Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    FUSES FOR CAPACITORS Search Results

    FUSES FOR CAPACITORS Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DE6B3KJ151KA4BE01J Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    DE6B3KJ471KB4BE01J Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    DE6E3KJ152MN4A Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    DE6B3KJ101KA4BE01J Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    DE6B3KJ331KB4BE01J Murata Manufacturing Co Ltd Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd

    FUSES FOR CAPACITORS Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    bussmann semiconductor fuse catalogue

    Abstract: bs1362 BUSSMANN SFT Series HKP-HH fuses T2A 250V C520 A/D 1.5A, 125V, 32mm glass fuse IEC-127-4 HTC220M FUSE 3A 125V SMT
    Text: Bussmann Table of Contents Fuse Holder Selection Chart 2 Surface Mount Fuses 3 Axial and Radial Leaded Fuses 8 5 x 15mm Fuses 12 5 x 20mm Fuses 18 6.3 x 32mm Fuses 36 Automotive Fuses 46 Miscellaneous Fuses 47 Fuse Clips for 5mm dia. Fuses 51 Fuse Clips for 6.3mm dia. Fuses


    Original
    PDF S504-V S505-V TDC10 TDC11 TDC17 TDC180 bussmann semiconductor fuse catalogue bs1362 BUSSMANN SFT Series HKP-HH fuses T2A 250V C520 A/D 1.5A, 125V, 32mm glass fuse IEC-127-4 HTC220M FUSE 3A 125V SMT

    UL198L

    Abstract: G212917 E214962 K218325 V200877 Z201640 K219360 A222571 M212922 A4J175
    Text: General Purpose US US Fuses General Purpose Fuses American Power Fuses AMP-TRAP A4J Class J FA FOR EXCELLENT CURRENT LIMITING PROTECTION A4J Class J fuses deliver excellent current-limiting protection to a wide variety of applications. Their unique dimensions prevent the substitution of


    Original
    PDF rep-400 GPUS34 GPUS35 UL198L G212917 E214962 K218325 V200877 Z201640 K219360 A222571 M212922 A4J175

    400 amp hrc fuse

    Abstract: i2t motor protection thermal fuse 117 BUSSMANN EDISON APPLICATION OF hrc fuse thermal fuse 3.5 amps edison curve 7 MPR-20 100cj
    Text: EDISON TYPE CJ FAST ACTING FUSES 600V a.c. or less, 250V d.c. 200,000A I.R. to CSA C22-2 No. 106 M92 Industrial Duty Fuses with Ceramic Bodies HRCI-J fuses are usually specified to protect low voltage distribution systems within building and light industrial installations, up to and including 600 Amp ratings. For compatible performance above 600 Amps use Edison LCU fast-acting HRC-L fuses.


    Original
    PDF C22-2 400 amp hrc fuse i2t motor protection thermal fuse 117 BUSSMANN EDISON APPLICATION OF hrc fuse thermal fuse 3.5 amps edison curve 7 MPR-20 100cj

    Untitled

    Abstract: No abstract text available
    Text: AMP-TRAP A4J FAST ACTING/Class J For excellent CURRENT LIMITING PROTECTION A4J Class J fuses deliver excellent current-limiting protection to a wide variety of applications. Their unique dimensions prevent the substitution of other fuses with lower voltage ratings, interrupting ratings,


    Original
    PDF A4J30

    IEC 269-2-1

    Abstract: 61038J A4J100 A4J200 A4J60 A4J300 64033J 6631J A4J125 A4J45
    Text: AMP-TRAP A4J FAST ACTING / CLASS J FOR EXCELLENT CURRENT LIMITING PROTECTION A4J Class J fuses deliver excellent current-limiting protection to a wide variety of applications. Their unique dimensions prevent the substitution of other fuses with lower voltage ratings, interrupting


    Original
    PDF Rati203 A4J30 IEC 269-2-1 61038J A4J100 A4J200 A4J60 A4J300 64033J 6631J A4J125 A4J45

    US3J3I

    Abstract: 62003J 61038J 64031J IEC 269-2-1 6633J A4J100 A4J90 A4J400 61036J
    Text: AMP-TRAP A4J FAST ACTING/Class J For excellent CURRENT LIMITING PROTECTION A4J Class J fuses deliver excellent current-limiting protection to a wide variety of applications. Their unique dimensions prevent the substitution of other fuses with lower voltage ratings, interrupting ratings,


    Original
    PDF A4J30 US3J3I 62003J 61038J 64031J IEC 269-2-1 6633J A4J100 A4J90 A4J400 61036J

    Untitled

    Abstract: No abstract text available
    Text: A4J Fast Acting/Class J For excellent current-limiting protection A4J Class J fuses deliver excellent current-limiting protection to a wide variety of applications. Their unique dimensions prevent the substitution of other fuses with lower voltage ratings, interrupting ratings, or current-limiting capability.


    Original
    PDF 1-600A

    Linear Troubleshooting Guide

    Abstract: condor HDD15-5-A
    Text: Condor Application Note 5/00 LINEAR TROUBLESHOOTING GUIDE AN-109 WARNING! RISK OF FIRE & SAFETY! Repair must be performed by a Condor authorized personnel No Output: • Visually inspect the supply for open fuses, burnt or discolored parts vented capacitors


    Original
    PDF AN-109 Linear Troubleshooting Guide condor HDD15-5-A

    6F22 9V BATTERY

    Abstract: No abstract text available
    Text: www.Amprobe.com AM-500 DIY-PRO Digital Multimeter AM-500 Digital Multimeter Series Easy to use digital multimeter designed for the homeowner or office space maintenance person to check for voltage in receptacles, extension cords, light fixtures, batteries and other electrical circuits. Check fuses, light bulbs and


    Original
    PDF AM-500 AM-500 Accu6F22) AM-520 AM-530 AM-540 AM-550 877-AMPROBE 6F22 9V BATTERY

    Untitled

    Abstract: No abstract text available
    Text: LM8502 www.ti.com SNVS592D – OCTOBER 2009 – REVISED FEBRUARY 2013 LM8502 Intelligent Lighting Management Unit That Fuses a 1.2A Dual High-Side Flash LED Driver with a 10-Output Low-Side LED Driver Check for Samples: LM8502 FEATURES DESCRIPTION • The LM8502 is a versatile LED driver suitable for


    Original
    PDF LM8502 SNVS592D LM8502 10-Output

    Untitled

    Abstract: No abstract text available
    Text: LM8502 www.ti.com SNVS592D – OCTOBER 2009 – REVISED FEBRUARY 2013 LM8502 Intelligent Lighting Management Unit That Fuses a 1.2A Dual High-Side Flash LED Driver with a 10-Output Low-Side LED Driver Check for Samples: LM8502 FEATURES DESCRIPTION • The LM8502 is a versatile LED driver suitable for


    Original
    PDF LM8502 SNVS592D LM8502 10-Output

    DSD30

    Abstract: BS1361
    Text: Issued November 1983 B5112 Pullcap fuses Stocknumbers 413-787 to 413-850 The pullcap range of fuselinks is ASTA CERTIFIED to BS88 Part 1 1975 for a breaking capacity or rupturing capacity of 80kA at 415Vac and 40kA at 250Vdc. This means that it is ideal for applications where high


    Original
    PDF B5112 DSD30 415Vac 250Vdc. BS1361

    LWQ38

    Abstract: LM85 haptic sensor circuit THERMISTOR TDK 150M
    Text: LM8502 Intelligent Lighting Management Unit That Fuses a 1.2A Dual High-Side Flash LED Driver with a 10-Output Low-Side LED Driver General Description Features The LM8502 is a versatile LED driver suitable for multiple applications. It includes a 2MHz, fixed-frequency synchronous


    Original
    PDF LM8502 10-Output LM8502 LWQ38 LM85 haptic sensor circuit THERMISTOR TDK 150M

    139X

    Abstract: FN 1393
    Text: Versatile power entry module FN 390 • • • • up to 10A current ratings IEC 950-compliant twin fuse configurations only general-purpose or high-performance filtering for one or two fuses (Ø5 x 20 or Ø6.3 x 32mm) • • • • Nennstrom bis 10A


    Original
    PDF 950-compliant 139X FN 1393

    139X

    Abstract: FN 1393
    Text: Versatile power entry module FN 390 • • • • up to 10A current ratings IEC 950-compliant twin fuse configurations only general-purpose or high-performance filtering for one or two fuses (Ø5 x 20 or Ø6.3 x 32mm) • • • • Nennstrom bis 10A


    Original
    PDF 950-compliant 9222S/FN 9223S/FN 9224S/FN 9260S 92xxS-? 139X FN 1393

    Untitled

    Abstract: No abstract text available
    Text: Versatile power entry module FN 390 • • • • up to 10A current ratings IEC 950-compliant twin fuse configurations only general-purpose or high-performance filtering for one or two fuses (Ø5 x 20 or Ø6.3 x 32mm) • • • • Nennstrom bis 10A


    Original
    PDF 950-compliant

    Untitled

    Abstract: No abstract text available
    Text: Versatile power entry module FN 390 • • • • up to 10A current ratings IEC 950-compliant twin fuse configurations only general-purpose or high-performance filtering for one or two fuses (Ø5 x 20 or Ø6.3 x 32mm) • • • • Nennstrom bis 10A


    Original
    PDF 950-compliant

    Schaffner 1393

    Abstract: f 9222 l Schaffner catalog 139X EN 133200 iec 60939 SCHAFFNER FN fusibles
    Text: Versatile power entry module FN 390 • • • • up to 10A current ratings IEC 950-compliant twin fuse configurations only general-purpose or high-performance filtering for one or two fuses (Ø5 x 20 or Ø6.3 x 32mm) • • • • Nennstrom bis 10A


    Original
    PDF 950-compliant 110/230V 250VAC 389B-6/21 394E-2 Schaffner 1393 f 9222 l Schaffner catalog 139X EN 133200 iec 60939 SCHAFFNER FN fusibles

    BS1361

    Abstract: BS88 fuselink D3030 F192 FUSELINK TO BS88 PART 1
    Text: Issued November 1983 005-112 Data Pack B Pullcap fuses Data Sheet RS stock numbers 413-787 to 413-850 The pullcap range of fuselinks is ASTA CERTIFIED to BS88 Part 1 1975 for a breaking capacity or rupturing capacity of 80kA at 415Vac and 40kA at 250Vdc. This


    Original
    PDF 415Vac 250Vdc. BS1361 BS88 fuselink D3030 F192 FUSELINK TO BS88 PART 1

    BS1361

    Abstract: BS88 FUSELINK TO BS88 PART 1 D3030 F192 f192 transformer 415Vac
    Text: Issued March 1997 232-2649 Data Pack B Pullcap fuses Data Sheet RS stock numbers 413-787 to 413-850 The pullcap range of fuselinks is ASTA CERTIFIED to BS88 Part 1 1975 for a breaking capacity or rupturing capacity of 80kA at 415Vac and 40kA at 250Vdc. This


    Original
    PDF 415Vac 250Vdc. BS1361 BS88 FUSELINK TO BS88 PART 1 D3030 F192 f192 transformer

    top 261

    Abstract: No abstract text available
    Text: General-purpose power entry module FN 9260 • • • • Up to 10A current ratings IEC 950-compliant For one or two fuses Ø5 x 20mm Optional medical version (B type) • • • • Nennstrom bis 10A IEC 950 konform Für eine oder zwei Sicherungen (Ø5 x 20mm)


    Original
    PDF 950-compliant 261/FN 9260S 261S/FN top 261

    TNR391K010B

    Abstract: 6P45 TNR221K ring core permalloy bh curve mp3300 20dl2cz*a 50kV thyristor 100v dc to 220 ac with inverter transformer recti SRX333 AC reactor choke
    Text: 3 . CAUTIONS FOR USE 2 Protection devices. There are two major groups o f protection. 1. elements which break current 2. elements which suppress overcurrent. (a) Current break type element. 1) Current limiting fuse. Fuses for overcurrent break purpose are called current limiting fuses (or quick


    OCR Scan
    PDF TSE-387. TNR391K010B 6P45 TNR221K ring core permalloy bh curve mp3300 20dl2cz*a 50kV thyristor 100v dc to 220 ac with inverter transformer recti SRX333 AC reactor choke

    Untitled

    Abstract: No abstract text available
    Text: SCHAFFNER FN 370 Power entry module filter with IEC plug Voltage selector for series and parallel circuits 1 or 2 fuses Screw or snap-in mounting B-version: for medical equipment Applications: EDP peripherals, instruments, laboratory apparatus, copiers Type


    OCR Scan
    PDF 20V/50Hz

    Untitled

    Abstract: No abstract text available
    Text: General-purpose power entry module FN 9260 • up to 6A current ratings • IEC 950-compliant • for one or two fuses 05 x 20mm • optional medical version (B type) • Nennstrom bis 6A • IEC 950 konform • Fur eine Oder zwei Sicherungen (05 x 20mm)


    OCR Scan
    PDF 950-compliant 9260S 261S/FN