Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    FM25025 Search Results

    FM25025 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    50 watt amplifier circuit diagram

    Abstract: No abstract text available
    Text: TELEVISION TRANSMISSION BAND CIRCULATOR GENERAL INFORMATION • External Load Available This range of circulators is designed for amplifier protection in solid state television transmitters. Their purpose is to protect amplifiers whose outputs are to be combined to


    Original
    PDF FM25025 50 watt amplifier circuit diagram

    DML Microwave

    Abstract: No abstract text available
    Text: ISOHYBRID GENERAL INFORMATION To meet the demand for more compact and lower cost base stations SPECIFICATIONS Frequency Range 925 - 960, 1805 -1880, or 1930 - 1990 MHz Insertion Loss 3.4 dB max. by reducing the insertion loss and ensuring optimum matching


    Original
    PDF FM25025 DML Microwave

    microwave isolator

    Abstract: high power isolator Isolator what is the isolator DML Microwave
    Text: INTEGRATED ISOLATOR PACKAGE LOW COST - HIGH PERFORMANCE GENERAL INFORMATION The DML Microwave EGSM integrated isolator package can incorporate a number of components. This results in significant cost reductions, when compared to individual component prices.


    Original
    PDF FM25025 microwave isolator high power isolator Isolator what is the isolator DML Microwave

    circulator MHz

    Abstract: No abstract text available
    Text: EGSM CIRCULATOR WITH TAB CONNECTORS GENERAL INFORMATION • Single or Double Circulator This device is supplied for use in base station amplifiers, supplied with Tab connectors they can be directly soldered to the pcb. The advantage of the Tab connector is a better


    Original
    PDF FM25025 circulator MHz

    DML Microwave

    Abstract: circulator MHz
    Text: GSM CIRCULATOR GENERAL INFORMATION DML Microwave’s GSM Circulators have been developed specifically to meet the technical requirements of GSM Base Stations. The designs are based on techniques well proven in high volume Cellular radio applications. The device featured is a single junction circulator with low


    Original
    PDF FM25025 DML Microwave circulator MHz

    4636

    Abstract: No abstract text available
    Text: ETAC's & EGSM ISOLATORS & CIRCULATORS GENERAL INFORMATION This device from DML Microwave is the basis for most of its production of 900 MHz double junction isolators, offering as standard N type connectors and covering the full Frequency of 860 - 960 MHz, the unit offers high isolation and low


    Original
    PDF FM25025 4636

    CI701

    Abstract: CI802 CI801 CI601 CI600N CI602 CI603 CI604 CI605 CI606
    Text: SOLID STATE NOISE SOURCES GENERAL INFORMATION DML Microwave began manufacturing Noise Sources in 1972. Our current range includes narrow band and broadband devices in both Coaxial and Waveguide configurations. The Coaxial Noise Sources detailed here are highly versatile. Their miniature size, fast switching


    Original
    PDF FM25025 CI701 CI802 CI801 CI601 CI600N CI602 CI603 CI604 CI605 CI606

    NMT450

    Abstract: monitor cable diagram DML Microwave
    Text: 460 MHz ISOLATOR WITH DUAL POWER MONITORING GENERAL INFORMATION DML Microwave has been producing devices for the 380 - 500 MHz range since 1982, when we produced our initial design for the NMT450 systems. Since that time we have produced many different variants to meet specific customer requirements


    Original
    PDF NMT450 10MHz. FM25025 monitor cable diagram DML Microwave

    DML Microwave fic

    Abstract: DML Microwave circulator MHz Circulator
    Text: STANDARD CELLULAR ISOLATORS AND CIRCULATORS GENERAL INFORMATION DML Microwave is offering this following range of standard devices to meet the most common requirements within the cellular industry. Based on designs that have been production proven for a number of


    Original
    PDF FM25025 DML Microwave fic DML Microwave circulator MHz Circulator

    NMT450

    Abstract: DML Microwave
    Text: 460 MHz ISOLATOR GENERAL INFORMATION • Integral Loads DML Microwave has been producing devices for the 380 - 500 MHz range since 1982, when we produced our initial design for the NMT450 systems. Since that time we have produced many different variants to meet


    Original
    PDF NMT450 10MHz FM25025 DML Microwave

    QQ-A-250

    Abstract: 6061-T651 DUAL JUNCTION CIRCULATOR MIL-C-26074, Class 1, Grade B FEC-GSM-100 FEI Microwave MIL-C-26074 FEC-AMPS-100 869-894 circulator FEI-AMPS-75
    Text: DROP IN CIRCULATORS AND ISOLATORS GENERAL INFORMATION The “FEC”and “FEI”series offer drop-in or surface mount isolators and circulators that will accommodate most cellular and PCS applications. Our low profile, side magnet design offers a compact package with excellent isolation versus insertion loss characteristics.


    Original
    PDF de626-1 FE-A06 FM25025 QQ-A-250 6061-T651 DUAL JUNCTION CIRCULATOR MIL-C-26074, Class 1, Grade B FEC-GSM-100 FEI Microwave MIL-C-26074 FEC-AMPS-100 869-894 circulator FEI-AMPS-75

    CI701

    Abstract: CI801 CI600N CI601 CI602 CI603 CI604 CI605 CI606 CI607
    Text: SOLID STATE NOISE SOURCES SPECIFICATIONS GENERAL INFORMATION Micronetics, Inc. aquired this product line from DML Microwave in 2003. Our current range includes narrow band and broadband devices in both Coaxial and Waveguide configurations. The Coaxial Noise Sources


    Original
    PDF FM25025 CI701 CI801 CI600N CI601 CI602 CI603 CI604 CI605 CI606 CI607

    DML Microwave

    Abstract: 1702
    Text: IFF/SSR CIRCULATOR GENERAL INFORMATION SPECIFICATIONS This circulator is the result of DML Microwave policy of close customer co-operation. The unusual design features required to withstand the stress of high peak power operation were developed by working with the customer


    Original
    PDF FM25025 DML Microwave 1702

    Untitled

    Abstract: No abstract text available
    Text: PCN/PCS LOW NOISE AMPLIFIER GENERAL INFORMATION Specifically designed for PCN/PCS Base Station or Masthead Repeater applications. Integration of different amplification stages selected from our extensive library enables customised Amplifiers to be produced both quickly and cost effectively.


    Original
    PDF FM25025

    circulator MHz

    Abstract: essex microwave circulators DML Microwave
    Text: PCN CIRCULATOR WITH TAB CONNECTORS GENERAL INFORMATION • Integral Load available This device is supplied for use in PCN base station amplifiers, supplied with Tab connectors they can be directly soldered to the pcb.The advantage of the Tab connector is a better


    Original
    PDF FM25025 circulator MHz essex microwave circulators DML Microwave