    Abstract: No abstract text available
    Text: Technical Specification IQ12-QTC Family BASIC OPERATION AND FEATURES CONTROL FEATURES The InQor series converter uses a two-stage power conversion topology. The first stage is a buck-converter that keeps the output voltage constant over variations in line, load, and


    Original
    IQ12-QTC 200ms 200ms IQ12xxxQTCxx 005-IQ12QTX PDF

    Untitled

    Abstract: No abstract text available
    Text: Technical Specification IQ12-QTC Family PART nUMBeRInG SySTeM ORDeRInG InFORMATIOn The part numbering system for SynQor’s InQor dc-dc converters follows the format shown in the example below. The tables below show the valid model numbers and ordering options for converters in this product family. When ordering


    Original
    IQ12-QTC rpartnumberconsistingofthe12characterbase IQ12018QTC40xyz IQ12033QTC30xyz IQ12050QTC20xyz IQ12070QTC14xyz IQ12120QTC08xyz IQ12150QTC07xyz IQ12240QTC04xyz IQ12300QTC03xyz PDF

    Untitled

    Abstract: No abstract text available
    Text: Input: Output: Current: Part No.: Technical Specification 9-22 V 15 V 7A IQ12150QTC07 IQ12150QTC07 ELECTRICAL CHARACTERISTICS 15 VOUT TA = 25 °C, airflow rate = 300 LFM, VIN = 12 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C


    Original
    IQ12150QTC07 IQ12150QTC07 IQ12xxxQTCxx 50V/ms) 005-IQ12QTX PDF

    IQ12240QTC04

    Abstract: thermal fuse 115 250V 2A IQ12480QTC02
    Text: Technical Specification IQ12-QTC Family 9-22 V 25 V 1.8-48 V 105 W 2250 V dc Cont. Input Trans. Input Outputs Max Power Isolation Quarter-brick DC-DC Converter The InQor quarter-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching


    Original
    IQ12-QTC IQ12xxxQTCxx 155SwansonRoad MA01719 005-IQ12QTX IQ12240QTC04 thermal fuse 115 250V 2A IQ12480QTC02 PDF

    Untitled

    Abstract: No abstract text available
    Text: Input: Output: Current: Part No.: Technical Specification 9-22 V 3.3 V 30 A IQ12033QTC30 IQ12033QTC30 ELECTRICAL CHARACTERISTICS 3.3 VOUT TA = 25 °C, airflow rate = 300 LFM, VIN = 24 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C


    Original
    IQ12033QTC30 IQ12033QTC30 500mV/div) IQ12xxxQTCxx 50V/ms) 005-IQ12QTX PDF

    Untitled

    Abstract: No abstract text available
    Text: Technical Specification IQ12-QTC Family 9-22 V 25 V 1.8-48 V 105 W 2250 V dc Cont. Input Trans. Input Outputs Max Power Isolation Quarter-brick DC-DC Converter The InQor quarter-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching


    Original
    IQ12-QTC IQ12xxxQTCxx 005-IQ12QTX PDF

    Untitled

    Abstract: No abstract text available
    Text: Input: Output: Current: Part No.: Technical Specification 9-22 V 5.0V 20 A IQ12050QTC20 IQ12050QTC20 ELECTRICAL CHARACTERISTICS 5.0 VOUT TA = 25 °C, airflow rate = 300 LFM, VIN = 12 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C


    Original
    IQ12050QTC20 IQ12050QTC20 500mV/div) IQ12xxxQTCxx 50V/ms) 005-IQ12QTX PDF

    Untitled

    Abstract: No abstract text available
    Text: Input: Output: Current: Part No.: Technical Specification 9-22 V 1.8 V 40 A IQ12018QTC40 IQ12018QTC40 ELECTRICAL CHARACTERISTICS 1.8 VOUT TA = 25 °C, airflow rate = 300 LFM, VIN = 12 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C


    Original
    IQ12018QTC40 IQ12018QTC40 200mV/div) IQ12xxxQTCxx 50V/ms) 005-IQ12QTX PDF

    Untitled

    Abstract: No abstract text available
    Text: Input: Output: Current: Part No.: Technical Specification 9-22 V 12 V 8A IQ12120QTC08 IQ12120QTC08 ELECTRICAL CHARACTERISTICS 12 VOUT TA = 25 °C, airflow rate = 300 LFM, VIN = 12 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C


    Original
    IQ12120QTC08 IQ12120QTC08 IQ12xxxQTCxx 50V/ms) 005-IQ12QTX PDF

    Untitled

    Abstract: No abstract text available
    Text: Input: Output: Current: Part No.: Technical Specification 9-22 V 30 V 3A IQ12300QTC03 IQ12300QTC03 ELECTRICAL CHARACTERISTICS 30 VOUT TA = 25 °C, airflow rate = 300 LFM, VIN = 12 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C


    Original
    IQ12300QTC03 IQ12300QTC03 IQ12xxxQTCxx 50V/ms) 005-IQ12QTX PDF

    IQ12480QTC02

    Abstract: No abstract text available
    Text: Input: Output: Current: Part No.: Technical Specification 9-22 V 48 V 2A IQ12480QTC02 IQ12480QTC02 ELECTRICAL CHARACTERISTICS 48 VOUT TA = 25 °C, airflow rate = 300 LFM, VIN = 12 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C


    Original
    IQ12480QTC02 IQ12480QTC02 IQ12xxxQTCxx 50V/ms) 005-IQ12QTX PDF

    Untitled

    Abstract: No abstract text available
    Text: Input: Output: Current: Part No.: Technical Specification 9-22 V 24 V 4A IQ12240QTC04 IQ12240QTC04 ELECTRICAL CHARACTERISTICS 24 VOUT TA = 25 °C, airflow rate = 300 LFM, VIN = 12 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C


    Original
    IQ12240QTC04 IQ12240QTC04 IQ12xxxQTCxx 50V/ms) 005-IQ12QTX PDF

    Untitled

    Abstract: No abstract text available
    Text: Input: Output: Current: Part No.: Technical Specification 9-22 V 7.0 V 14 A IQ12070QTC14 IQ12070QTC14 ELECTRICAL CHARACTERISTICS 7.0 VOUT TA = 25 °C, airflow rate = 300 LFM, VIN = 12 VDC unless otherwise noted; full operating temperature range is -40 °C to +100 °C


    Original
    IQ12070QTC14 IQ12070QTC14 200mV/div) IQ12xxxQTCxx 50V/ms) 005-IQ12QTX PDF