circuit diagram 110 KW motor 11kv 170H1007 price list for bussmann semiconductor fuse 10SP 010 fusetron dual element fnm-5 3PRA 20 HRC fuse gg GEC 10SP 005 PDF

    3PRA 20

    Abstract: BUSSMANN KTK-15 JJS-45 KTU-80 3PRA 60 FRS-R-40 20SP 012 LPJ-20SP FRN-R-10 LPJ-400SP
    Text: Niederspannungs-Sicherungseinsätze für industrielle Anwendungen Allgemeine Angaben - Maße Zoll Klasse J Klasse T Klasse RK5 und RK1 ® Low-Peak und Limitron Sicherungen LPJ und JKS (600V) T-Tron Sicherungen JJN (300V) JJS (600V) Fusetron®-, Low-Peak®- und


    Original
    FNQ-15 FNQ-20 FNQ-25 FNQ-30 3PRA 20 BUSSMANN KTK-15 JJS-45 KTU-80 3PRA 60 FRS-R-40 20SP 012 LPJ-20SP FRN-R-10 LPJ-400SP PDF

    GB13539

    Abstract: CHM3DU
    Text: Fuse Holders and Blocks Section Contents Page RED indicates NEW information 273 Fuse Holders & Blocks CH Series Global Modular fuse holders and accessories . . . . . . . . . . . . . . . . . . . . . 274-280 Remote Fuse Monitoring - CH-PLCCH . . . . . . . . . . . . 278


    Original
    OPM-1038 WH-90Vdc-600Vdc, 115Vac-600Vac MT12-1-2 LPF1-24 LPF1-120 LPF1-120-C LPF1-220 LPF1-440 GB13539 CHM3DU PDF

    170M8554

    Abstract: bussmann Fuse 450 amps 250 volts max zs FM09 PS Jet 20A 300v fuse
    Text: Circuit Protection Products for the Electrical Industry New Products for All Markets For product data sheets, visit www.cooper.bussmann.com/products/datasheet.asp Circuit Protection Products for the Electrical Industry Table of Contents RED indicates NEW information


    Original
    0210-55M 170M8554 bussmann Fuse 450 amps 250 volts max zs FM09 PS Jet 20A 300v fuse PDF

    220v AC voltage stabilizer schematic diagram

    Abstract: FUSE M2 250e 11kV breaker control circuit diagram bussmann Fuse 170L series bussmann semiconductor fuse catalogue arc welder schematic HRC fuse gg GEC relay applications for 6.6kV switchgear ups circuits 170E bussmann
    Text: Circuit Protection Products for the Electrical Industry New Products for All Markets For product data sheets, visit www.cooper.bussmann.com/products/datasheet.asp Circuit Protection Products for the Electrical Industry Table of Contents RED indicates NEW information


    Original
    0210-55M 220v AC voltage stabilizer schematic diagram FUSE M2 250e 11kV breaker control circuit diagram bussmann Fuse 170L series bussmann semiconductor fuse catalogue arc welder schematic HRC fuse gg GEC relay applications for 6.6kV switchgear ups circuits 170E bussmann PDF

    ana 658 solar charge

    Abstract: RD2004 for 4120 40A 14VDC relay pico fuse color code varistor 20sp Lucent SLC 96 cabinet MDM cooper bussmann semiconductor fuse catalogue MDQ 100a 600v bridge rectifier GBA 616
    Text: Bussmann electrical full line catalog Leadership in Circuit Protection Introducing Bussmann by Eaton The protection you rely on. For more, visit Bussmann.com Leadership in Circuit Protection. The only company that can provide a complete circuit protection solution for all applications.


    Original