Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    INTERPOSING CURRENT TRANSFORMER Search Results

    INTERPOSING CURRENT TRANSFORMER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TLX9188 Toshiba Electronic Devices & Storage Corporation Photocoupler (phototransistor output), DC input, 3750 Vrms, SO6, Automotive Visit Toshiba Electronic Devices & Storage Corporation
    TPD4207F Toshiba Electronic Devices & Storage Corporation Intelligent power device 600V (High voltage PWM DC brushless motor driver) Visit Toshiba Electronic Devices & Storage Corporation
    TPD4204F Toshiba Electronic Devices & Storage Corporation Intelligent power device 600V (High voltage PWM DC brushless motor driver) Visit Toshiba Electronic Devices & Storage Corporation
    TLP294-4 Toshiba Electronic Devices & Storage Corporation Photocoupler (phototransistor output), AC input, 3750 Vrms, 4 channel, SO16 Visit Toshiba Electronic Devices & Storage Corporation
    TLP295-4 Toshiba Electronic Devices & Storage Corporation Photocoupler (phototransistor output), DC input, 3750 Vrms, 4 channel, SO16 Visit Toshiba Electronic Devices & Storage Corporation

    INTERPOSING CURRENT TRANSFORMER Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    interposing CT

    Abstract: abb rxdsb 4 Transformer differential protection RADSB RK 625 interposing relay interposing 1MRK 514 001-BEN RADSB RK 625 001 CC radsb RXMS 1mdu04007-en
    Text: Transformer differential protection RADSB 1MRK 504 002-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice SE970883 Features • Three phase differential protection with two, three, five or six through-current restraint inputs


    Original
    002-BEN SE970883) 1MDU04007-EN AG03-5005E 015-BEN 001-BEN 003-BEN interposing CT abb rxdsb 4 Transformer differential protection RADSB RK 625 interposing relay interposing 1MRK 514 001-BEN RADSB RK 625 001 CC radsb RXMS 1mdu04007-en PDF

    interposing CT

    Abstract: slce capacitor interposing relay interposing 1mdu04007-en RXSGA 016-BEN interposing CT, technical 1MRK 514 001-BEN calculation of transformer differential relay setting
    Text: Multi-purpose percentage restraint differential protection RADSC 1MRK 509 016-BEN Page 1 Issued June 2002 Changed since June 1999 Data subject to change without notice SE970169 Features • Complete phase and earth fault protection for generators, motors, reactors, cables or


    Original
    016-BEN SE970169) 1MDU09023-EN 1MDU04007-EN 002-BEN 015-BEN 001-BEN 003-BEN interposing CT slce capacitor interposing relay interposing 1mdu04007-en RXSGA 016-BEN interposing CT, technical 1MRK 514 001-BEN calculation of transformer differential relay setting PDF

    automatic phase changer file

    Abstract: 3 phase automatic phase changer automatic phase changer interposing CT ABB rxce 41 Relay manual automatic 3 phase changer SLmf tap control transformer RAYA RXCE 4 interposing relay
    Text: RAYA Voltage regulating relay for tap changer control 1MRK 504 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice SE 84 05 42 Features • Accurate regulation of tap-changers • Inverse or definite time delay • Undervoltage and overcurrent blocking


    Original
    006-BEN 010-BEN 1MDU04011-EN SE-721 automatic phase changer file 3 phase automatic phase changer automatic phase changer interposing CT ABB rxce 41 Relay manual automatic 3 phase changer SLmf tap control transformer RAYA RXCE 4 interposing relay PDF

    interposing relay

    Abstract: Allen-Bradley auxiliary contact 595-A 500F-BOD930 592-EUTB 592-EEHE 509-FOD 599-KA04 509-BOD Bulletin 709 Motor Starter Coil 599-k04
    Text: Bulletin 500 Line Open Type Modular Kits and Components Selection Guide Bulletin 500, 500F, 509 NEMA AC Contactors and Starters Product Overview NEMA AC Contactor and Starter Modular Kits and Components NEMA sizes 0…4 for open-type Bulletin 500 top-wired contractors, Bulletin 500F feed-through contactors, and Bulletin 509 fullvoltage starters, are provided as modular kits for faster delivery. Other sizes and enclosed-type devices are also available.


    Original
    800T/H 500-SG008A-EN-P interposing relay Allen-Bradley auxiliary contact 595-A 500F-BOD930 592-EUTB 592-EEHE 509-FOD 599-KA04 509-BOD Bulletin 709 Motor Starter Coil 599-k04 PDF

    RK 891 031-aa

    Abstract: interposing relay RK 211 074 RK 211 064 RXMS1 ABB make RED 670 rk 223 069 ec RXME 1 abb rk 216 rk 211 072
    Text: Auxiliary, signalling and tripping relays RXMA1, RXMA 2, RXMM 1 RXMS 1, RXSF 1, RXME 1, RXME 18, RXMH 2 & RXMT 1 RXMM 1 SE 90 06 16 RXSF 1 (SE 82 02 62) (SE 82 02 62) (SE 94 07 44) (SE 94 07 41) Page 1 Issued July 2007 Revision: B Data subject to change without notice


    Original
    015-BEN 031-AA, 284-AAA 001-BEN 019-BEN 017-BEN 002-BEN 007-BEN 003-BEN RK 891 031-aa interposing relay RK 211 074 RK 211 064 RXMS1 ABB make RED 670 rk 223 069 ec RXME 1 abb rk 216 rk 211 072 PDF

    709 series K Allen-Bradley Starter

    Abstract: Allen-Bradley auxiliary contact 595-A Allen-Bradley starter 709 A2JD Allen-Bradley auxiliary contact 595-AB westinghouse contactor 195-FA11 interposing relay 196-fta smp1 OVERLOAD RELAY
    Text: Bulletin 509 NEMA Full Voltage Starters Bulletin 509 D Broad Range of NEMA Sizes 00–9 D Exceptional Electrical Life D UL Certified Type 2 Coordination D Dependable Coil Operation D Cost Saving Design D SMP–1 or SMP–3 Solid-State Overload Relays


    Original
    PDF

    abb contactor b9 30 10

    Abstract: EH550 T25DU B75 contactor ABB ABB EH550 contactors abb b12 contactor ABB EH300 Contactors B40 contactor ABB ABB EH550 ABB EH175 Contactors
    Text: Across the line starters Open & enclosed Description B9 – B75 • Maximum UL/CSA horsepower ratings • Compact space savings design • Standard auxiliary contact configurations: B9 - B25 1 N.O. or 1 N.C. B30 2 N.O. & 2 N.C. B40 - B75 1 N.O. & 1 N.C. • Additional auxiliary contact blocks are


    Original
    A95-A110; EH80-800 B9-75 abb contactor b9 30 10 EH550 T25DU B75 contactor ABB ABB EH550 contactors abb b12 contactor ABB EH300 Contactors B40 contactor ABB ABB EH550 ABB EH175 Contactors PDF

    POTENTIAL TRANSFORMER

    Abstract: interposing relay Pulse Transformer VAC interposing CT, technical AIPM interposing CT
    Text: SNAP-AIPM Modules Features Description The SNAP-AIPM analog input modules provide an efficient way to monitor AC voltage and current using a SNAP PAC rack-mounted controller or SNAP PAC brain. These modules can be used with both standard wired SNAP PAC brains and controllers and


    Original
    opto22 POTENTIAL TRANSFORMER interposing relay Pulse Transformer VAC interposing CT, technical AIPM interposing CT PDF

    Magnetic Field Sensor FLC 100

    Abstract: sensor FLC 100 PT100 thermistor motor protection
    Text: Gemstart 5 Volume 1 - Users Guide 276192-111 Rev. H Publication date: July 2014 Gemstart 5 Volume 1 – Users Guide Foreword This Technical Handbook provides the User with the information necessary to Install, Commission, Operate, Maintain and Test the equipment as applicable . It is essential that


    Original
    EN61000-4-11 ENV50204 Magnetic Field Sensor FLC 100 sensor FLC 100 PT100 thermistor motor protection PDF

    RET316

    Abstract: HESG448750M0002 500RIO11 CAP316 316BM61b 1MRB380084 K24E 1MRB520051-Uen 316DB63 ABB RET 316
    Text: Numerical transformer protection RET316*4 1MRK504007-Ben Page 1 Issued: February 2002 Changed since: December 1999 Data subject to change without notice Features • One three-phase differential function for two- or three-winding transformers • No interposing CTs


    Original
    RET316 1MRK504007-Ben 316/RET316 CAP316 XS92b RIO580 CH-5400 1MRB520051-Uen HESG448750M0002 500RIO11 316BM61b 1MRB380084 K24E 1MRB520051-Uen 316DB63 ABB RET 316 PDF

    interposing CT

    Abstract: transformer calculation ret 521 neutral earth BUSBAR calculation 48 VDC interposing relay three-winding transformer 015-UEN 608-CA mva transformer RXIDG DY11 vector group
    Text: 7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5 7 &  1MRK 504 018-BEN Page 1 Issued: March 2003 Revision: A Data subject to change without notice (SE960158 )HDWXUHV • Pre-configured transformer terminal for cost-effective engineering and commissioning • Easy to order


    Original
    018-BEN SE960158) 010-BEN 001-BEN 015-BEN SE-721 interposing CT transformer calculation ret 521 neutral earth BUSBAR calculation 48 VDC interposing relay three-winding transformer 015-UEN 608-CA mva transformer RXIDG DY11 vector group PDF

    three-winding power transformer

    Abstract: RTXP24 40 MVA transformer transformer calculation ret 521 Yy0 vector group 2.5 mva transformer calculation of transformer differential relay DY11 vector group interposing CT E-max MOTHERBOARD MANUAL
    Text: 7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5 7 &  1MRK 504 020-BEN Page 1 Issued: March 2003 Revision: A Data subject to change without notice (SE960158 )HDWXUHV • Pre-configured transformer terminal for cost-effective engineering and commissioning • Easy to order


    Original
    020-BEN SE960158) 010-BEN 001-BEN 015-BEN SE-721 three-winding power transformer RTXP24 40 MVA transformer transformer calculation ret 521 Yy0 vector group 2.5 mva transformer calculation of transformer differential relay DY11 vector group interposing CT E-max MOTHERBOARD MANUAL PDF

    c316fna3

    Abstract: contactor wiring diagram with timer
    Text: Accessories & Modification Codes 16-1 Accessories & Modification Codes April 2008 Contents 16 Description Page Accessories IT. NEMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Freedom NEMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


    Original
    PG03300001E c316fna3 contactor wiring diagram with timer PDF

    overcurrent relay inverse normal curves

    Abstract: neutral earth BUSBAR calculation transformer calculation ret 521 48 VDC interposing relay Yy0 vector group DY11 vector group BUS BAR emissivity electric field disturbance monitor mva transformer ANSI overcurrent relay inverse normal curves
    Text: 7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5 7 &  1MRK 504 040-BEN Page 1 Issued: March 2004 Revision: Data subject to change without notice (SE960158 )HDWXUHV • Pre-configured transformer terminal for cost-effective engineering and commissioning - Overexcitation restraint with 5th harmonic


    Original
    040-BEN SE960158) SE-721 overcurrent relay inverse normal curves neutral earth BUSBAR calculation transformer calculation ret 521 48 VDC interposing relay Yy0 vector group DY11 vector group BUS BAR emissivity electric field disturbance monitor mva transformer ANSI overcurrent relay inverse normal curves PDF

    three-winding power transformer

    Abstract: Yy0 vector group DY11 vector group RTXP24 transformer calculation ret 521 three-winding transformer per unit 500 MVA power transformers parameters automatic phase changer E-max MOTHERBOARD MANUAL 1MRK 000 508-BB
    Text: 7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5 7 &  1MRK 504 042-BEN Page 1 Issued: March 2004 Revision: Data subject to change without notice (SE960158 )HDWXUHV • Pre-configured transformer terminal for cost-effective engineering and commissioning • Easy to order


    Original
    042-BEN SE960158) SE-721 three-winding power transformer Yy0 vector group DY11 vector group RTXP24 transformer calculation ret 521 three-winding transformer per unit 500 MVA power transformers parameters automatic phase changer E-max MOTHERBOARD MANUAL 1MRK 000 508-BB PDF

    Untitled

    Abstract: No abstract text available
    Text: Specifying and Using Vacuum Circuit Breakers with PowerFlex 7000 Application Guidelines Important User Information Read this document and the documents listed in the Additional Resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to


    Original
    7000-AT003B-EN-P 7000-AT003A-EN-P PDF

    DY11 transformer

    Abstract: selective harmonic elimination circuits overcurrent relay inverse normal curves 48 VDC interposing relay transformer calculation ret 521 earth BUSBAR calculation automatic phase changer mva transformer tap transformer mva transformer calculation
    Text: 7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5 7 &  1MRK 504 041-BEN Page 1 Issued: March 2004 Revision: Data subject to change without notice (SE960158 )HDWXUHV • Pre-configured transformer terminal for cost-effective engineering and commissioning - Overexcitation restraint with 5th harmonic


    Original
    041-BEN SE960158) DY11 transformer selective harmonic elimination circuits overcurrent relay inverse normal curves 48 VDC interposing relay transformer calculation ret 521 earth BUSBAR calculation automatic phase changer mva transformer tap transformer mva transformer calculation PDF

    wye-delta controller with timer

    Abstract: Allen-Bradley contactor B110 OVERLOAD RELAY smp1 OVERLOAD RELAY 100-b110 interposing relay star delta wiring diagram motor start y smp1 400 vac 193-NX15 1203-SG2 schematic
    Text: PLEASE READ! This manual is intended to guide qualified personnel in the installation and operation of this product. Because of the variety of uses for this equipment and because of the differences between this solid-state equipment and electromechanical equipment, the user of and those responsible


    Original
    NX1311 wye-delta controller with timer Allen-Bradley contactor B110 OVERLOAD RELAY smp1 OVERLOAD RELAY 100-b110 interposing relay star delta wiring diagram motor start y smp1 400 vac 193-NX15 1203-SG2 schematic PDF

    realtime PID controller

    Abstract: interposing CT
    Text: Opto 22 Energy Monitoring Unit Features SNAP-IT-EMU1 Description The Opto 22 Energy Monitoring Unit OptoEMU1 is a complete package of Opto 22 hardware and software that lets you monitor energy usage for a 3-phase electrical device—such as an air conditioning and heating unit, compressor, or electric motor—so


    Original
    24-hour opto22 realtime PID controller interposing CT PDF

    Magnetic Sensor 81l

    Abstract: residual voltage overvoltage 59N broken conductor telemecanique timer catalogue ANSI 87T
    Text: Electrical network protection Sepam series 20, series 40, series 60, series 80 Digital protection relays Catalogue 2013 Sepam series 20 Sepam series 40 Sepam series 60 Sepam series 80 General Content Range description 1 Sepam series 20 and Sepam series 40


    Original
    SEPED303005EN Magnetic Sensor 81l residual voltage overvoltage 59N broken conductor telemecanique timer catalogue ANSI 87T PDF

    interposing CT

    Abstract: abb rxdsb 4 ABB SLCE 8 RXDSB 4 ASEA BROWN BOVERI interposing current transformers 1MDU04007-EN ABB SLCE 16 BROWN BOVERI relay CE RXDSB4 interposing relay
    Text: Type RADSB A8EA 8R O W N BOVEFtf Transformer differential protection 1MDB04007-EN Page 1 March 1992 Changed since August 1990 Data subject to change wihtout notice ABB N etw ork Control & Protection 840536 I (90142) Features Application •Complete phase and earth fault protection


    OCR Scan
    1MDB04007-EN 1MDU04007-EN AG03-5005E interposing CT abb rxdsb 4 ABB SLCE 8 RXDSB 4 ASEA BROWN BOVERI interposing current transformers ABB SLCE 16 BROWN BOVERI relay CE RXDSB4 interposing relay PDF

    BROWN BOVERI Relay manual

    Abstract: ABB NI 40 Relay manual tap control transformer RAYA ABB rxce 41 Relay manual 3 phase automatic phase changer RXCE 4 automatic phase changer file ABB NI 41 Relay settings RXTNB21 automatic 3 phase changer
    Text: Type RAYA Voltage regulating relay for tap changer control ASEA BROWN BGVEfii 1MDB04011-EN Page 1 March 1992 Changed since August 1990 Data subject to change without notice ABB Network Control & Protection a i 1 , 0 á lú i- . ¿i M Irtfl ÌO í O I¿ . a >


    OCR Scan
    1MDB04011â 162-DA 162-DAA 4U-36C RK821 021-AA 021-AB 021-AC 1MDB09004-EN BROWN BOVERI Relay manual ABB NI 40 Relay manual tap control transformer RAYA ABB rxce 41 Relay manual 3 phase automatic phase changer RXCE 4 automatic phase changer file ABB NI 41 Relay settings RXTNB21 automatic 3 phase changer PDF

    RADSS

    Abstract: calculation of transformer differential relay setting SUMMATION DIFFERENTIAL PROTECTION CALCULATION Asea low voltage protection relay SUMMATION current transformer
    Text: INFORMATION RFA, September 1981 Edition 1 From/Date Info-No. RF 637-333 E Reg. Page I Check zone for RADSS independent of switching in the current circuit The bus protection RADSS is normally equipped with an over­ current starting relay 5p. The starting relay S^ measures the


    OCR Scan
    0500-BC jJ55i 052-AA RADSS calculation of transformer differential relay setting SUMMATION DIFFERENTIAL PROTECTION CALCULATION Asea low voltage protection relay SUMMATION current transformer PDF

    Allen-Bradley starter 709

    Abstract: Allen-Bradley 709 starter Allen-Bradley bulletin 712 Bulletin 709 Motor Starter Coil Allen-Bradley 800T Allen-Bradley bulletin 509 starter Bulletin 509 contactor coils Allen-Bradley 709 Allen-Bradley reduced voltage starter Allen-Bradley contactor 100
    Text: APPLICATION NOTES flb BULLETIN 2100 CENTERLINE MOTOR CONTROL CENTERS CONTROL CIRCUIT TRANSFORMER SELECTION Purpose Introduction The purpose of th is technical paper is to provide guidelines for th e proper selection of A llen-Bradley control circuit transform ers used in conjunction w ith the A llen-Bradley


    OCR Scan
    PDF