Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    GPON ONT SFP Search Results

    GPON ONT SFP Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    U77A21142D01 Amphenol Communications Solutions SFP CAGE Visit Amphenol Communications Solutions
    U77A21141001 Amphenol Communications Solutions SFP CAGE Visit Amphenol Communications Solutions
    U77A21142001 Amphenol Communications Solutions SFP CAGE Visit Amphenol Communications Solutions
    U77A41142001 Amphenol Communications Solutions SFP CAGE Visit Amphenol Communications Solutions
    U77E412M2081 Amphenol Communications Solutions SFP CAGE Visit Amphenol Communications Solutions

    GPON ONT SFP Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    1310nm TRANSMITTER CIRCUIT DIAGRAM for CATV

    Abstract: moca filter catv FTM-9823T-CGHIG moca filter CATV RF AGC Amplifier GPON ont SFP RX-28 3F80 CLASS G Triplexer
    Text: May 14, 2007 GPON ONT Triplexer FTM-9823T-CGH i (G) (ITU-T Rec.G.984.2) Members of FlexonTM Family Standard ‹ Compliant with ITU-T G.984.2, G.984.2 Amendment 1, G.983.3 Single Compliant with FCC 47 CFR Part 15, Class B ‹ Compliant with FDA 21 CFR 1040.10 and 1040.11,


    Original
    FTM-9823T-CGH 1244Mbit/s 2488Mbit/s 870MHz 1310nm 1244/2488M 1490nm 1310nm TRANSMITTER CIRCUIT DIAGRAM for CATV moca filter catv FTM-9823T-CGHIG moca filter CATV RF AGC Amplifier GPON ont SFP RX-28 3F80 CLASS G Triplexer PDF

    GPON ont SFP

    Abstract: FTM-9723S-SLGH FTM-9723S-SLGHIG GPON OLT GPON SFP GPON SFP class c rssi gpon GPON ONU SFP
    Text: Apr. 18, 2007 SC Receptacle SFP GPON OLT Transceiver FTM-9723S-SLGH i G (ITU-T Rec.G.984.2, G.984.2 Amendment 1) Member of FlexonTM Family Standard ‹ Compliant with SFF-8074i and SFF-8472 Rev 9.5 ‹ Compliant with ITU-T G.984.2, ITU-T G.984.2 Amendment 1


    Original
    FTM-9723S-SLGH SFF-8074i SFF-8472 32Mbps 16Mbps 1490nm 131implied GPON ont SFP FTM-9723S-SLGHIG GPON OLT GPON SFP GPON SFP class c rssi gpon GPON ONU SFP PDF

    GPON ont SFP

    Abstract: Rx_PWR GPON OLT rssi gpon gpon optical line termination FTM-9723P-KGH PDF PIN APD DIODE DESCRIPTION IEC-60825 72CID
    Text: Jun.7, 2006 2x10 SFF G-PON OLT Transceiver FTM-9723P-KGH G Members of FlexonTM Family Standard ‹ Compliant with ITU-T G.984.2 Amendment 1 ‹ Compliant with FCC 47 CFR Part 15, Class B ‹ Compliant with FDA 21 CFR 1040.10 and 1040.11, Class Description FTM-9723P-KGH(G) is Optical Line Terminal (OLT)


    Original
    FTM-9723P-KGH 32Mbps 32Mbps 16Mbps 1310nm DS3633001-1d GPON ont SFP Rx_PWR GPON OLT rssi gpon gpon optical line termination PDF PIN APD DIODE DESCRIPTION IEC-60825 72CID PDF

    circuit diagram wireless video transmitter and re

    Abstract: GPON ont SFP 1310nm TRANSMITTER CIRCUIT DIAGRAM for CATV MAX3816 AN3812 GPON schematics GPON ONT ONU GPON ont SFP RF simple home alarm circuit diagram ONT SFP
    Text: Fiber 9th Edition January 2009 Reduce risk and beat deadlines with proven reference designs ce Referen ve sa designs d time an money ASSEMBLED BOARDS EVALUATION SOFTWARE LAYOUT FILES BOARD LAYERS TEST RESULTS SCHEMATICS BILL OF MATERIALS Designs for every application


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: SPS-34-24T-HP-TDFO Features z Simplex SC Connector, Integrated Diplexer Transceiver z SFP MSA, digital diagnostics SFF-8472 Compliant z Compliant to FSAN G.984.2 Specifications z 1244 Mbps Tx, 2488 Mbps Rx Asymmetric Data Rate z Operating case temperature: -40~85°C


    Original
    SPS-34-24T-HP-TDFO SFF-8472 IEC-60825 SPS-34-24T-HP-TDFO DS-6831 DS-7417 PDF

    Untitled

    Abstract: No abstract text available
    Text: SPS-34-24T-HP-TDFM Features z Simplex SC Connector, Integrated Diplexer Transceiver z SFP MSA, digital diagnostics SFF-8472 Compliant z Compliant to FSAN G.984.2 Specifications z 1244 Mbps Tx, 2488 Mbps Rx Asymmetric Data Rate z Dying Gasp notification z Response the TX power shut-down command from OLT when


    Original
    SPS-34-24T-HP-TDFM SFF-8472 IEC-60825 SPS-34-24T-HP-TDFM DS-6831 PDF

    Untitled

    Abstract: No abstract text available
    Text: Finisar Preliminary Product Specification GPON OLT Class B+ Pigtailed RoHS Compliant Transceiver FTGL2025S1xUS • PRODUCT FEATURES • Bi-directional transceivers operating at 2.488 Gbit/s downstream, 1.244 Gbit/s upstream • Di-plexer operation at 1490 nm Tx,


    Original
    FTGL2025S1xUS GR326 SMF-28 PDF

    PTB3J85-5648N-SC

    Abstract: GPON ont SFP NeoPhotonics GPON GPON ONU
    Text: www.neophotonics.com VER B PTB3J85-5648N-SC/APC-KPD+ ITU-T G.984.5 compliant GPON ONU 1 1.1 Features Single Fiber GPON ONU Transceiver 1310nm burst-mode 1.244 Gb/s transmitters with DFB laser 1490nm continuous-mode 2.488Gb/s APD receiver 1.2 Compliant to ITU-T G.984.2 Class B+


    Original
    PTB3J85-5648N-SC/APC-KPD+ 1310nm 1490nm 488Gb/s 244Gb/s 244Gbps /1490nm 488Gbps, PTB3J85-5648N-SC GPON ont SFP NeoPhotonics GPON GPON ONU PDF

    rssi gpon

    Abstract: GPON ont SFP GPON SFP class c
    Text: SPW-xx-48H-CP-CDFA GPON CWDM OLT Features • Burst receive GPON Class C+ CWDM OLT transceiver with RSSI • Small Form Factor Pluggable, Dual LC Connector • “Fast Signal Detect” feature reduces ranging overhead • Simplified OLT “reset” timing


    Original
    SPW-xx-48H-CP-CDFA Tx/1244 DS-6067 rssi gpon GPON ont SFP GPON SFP class c PDF

    POWER SUPPLY BOARD 94V0

    Abstract: finisar gpon sfp GPON ont SFP POWER SUPPLY BOARD 20 94V0 finisar A0h GPON OLT POWER SUPPLY 94V0 GPON SFP class c APD 1550 nm SFP fiber optic pinout
    Text: Finisar Preliminary Product Specification GPON OLT Class B+ Pigtailed RoHS Compliant Transceiver FTGL2025S1TUx • PRODUCT FEATURES • Bi-directional transceivers operating at 2.488 Gbit/s downstream, 1.244 Gbit/s upstream • Di-plexer operation at 1490 nm Tx,


    Original
    FTGL2025S1TUx GR326 SMF-28 POWER SUPPLY BOARD 94V0 finisar gpon sfp GPON ont SFP POWER SUPPLY BOARD 20 94V0 finisar A0h GPON OLT POWER SUPPLY 94V0 GPON SFP class c APD 1550 nm SFP fiber optic pinout PDF

    Untitled

    Abstract: No abstract text available
    Text: SPS-34-24T-HP-CDFA Features z Simplex SC Connector, Integrated Diplexer Transceiver z SFP MSA, digital diagnostics SFF-8472 Compliant z Voice/Data FTTx ONT/ONU Applications z Compliant to FSAN G.984.5 Specifications z 1244 Mbps Tx, 2488 Mbps Rx Asymmetric Data Rate


    Original
    SPS-34-24T-HP-CDFA SFF-8472 IEC-60825 DS-6181 PDF

    Untitled

    Abstract: No abstract text available
    Text: OPGP-34-A4A3SK SFF 2x10 GPON Class A ONU Transceiver 2.488Gbps Downstream/1.244Gbps Upstream FEATURES  ITU-T G.984.2 compliant GPON ONU Class A  Support Digital Diagnostic Monitoring Interface  2x10 pin SFF package with pigtail fiber and SC/APC connector


    Original
    OPGP-34-A4A3SK 488Gbps 244Gbps 1310nm 1490nm 1550nm 1650nm GR-468 E239394 PDF

    OPGP-34-A4B3RD

    Abstract: GPON ont SFP MC100LVELT23 EN-60825-2 GPON EIA-JESD22-A114 GR-468 OPGP-34-A4B3R msa transceiver ont GPON SFP class c
    Text: OPGP-34-A4B3RD SFF 2x10 GPON Class B+ ONU Transceiver 2.488Gbps Downstream/1.244Gbps Upstream FEATURES z RoHS-6 compliant z ITU-T G.984.2 compliant GPON ONU Class B+ z Support Digital Diagnostic Monitoring Interface z 2x10 pin SFF package with 900mm pigtail fiber


    Original
    OPGP-34-A4B3RD 488Gbps 244Gbps 900mm 1310nm 1490nm 1550nm 1650nm GR-468 R50032471 OPGP-34-A4B3RD GPON ont SFP MC100LVELT23 EN-60825-2 GPON EIA-JESD22-A114 OPGP-34-A4B3R msa transceiver ont GPON SFP class c PDF

    OPGP-34-A4B3SET

    Abstract: ONT SFP GPON ont SFP a4b3 thomson laser bar
    Text: OPGP-34-A4B3SE T SFF 2x10 GPON Class B+ ONU Transceiver 2.488Gbps Downstream/1.244Gbps Upstream FEATURES  ITU-T G.984.2 compliant GPON ONU Class B+  Support Digital Diagnostic Monitoring Interface  2x10 pin SFF package with pigtail fiber and SC/APC connector


    Original
    OPGP-34-A4B3SE 488Gbps 244Gbps 1310nm 1490nm 1550nm 1650nm GR-468 488GbpsEC/EN EIA-JESD22-A114 OPGP-34-A4B3SET ONT SFP GPON ont SFP a4b3 thomson laser bar PDF

    OPGP-34-A4B3SD

    Abstract: OPGP-34-A4B3SdT eeprom 1011
    Text: OPGP-34-A4B3SD T SFF 2x10 GPON Class B+ ONU Transceiver 2.488Gbps Downstream/1.244Gbps Upstream FEATURES  ITU-T G.984.2 compliant GPON ONU Class B+  Support Digital Diagnostic Monitoring Interface  2x10 pin SFF package with 900mm pigtail fiber and SC/APC connector


    Original
    OPGP-34-A4B3SD 488Gbps 244Gbps 900mm 1310nm 1490nm 1550nm 1650nm GR-468 MIL-STD-883E OPGP-34-A4B3SdT eeprom 1011 PDF

    GPON ONT block diagram

    Abstract: SPS-34-24T-HP-CDFA 6e522
    Text: SPS-34-24T-HP-CDFA 1310/1490 Integrated Diplexer Transceiver Features • Simplex SC Connector, Integrated Diplexer Transceiver • SFP MSA, digital diagnostics SFF-8472 Compliant • Voice/Data FTTx ONT/ONU Applications • Compliant to FSAN G.984.5 Specifications


    Original
    SPS-34-24T-HP-CDFA SFF-8472 IEC-60825 OC-24 1244Mbps) DS-6181 GPON ONT block diagram SPS-34-24T-HP-CDFA 6e522 PDF

    ONT SFP

    Abstract: GPON ONT block diagram 6c s 38 SPS-34-24T-HP-TDFA 1490n BLOCK diagram of light sensitive alarm DS-6284
    Text: SPS-34-24T-HP-TDFA 1310/1490 Integrated Diplexer Transceiver Features • Simplex SC Connector, Integrated Diplexer Transceiver • SFP MSA, digital diagnostics SFF-8472 Compliant • Voice/Data FTTx ONT/ONU Applications • Compliant to FSAN G.984.5 Specifications


    Original
    SPS-34-24T-HP-TDFA SFF-8472 IEC-60825 OC-24 1244Mbps) DS-6284 ONT SFP GPON ONT block diagram 6c s 38 SPS-34-24T-HP-TDFA 1490n BLOCK diagram of light sensitive alarm PDF

    optical module tx 1490nm

    Abstract: No abstract text available
    Text: OPGP-34-A4B3SL SFF 2x10 GPON Class B+ ONU Transceiver 2.488Gbps Downstream/1.244Gbps Upstream FEATURES  ITU-T G.984.2 compliant GPON ONU Class B+  Support Digital Diagnostic Monitoring Interface  2x10 pin SFF package with pigtail fiber and SC/APC connector


    Original
    OPGP-34-A4B3SL 488Gbps 244Gbps 1310nm 1490nm 1550nm 1650nm GR-468 Pin20 optical module tx 1490nm PDF

    OPGP-34-A4B3SL

    Abstract: No abstract text available
    Text: OPGP-34-A4B3SL SFF 2x10 GPON Class B+ ONU Transceiver 2.488Gbps Downstream/1.244Gbps Upstream FEATURES  ITU-T G.984.2 compliant GPON ONU Class B+  Support Digital Diagnostic Monitoring Interface  2x10 pin SFF package with pigtail fiber and SC/APC connector


    Original
    OPGP-34-A4B3SL 488Gbps 244Gbps 1310nm 1490nm 1550nm 1650nm GR-468 Pin20 OPGP-34-A4B3SL PDF

    OPGP-34-A4B3SL-B

    Abstract: EIA-JESD22-A114 GR-468 GPON ont SFP
    Text: OPGP-34-A4B3SL-B SFF 2x10 GPON Class B+ ONU Transceiver 2.488Gbps Downstream/1.244Gbps Upstream FEATURES  ITU-T G.984.2 compliant GPON ONU Class B+  Support Digital Diagnostic Monitoring Interface  2x10 pin SFF package with pigtail fiber and SC/APC connector


    Original
    OPGP-34-A4B3SL-B 488Gbps 244Gbps 1310nm 1490nm 1550nm 1650nm GR-468 21CFR OPGP-34-A4B3SL-B EIA-JESD22-A114 GPON ont SFP PDF

    Untitled

    Abstract: No abstract text available
    Text: OPGP-34-A4B3SL-B SFF 2x10 GPON Class B+ ONU Transceiver 2.488Gbps Downstream/1.244Gbps Upstream FEATURES  ITU-T G.984.2 compliant GPON ONU Class B+  Support Digital Diagnostic Monitoring Interface  2x10 pin SFF package with pigtail fiber and SC/APC connector


    Original
    OPGP-34-A4B3SL-B 488Gbps 244Gbps 1310nm 1490nm 1550nm 1650nm GR-468 21CFR PDF

    OPGP-34-A4B3SV

    Abstract: GPON SFP GPON ont SFP LVPECL 3,3V MC100LVELT23 GR-468 MC100LVELT23 sfp 1310nm OPGP-34-A4B3SVT thomson laser bar
    Text: OPGP-34-A4B3SV T SFF 2x10 GPON Class B+ ONU Transceiver 2.488Gbps Downstream/1.244Gbps Upstream FEATURES z ITU-T G.984.2 compliant GPON ONU Class B+ z Support Digital Diagnostic Monitoring Interface z 2x10 pin SFF package with 900mm pigtail fiber and SC/APC connector


    Original
    OPGP-34-A4B3SV 488Gbps 244Gbps 900mm 1310nm 1490nm 1550nm 1650nm GR-468 R50032471 GPON SFP GPON ont SFP LVPECL 3,3V MC100LVELT23 MC100LVELT23 sfp 1310nm OPGP-34-A4B3SVT thomson laser bar PDF

    GPON APD 1490nm

    Abstract: No abstract text available
    Text: OPGP-34-A4B3SD T SFF 2x10 GPON Class B+ ONU Transceiver 2.488Gbps Downstream/1.244Gbps Upstream FEATURES z ITU-T G.984.2 compliant GPON ONU Class B+ z Support Digital Diagnostic Monitoring Interface z 2x10 pin SFF package with 900mm pigtail fiber and SC/APC connector


    Original
    OPGP-34-A4B3SD 488Gbps 244Gbps 900mm 1310nm 1490nm 1550nm 1650nm GR-468 E239394 GPON APD 1490nm PDF

    OPGP-34-A4B3R

    Abstract: EN-60825-2 GPON GR-468 MC100LVELT23 OPGP-34-A4B3RM GPON ONT ONU
    Text: OPGP-34-A4B3R T E 2.488Gbps Downstream/1.244Gbps Upstream GPON ONU Transceiver FEATURES z RoHS-6 compliant z Support Digital Diagnostic Monitoring Interface and industrial operating case temperature from -40ºC to +85ºC z 2x10 pin SFF package with SC/APC pigtail


    Original
    OPGP-34-A4B3R 488Gbps 244Gbps 1310nm 1490nm 1550nm 1650nm GR-468 OPGP-34-A4B3RTE OPGP-34-A4B3RE EN-60825-2 GPON MC100LVELT23 OPGP-34-A4B3RM GPON ONT ONU PDF