50 watt amplifier circuit diagram
Abstract: No abstract text available
Text: TELEVISION TRANSMISSION BAND CIRCULATOR GENERAL INFORMATION • External Load Available This range of circulators is designed for amplifier protection in solid state television transmitters. Their purpose is to protect amplifiers whose outputs are to be combined to
|
Original
|
PDF
|
FM25025
50 watt amplifier circuit diagram
|
DML Microwave
Abstract: No abstract text available
Text: ISOHYBRID GENERAL INFORMATION To meet the demand for more compact and lower cost base stations SPECIFICATIONS Frequency Range 925 - 960, 1805 -1880, or 1930 - 1990 MHz Insertion Loss 3.4 dB max. by reducing the insertion loss and ensuring optimum matching
|
Original
|
PDF
|
FM25025
DML Microwave
|
microwave isolator
Abstract: high power isolator Isolator what is the isolator DML Microwave
Text: INTEGRATED ISOLATOR PACKAGE LOW COST - HIGH PERFORMANCE GENERAL INFORMATION The DML Microwave EGSM integrated isolator package can incorporate a number of components. This results in significant cost reductions, when compared to individual component prices.
|
Original
|
PDF
|
FM25025
microwave isolator
high power isolator
Isolator
what is the isolator
DML Microwave
|
circulator MHz
Abstract: No abstract text available
Text: EGSM CIRCULATOR WITH TAB CONNECTORS GENERAL INFORMATION • Single or Double Circulator This device is supplied for use in base station amplifiers, supplied with Tab connectors they can be directly soldered to the pcb. The advantage of the Tab connector is a better
|
Original
|
PDF
|
FM25025
circulator MHz
|
DML Microwave
Abstract: circulator MHz
Text: GSM CIRCULATOR GENERAL INFORMATION DML Microwave’s GSM Circulators have been developed specifically to meet the technical requirements of GSM Base Stations. The designs are based on techniques well proven in high volume Cellular radio applications. The device featured is a single junction circulator with low
|
Original
|
PDF
|
FM25025
DML Microwave
circulator MHz
|
4636
Abstract: No abstract text available
Text: ETAC's & EGSM ISOLATORS & CIRCULATORS GENERAL INFORMATION This device from DML Microwave is the basis for most of its production of 900 MHz double junction isolators, offering as standard N type connectors and covering the full Frequency of 860 - 960 MHz, the unit offers high isolation and low
|
Original
|
PDF
|
FM25025
4636
|
CI701
Abstract: CI802 CI801 CI601 CI600N CI602 CI603 CI604 CI605 CI606
Text: SOLID STATE NOISE SOURCES GENERAL INFORMATION DML Microwave began manufacturing Noise Sources in 1972. Our current range includes narrow band and broadband devices in both Coaxial and Waveguide configurations. The Coaxial Noise Sources detailed here are highly versatile. Their miniature size, fast switching
|
Original
|
PDF
|
FM25025
CI701
CI802
CI801
CI601
CI600N
CI602
CI603
CI604
CI605
CI606
|
NMT450
Abstract: monitor cable diagram DML Microwave
Text: 460 MHz ISOLATOR WITH DUAL POWER MONITORING GENERAL INFORMATION DML Microwave has been producing devices for the 380 - 500 MHz range since 1982, when we produced our initial design for the NMT450 systems. Since that time we have produced many different variants to meet specific customer requirements
|
Original
|
PDF
|
NMT450
10MHz.
FM25025
monitor cable diagram
DML Microwave
|
DML Microwave fic
Abstract: DML Microwave circulator MHz Circulator
Text: STANDARD CELLULAR ISOLATORS AND CIRCULATORS GENERAL INFORMATION DML Microwave is offering this following range of standard devices to meet the most common requirements within the cellular industry. Based on designs that have been production proven for a number of
|
Original
|
PDF
|
FM25025
DML Microwave fic
DML Microwave
circulator MHz
Circulator
|
NMT450
Abstract: DML Microwave
Text: 460 MHz ISOLATOR GENERAL INFORMATION • Integral Loads DML Microwave has been producing devices for the 380 - 500 MHz range since 1982, when we produced our initial design for the NMT450 systems. Since that time we have produced many different variants to meet
|
Original
|
PDF
|
NMT450
10MHz
FM25025
DML Microwave
|
QQ-A-250
Abstract: 6061-T651 DUAL JUNCTION CIRCULATOR MIL-C-26074, Class 1, Grade B FEC-GSM-100 FEI Microwave MIL-C-26074 FEC-AMPS-100 869-894 circulator FEI-AMPS-75
Text: DROP IN CIRCULATORS AND ISOLATORS GENERAL INFORMATION The “FEC”and “FEI”series offer drop-in or surface mount isolators and circulators that will accommodate most cellular and PCS applications. Our low profile, side magnet design offers a compact package with excellent isolation versus insertion loss characteristics.
|
Original
|
PDF
|
de626-1
FE-A06
FM25025
QQ-A-250
6061-T651
DUAL JUNCTION CIRCULATOR
MIL-C-26074, Class 1, Grade B
FEC-GSM-100
FEI Microwave
MIL-C-26074
FEC-AMPS-100
869-894 circulator
FEI-AMPS-75
|
CI701
Abstract: CI801 CI600N CI601 CI602 CI603 CI604 CI605 CI606 CI607
Text: SOLID STATE NOISE SOURCES SPECIFICATIONS GENERAL INFORMATION Micronetics, Inc. aquired this product line from DML Microwave in 2003. Our current range includes narrow band and broadband devices in both Coaxial and Waveguide configurations. The Coaxial Noise Sources
|
Original
|
PDF
|
FM25025
CI701
CI801
CI600N
CI601
CI602
CI603
CI604
CI605
CI606
CI607
|
DML Microwave
Abstract: 1702
Text: IFF/SSR CIRCULATOR GENERAL INFORMATION SPECIFICATIONS This circulator is the result of DML Microwave policy of close customer co-operation. The unusual design features required to withstand the stress of high peak power operation were developed by working with the customer
|
Original
|
PDF
|
FM25025
DML Microwave
1702
|
Untitled
Abstract: No abstract text available
Text: PCN/PCS LOW NOISE AMPLIFIER GENERAL INFORMATION Specifically designed for PCN/PCS Base Station or Masthead Repeater applications. Integration of different amplification stages selected from our extensive library enables customised Amplifiers to be produced both quickly and cost effectively.
|
Original
|
PDF
|
FM25025
|
|
circulator MHz
Abstract: essex microwave circulators DML Microwave
Text: PCN CIRCULATOR WITH TAB CONNECTORS GENERAL INFORMATION • Integral Load available This device is supplied for use in PCN base station amplifiers, supplied with Tab connectors they can be directly soldered to the pcb.The advantage of the Tab connector is a better
|
Original
|
PDF
|
FM25025
circulator MHz
essex
microwave circulators
DML Microwave
|