Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    LC1 F185 Search Results

    SF Impression Pixel

    LC1 F185 Price and Stock

    Schneider Electric LC1F185BDS121

    CONTACTOR CONTACTOR PEM
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey LC1F185BDS121 Box 1
    • 1 $1603.04
    • 10 $1603.04
    • 100 $1603.04
    • 1000 $1603.04
    • 10000 $1603.04
    Buy Now

    Schneider Electric LC1F185

    Contactor, 3Pst-No, Panel; Load Current Inductive:185A; Relay Mounting:Panel; Operating Voltage:1Kv; Contact Configuration:3Pst-No; No. Of Poles:3 Pole; Switching Power Ac3:110Kw; Switching Current Ac1:275A; Coil Voltage Vac Nom:-; Rohs Compliant: Yes |Schneider Electric LC1F185
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Newark LC1F185 Bulk 1
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Buy Now

    Schneider Electric LC1F185G6

    Contactor 600Vac 185Amp Iec +Options Rohs Compliant: Yes |Schneider Electric LC1F185G6
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Newark LC1F185G6 Bulk 1
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Buy Now

    Schneider Electric LC1F185BD

    Contactor 600Vac 185Amp Iec +Options |Schneider Electric LC1F185BD
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Newark LC1F185BD Bulk 1
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Buy Now

    Schneider Electric LC1F185G7

    Contactor 600Vac 185Amp Iec +Options |Schneider Electric LC1F185G7
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Newark LC1F185G7 Bulk 1
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Buy Now

    LC1 F185 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    LC1 D38

    Abstract: lc1 f265 LC1 F400 LC1-k16 LP1 K12 contactor LC1-D25 Lc1 f630 LP1 K09 LC1-D09 LC1-D18
    Text: Selection 5 TeSys contactors 5 For utilisation category AC-3 Operational current and power conforming to IEC θ y 60 °C 1 Contactor size Maximum operational current in AC-3 Rated operational power P (standard motor power ratings) 2 3 y 440 V A LC1/ LP1


    Original
    PDF

    dr5te4u

    Abstract: DR5TE4U contactor coil rectifier LC1-F115 LC1-D40 LX1D6M5 LC1 F150 LC1-D115 LC1 F115 LC1 Schneider lx1d6f7
    Text: Repair Parts D- and F-Line AC Coils www.SquareD.com FOR CURRENT INFORMATION For LC1 D40, D50, D65, D80 Rated voltage nominal voltage V 24 32 42 48 110 120 127 208 220 230 240 256 277 380 400 415 440 480 500 575 600 660 Specification Average consumption - inrush inductance .75


    Original
    PDF 8502CT9901R2/01 dr5te4u DR5TE4U contactor coil rectifier LC1-F115 LC1-D40 LX1D6M5 LC1 F150 LC1-D115 LC1 F115 LC1 Schneider lx1d6f7

    telemecanique LC1 f400

    Abstract: NS630H NS400H NS250H c1001 merlin gerin NS80H Telemecanique LC1 EC 19 lc1 f265 telemecanique magnetic contactor NS160H
    Text: Selection guide TeSys Model U Starter-controllers Control units Function characteristics Control units Standard LUCA Thermal overload protection Overcurrent protection Advanced LUCB LUCC LUCD 14.2 x the setting current Short-circuit protection Protection against phase loss


    Original
    PDF AC-15 DC-13 telemecanique LC1 f400 NS630H NS400H NS250H c1001 merlin gerin NS80H Telemecanique LC1 EC 19 lc1 f265 telemecanique magnetic contactor NS160H

    LC1-D50A

    Abstract: LC1D40A schneider LC1-D09 LC1-DWK12 LC1D65A LC1-D09 LAD4TBDL LC1-D18 LC1-D09 installation manual LC1-D12
    Text: Motor control 1 TeSys range provide you more simplicity, compactness, openness and flexibility . so many evolutions and new items to aid your productivity. 2 Accurate and reliable control of motors 3 4 5 6 7 Increase your productivity, adopt our solutions which help to simplify


    Original
    PDF LC1-F630, F6304 LC1-F500 F5004 LC1-F400 F4004 LC1-D50A LC1D40A schneider LC1-D09 LC1-DWK12 LC1D65A LC1-D09 LAD4TBDL LC1-D18 LC1-D09 installation manual LC1-D12

    f630

    Abstract: LA4DWB LC1 F150 lc1f LA4-Dwb 48 VDC interposing relay LC1D09 CONTACTOR lc1d09 LA4DT0U LA4-DR2U
    Text: Accessories Electronic Timers and Interface Modules www.SquareD.com FOR CURRENT INFORMATION The following accessories mount to the line-side of the contactors and connect at terminals A1 and A2. Electronic Serial Timer Modules These solid state modules delay the energizing and de-energizing of the contactor coil.


    Original
    PDF LC1D40 LC1D09 LP1D09 F6304, 8502CT9901R2/01 f630 LA4DWB LC1 F150 lc1f LA4-Dwb 48 VDC interposing relay LC1D09 CONTACTOR LA4DT0U LA4-DR2U

    F5367

    Abstract: LR9-F5369 LR9F5371 LR9F5369 LR9-F5371 LR9F5357 F5369 LR9F5567 LR9F5569 LR9F7375
    Text: Protection components References 3-pole electronic thermal overload relays, model LR9 F for motor protection Compensated and differential overload relays Thermal overload relays: b compensated and differential, b with relay trip indicator, b for a.c., b for direct mounting on contactor or independent mounting 1 .


    Original
    PDF F5357 F5363 F5367 F5369 27074-EN F5367 LR9-F5369 LR9F5371 LR9F5369 LR9-F5371 LR9F5357 F5369 LR9F5567 LR9F5569 LR9F7375

    catalogue

    Abstract: jigo products SCR 131- 6 WJ 59 SCR 131- 6 WJ 69 SCR 131- 6 WJ 68 SCR 131- 6 WJ 60 LC1-D32 SCR 131- 6 WJ 67 SCR 131- 6 WJ 65 ST3PA
    Text: JiGO PRODUCTS CATALOGUE it all began in 1987…. The founder hit upon the electrical business in 1987 in the financial hub of eastern India, Kolkata. In midst of severe competition and tough markets, their values and committment towards quality and customer service set them apart from


    Original
    PDF JG-GV3-M06 JG-GV3-M07 JG-GV3-M08 JG-GV3-M10 JG-GV3-M14 JG-GV3-M20 JG-GV3-M25 JG-GV3-M40 JG-GV3-M63 JG-GV3-M80 catalogue jigo products SCR 131- 6 WJ 59 SCR 131- 6 WJ 69 SCR 131- 6 WJ 68 SCR 131- 6 WJ 60 LC1-D32 SCR 131- 6 WJ 67 SCR 131- 6 WJ 65 ST3PA

    telemecanique contactor catalogue

    Abstract: LA9-D09980 LC1-F630 LC1-F225 telemecanique lc1 fh 43 LC1F150 LC1-F330 LC1-F400 lc1f LC1F500
    Text: Contactors F 3-pole contactors for motor control, 115 to 780 A Utilisation category AC-3 Control circuit : a.c. or d.c. c or a References 3-pole contactors 1 Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 Rated operational current in AC-3


    Original
    PDF LC1-F115 LC1-F150 LC1-F185 LC1-F225 LC1-F265 LC1-F330 LA9-F103 LR9-F5i57, F5i63, F5i67, telemecanique contactor catalogue LA9-D09980 LC1-F630 LC1-F225 telemecanique lc1 fh 43 LC1F150 LC1-F330 LC1-F400 lc1f LC1F500

    schneider LC1-D09 wiring diagram

    Abstract: LC1-D38 LC1-D18 LT6P0M005FM LC2K06 LC1-D09 installation manual LC1K0910BD 8502CT9901 LC1K0910P7 LC1-D12
    Text: Motor control Accurate and reliable control of motors Te Sys range provide you more simplicity, compactness, openness and flexibility . so man y evolutions and new items to aid your productivity. Search By Part Number TeSys For a new start! A range of simple,


    Original
    PDF 9422CLA50 9422CLA51 9422CLA10 9422CLA11 9422CSF30 9422CSF50 9422CSF70 9422CSF10 9422CSF304 9422CSF504 schneider LC1-D09 wiring diagram LC1-D38 LC1-D18 LT6P0M005FM LC2K06 LC1-D09 installation manual LC1K0910BD 8502CT9901 LC1K0910P7 LC1-D12

    RE8RB31BU

    Abstract: LC1D40A RE8TA41BU A9F74 b40 B2 RECTIFIER 400V LC1DT60A LC1-D50A LC1D40008 XUX0ARCTT16T LR2K
    Text: global specialist in energy management The architects of efficiency Singapore Mongolia Price List Catalogue 2013 Electrical Distribution, Automation & Control  ! % 3% %3      3'33,  3 3% %3 (  +3&-=33&2/=


    Original
    PDF 197903476G) MN-EC1113 SG-PL0413 RE8RB31BU LC1D40A RE8TA41BU A9F74 b40 B2 RECTIFIER 400V LC1DT60A LC1-D50A LC1D40008 XUX0ARCTT16T LR2K

    Schneider NS 800

    Abstract: LUA1C110 LB920 LUCA 1XBL schneider thermal overload relay schneider GV2 LA9LB920 Schneider Electric lub LUB320 schneider motor starter
    Text: TeSys Model U Selection guide Starter-controllers Function performed Function not performed Selectable overload class Detection of overtorque, no-load running, long starting times Earth fault protection equipment protection only Protection against phase imbalance


    Original
    PDF AP00r AP11r AP12r Schneider NS 800 LUA1C110 LB920 LUCA 1XBL schneider thermal overload relay schneider GV2 LA9LB920 Schneider Electric lub LUB320 schneider motor starter

    LA9LB920

    Abstract: GV3-ME40 GV2-RT08 GK3EF40 schneider GV2ME GV-AE113 GK3EF65 schneider LRD-14 GV2-L32 LC1k schneider
    Text: Presentation TeSys protection components Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7 GV2-ME, GV2-P, GV3-ME and GV7-R motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers specifically designed for the control and protection of motors, conforming to standards IEC 947-2 and IEC 947-4-1.


    Original
    PDF GV7-V01 LA9LB920 GV3-ME40 GV2-RT08 GK3EF40 schneider GV2ME GV-AE113 GK3EF65 schneider LRD-14 GV2-L32 LC1k schneider