Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    GUARDMASTER SI Search Results

    GUARDMASTER SI Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    XLP-3

    Abstract: 440C-ENET 440C-CR30-22BBB
    Text: User Manual — Original Language Guardmaster 440C-CR30 Configurable Safety Relay Catalog Number 440C-CR30-22BBB Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and


    Original
    PDF 440C-CR30 440C-CR30-22BBB RA-DU002, 440C-UM001D-EN-P 440C-UM001C-EN-P XLP-3 440C-ENET 440C-CR30-22BBB

    MSR126.1T

    Abstract: MSR126T MSR126 440RN23114 440R-N23117 440R-N23120 GuardMaster MSR126R MSR126R msr126.1r 440R-N23114
    Text: Safety Relays Monitoring Safety Relays Minotaur MSR126R/T Specifications Description The Allen-Bradley Guardmaster Minotaur MSR126R/T is a safety monitoring relay that provides the very basics for safety control systems in a 22.5mm package. The MSR126R/T is designed for connection to a single channel


    Original
    PDF MSR126R/T EN954-1, ISO13849-1, EN60204-1, IEC60947-4-1, IEC60947-5-1, AS4024 EN954-1 42/115/230V 50/60Hz MSR126.1T MSR126T MSR126 440RN23114 440R-N23117 440R-N23120 GuardMaster MSR126R MSR126R msr126.1r 440R-N23114

    IEC60068-2-29

    Abstract: MSR126.1T msr127 1606-XLP72E Allen-Bradley MSR127 440L-P4K1120YD 440R-P23071 MSR126T 440R-N23135 GuardMaster light curtains
    Text: Presence Sensing Safety Devices Safety Light Curtains GuardShield Type 4 Specifications Description The Allen-Bradley Guardmaster GuardShield safety light curtain is an economical, fully featured, Type 4 safety light curtain in a uniquely styled housing. GuardShield safety light curtains are general


    Original
    PDF 160mm. 1760mm 160mm 3-7m/14mm 3m-18m/30mm 98-59ft/1 14mm/30mm 55in/1 MSR127 MSR127 IEC60068-2-29 MSR126.1T 1606-XLP72E Allen-Bradley MSR127 440L-P4K1120YD 440R-P23071 MSR126T 440R-N23135 GuardMaster light curtains

    440EL13193

    Abstract: 440EL13137 440EL22BNST 440EL22BNSM GuardMaster lifeline 4 440EL13166 440EL13153 440EL13131 guardmaster 440 440EL22BNSL
    Text: Product Safety Group 1201 South Second Street Milwaukee, WI USA 53204 productsafety@ra.rockwell.com PRODUCT SAFETY ADVISORY Notice of Potential Unsafe Condition GuardMaster Lifeline 4 Cable Pull Switches Reference: 2010-05-001 Revision: A Date: May 2010 June 2010


    Original
    PDF

    Allen-Bradley en60204-1

    Abstract: allen bradley contactor B300 440R-D23021 MSR7R EN574 FUSE 451 440R D23021 440r-d23025 440R-D23022 IEC60947-5-1
    Text: Safety Relays Two Hand Relays Minotaur MSR7R & MSR7C Specifications Description The Allen-Bradley Guardmaster Minotaur MSR7R & MSR7C are logic units for monitoring and interfacing two hand control devices with a safety related circuit. The MSR7R is for use with mechanical


    Original
    PDF EN574, EN954-1, ISO13849-1, IEC/EN60204-1, IEC60947-5-1, AS4024 Allen-Bradley en60204-1 allen bradley contactor B300 440R-D23021 MSR7R EN574 FUSE 451 440R D23021 440r-d23025 440R-D23022 IEC60947-5-1

    GuardMaster ferrogard 21DC

    Abstract: BS3146 GuardMaster CONTROL UNIT EN 60204-1 Ferrogard 21DC GuardMaster gd2 ferrogard 2AC Guardmaster EN1088 Reed Magnete interrupteur commutateur GuardMaster
    Text: FERROGARD GD2 b Description The Ferrogard GD2 range of magnetically actuated, non-contact safety interlock switches are used to stop machine power when a guard is opened. When the stop signal is applied and the guard is opened, the action of the actuator being removed from the switch


    Original
    PDF 98/37/EC 73/23/EEC GuardMaster ferrogard 21DC BS3146 GuardMaster CONTROL UNIT EN 60204-1 Ferrogard 21DC GuardMaster gd2 ferrogard 2AC Guardmaster EN1088 Reed Magnete interrupteur commutateur GuardMaster

    guardmaster cu2

    Abstract: GuardMaster CONTROL UNIT EN 60204-1 GuardMaster gd2 GuardMaster 6 volt dc to 110v ac inverter circuit diagram GuardMaster CONTROL UNIT cu2 stop motion detection FUSE 500mA GuardMaster wn2 4hr diode led rouge 5mm GuardMaster CONTROL UNIT cu2 EN 60204
    Text: a CU3 Description The CU3 has been designed to detect motion of single phase or three phase motors, by measuring the back electro magnetic field (e.m.f) of the motor on two terminals of one stator winding. When the supply is turned down to zero or disconnected and the back e.m.f. is less than 0.5 volts AC (motor


    Original
    PDF 98/37/EC) 73/23/EEC guardmaster cu2 GuardMaster CONTROL UNIT EN 60204-1 GuardMaster gd2 GuardMaster 6 volt dc to 110v ac inverter circuit diagram GuardMaster CONTROL UNIT cu2 stop motion detection FUSE 500mA GuardMaster wn2 4hr diode led rouge 5mm GuardMaster CONTROL UNIT cu2 EN 60204

    guardmaster atlas 4

    Abstract: GuardMaster atlas 5 gd2 guardmaster atlas 3 safety switch guardmaster atlas safety switch cerberus cu2 ATLAS 5 gd2 guardmaster safety switch bouton poussoir ci guardmaster atlas 4 safety switch GuardMaster guardmaster cu2
    Text: ATLAS 5-GD2 a HEAVY DUTY SOLENOID LOCKING SAFETY SWITCH ÄUßERST ROBUSTE SICHERHEITSZUHALTUNG OPTIONAL / OPTION (b) Description. The Atlas 5 (with optional trapped key) is a positive mode, tongue operation, machine guard locking interlock switch. It locks the guard closed until the


    Original
    PDF

    MSR15D

    Abstract: bouton poussoir ci GuardMaster GuardMaster safety switch GuardMaster CONTROL UNIT EN 60204-1 EN1050 anzeige GuardMaster CONTROL UNIT tuv sp 1000VA
    Text: Beschreibung Der MINOTAUR MSR15D ist ein Sicherheitsbaustein, der die korrekte Funktion von Sicherheitsstromkreisen überwacht. Er ist mit unverzögerten und verzögerten Ausgängen versehen. Mit einer 2-kanaligen Eingangskonfiguration überwacht das Gerät


    Original
    PDF MSR15D D13/D14ortie bouton poussoir ci GuardMaster GuardMaster safety switch GuardMaster CONTROL UNIT EN 60204-1 EN1050 anzeige GuardMaster CONTROL UNIT tuv sp 1000VA

    GuardMaster ferrogard 21DC

    Abstract: Ferrogard 21DC FERROCODE EN60204 Ferrogard 21AC GuardMaster FRS 6 frs3 relay ferrogard Guardmaster EN1088 frs 21 dc guardmaster
    Text: a Description (a) Description SPECIALISTS IN MACHINERY SAFETY Ferrogard FRS 1, 2, 3, 4, 5, 6, 9, 10, 20DC, 21AC, 21DC, GS1 & GS2 MAGNETICALLY OPERATED SAFETY SWITCH MAGNET-SICHERHEITSSCHALTER INTERRUPTEUR DE SECURITE MAGNETIQUES SANS CONTACT See enclosed Declaration of Conformity for details.


    Original
    PDF

    minotaur MSR6R/T Universal Safety Relay

    Abstract: GuardMaster CONTROL UNIT EN 60204-1 GuardMaster GuardMaster CONTROL UNIT minotaur msr6r/t GuardMaster wn2 4hr MSR6R/T wn2 4HR GuardMaster safety switch logique
    Text: See enclosed Declaration of Conformity for details. Siehe Anlage: Konformitätserklärung. Voir la declaration de conformite ci-jointe pour details. MINOTAUR MSR6R/T Universal Monitoring Safety Relay For Interlock Switches And Emergency Stop Devices. Relais-Sicherheitsbaustein für Sicherheitsschalter und NOT-AUS-Befehlsgeräte.


    Original
    PDF S13-S14 S23-S24. minotaur MSR6R/T Universal Safety Relay GuardMaster CONTROL UNIT EN 60204-1 GuardMaster GuardMaster CONTROL UNIT minotaur msr6r/t GuardMaster wn2 4hr MSR6R/T wn2 4HR GuardMaster safety switch logique

    GuardMaster trojan 5

    Abstract: GuardMaster trojan 5 6 guardmaster 947-5-1 GuardMaster guardmaster IEC 947-5-1 GuardMaster wn2 4hr IEC 60947-5-1 ip 67 Guardmaster EN1088 guardmaster IEC 60947-5-1 trojan 5
    Text: See enclosed Declaration of Conformity for details. Siehe Anlage: Konformitätserklärung. Voir la declaration de conformite ci-jointe pour details. SPECIALISTS IN MACHINERY SAFETY UL C UL R 940060 R Listed UNIVERSAL TONGUE OPERATED SAFETY INTERLOCK SWITCH.


    Original
    PDF 175mm 75mm2. UL508 GuardMaster trojan 5 GuardMaster trojan 5 6 guardmaster 947-5-1 GuardMaster guardmaster IEC 947-5-1 GuardMaster wn2 4hr IEC 60947-5-1 ip 67 Guardmaster EN1088 guardmaster IEC 60947-5-1 trojan 5

    MSR12T

    Abstract: MSR12 GuardMaster CONTROL UNIT GuardMaster CONTROL UNIT EN 60204-1 GuardMaster 35MM EN292 EN954-1 GuardMaster wn2 4hr fusible Am
    Text: MSR12T MONITORING SAFETY RELAY ÜBERWACHUNGS-/SCHUTZRELAIS RELAIS DE SECURITE POUR CONTROLE b Description The unit will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs for more than 0.5 secs, the unit will lock out the outputs to the OFF state. Normal operation can only


    Original
    PDF MSR12T S13-S14 S23-S24. MSR12T 98/37/EC) 73/23/EEC 89/336/EEC MSR12 GuardMaster CONTROL UNIT GuardMaster CONTROL UNIT EN 60204-1 GuardMaster 35MM EN292 EN954-1 GuardMaster wn2 4hr fusible Am

    MSR11R

    Abstract: GuardMaster CONTROL UNIT EN 60204-1 minotaur alimentation pc GuardMaster CONTROL UNIT Deutsch Relay 4a GuardMaster safety switch MSR11 MSR12T EN6020
    Text: a MINOTAUR MSR11R (b) Description This unit will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs for more than 0.5 secs, the unit will lock out the outputs to the OFF state. Normal operation can only be resumed after both inputs are open and then closed synchronously


    Original
    PDF MSR11R MSR11R 98/37/EC) 73/23/EEC 89/336/EEC GuardMaster CONTROL UNIT EN 60204-1 minotaur alimentation pc GuardMaster CONTROL UNIT Deutsch Relay 4a GuardMaster safety switch MSR11 MSR12T EN6020

    GuardMaster trojan 5

    Abstract: GuardMaster trojan 5 EX GuardMaster trojan 5 6 guardmaster IEC 60947-5-1 GuardMaster Catalogue SAFETY SWITCH guardmaster trojan 5 AC15 trojan 5 bouton poussoir GuardMaster CONTROL UNIT EN 60204-1 GuardMaster wn2 4hr
    Text: TONGUE OPERATED GUARD INTERLOCK SWITCH - INC. STANDARD & EX VERSIONS TROJAN 5 a Description The Trojan 5 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open.


    Original
    PDF

    GuardMaster

    Abstract: MSR6R/T minotaur msr6r/t MSR7R 1000v contactor GuardMaster CONTROL UNIT wn2 4HR minotaur GuardMaster wn2 4hr circuit logique
    Text: a Beschreibung (a) Description The Minotaur MSR7R is a safety relay specifically designed for monitoring of two hand control switches. Using dual channel inputs, the unit checks the operation of two independent 1 N/O and 1 N/C actuators and then gives the approprite


    Original
    PDF 98/37/EC) 73/23/EEC 89/336/EEC GuardMaster MSR6R/T minotaur msr6r/t MSR7R 1000v contactor GuardMaster CONTROL UNIT wn2 4HR minotaur GuardMaster wn2 4hr circuit logique

    l455

    Abstract: minotaur msr8t GuardMaster wn2 4hr S14 contactor DC-13 wn2 4HR DIN VDE 0113 switch GuardMaster safety switch msr8t GuardMaster minotaur msr6r/t
    Text: See enclosed Declaration of Conformity for details. Siehe Anlage: Konformiätserklärung. Voir la declaration de conformite ä-jointe pour details MINOTAUR MSR8T SINGLE CHANNEL INPUT MONITORING SAFETY RELAY & EXTENSION UNIT. RELAIS-SICHERHEITSBAUSTEIN FÜR SICHERHEITSSCHALTER UND NOT-AUS-BEFEHLSGERÄTE 1-KANALIGER EINGANG UND ERWEITERUNGSEINHEIT.


    Original
    PDF 110VAC FROMS13 230VAC l455 minotaur msr8t GuardMaster wn2 4hr S14 contactor DC-13 wn2 4HR DIN VDE 0113 switch GuardMaster safety switch msr8t GuardMaster minotaur msr6r/t

    GuardMaster gd2

    Abstract: guardmaster IEC 60947-5-1 GuardMaster Catalogue SAFETY SWITCH GUARDMASTER CADET 3 gd2 guardmaster GuardMaster CONTROL UNIT EN 60204-1 GuardMaster CONTROL UNIT GuardMaster safety switch 9053B A600
    Text: a CADET 3 Description The Cadet 3 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open. (b) ? Installation Instructions


    Original
    PDF 98/37/EC) 73/23/EEC GuardMaster gd2 guardmaster IEC 60947-5-1 GuardMaster Catalogue SAFETY SWITCH GUARDMASTER CADET 3 gd2 guardmaster GuardMaster CONTROL UNIT EN 60204-1 GuardMaster CONTROL UNIT GuardMaster safety switch 9053B A600

    MSR9T

    Abstract: A600 GS-ET-15 IEC68 guardmaster IEC 60947-5-1 GuardMaster gd2 GuardMaster CONTROL UNIT EN 60204-1 minotaur MSR9T
    Text: ACCESSOIRES ZUBEHÖR e ACCESSORIES Security screwdriver Replacement Resistorx security key GD2 accessoy kit Replacement actuators are available by arrangement. Note: Access to spare actuators should be restricted to authorised personnel to prevent bypassing of the safety function


    Original
    PDF UL508 MSR9T A600 GS-ET-15 IEC68 guardmaster IEC 60947-5-1 GuardMaster gd2 GuardMaster CONTROL UNIT EN 60204-1 minotaur MSR9T

    PILZ pnoz

    Abstract: guardmaster atlas 3 safety switch Pilz safety relay Electronic security code lock system - Door Lock - Safe Lock circuit diagram guardmaster atlas 4 GuardMaster CENTURION circuit diagram of door interlock system guardmaster atlas safety switch 343-981 323-987
    Text: Issued November 1993 B16718 Machineguardinterlocking RS stock no. 325-703 323-993 351-241 351-257 323-971 323-987 325-141 325-157 325-129 325-135 324-772 333-574 759-213 343-981 350-074 319-663 319-269 319-275 319-281 Description Rotacam 2N/C contact block


    Original
    PDF B16718 PILZ pnoz guardmaster atlas 3 safety switch Pilz safety relay Electronic security code lock system - Door Lock - Safe Lock circuit diagram guardmaster atlas 4 GuardMaster CENTURION circuit diagram of door interlock system guardmaster atlas safety switch 343-981 323-987

    GuardMaster

    Abstract: C3003 GuardMaster safety switch GuardMaster wn2 4hr guardmaster IEC 60947-5-1 MT-GD2 wn2 4HR GuardMaster gd2 GuardMaster CONTROL UNIT EN 60204-1 minotaur
    Text: HEAVY DUTY, TONGUE OPERATED GUARD INTERLOCK SWITCH MT-GD2 a The MT-GD2 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open.


    Original
    PDF 98/37/EC) 73/23/EEC GuardMaster C3003 GuardMaster safety switch GuardMaster wn2 4hr guardmaster IEC 60947-5-1 MT-GD2 wn2 4HR GuardMaster gd2 GuardMaster CONTROL UNIT EN 60204-1 minotaur

    GuardMaster CONTROL UNIT EN 60204-1

    Abstract: minotaur MSR9T GuardMaster safety switch GuardMaster wn2 4hr MSR9T S2213 wn2 4HR en 60204-1 FUSE 500mA GuardMaster CONTROL UNIT
    Text: MINOTAUR MSR9T INSTALLATION INSTRUCTIONS / MONTAGEANLEITUNG / NOTICE D'INSTALLATION 120.0 To gain access to switches & fuse flip off lid with a small screwdriver. 45.5 73 Access to replaceable fuse Voltage 230V Switch 110V Isolate power before opening. Drawing No. 23633


    Original
    PDF 120mm, GuardMaster CONTROL UNIT EN 60204-1 minotaur MSR9T GuardMaster safety switch GuardMaster wn2 4hr MSR9T S2213 wn2 4HR en 60204-1 FUSE 500mA GuardMaster CONTROL UNIT

    Guardmaster EN1088

    Abstract: BS5304 EN1088 GS-ET-15 GuardMaster wn2 4hr GuardMaster safety switch GS-ET15 BS53 wn2 4HR JET 2A 250V
    Text: INSTALLATION INSTRUCTIONS MONTAGEANLEITUNG / NOTICE D'INSTALLATION 4 1mm min 2.5mm max 2 x M4 2 6 2 x M4 5 1 3 2.5mm y Entr End mm & nt Fro in. 150 m B1 B2 0mm . 20 mm n i try m 150 t En min. Fron Entry End 2 x M4 2 ELF 1 Conduit M16 PG9 entry Part 33001 33002


    Original
    PDF

    GuardMaster TLS2 gd2

    Abstract: GuardMaster gd2 TLS1 GD2 GuardMaster tls-1 TLS-1 GD2 27122 GuardMaster safety switch gd2 manual GuardMaster TLS3-GD2 gd2 guardmaster TLS-GD2 TLS1-GD2
    Text: Robust, A tongue operated interlocking with guard locking Guardmaster's newTLS-G D2 is a robust interlocking safety switch fo r Holds guard shut until machine is signalled safe guard locking. It is designed w ith a stainless steel actuator entry guide Holding force up to of 2000N


    OCR Scan
    PDF 2000N. 2000N GuardMaster TLS2 gd2 GuardMaster gd2 TLS1 GD2 GuardMaster tls-1 TLS-1 GD2 27122 GuardMaster safety switch gd2 manual GuardMaster TLS3-GD2 gd2 guardmaster TLS-GD2 TLS1-GD2