Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    LC1 CONTACTOR COIL POWER Search Results

    LC1 CONTACTOR COIL POWER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TPD4164F Toshiba Electronic Devices & Storage Corporation Intelligent power device / VBB=600V / Iout=2A/ Surface mount type / HSSOP31 Visit Toshiba Electronic Devices & Storage Corporation
    TPD4164K Toshiba Electronic Devices & Storage Corporation Intelligent power device / VBB=600V / Iout=2A/ Through hole type / HDIP30 Visit Toshiba Electronic Devices & Storage Corporation
    TPD4163K Toshiba Electronic Devices & Storage Corporation Intelligent power device / VBB=600V / Iout=1A/ Through hole type / HDIP30 Visit Toshiba Electronic Devices & Storage Corporation
    TPD4163F Toshiba Electronic Devices & Storage Corporation Intelligent power device / VBB=600V / Iout=1A/ Surface mount type / HSSOP31 Visit Toshiba Electronic Devices & Storage Corporation
    TPD4207F Toshiba Electronic Devices & Storage Corporation Intelligent power device 600V (High voltage PWM DC brushless motor driver) Visit Toshiba Electronic Devices & Storage Corporation

    LC1 CONTACTOR COIL POWER Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    LC1-F225

    Abstract: LC1-F330 LC1-D95 LC1-F630 LC1-F185 LC1 Schneider LC1-D50 lC1F265 LC1-F265 LP1-D25
    Text: Sélection Contactors Contactors for the North American market conforming to standards UL and CSA, 20 to 120 A Standard power ratings Taille of motors 50/60 Hz Size Single-phase 3-phase 1Ø 3Ø 115 V 230 V 200 V 230 V 460 V 575 V 240 V 208 V 240 V 480 V 600 V


    Original
    AWG10 LP1-D09 LP1-D12 LP1-D18 LP1-D25 LC1-F185. LC1-F265 LC1-F630 LC1-F185 LC1-F225 LC1-F330 LC1-D95 LC1 Schneider LC1-D50 lC1F265 LP1-D25 PDF

    lc1d12008

    Abstract: LC1D40008 lc1-d25008 LC1D12004 LC1-D1810 lp1d1210 telemecanique LC1-d18 LC2D0901 LA1-DN22 telemecanique contactor LC1D80
    Text: Contactors d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. Dimensions, mounting : pages 1/44 to 1/48 References Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 θ ≤ 55 °C 1 Rated operational


    Original
    LC1-D0900ii LC1-D0910ii LC1-D0901ii LC1-D1200ii LC1-D1210ii LC1-D1201ii LC1-D1800ii LC1-D1810ii LC1-D1801ii LC1-D2500ii lc1d12008 LC1D40008 lc1-d25008 LC1D12004 LC1-D1810 lp1d1210 telemecanique LC1-d18 LC2D0901 LA1-DN22 telemecanique contactor LC1D80 PDF

    CONTACTOR LP4 K

    Abstract: LC1 contactor LP1 contactor LC7 CONTACTOR LC1 contactor COIL POWER k0601 LP4 contactor LC-7 K1210 24407
    Text: References 5 TeSys contactors 5 Contactors for motor control, 6 to 16 A in category AC-3 and 6 to 12 A in category AC-4 Control circuit: a.c. 106151_1 Contactor selection according to utilisation category, see pages 24565/2 to 24565/5 and 24566/2 to 24566/5.


    Original
    K0910pp 24402-EN CONTACTOR LP4 K LC1 contactor LP1 contactor LC7 CONTACTOR LC1 contactor COIL POWER k0601 LP4 contactor LC-7 K1210 24407 PDF

    LC1k09008

    Abstract: LC1K0910 lc7k09 LC1K09 LC1K LA1KN lc2K zener diode 1N PH 48 LP1K09008 LP1-K0910
    Text: Characteristics Contactors Contactors and reversing contactors types LCp-K and LPp-K Environment Conforming to standards Approvals LCp and LPp-K06 to K12 Operating positions Vertical axis Horizontal axis Without derating Without derating UL, CSA, DEMKO, NEMKO, SEMKO, FI


    Original
    LPp-K06 LA1-KN20 LA1-KN02 LA1-KN207 LA1-KN027 13/NO LC1k09008 LC1K0910 lc7k09 LC1K09 LC1K LA1KN lc2K zener diode 1N PH 48 LP1K09008 LP1-K0910 PDF

    LP1K09

    Abstract: LP1K06 LC1K0910 LP4K09 LC1K09 lc7k09 LC1K0610 LP4-K0610 LP1K09 Contactor lc2K
    Text: Mini contactors K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. c References a.c. control contactors 1 - Mounting on 35 mm " rail or Ø 4 mm screw fixing. - Screws in open “ready-to-tighten” position.


    Original
    LC1-K0610ii LA9-K0970 DX1-AP25 LA9-E01 LA9-D973 DX1-AP25. LA9-D973 LP1K09 LP1K06 LC1K0910 LP4K09 LC1K09 lc7k09 LC1K0610 LP4-K0610 LP1K09 Contactor lc2K PDF

    LC1-D123

    Abstract: LC1-D093 LC1-D323 LC1-D183 LA6-DK20 LC1-D253 LAD6K10 LC1-D150 LAD-4RC LA6DK10
    Text: Characteristics TeSys contactors 5 Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32 & DT40 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage Ui 2 Rated impulse withstand voltage (Uimp) Conforming to IEC EN 947-4-1,


    Original
    LC1LC1LC1D09. LC1D50. LC1-D115 LC1-D150 LC1-D09. LC1-D80 LC1-D40. LC1-D123 LC1-D093 LC1-D323 LC1-D183 LA6-DK20 LC1-D253 LAD6K10 LC1-D150 LAD-4RC LA6DK10 PDF

    schneider LC1-D38

    Abstract: LC1-D38 LC1-D09 LC1-D123 lc1d128 LC1-D093 LC1D09 schneider LC1-DT25 schneider LC1-D258 schneider LC1-D09
    Text: References TeSys contactors For motor control up to 75 kW at 400 V, in category AC-3 Control circuit: a.c., d.c. or low consumption 810356 3-pole contactors for connection by screw clamp terminals or connectors Standard power ratings of 3-phase motors 50/60 Hz in category AC-3


    Original
    LC1-D09// LC1-D12// LC1-D18// LC1-D25// LC2-DT20. schneider LC1-D38 LC1-D38 LC1-D09 LC1-D123 lc1d128 LC1-D093 LC1D09 schneider LC1-DT25 schneider LC1-D258 schneider LC1-D09 PDF

    telemecanique contactor catalogue

    Abstract: LA9-D09980 LC1-F630 LC1-F225 telemecanique lc1 fh 43 LC1F150 LC1-F330 LC1-F400 lc1f LC1F500
    Text: Contactors F 3-pole contactors for motor control, 115 to 780 A Utilisation category AC-3 Control circuit : a.c. or d.c. c or a References 3-pole contactors 1 Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 Rated operational current in AC-3


    Original
    LC1-F115 LC1-F150 LC1-F185 LC1-F225 LC1-F265 LC1-F330 LA9-F103 LR9-F5i57, F5i63, F5i67, telemecanique contactor catalogue LA9-D09980 LC1-F630 LC1-F225 telemecanique lc1 fh 43 LC1F150 LC1-F330 LC1-F400 lc1f LC1F500 PDF

    LC1-DT40

    Abstract: LC1D80004 LADN10 Schneider LC1DT20 LC1-D65 LADS2 LC1-D38 WIRING LC1-D09 lad-s2 LC1-D80004
    Text: References TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters For 3-pole motor reversing contactors using 2 identical contactors 810373 Contactors with screw clamp terminals or connectors


    Original
    LC1-D09. LA9-D6569 LA9-D4002 LA9-D8069 LA9-D8002 LA9-D92 LA9-D93 LC1-DT40 LC1D80004 LADN10 Schneider LC1DT20 LC1-D65 LADS2 LC1-D38 WIRING LC1-D09 lad-s2 LC1-D80004 PDF

    telemecanique LC1 f400

    Abstract: NS630H NS400H NS250H c1001 merlin gerin NS80H Telemecanique LC1 EC 19 lc1 f265 telemecanique magnetic contactor NS160H
    Text: Selection guide TeSys Model U Starter-controllers Control units Function characteristics Control units Standard LUCA Thermal overload protection Overcurrent protection Advanced LUCB LUCC LUCD 14.2 x the setting current Short-circuit protection Protection against phase loss


    Original
    AC-15 DC-13 telemecanique LC1 f400 NS630H NS400H NS250H c1001 merlin gerin NS80H Telemecanique LC1 EC 19 lc1 f265 telemecanique magnetic contactor NS160H PDF

    telemecanique contactor catalogue

    Abstract: LC1 D12 wiring diagram LC1 K12 Schneider telemecanique contactor lc1 d65 Telemecanique LC1 D12 Telemecanique LC1 D38 LC1 D18 wiring diagram LC1 D09 10 wiring diagram ATS01N232QN Schneider contactor catalogue
    Text: Soft starters ATS 01 Catalogue May 07 General contents Soft starters for asynchronous motors 1 – Altistart 01 2 – Altistart U01 1 Contents 1 - Altistart 01 soft starters for asynchronous motors b Presentation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 1/2 and 1/3


    Original
    05/2007-V2 DIA2ED2040201EN telemecanique contactor catalogue LC1 D12 wiring diagram LC1 K12 Schneider telemecanique contactor lc1 d65 Telemecanique LC1 D12 Telemecanique LC1 D38 LC1 D18 wiring diagram LC1 D09 10 wiring diagram ATS01N232QN Schneider contactor catalogue PDF

    LC1 D32 wiring diagram

    Abstract: schneider overload relay lrd 25 LC1 contactor LA7 D09 54 overload schneider thermal overload relay lrd 32 LC1 d32 contactor diagram schneider electric LC1 D25 LA7 D09 LRD 14 LC1 d150 wiring diagram
    Text: Issued November 2009 DATA SHEET LR-D OVERLOAD RELAYS Based on Schneider MKTED205103EN Catalogue 12493 General 6 12493 Protection components 6 Motor protection Operating conditions There are many possible causes of electric motor failure. One of the most common,


    Original
    MKTED205103EN LC1 D32 wiring diagram schneider overload relay lrd 25 LC1 contactor LA7 D09 54 overload schneider thermal overload relay lrd 32 LC1 d32 contactor diagram schneider electric LC1 D25 LA7 D09 LRD 14 LC1 d150 wiring diagram PDF

    telemecanique contactor catalogue

    Abstract: telemecanique VDE 0660 telemecanique DOL motor starter telemecanique LC1 IEC 292-1 telemecanique lc1 contactor catalogue telemecanique thermal overload relay Telemecanique MOTOR STARTER table telemecanique contactor catalogue LC1 contactor telemecanique LC1
    Text: Issued November 1991 012-570 Data Pack B Data Sheet Direct on line DOL starters Telemecanique ‘d2’ range A range of 4 and 9kW direct on line ac starters using the new Telemecanique ‘d2’ motor control gear range and conforming to IEC 947-4, IEC 292-1, BS4941 and


    Original
    BS4941 2xPE16 telemecanique contactor catalogue telemecanique VDE 0660 telemecanique DOL motor starter telemecanique LC1 IEC 292-1 telemecanique lc1 contactor catalogue telemecanique thermal overload relay Telemecanique MOTOR STARTER table telemecanique contactor catalogue LC1 contactor telemecanique LC1 PDF

    telemecanique contactor catalogue

    Abstract: telemecanique LC1 telemecanique thermal overload relay telemecanique VDE 0660 telemecanique lc1 contactor catalogue contactor telemecanique LC1 telemecanique contactor LC1 Telemecanique MOTOR STARTER telemecanique DOL motor starter LP1 CONTACTOR TELEMECANIQUE
    Text: Issued March 1997 232-3591 Data Pack B Data Sheet Direct on line DOL starters Telemecanique ‘d2’ range A range of 4 and 9kW direct on line ac starters using the new Telemecanique ‘d2’ motor control gear range and conforming to IEC 947-4, IEC 292-1, BS4941 and


    Original
    BS4941 circula135 2xPE16 telemecanique contactor catalogue telemecanique LC1 telemecanique thermal overload relay telemecanique VDE 0660 telemecanique lc1 contactor catalogue contactor telemecanique LC1 telemecanique contactor LC1 Telemecanique MOTOR STARTER telemecanique DOL motor starter LP1 CONTACTOR TELEMECANIQUE PDF

    catalogue

    Abstract: jigo products SCR 131- 6 WJ 59 SCR 131- 6 WJ 69 SCR 131- 6 WJ 68 SCR 131- 6 WJ 60 LC1-D32 SCR 131- 6 WJ 67 SCR 131- 6 WJ 65 ST3PA
    Text: JiGO PRODUCTS CATALOGUE it all began in 1987…. The founder hit upon the electrical business in 1987 in the financial hub of eastern India, Kolkata. In midst of severe competition and tough markets, their values and committment towards quality and customer service set them apart from


    Original
    JG-GV3-M06 JG-GV3-M07 JG-GV3-M08 JG-GV3-M10 JG-GV3-M14 JG-GV3-M20 JG-GV3-M25 JG-GV3-M40 JG-GV3-M63 JG-GV3-M80 catalogue jigo products SCR 131- 6 WJ 59 SCR 131- 6 WJ 69 SCR 131- 6 WJ 68 SCR 131- 6 WJ 60 LC1-D32 SCR 131- 6 WJ 67 SCR 131- 6 WJ 65 ST3PA PDF

    schneider LC1-D09 wiring diagram

    Abstract: LC1-D38 LC1-D18 LT6P0M005FM LC2K06 LC1-D09 installation manual LC1K0910BD 8502CT9901 LC1K0910P7 LC1-D12
    Text: Motor control Accurate and reliable control of motors Te Sys range provide you more simplicity, compactness, openness and flexibility . so man y evolutions and new items to aid your productivity. Search By Part Number TeSys For a new start! A range of simple,


    Original
    9422CLA50 9422CLA51 9422CLA10 9422CLA11 9422CSF30 9422CSF50 9422CSF70 9422CSF10 9422CSF304 9422CSF504 schneider LC1-D09 wiring diagram LC1-D38 LC1-D18 LT6P0M005FM LC2K06 LC1-D09 installation manual LC1K0910BD 8502CT9901 LC1K0910P7 LC1-D12 PDF

    Schneider NS 800

    Abstract: LUA1C110 LB920 LUCA 1XBL schneider thermal overload relay schneider GV2 LA9LB920 Schneider Electric lub LUB320 schneider motor starter
    Text: TeSys Model U Selection guide Starter-controllers Function performed Function not performed Selectable overload class Detection of overtorque, no-load running, long starting times Earth fault protection equipment protection only Protection against phase imbalance


    Original
    AP00r AP11r AP12r Schneider NS 800 LUA1C110 LB920 LUCA 1XBL schneider thermal overload relay schneider GV2 LA9LB920 Schneider Electric lub LUB320 schneider motor starter PDF

    RE8RB31BU

    Abstract: LC1D40A RE8TA41BU A9F74 b40 B2 RECTIFIER 400V LC1DT60A LC1-D50A LC1D40008 XUX0ARCTT16T LR2K
    Text: global specialist in energy management The architects of efficiency Singapore Mongolia Price List Catalogue 2013 Electrical Distribution, Automation & Control  ! % 3% %3      3'33,  3 3% %3 (  +3&-=33&2/=


    Original
    197903476G) MN-EC1113 SG-PL0413 RE8RB31BU LC1D40A RE8TA41BU A9F74 b40 B2 RECTIFIER 400V LC1DT60A LC1-D50A LC1D40008 XUX0ARCTT16T LR2K PDF

    S-N25 Magnetic Contactor

    Abstract: LC1 D12 wiring diagram wiring diagram dol starter GV2 AN11 AD0101 GV2 ME20 gv2 me10 GV2 ME05 wiring 3 phase dol starter with emergency stop AP-385
    Text: 1 2 3 4 5 6 7 8 9 10 5/0 version: 1.0 S0556-EN_Ver1.0.indd Content chapter 5 Safety control and protection solutions Mini-VARIO and VARIO switch disconnectors Selection guide: Mini-VARIO and VARIO switch disconnectors . . . . . . . . . . . 5/2 1 Mini-VARIO switch disconnectors


    Original
    S0556-EN S-N25 Magnetic Contactor LC1 D12 wiring diagram wiring diagram dol starter GV2 AN11 AD0101 GV2 ME20 gv2 me10 GV2 ME05 wiring 3 phase dol starter with emergency stop AP-385 PDF

    SDS Relais rh-c-12v

    Abstract: EUD61M rac 16a 400v
    Text: 1949–2015 YEARS OF INNOVATION Switchgear, power supply units and electronic energy meters for installation in buildings and use in control technology Products and prices 2015 Switching on the future Pictograms The performance of our switchgear has become so complex that we have devised pictograms to depict


    Original
    D-70736 I-64025 CH-8954 E-08398 SDS Relais rh-c-12v EUD61M rac 16a 400v PDF

    zelio plc wiring diagram cable

    Abstract: photovoltaic cell ana 650 2.5 kva inverter diagrams ELEVATOR LOGIC CONTROL PLC APC SMART-UPS CIRCUIT DIAGRAM MDG99603 MD1AA730PE SOLAR INVERTER 1000 watts circuit diagram 100 kva UPS APC zigbee door controller
    Text: Technical education Educational solutions Catalogue 2013 - 2014 Learning a job is fine. Learning the future is better. In the future, today's businesses are going to evolve into an overall expertise that covers all types of energy. For those working in, this represents both a real


    Original
    ZZ4781 zelio plc wiring diagram cable photovoltaic cell ana 650 2.5 kva inverter diagrams ELEVATOR LOGIC CONTROL PLC APC SMART-UPS CIRCUIT DIAGRAM MDG99603 MD1AA730PE SOLAR INVERTER 1000 watts circuit diagram 100 kva UPS APC zigbee door controller PDF

    LC1-D09

    Abstract: LC1-D18 LC1 D12 10 LC1 D09 10 LC1 contactor LC1 D12 P7 LC1 D18 P7 LC1-D12 LC1 D18 LC1 D09 BL
    Text: 5 0 /6 0 HZ AC3 DUTY SINGLE PHASE CATALOG 1 15V 230V D09 0.5 HP 1 HP D12 1 HP 2 HP D18 1 HP 3 HP 200V 2 HP 3 HP 5 HP THREE 230V 2 HP 3 HP 5 HP PHASE 460V 5 HP 7.5 HP 10 HP 575V 7.5 HP 10 HP 15 HP COIL VOLTAGES FOR LC1 D09 TO D80 VOLTS 12 24 48 72 110 125 115


    OCR Scan
    D09--600V/9A, E48539/NLDX LC1-D09 LC1-D18 LC1 D12 10 LC1 D09 10 LC1 contactor LC1 D12 P7 LC1 D18 P7 LC1-D12 LC1 D18 LC1 D09 BL PDF

    telemecanique contactor catalogue

    Abstract: telemecanique LC1D115 schneider contactor catalogue LC1-D150 LC1-D115 DIMENSIONS LA9-D115603 lc1d11500 CONTACTOR LC1-D115 telemecanique catalogue contactor telemecanique LC1D
    Text: Telemecanique D contactors and overload relays D115-59kw AC3 D150-80kw AC3 Telemecaniques’ D range is the world’s number one in contactors. Two new D range contactors are now available, expanding the range to 80kw AC3 for motor control and 200A AC1 for distribution


    OCR Scan
    D115-59kw D150-80kw telemecanique contactor catalogue telemecanique LC1D115 schneider contactor catalogue LC1-D150 LC1-D115 DIMENSIONS LA9-D115603 lc1d11500 CONTACTOR LC1-D115 telemecanique catalogue contactor telemecanique LC1D PDF

    telemecanique contactors

    Abstract: Telemecanique LC1 D 128 F7 bs 5424 schneider CA2SK20 telemecanique LC1 CA2SK LC1 TELEMECANIQUE fl 34 LC1 fl 34 TELEMECANIQUE Telemecanique VO merlin gerin ic 2000 p
    Text: SK ra n g e a u n c h c a t a l o g u GROUPE SCHNEIDER Conversion table IDI S Q U A R E ^Ü Telem ecanique | D | s q u a re D . P rancie □ rSIIQG g P ranae "*• II» n i» E ^ T e le m e c a n iq u e BÜTelemecanique SK range SK range EÜTelemecanique ^ S K r a n q e


    OCR Scan
    PZV48 telemecanique contactors Telemecanique LC1 D 128 F7 bs 5424 schneider CA2SK20 telemecanique LC1 CA2SK LC1 TELEMECANIQUE fl 34 LC1 fl 34 TELEMECANIQUE Telemecanique VO merlin gerin ic 2000 p PDF