Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    GLASS THERMOMETERS Search Results

    GLASS THERMOMETERS Result Highlights (3)

    Part ECAD Model Manufacturer Description Download Buy
    MD82510/B Rochester Electronics LLC Serial I/O Controller, 1 Channel(s), CMOS, CDIP28, GLASS SEALED, DIP-28 Visit Rochester Electronics LLC Buy
    5043/BEA Rochester Electronics LLC SPDT, 2 Func, 1 Channel, CMOS, CDIP16, GLASS, DIP-16 Visit Rochester Electronics LLC Buy
    10144569-002LF Amphenol Communications Solutions Hermetic Connector Series, 6Pin, Glass Sealed. Visit Amphenol Communications Solutions

    GLASS THERMOMETERS Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    Untitled

    Abstract: No abstract text available
    Text: MADE IN Series 445S USA Standard Threaded Well for Industrial Glass Thermometers * Application: Fits liquid-in-glass thermometers made to S.A.M.A. standards. Tapered bore is made .008 in. oversize to eliminate possibility of thermometer bulb expanding into


    Original
    C-1018) -445L OT-201 PDF

    Untitled

    Abstract: No abstract text available
    Text: White Back, Mercury-Filled Laboratory Thermometers CERTIFICATE OF CONFORMANCE TEFLON OPTION See Introduction Page to add these options. 14 $ Basic Unit ߜ Economical, General Purpose, Mercury-Filled Glass ߜ °F and °C Versions ߜ Ideal Where Glass Thermometers Are Frequently


    Original
    GT-1301W GT-1303W GT-6451W GT-1302W GT-6452W GT-66452W GT-1317W GT-1316W GT-1304W GT-6453W PDF

    NMP-K-M

    Abstract: Duct g23 thermistor water flow doppler pitot sensor ultrasonic flow meter Ultrasonic velocity 1-888-TC-OMEGA
    Text: Miniature Connectors Type NMP Glass-Filled Nylon 220°C 425°F Service Temperature ANSI color code shown To order IEC color code see pg. A-9 Glass-Filled Nylon $ 75 ߜ ߜ ߜ ߜ Glass-Filled Nylon Heavy Duty Construction Color-Coded Accepts Stranded or Solid Wire


    Original
    50-99eless EPG05 NMP-K-M Duct g23 thermistor water flow doppler pitot sensor ultrasonic flow meter Ultrasonic velocity 1-888-TC-OMEGA PDF

    Untitled

    Abstract: No abstract text available
    Text: Series 445L MADE IN USA Standard Threaded Well for Industrial Glass Thermometers Application: Fits liquid-in-glass thermometers made to S.A.M.A. standards. Tapered bore is made .008 in. oversize to eliminate possibility of thermometer bulb expanding into the well, thus preventing removal.


    Original
    C-1018) PDF

    Untitled

    Abstract: No abstract text available
    Text: Accessories for Glass Thermometers Open Face Armor Case OMEGA glass thermometers can be armored for added protection. The open face case is 25⁄64" diameter and made of attractive, durable plated brass. The lower end is perforated to permit free heat passage. The face is open so the protected


    Original
    GTA-6106BR GTA-6109BR GTA-6110BR GTA-6112BR GTA-6112SS GTA-6114BR GTA-6115BR GTA-6116BR GTA-6116SS GTA-6118BR PDF

    Untitled

    Abstract: No abstract text available
    Text: Series 260L Standard Threaded Well for 1⁄4" Diameter Elements Application: Standard Length, 1⁄4" stem, bimetal thermometers; #20 gage thermocouple elements; unarmored liquid-in-glass test thermometers. Other temperature-sensing elements having .252 in. maximum diameter.


    Original
    C-1018) PDF

    Untitled

    Abstract: No abstract text available
    Text: MADE IN Series 385S USA Standard Threaded Well for ⁄8" Diameter Elements 3 • Available in PFA Teflon , Epoxy and other materials. Application: Standard length, 3⁄8" stem, bimetal thermometers. #14 gage thermocouple elements. Armored liquid-in-glass


    Original
    C-1018) OT-201 PDF

    Untitled

    Abstract: No abstract text available
    Text: Series 385HL MADE IN USA Heavy Duty Well for ⁄8" Diameter Elements Application: Standard length, 3⁄8" stem, bimetal thermometers. #14 gage thermocouple elements. Armored liquid-in-glass test thermometers. Other temperature-sensing elements having .377 in. maximum diameter.


    Original
    385HL C-1018) 304SS 304SS) PDF

    Untitled

    Abstract: No abstract text available
    Text: ASTM Certified Glass Thermometers ߜ Meets Strict Guidelines of the ASTM ߜ Provides Highly Accurate and Reproducible Measurements ߜ Variety of ASTM Applications ߜ Yellow Back with Permanent Markings for High Visibility ߜ Variety of Immersion Lengths and Styles


    Original
    GTM-7421 ASTM-3970C ASTM-39600C ASTM-3964F ASTM-1-16 PDF

    Untitled

    Abstract: No abstract text available
    Text: MADE IN Series 260S USA Standard Threaded Well for ⁄4" Diameter Elements 1 Application: Standard length, 1⁄4" stem, bimetal thermometers; #20 gage thermocouple elements; unarmored liquid-in-glass test thermometers. Other temperature-sensing elements having .252 in. maximum diameter.


    Original
    C-1018) OT-201 PDF

    Untitled

    Abstract: No abstract text available
    Text: Series 260H MADE IN USA Heavy Duty Threaded Well for 1⁄4" Diameter Elements Application: Standard length, 1⁄4" bimetal thermometers. #20 gage thermocouple elements. Unarmored liquid-in-glass test thermometers. Other temperature-sensing elements having .252 in. maximum diameter.


    Original
    C-1018) Mone050 260HL OT-201 PDF

    Untitled

    Abstract: No abstract text available
    Text: Solar-Powered Thermometers for Bi-Metal and Glass Thermometer Stem Applicators - SPT10 Series ߜ Self-Powered with Ten Lux Rating ߜ Capable of Handling Humidity up to 95% RH Non-Condensing ߜ Display Can Pivot and Swivel ߜ 0.375" 9.5 mm LCD Display ߜ ˚C/˚F Switchable


    Original
    SPT10 10-second SPT11-2 SPT11-4 GG-T-321D. SPT11-6 SPT12-3 SPT12-6 SPT11-6, PDF

    Untitled

    Abstract: No abstract text available
    Text: Calibration Technology Starts Here High Precision Digital Thermometer The BetaProbe TI A single BetaProbe TI high precision digital thermometer can replace many liquid-in-glass l-i-g thermometers. It can also serve as a reference standard for other types of digital or analog temperature


    Original
    RS-232 ITS10ATEX27114X ITS10 0049X 1012R2CD-TI PDF

    soil "electrical conductivity"

    Abstract: DTC-K-M ultrasonic temperature transducers pitot sensor ultrasonic flow meter Ultrasonic FLOW Transducer R type thermocouple doppler probe
    Text: 4-Prong Dual Circuit Standard Connectors Type DTC, Glass-Filled Nylon Rated from -29 to 220oC -20 to 425oF The OMEGA DTC is one connector which performs the function of two. The DTC connects two pairs of thermocouple wires or one dual thermocouple and two extension


    Original
    220oC 425oF) EPG05 soil "electrical conductivity" DTC-K-M ultrasonic temperature transducers pitot sensor ultrasonic flow meter Ultrasonic FLOW Transducer R type thermocouple doppler probe PDF

    SMPW-K-M

    Abstract: Omega Engineering SR-SMP-100 CW-SMP-100 dissolved pitot sensor copper brass washers SR-SMP-10 CW-SMP-20 1888T
    Text: Most Popular Miniature Connectors ANSI color code shown To order IEC color code see pg. A-9 Type SMPW Glass Filled Nylon -29 to 220°C -20 to 425°F Service Temperature ED L Type HMPW Liquid Crystal Polymer L I SS-FON! A L 260°C/500°F Service Temperature


    Original
    C/500 EPG05 SMPW-K-M Omega Engineering SR-SMP-100 CW-SMP-100 dissolved pitot sensor copper brass washers SR-SMP-10 CW-SMP-20 1888T PDF

    Untitled

    Abstract: No abstract text available
    Text: Principles of Infrared Thermometry W. R. Barron, Williamson Corporation Temperature measurement can be divided into two categories: contact and noncontact. Contact thermocouples, RTDs, and thermometers are the most prevalent in temperature measurement applications. They must contact the


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Bi-Metal Thermometers Rugged and Reliable The all metal construction, except for the optically clear crystal of DiaITemp thermometers and their heliarc welded fabrication make them virtually unbreakable. The type 304 Stainless Steel stems offer exceptional protection against


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Vapor and Gas Actuated Thermometers $ 52 MADE IN USA Basic Unit ߜ Accuracy ±1 Scale Division or 1% Scale for Gas ߜ Brass Movement with Precision Gearing ߜ White Dial with Black Graduations ߜ Phosphor Bronze Bourdon Tube OMEGA remote Vapor and Gas Actuated Thermometers are


    Original
    25FRGlass 1/2-445S-U1 15/16-316SS-SB PDF

    Untitled

    Abstract: No abstract text available
    Text: LOW COST ELECTRONIC THERMOMETERS SPECIFICATIONS ߜ Rugged Stainless Steel Probe ߜ Choice of °C or °F Readout The PHTC1 and PHTF1 digital thermometers conveniently combine a probe and digital meter into one easy-to-use unit. The probe is a thermistor, housed in a stainless


    Original
    battery/700 PDF

    Untitled

    Abstract: No abstract text available
    Text: General-Purpose, Low-Cost Thermometers Economical, Ideal for School and Laboratory Applications! Unbelievably Low Cost! Purchase in Quantity, for Even Better Prices. See Discount Schedule Below Discount Schedule for Low-Cost Thermometers 11-24 Units …………………………10%


    Original
    GT-736280 GT-736540 GT-736550 GT-736560 GT-737680 PDF

    Untitled

    Abstract: No abstract text available
    Text: INFRARED DETECTOR PbS photoconductive detector P394 series, P2532-01, P2682-01 Infrared detectors utilizing photoconductive effects Features Applications l Room temperature operation Makes PbS cells useful in a wide range of applications including radiation thermometers and flame monitors


    Original
    P2532-01, P2682-01 SE-171 KIRD1019E02 PDF

    pr 8501 b

    Abstract: P394A P3226-02 P3226 PBS P394 series
    Text: PbS Photoconductive Detectors Easy-to-use photoconductive detec­ tors with high responsivity over 3 jim • Operates at room temperature Since PbS cells operate stably at room temperature, they are used in a wide range of applications such as radiation thermometers and flame


    OCR Scan
    KI80A0055EA 0G0470 P394A, P3226-02 P791-11 P3207-04 P4115 K1713-01, K3413-01, P3981-01, pr 8501 b P394A P3226-02 P3226 PBS P394 series PDF

    P3226

    Abstract: P5168 P3226-02 G5832-05 P2682-01 P394 series Photodiode 2PIN TYPES G3476-01 G5832-02 P3258-02
    Text: PbS Photoconductive Detectors Easy-to-use photoconductive detec­ tors with high responsivity over 3 jim • Operates at room temperature Since PbS cells operate stably at room temperature, they are used in a wide range of applications such as radiation thermometers and flame


    OCR Scan
    KIRDA0044EB 000M7D3 P2750, C4159, C4159-02 K1RDA004SEB C5185, C3757-02 D004704 P3226 P5168 P3226-02 G5832-05 P2682-01 P394 series Photodiode 2PIN TYPES G3476-01 G5832-02 P3258-02 PDF

    Untitled

    Abstract: No abstract text available
    Text: PbS Photoconductive Detectors Spectral Response Range: 1.0 to 3.6 n_m Easy-to-use photoconductive detectors with high responsivity over 3 jim •Room temperature operation Since PbS cells operate stably at room temperature, they are used in a wide range of applications such as radiation thermometers and flame


    OCR Scan
    KIRDB0050EA PDF